Vitamin D deficiency in early implant failure: two case reports

Vitamin D deficiency in early implant failure: two case reports

... the failure of implants at a very early stage of osseointegra- tion has been described [1, ...early implant failure is on- going to date and include the following: tobacco usage, diabetes, wear ...

6

Comparison of implant failure rates of different plates for midshaft clavicular fractures based on fracture classifications

Comparison of implant failure rates of different plates for midshaft clavicular fractures based on fracture classifications

... some implant failures could have been ...higher implant failure rate in our study may be due to our inclusion of plate bending as a cause of implant failure, whereas most previous ...

7

Risk factors for implant failure in reverse oblique and transverse intertrochanteric fractures treated with proximal femoral nail antirotation (PFNA)

Risk factors for implant failure in reverse oblique and transverse intertrochanteric fractures treated with proximal femoral nail antirotation (PFNA)

... proper TAD to avoid implant failure [7, 11, 13]. In Baum- gartner’s study, fixation was accomplished with 142 extra- medullary devices and 56 intramedullary devices. The results showed that no cutout ...

8

Neuropsychiatric symptoms following metal on metal implant failure with cobalt and chromium toxicity

Neuropsychiatric symptoms following metal on metal implant failure with cobalt and chromium toxicity

... After MoM hip resurfacing, higher cobalt and chromium concentrations in blood have been associated with struc- tural changes in visual neurological pathways ([12] study of 29 patients, mean age 59 years). There are ...

5

Novel concept of a modular hip implant could contribute to less implant failure in THA: a hypothesis

Novel concept of a modular hip implant could contribute to less implant failure in THA: a hypothesis

... Until now, modularity in THA is mainly applied in revi- sion and tumor arthroplasty [15–18]. In primary THA modular implants are barely used because of the high risk of breakage [11, 19–21]. Another risks in this con- ...

5

Implant Failure - Prosthodontist’s Eye View

Implant Failure - Prosthodontist’s Eye View

... •· During the early phase of healing, complications such as swelling, fistulas, suppuration, early/ late mucosal dehiscence’s, and osteomyelitis can occasionally be present which can lead to disturbance in ...

6

Influence of patient-related characteristics on early migration in calcar-guided short-stem total hip arthroplasty: a 2-year migration analysis using EBRA-FCA

Influence of patient-related characteristics on early migration in calcar-guided short-stem total hip arthroplasty: a 2-year migration analysis using EBRA-FCA

... for implant failure is asep- tic loosening ...predict implant survival ...of implant stability and the increase of interface micromo- tion which, by interfering osteointegration, might ...

9

Comparisons of maximum deformation and failure forces at the implant–abutment interface of titanium implants between titanium-alloy and zirconia abutments with two levels of marginal bone loss

Comparisons of maximum deformation and failure forces at the implant–abutment interface of titanium implants between titanium-alloy and zirconia abutments with two levels of marginal bone loss

... of implant failure into the following six categories: surgery, im- plant loss, bone loss, peri-implant soft tissue, mechanical difficulties, and esthetic/ phonetic problems ...

10

Factors affecting the early failure of implants placed in a dental practice with a specialization in implantology – a retrospective study

Factors affecting the early failure of implants placed in a dental practice with a specialization in implantology – a retrospective study

... the implant sur- face, which results in the development of fibrous scar tis- sue between the implant surface and the surrounding ...the implant site (maxilla or mandible, anterior or posterior) [12, ...

7

A modified dynamic hip screw in unstable intertrochanteric fracture: A retro-prospective study

A modified dynamic hip screw in unstable intertrochanteric fracture: A retro-prospective study

... The primary aim of treatment is stable fixation and early weight bearing mobilization. Stable intertrochanteric fractures can be easily treated by osteosynthesis with predictable good results. Management of unstable ...

99

In-screw polymethylmethacrylate-augmented sacroiliac screw for the treatment of fragility fractures of the pelvis: a prospective, observational study with 1-year follow-up

In-screw polymethylmethacrylate-augmented sacroiliac screw for the treatment of fragility fractures of the pelvis: a prospective, observational study with 1-year follow-up

... A key finding is the pain reduction after 1 year with achieved mobility, which in our opinion, suggests the heal- ing of the fracture. Without any proof, we assume reasons for the increasing distribution of the pain ...

8

Palliative transpedicular partial corpectomy without anterior vertebral reconstruction in lower thoracic and thoracolumbar junction spinal metastases

Palliative transpedicular partial corpectomy without anterior vertebral reconstruction in lower thoracic and thoracolumbar junction spinal metastases

... Previous studies have reported the results of the PTA without anterior reconstruction, but no study had dir- ectly focused on tumors involving T10–L1. Bridwell et al. [17] studied 25 patients with metastatic spine dis- ...

6

Functional Outcomes of Aggressive Giant Cell Tumours of Distal End Radius Managed with Wide Resection & Proximal Fibular Reconstruction

Functional Outcomes of Aggressive Giant Cell Tumours of Distal End Radius Managed with Wide Resection & Proximal Fibular Reconstruction

... recurrence and surgical complications, if any, including infection, implant failure, nonunion, fracture. Residual pain and ability to perform activities daily living [r] ...

8

Open Journal Systems

Open Journal Systems

... of implant failure is the matter of great concern to ...the implant failure ...of implant-supporting bone and diagnosed based on clinical inflammatory symptoms (such as hyperplastic ...

6

Does plate type influence the clinical outcomes and implant removal in midclavicular fractures fixed with 2.7-mm anteroinferior plates? A retrospective cohort study

Does plate type influence the clinical outcomes and implant removal in midclavicular fractures fixed with 2.7-mm anteroinferior plates? A retrospective cohort study

... The clavicle contour and anatomy is curved in multiple planes. The recon plate is easier to contour in all planes than the stiffer DCP, which allows bending only along the length of the plate. For superior plating, a ...

7

A Comparison of the Clinico-Radiological Outcomes with Proximal Femoral Nail (PFN) and Proximal Femoral Nail Antirotation (PFNA) in Fixation of Unstable Intertrochanteric Fractures

Click here to download PDF version of the article !

... to implant failure ...in implant design. The search for an ideal implant for these osteoporotic fractures continues and is evidenced by the variety of nail designs available ...

5

The Effect of Implant Girth and Implant Collar on the Degree of Bone to Implant Contact and Bone Stresses in the Proximal Humerus

The Effect of Implant Girth and Implant Collar on the Degree of Bone to Implant Contact and Bone Stresses in the Proximal Humerus

... optimal implant type remain unsatisfactory (Al-Dirini, ...the implant collar to the calcar is difficult to achieve in the hip (Demey, Fary, Lustig, Neyret, & Si Selmi, 2011; Markolf, Amstutz, & ...

181

Antibiotics prescribing practices in oral implantology among jordanian dentists  A cross sectional, observational study

Antibiotics prescribing practices in oral implantology among jordanian dentists A cross sectional, observational study

... of implant insertion as factors for antibiotic ...of implant failure [35,36], and although the benefit of postoperative administration of antibiotics if preoperative dose had been given was not ...

8

Postoperative complications associated with external skeletal fixators in cats

Postoperative complications associated with external skeletal fixators in cats

... 23 Radius & Ulna Type 1a & IM pin (3,3) Implant failure Loose proximal & distal pins ESF removed as fracture stable. 24 Mandible & maxilla Free-form Implant fai[r] ...

28

Repeated failure of implants at the same site: a retrospective clinical study

Repeated failure of implants at the same site: a retrospective clinical study

... peated failure of implants in certain patients, surviving implants survived for an average of ...repeated implant failure in this study were sex, location in the maxilla or molar area, and ...

9