• No results found

magnetic resonance imaging accuracy

Rambeck, Aurel
  

(2010):


	Knorpelmorphologie des Sprunggelenks bei Geschwistern.


Dissertation, LMU München: Medizinische Fakultät

Rambeck, Aurel (2010): Knorpelmorphologie des Sprunggelenks bei Geschwistern. Dissertation, LMU München: Medizinische Fakultät

... Quantitative relationships of normal cartilage volumes of the human knee joint - assessment by magnetic resonance imaging.. Accuracy of three-dimensional knee joint cartilage volume and[r] ...

71

Diagnostic accuracy of Magnetic Resonance Imaging to differentiate benign and Malignant Parotid Gland Tumors

Diagnostic accuracy of Magnetic Resonance Imaging to differentiate benign and Malignant Parotid Gland Tumors

... standard imaging coil was then carried out. Imaging was further evaluated for the presence or absence of benign or malignant parotid gland tumours using histopathology as a Gold ...diagnostic ...

7

Accuracy of magnetic resonance imaging in detecting lumbo sacral nerve root compromise: a systematic literature review

Accuracy of magnetic resonance imaging in detecting lumbo sacral nerve root compromise: a systematic literature review

... study, the inclusion criteria, description of target condi- tion, index test and reference standard and interpret- ation of test results. Kappa (k) values and P- values were considered as indicators in determining the ...

7

The Accuracy of Magnetic Resonance Imaging in the Diagnosis of Meniscal and Cruciate Ligament Tears of the Knee

The Accuracy of Magnetic Resonance Imaging in the Diagnosis of Meniscal and Cruciate Ligament Tears of the Knee

... meniscus (1,3,28,29). The main argument is whether we should classify this as a false positive MRI result or a false negative result for arthroscopy. Several authors reported that most false positive results with MRI ...

5

Diagnostic Accuracy of MRI in Primary Cervical Cancer

Diagnostic Accuracy of MRI in Primary Cervical Cancer

... Introduction: Magnetic resonance imaging (MRI) studies obtained during the initial staging of patients affected by uterine cervical cancer were compared to the final histological report after ...

8

Multi-detector row computed tomography (MDCT) and magnetic resonance imaging (MRI) in the evaluation of the mandibular invasion by squamous cell carcinomas (SCC) of the oral cavity. Correlation with pathological data

Multi-detector row computed tomography (MDCT) and magnetic resonance imaging (MRI) in the evaluation of the mandibular invasion by squamous cell carcinomas (SCC) of the oral cavity. Correlation with pathological data

... inherent the retrospective design of the study, thus our results need to be confirmed in larger prospective stud- ies. Second, our examinations were conducted with con- ventional MRI image and we are in accordance with ...

8

Diffusion-Weighted Magnetic Resonance Imaging in Term Perinatal Brain Injury: A Comparison With Site of Lesion and Time From Birth

Diffusion-Weighted Magnetic Resonance Imaging in Term Perinatal Brain Injury: A Comparison With Site of Lesion and Time From Birth

... the perinatal timing of an insult, we still have not established whether ADC values will provide data for timing the onset of injury more accurately than is currently possible. Unfortunately, in medicolegal cases, what ...

13

Diagnostic accuracy of magnetic resonance imaging in detecting anterior cruciate ligament injuries

Download Download PDF

... diagnostic accuracy of magnetic resonance imaging (MRI) in detecting ACL injury by taking arthroscopy as gold standard in patients with traumatic knee ...The accuracy, sensitivity and ...

6

Magnetic resonance imaging for detecting root avulsions in traumatic adult brachial plexus injuries: protocol for a systematic review of diagnostic accuracy

Magnetic resonance imaging for detecting root avulsions in traumatic adult brachial plexus injuries: protocol for a systematic review of diagnostic accuracy

... nostic accuracy of MRI may be downwardly biased because patients may have been referred based on MRI findings ra- ther than the presence of symptoms ...diagnostic accuracy and raise con- cerns about ...

6

Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging

Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging

... Previous studies demonstrated high intra- and interob- server reliability of ONSD quantification using transbulbar ultrasound [8,9]. However, data regarding scan-rescan reproducibility of this technique are missing but ...

6

Magnetic Resonance Imaging (MRI) in the Management of Knee Disorders

Magnetic Resonance Imaging (MRI) in the Management of Knee Disorders

... of Magnetic Resonance Imaging (MRI) in the diagnostic investigation of acute and chronic knee injury/disorder is well ...overall accuracy of arthroscopy has been commonly quoted as being ...

74

Diagnostic accuracy of contrast enhanced computed tomography and contrast enhanced magnetic resonance imaging of small renal masses in real practice: sensitivity and specificity according to subjective radiologic interpretation

Diagnostic accuracy of contrast enhanced computed tomography and contrast enhanced magnetic resonance imaging of small renal masses in real practice: sensitivity and specificity according to subjective radiologic interpretation

... CT has traditionally been regarded as the imaging modality of choice to evaluate RCC owing to its fast ac- quisition time and the excellent anatomic detail pro- vided [3]. However, MRI has gained popularity for ...

8

Hip pathology: the diagnostic accuracy of magnetic resonance imaging

Hip pathology: the diagnostic accuracy of magnetic resonance imaging

... Minimal data is available for the diagnosis of liga- mentum teres tears and chondral rim damage. It is also noted that it can be difficult to quantify the degree of damage with conventional imaging [6]. ...

5

Original Article Comparison of magnetic resonance spectroscopy and diffusion weighted imaging in the differentiation of glioma recurrence from radiation necrosis: meta-analysis

Original Article Comparison of magnetic resonance spectroscopy and diffusion weighted imaging in the differentiation of glioma recurrence from radiation necrosis: meta-analysis

... value imaging tool to reveal the metabolism of brain ...distinction accuracy [3, 4, ...diagnostic accuracy of Cho/NAA and/or Cho/Cr ranged between 86 and 91% [3-6, ...diagnostic accuracy for ...

11

Comparison of a New Magnetic Resonance Imaging Protocol and Magnetic Resonance Follow Through in Patients with  Inflammatory Bowel Disease—A Prospective Pilot Study

Comparison of a New Magnetic Resonance Imaging Protocol and Magnetic Resonance Follow Through in Patients with Inflammatory Bowel Disease—A Prospective Pilot Study

... In the current study, the sensitivity for FC was high compared with both MRI protocols. However, it is crucial to remember that the statistics on FC are performed on a per patients basis, whereas in MRI the statistics ...

8

Utility of diffusion-weighted and contrast-enhanced magnetic resonance imaging in diagnosing and differentiating between high- and low-grade uterine endometrial stromal sarcoma

Utility of diffusion-weighted and contrast-enhanced magnetic resonance imaging in diagnosing and differentiating between high- and low-grade uterine endometrial stromal sarcoma

... MR imaging characteristic of high-grade ESS, and this feature was absent in low-grade ...MR imaging yielded significantly higher diagnostic accuracy and specificity in differentiating between ...

12

Magnetic Resonance Perfusion Imaging in the Diagnosis of High Grade Glioma Progression and Treatment Related Changes: A Systematic Review

Magnetic Resonance Perfusion Imaging in the Diagnosis of High Grade Glioma Progression and Treatment Related Changes: A Systematic Review

... DOI: 10.4236/ojmn.2018.83024 298 Open Journal of Modern Neurosurgery as that outlined by Tofts et al. [54] presents several difficulties despite suppos- edly giving greater and more specific physiological insight [61]. ...

24

Clinical significance of cerebrovascular complications in patients with acute infective endocarditis: a retrospective analysis of a 12-year single-center experience

Clinical significance of cerebrovascular complications in patients with acute infective endocarditis: a retrospective analysis of a 12-year single-center experience

... suspected IE, who were admitted to the Cardiovascular Center at Sejong General Hospital between January 2000 and September 2012. We then retrospectively reviewed their medical records. From these 282 patients, 104 pa- ...

9

Preoperative MRI of perianal fistula evaluation and its impact on surgical outcome

Preoperative MRI of perianal fistula evaluation and its impact on surgical outcome

... This is retrospective study for patients who underwent preoperative MRI and surgical interference from April 2015 to Jan 2018. The study protocol was approved by the Local Ethical Committee. All patients who presented ...

10

Diffusion tensor imaging with direct cytopathological validation: characterisation of decorin treatment in experimental juvenile communicating hydrocephalus

Diffusion tensor imaging with direct cytopathological validation: characterisation of decorin treatment in experimental juvenile communicating hydrocephalus

... routine magnetic resonance imaging and magnetic resonance diffusion tensor imaging was conducted and the mean diffusivity, fractional anisotropy, radial and axial diffusivity of ...

15

Show all 10000 documents...

Related subjects