• No results found

microwave breast tumor detection

Breast Tumor Detection System Based on a Compact UWB Antenna Design

Breast Tumor Detection System Based on a Compact UWB Antenna Design

... invasive breast cancer were expected to be diagnosed in women in the ...non-invasive breast cancer as reported by the American Cancer Society, although some risk reduction might be achieved if they are ...

11

UWB Microwave Imaging for Breast Cancer Detection --- Experiments with Heterogeneous Breast Phantoms

UWB Microwave Imaging for Breast Cancer Detection --- Experiments with Heterogeneous Breast Phantoms

... the tumor response are in fact enhancing only the image ...the tumor is not the strongest microwave scatterer in the breast, these algorithms will produce worse results by enhancing other ...

11

Multi-Polarized Microwave Power Imaging Algorithm for Early Breast Cancer Detection

Multi-Polarized Microwave Power Imaging Algorithm for Early Breast Cancer Detection

... diameter tumor was inserted into the breast phantom to investigate the quality of the proposed MPI algorithm, compared to a DMAS, and DAS using the same antenna ...the breast-phantom area ...

15

Electrically Small Magnetic Probe with PCA for Near-Field Microwave Breast Tumors Detection

Electrically Small Magnetic Probe with PCA for Near-Field Microwave Breast Tumors Detection

... for microwave breast cancer detection is ...proposed microwave detection is based on the shift in the resonance frequency of the near-field magnetic probe due to the presence of a ...

10

Breast Cancer Detection Based on Differential Ultrawideband Microwave Radar

Breast Cancer Detection Based on Differential Ultrawideband Microwave Radar

... UWB breast cancer detection ...no tumor is present in either scan (but changes in glandular tissue composition ...cancer detection rates, where the dataset consisted of UWB backscattered data ...

12

Novel Multistatic Adaptive Microwave Imaging Methods for Early Breast Cancer Detection

Novel Multistatic Adaptive Microwave Imaging Methods for Early Breast Cancer Detection

... the breast tissues are Gaussian random variables with a mean equal to their nominal values and a variance equal to ...reported breast tissue variabil- ities [4, ...fatty breast tissue and those of ...

13

Poles Isolation via ESPRIT for Ultra-Wide Band Breast Cancer Imaging

Poles Isolation via ESPRIT for Ultra-Wide Band Breast Cancer Imaging

... paper, microwave breast cancer detection is investigated using the Ultra-Wide Band (UWB) radar imaging ...various breast tissues and investigating the proposed ...the tumor/glandular ...

15

Microwave Time-Reversal Mirror for Imaging and Hyperthermia Treatment of Breast Tumors

Microwave Time-Reversal Mirror for Imaging and Hyperthermia Treatment of Breast Tumors

... common breast cancer detection method [4], disadvantages such as risks associated with radiation exposure [5] and discomfort due to breast muscle compression [6] have motivated researchers to develop ...

16

Study of Correlation Coefficient for Breast Tumor Detection in Microwave Tomography

Study of Correlation Coefficient for Breast Tumor Detection in Microwave Tomography

... Figures 7a-c show the x-axis projection of the setting and reconstruction values of the dielectric properties of the tumor voxel for Model 1 obtained using multi-polarization.. These res[r] ...

10

Experimental Assessment of Microwave Diagnostic Tool for Ultra-Wideband Breast Cancer Detection

Experimental Assessment of Microwave Diagnostic Tool for Ultra-Wideband Breast Cancer Detection

... the breast phantom(fat tissue material) to simulate the heterogeneity ...dense breast (dominance of adipose tissue), to a high dense breast (more heterogeneous mixture of fibro glandular and ...the ...

13

Circulating tumor cells in precision oncology: clinical applications in liquid biopsy and 3D organoid model

Circulating tumor cells in precision oncology: clinical applications in liquid biopsy and 3D organoid model

... Circulating tumor cells (CTCs) are a rare subset of cells found in the blood of patients with solid tumors, which func‑ tion as a seed for ...primary tumor heterogeneity and mimic tumor properties, ...

13

Quantitative assessment of the association between APC promoter methylation and breast cancer

Quantitative assessment of the association between APC promoter methylation and breast cancer

... of tumor suppressors [42]. As we know that APC is a tumor suppressor gene, which can be silenced or inactivated by methylation of CpG islands in gene promoter ...between breast cancer and APC ...in ...

11

Circulating tumor cells, disease recurrence and survival in newly diagnosed breast cancer

Circulating tumor cells, disease recurrence and survival in newly diagnosed breast cancer

... disseminated tumor cells routinely in clinical labora- tories. Detection of tumor cells in the blood is an attractive alternative as a validated method is available and the presence of CTC in ...

8

Image Segmentation and Asymmetry Analysis of Breast Thermograms for Tumor Detection

Image Segmentation and Asymmetry Analysis of Breast Thermograms for Tumor Detection

... A Graphical User Interface is the most common type of user interface seen today. One of the main advantages of creating a standalone GUI is to be able to make it available to a user with no Matlab knowledge [16][17]. ...

6

Cell-free circulating tumor DNA in cancer

Cell-free circulating tumor DNA in cancer

... of tumor‑associated DNA methylation in ctDNA DNA methylation plays pivotal roles in gene regulation and genome ...with tumor initiation, dissemination and metas- tasis establishment, and progression ...

9

Circulating Tumor Cells in Metastatic Breast Cancer: A Prognostic and Predictive Marker

Circulating Tumor Cells in Metastatic Breast Cancer: A Prognostic and Predictive Marker

... representing breast cancer and CTCs produced a broad selection of articles from PubMed and Web of ...nonmetastatic breast cancer, clinical trials using non-IHC based CTC isolation, and studies not reporting ...

9

Flow Cytometric Detection of Circulating Tumor Cells in Breast Cancer Patients: A Blinded Study

Flow Cytometric Detection of Circulating Tumor Cells in Breast Cancer Patients: A Blinded Study

... This study used a highly sensitive technique, flow cytometry, coupled with a multiparameter panel to increase the sensitivity and specificity of CTC detection in breast cancer patients. Compared to previous ...

8

Microwave ablation combined with OK 432 induces Th1 type response and specific antitumor immunity in a murine model of breast cancer

Microwave ablation combined with OK 432 induces Th1 type response and specific antitumor immunity in a murine model of breast cancer

... To further evaluate the specificity of immune response induced by treatments, IFN-γ ELISPOT assays were performed using splenocytes from mice 7 days after ablation. As shown in Fig. 4, the number of 4T1 spe- cific IFN-γ ...

10

Detection of Circulating Tumor Cells in Patients with Breast, Prostate, Pancreatic, Colon and Melanoma Cancer: A Blinded Comparative Study Using Healthy Donors

Detection of Circulating Tumor Cells in Patients with Breast, Prostate, Pancreatic, Colon and Melanoma Cancer: A Blinded Comparative Study Using Healthy Donors

... [10]. Tumor cells were identi- fied by Pan-CK positive selection ...metastatic breast, prostate and melanoma cells were ana- lyzed for expression of c-MET, CD227, prostate-specific membrane antigen (PSMA) ...

11

Science in Focus: Circulating Tumour DNA as a Liquid Biopsy.

Science in Focus: Circulating Tumour DNA as a Liquid Biopsy.

... early detection of microscopic residual disease clinically relevant? Unlike patients with haematological malignancies, overt metastatic disease from the more prevalent solid tumours is almost always ...in ...

6

Show all 10000 documents...

Related subjects