• No results found

guide wire

Technical feasibility and performance studies of a Doppler guide wire for potential neuroendovascular applications

Technical feasibility and performance studies of a Doppler guide wire for potential neuroendovascular applications

... Benchtop testing showed the 0.014-inch Doppler guide wire to have comparable distal tip flexibility and stiffness to the commonly used micro-guide wire.. CONCLUSION: The comparable subje[r] ...

5

A custom made guide wire positioning device for Hip Surface Replacement Arthroplasty: description and first results

A custom made guide wire positioning device for Hip Surface Replacement Arthroplasty: description and first results

... Literature review shows that correct patient selection and implant positioning of both femoral and acetabular com- ponents are crucial in optimizing SRA outcome. Young and active males will benefit most from SRA [2,15]. ...

7

Influence of guide wire removal on tip location in peripherally inserted central catheters (PICCs): a retrospective cross-sectional study

Influence of guide wire removal on tip location in peripherally inserted central catheters (PICCs): a retrospective cross-sectional study

... of guide wire removal on tip location may also influence the ECG technology in a manner similar to that observed in patients in whom the tail end of the catheter was not adjusted in our ...of guide ...

5

Comparison of two percutaneous tracheostomy techniques, guide wire dilating forceps and Ciaglia Blue Rhino: a sequential cohort study

Comparison of two percutaneous tracheostomy techniques, guide wire dilating forceps and Ciaglia Blue Rhino: a sequential cohort study

... techniques: guide wire dilating forceps (GWDF) tra- cheostomy, Ciaglia Blue Rhino (CBR) tracheostomy, and sequential dilation tracheostomy (classic Ciaglia) ...

7

Percutaneous and surgical tracheostomy in critically ill adult patients: a meta analysis

Percutaneous and surgical tracheostomy in critically ill adult patients: a meta analysis

... Results: Fourteen RCTs tested PT techniques versus ST in 973 patients. PT techniques were performed faster (MD, − 13.06 minutes (95% CI, − 19.37 to − 6.76 (P <0.0001)); I 2 = 97% (P <0.00001)) and reduced odds for ...

21

Jugular Venous Catheterization: A Case of Knotting

Jugular Venous Catheterization: A Case of Knotting

... the guide wire was thought to be hooked and it caused the catheter to make a ...a guide wire through the catheter ...a guide wire ...

5

Innovative Design of Intervention Module for Vessel Intervention Surgery Robot Based on TRIZ Theory

Innovative Design of Intervention Module for Vessel Intervention Surgery Robot Based on TRIZ Theory

... a guide wire into specific lesions location in the blood vessel, to examine the vascular embolism and to expand balloon and ...the guide wire to a specific ...the guide wire at ...

6

Transfemoral Cervicocephalic Angiography in Children

Transfemoral Cervicocephalic Angiography in Children

... tip is in the ascending aorta about 5 cm distal to the aortic valve. Holding the wire steady, the catheter is advanced over the wire until the tips coincide. The guide wire is removed, a[r] ...

6

Alternative crossing technique for iliaco-femoro-popliteal CTOs with a catheter only

Alternative crossing technique for iliaco-femoro-popliteal CTOs with a catheter only

... With the additional help of the guide wire (mostly soft end, less often stiffer back end), the success rate is in- creased by 36.9%, adding up to a success rate of 84.7%. These results are consistent with ...

6

Triple Arthrodesis with Internal and External Fixation: Technique Paper

Triple Arthrodesis with Internal and External Fixation: Technique Paper

... screw guide wire is placed from the cuboid into the ...the guide wire and the measure is then utilized to obtain the correct ...the guide wire and inserted across the fusion ...

10

An endovascular retrieving device for use in small vessels

An endovascular retrieving device for use in small vessels

... Advancement of the snare catheter in a vessel is achieved by opening and closing its loop, much in the same manner as a standard guide wire is used in a push-pull fashion to ad-... ENDOV[r] ...

5

Percutaneous transhepatic hemodialysis catheters in chronic hemodialysis patients: technique, functional outcome, and complications from a large population study

Percutaneous transhepatic hemodialysis catheters in chronic hemodialysis patients: technique, functional outcome, and complications from a large population study

... Then under fluoroscopic guidance (TOSHIBA, Infx-8000v), a hydrophilic guide wire (0.035 in.) was introduced through the angiocath in hepatic vein, and secured up- wards in superior vena [r] ...

7

Minimally invasive surgical treatment on delayed uretero-vaginal fistula

Minimally invasive surgical treatment on delayed uretero-vaginal fistula

... Under continuous epidural or general anesthesia, all 46 pa- tients were placed in the flank-reclining, split-leg position for simultaneous antegrade and retrograde ureteroscopy. We inserted an F16 ureteroscope in the ...

6

Clinical value of DPOC for detecting and removing residual common bile duct stones (video)

Clinical value of DPOC for detecting and removing residual common bile duct stones (video)

... the cases of ampulla were in or next to the diverticulum, there was space for a small incision (Fig. 1). Therefore, the small incision and balloon expansion technique (at least 10 mm) far exceeds the outer diameter of ...

7

Percutaneous Dilataional Tracheostomy - our Experience

Percutaneous Dilataional Tracheostomy - our Experience

... The guide wire was passed through the needle Plastic dilator was passed over the guide wire in the ...the guide wire into trachea to dilate the tracheal ...the guide ...

6

Correlation between Femoral Guidewire Position and Tunnel Communication in Double Bundle Anterior Cruciate Ligament Reconstruction

Correlation between Femoral Guidewire Position and Tunnel Communication in Double Bundle Anterior Cruciate Ligament Reconstruction

... femoral guide wires ...tunnel guide wires required to prevent femoral bone tunnel communication in DB-ACL ...femoral guide wire distance and tunnel communication fol- lowing DB-ACL ...tunnel ...

8

Original Article Antigrade Humerus Interlocking Nailing for Diaphyseal Fractures of Humerus: A Study of Clinical Outcomes Prasanth Ganji *, PR Naidu Pothula, Nandam Ramarao, Raj Kumar Vijay, Bharath chandra katragadda, Yeseswi Tellakula.

Original Article Antigrade Humerus Interlocking Nailing for Diaphyseal Fractures of Humerus: A Study of Clinical Outcomes Prasanth Ganji *, PR Naidu Pothula, Nandam Ramarao, Raj Kumar Vijay, Bharath chandra katragadda, Yeseswi Tellakula.

... tipped guide wire was advanced through the entry point into the medullary ...& guide wire was advanced from proximal to distal fragment & confirmed by image intensifier by ...

5

Advances in Angioscopic Imaging of Vascular Disease

Advances in Angioscopic Imaging of Vascular Disease

... a guide wire could not be used, and if used in combination with a guiding ca- theter, a large bore catheter had to be used to allow the fiberscope to pass ...balloon guide catheter was de- vised in ...

18

A new adjustable parallel drill guide for internal fixation of femoral neck fracture: a developmental and experimental study

A new adjustable parallel drill guide for internal fixation of femoral neck fracture: a developmental and experimental study

... cannulated guide wires to the target pos- ition. Three guide wires were inserted in the inverted tri- angle ...first guide wire position was superior to the inner cortex of the inferior ...

5

A novel patient specific three dimensional printed external template to guide iliosacral screw insertion: a retrospective study

A novel patient specific three dimensional printed external template to guide iliosacral screw insertion: a retrospective study

... the guide wire required in one view should necessarily be recon- firmed on all fluoroscopic ...the guide wires using the conventional method increases both intra-operative time and radiation ...

9

Show all 8480 documents...

Related subjects