• No results found

Endovascular Aortic Repair

Volume of mural thrombus plays a role in the elevation of inflammatory markers after endovascular aortic repair

Volume of mural thrombus plays a role in the elevation of inflammatory markers after endovascular aortic repair

... It is relatively common for a systemic inflammatory response to occur after endovascular aortic repair (EVAR). This phenomenon, known as post-implantation syndrome (PIS), was first described in 1999 ...

7

Salmonella aortitis treated with endovascular aortic repair: a case report

Salmonella aortitis treated with endovascular aortic repair: a case report

... before endovascular aortic repair (EVAR) and regular follow-up computed tomography (CT) scans one week after EVAR and after three, six, 12 and 15 ...

5

Successful thoracic endovascular aortic repair for post-coarctoplasty aneurysm

Successful thoracic endovascular aortic repair for post-coarctoplasty aneurysm

... coarctation repair site and revealed formation of a large aneurysm in distal part of the aortic arch and proximal part of descending thor- acic aorta measuring an anteroposterior diameter of 50 mm that also ...

5

Neurological complications after thoracic endovascular aortic repair. Does the left subclavian artery coverage without revascularization increase the risk of neurological complications in patients after thoracic endovascular aortic repair?

Neurological complications after thoracic endovascular aortic repair. Does the left subclavian artery coverage without revascularization increase the risk of neurological complications in patients after thoracic endovascular aortic repair?

... thoracic aortic conditions has been completely revolutionized by intro- ducing thoracic endovascular aortic repair ...(TEVAR). Endovascular treatment is associated with reduced mor- ...

6

Open Repair Versus Thoracic Endovascular Aortic Repair in Multiple-Injured Patients: Observations From a Level-1 Trauma Center

Open Repair Versus Thoracic Endovascular Aortic Repair in Multiple-Injured Patients: Observations From a Level-1 Trauma Center

... The most important finding of our study was a decrease of in-hospital mortality following the introduction of endovascular aortic repair. From 1977 to 2005, the treat- ment algorithm consisted of OR ...

5

Thoracic endovascular aortic repair for complicated chronic type B aortic dissection in a patient on hemodialysis with recurrent ischemic colitis

Thoracic endovascular aortic repair for complicated chronic type B aortic dissection in a patient on hemodialysis with recurrent ischemic colitis

... thoracic endovascular aortic repair (TEVAR) for chronic Stanford type B aortic dissection (B-AD) with recurrent ischemic ...Dissection Endovascular System, and its procedure was ...

5

Thoracic Endovascular Aortic Repair (TEVAR) in traumatic high velocity blunt injury to thoracic aorta

Thoracic Endovascular Aortic Repair (TEVAR) in traumatic high velocity blunt injury to thoracic aorta

... All patients underwent a Thoracic Endovascular Aortic Repair (TEVAR) using a Medtronic Valiant delivery device and thoracic stent graft. This is performed via an arterial cutdown, commonly femoral, ...

6

Alternative management of the left subclavian artery in thoracic endovascular aortic repair for aortic dissection: a single-center experience

Alternative management of the left subclavian artery in thoracic endovascular aortic repair for aortic dissection: a single-center experience

... Thoracic Aortic Disease: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of ...

7

A novel anatomic severity grading score for acute Type B aortic dissections and correlation to aortic reinterventions after thoracic endovascular aortic repair

A novel anatomic severity grading score for acute Type B aortic dissections and correlation to aortic reinterventions after thoracic endovascular aortic repair

... of aortic growth in uncomplicated type B aortic dissections (TBAD), aor- tic diameter ≥ 40 mm, proximal descending thoracic aorta false lumen diameter ≥ 22 mm, degree of fusiform dilation of the proximal ...

13

Successful treatment of hemoptysis caused by a type 2 endoleak after thoracic endovascular aortic repair

Successful treatment of hemoptysis caused by a type 2 endoleak after thoracic endovascular aortic repair

... the aortic pseudoaneur- ysms from the supreme intercostal artery via the bron- chial artery ...the aortic sac via the bronchial ...the aortic sac and pseudoaneurysms via the inflowing ...

5

Application of rapid artificial cardiac pacing in thoracic endovascular aortic repair in aged patients

Application of rapid artificial cardiac pacing in thoracic endovascular aortic repair in aged patients

... The Seldinger approach of puncture into the femoral artery was made from the ideal side of the dissection relative to the real lumen, at 1–2 cm above the bifurcation point between the deep and superficial femoral artery ...

6

Correlations of perioperative coagulopathy, fluid infusion and blood transfusions with survival prognosis in endovascular aortic repair for ruptured abdominal aortic aneurysm

Correlations of perioperative coagulopathy, fluid infusion and blood transfusions with survival prognosis in endovascular aortic repair for ruptured abdominal aortic aneurysm

... 20. Wang H, Robinson RD, Phillips JL, Kirk AJ, Duane TM, Umejiego J, et al. Benefits of Initial Limited Crystalloid Resuscitation in Severely Injured Trauma Patients at Emergency Department. J Clin Med Res. 2015;7:947 – ...

6

Kidney autotransplantation for the treatment of renal artery occlusion after endovascular aortic repair: a case report

Kidney autotransplantation for the treatment of renal artery occlusion after endovascular aortic repair: a case report

... Reports on the occurrence of RAO after EVAR have been increasing as EVAR has become widely used for treating infrarenal aortic aneurysms [7]. Given that RAO after EVAR can lead to postoperative dialysis-dependent ...

7

Thoracic Aorta Aneurysm-Endovascular Aortic Repair

Thoracic Aorta Aneurysm-Endovascular Aortic Repair

... Both techniques provide detailed anatomic information pertaining to planning EVAR or open surgical repair. Aneurysms of the descending thoracic aorta more than 50 mm have a risk of rupture of approximately 1% per ...

5

Aortic remodeling in Type B aortic dissection after thoracic endovascular aortic repair with an aortic extender cuff implantation

Aortic remodeling in Type B aortic dissection after thoracic endovascular aortic repair with an aortic extender cuff implantation

... an aortic extender cuff ...an aortic extender cuff implantation improves remodeling of the dissected thoracic aorta, thus reducing the potential of ...

8

Endovascular Repair versus Open Repair for Isolated Descending Thoracic Aortic Aneurysm

Endovascular Repair versus Open Repair for Isolated Descending Thoracic Aortic Aneurysm

... thoracic endovascular aortic repair (TEVAR) with those of open repair for descending thoracic aortic aneurysms ...open repair groups were ...open repair group ...open ...

9

Anesthetic considerations for endovascular repair of ruptured abdominal aortic aneurysms

Anesthetic considerations for endovascular repair of ruptured abdominal aortic aneurysms

... abdominal aortic aneurysm (rAAA) carries high morbidity and ...in endovascular techniques in the last two decades allow for minimally invasive approach for repair of these ...life-saving. ...

6

A graft inversion technique for retrograde type A aortic dissection after thoracic endovascular repair for type B aortic dissection

A graft inversion technique for retrograde type A aortic dissection after thoracic endovascular repair for type B aortic dissection

... of aortic dissection should be 15–20% to provide sufficient radial force to reduce the incidence of postoperative complications such as aneurysm neck dilata- tion, type I endoleak, and device migration ...rates. ...

8

Transradial approach for the endovascular treatment of type I endoleak after aortic aneurysm repair: a case report

Transradial approach for the endovascular treatment of type I endoleak after aortic aneurysm repair: a case report

... Physical examination evidenced a tender and pulsatile abdominal mass, accompanied by the auscultatory find- ing of a systolic murmur in the paraumbilical region. During the hospitalization, aortic ecotomography ...

5

Predictors of adverse events after endovascular abdominal aortic aneurysm repair: A meta analysis of case reports

Predictors of adverse events after endovascular abdominal aortic aneurysm repair: A meta analysis of case reports

... Although a meta-analysis of case reports has some clear methodological drawbacks, it offers unique opportuni- ties. The risk factors for complications after endovascular AAA repair that are presented in ...

7

Show all 4988 documents...