• No results found

Nitinol Stent

Initial Clinical Experience with a New Self Expanding Nitinol Stent for the Treatment of Intracranial Cerebral Aneurysms: The Cordis Enterprise Stent

Initial Clinical Experience with a New Self Expanding Nitinol Stent for the Treatment of Intracranial Cerebral Aneurysms: The Cordis Enterprise Stent

... self-expanding stent technology, because of ease of use, better deliverability, and lower tendency for vessel rupture and damage to the artery during deployment ...of nitinol self-expanding stents designed ...

6

Use of a double-wire woven uncovered nitinol stent for the treatment of refractory tracheal collapse in a dog: a case report H.Y. Yoon 1, J.W. Choi1 , Ji H. Kim 1, Jung H. Kim2

Use of a double-wire woven uncovered nitinol stent for the treatment of refractory tracheal collapse in a dog: a case report H.Y. Yoon 1, J.W. Choi1 , Ji H. Kim 1, Jung H. Kim2

... for stent size selection was performed on thoracic radio- graphs. Stent length and diameter were measured from a level 2 cm caudal to the cricoid cartilage to a level 1 cm cranial to the carina of the ...

7

Study design and rationale of the ‘Balloon Expandable Cobalt Chromium SCUBA Stent versus Self Expandable COMPLETE SE Nitinol Stent for the Atherosclerotic ILIAC Arterial Disease (SENS ILIAC Trial) Trial’: study protocol for a randomized controlled trial

Study design and rationale of the ‘Balloon Expandable Cobalt Chromium SCUBA Stent versus Self Expandable COMPLETE SE Nitinol Stent for the Atherosclerotic ILIAC Arterial Disease (SENS ILIAC Trial) Trial’: study protocol for a randomized controlled trial

... routine stent placement with a PTA strategy has been generally accepted ...after stent placement compared with PTA and the technical success rate was higher after stent placement ...

10

Bare metal stent versus paclitaxel eluting stent for intermediate length femoropopliteal arterial lesions (BATTLE trial): study protocol for a randomized controlled trial

Bare metal stent versus paclitaxel eluting stent for intermediate length femoropopliteal arterial lesions (BATTLE trial): study protocol for a randomized controlled trial

... The BATTLE clinical investigation is a prospective, ran- domized (1:1), controlled, multicentric and international trial in France and Switzerland. All randomized patients will be included in the analysis (intent to ...

9

Permebealidade in Vitro do Stent de Nitinol Revestido com a Membrana Regeneradora Porosa

Permebealidade in Vitro do Stent de Nitinol Revestido com a Membrana Regeneradora Porosa

... uncoated nitinol stent had an average in vitro permeability index of ...the nitinol stent coated with a porous regenerating membrane had an average permeability index of ...the stent, ...

15

Self expanding nitinol stents in canine vertebral arteries: hemodynamics and tissue response

Self expanding nitinol stents in canine vertebral arteries: hemodynamics and tissue response

... the nitinol stent for intra- vascular application are ease of delivery, high expansion ratio (ie, expanded diameter-to-con- strained diameter), and reliable ...NJ), nitinol stents do not require a ...

9

Efficacy of two different self expanding nitinol stents for atherosclerotic femoropopliteal arterial disease (SENS FP trial): study protocol for a randomized controlled trial

Efficacy of two different self expanding nitinol stents for atherosclerotic femoropopliteal arterial disease (SENS FP trial): study protocol for a randomized controlled trial

... or stent implantation in peripheral arterial ...expandable nitinol stent and it seems to be more effect- ive in patients who are at a high risk of restenosis ...undergoing stent implantation ...

11

Nitinol Stenting in Post Traumatic Pseudo Aneurysm of Internal Carotid Artery

Nitinol Stenting in Post Traumatic Pseudo Aneurysm of Internal Carotid Artery

... the nitinol self expanding stents lies in it being a braided ...the stent to the arterial ...the stent midsection and inward crimping of the proximal and distal ends, were shown to not exist in the ...

5

Stent Coil Treatment of a Distal Internal Carotid Artery Dissecting Pseudoaneurysm on a Redundant Loop by Use of a Flexible, Dedicated Nitinol Intracranial Stent

Stent Coil Treatment of a Distal Internal Carotid Artery Dissecting Pseudoaneurysm on a Redundant Loop by Use of a Flexible, Dedicated Nitinol Intracranial Stent

... intracranial nitinol stent (Neuroform, Target/BSC/ Smart therapeutics, Fremont, CA) became commercially avail- ...and stent placement, as well as coil embo- lization of the pseudoaneurysm, was ...

5

Prospecção Tecnológica Sobre a Utilização do Stent de Nitinol Revestido com a Membrana Regeneradora Porosa

Prospecção Tecnológica Sobre a Utilização do Stent de Nitinol Revestido com a Membrana Regeneradora Porosa

... Stents are braided metal structures, with opening at the bottom and top, in the form of mesh, whose function is to maintain the patetedness of the vessel. The present work aimed to carry out a technological prospection ...

12

An Argument for the Use of Multiple Segment Stents in Curved Arteries

An Argument for the Use of Multiple Segment Stents in Curved Arteries

... a stent in the curved artery may also cause vessel straightening ...as stent flexibil- ity ...different stent link elements have been introduced in new stent designs in order to increase ...

5

Stent Fitting using Cylindrical Affine Transformation Model for Pulmonary Artery

Stent Fitting using Cylindrical Affine Transformation Model for Pulmonary Artery

... the stent which is appropriate for given pulmonary ...the stent, outcome is determined by physician experience ...the stent which is too large into an artery can damage it causing arterial dissection ...

6

Bioabsorbable Stent Quo Vadis: A Case for Nano-Theranostics

Bioabsorbable Stent Quo Vadis: A Case for Nano-Theranostics

... bioabsorbable stent may be a promising alternative, providing vessel patency and support for the necessary time required and thereafter degrade into safe non-toxic compounds which are reabsorbed by the ...

20

New developments in the use of prostatic stents

New developments in the use of prostatic stents

... Abstract: Bladder outflow obstruction is a very common age-related clinical entity due to a variety of benign and malignant diseases of the prostate. Surgical treatment under general or regional anesthesia is not ...

6

A prospective and randomized comparison of rigid ureteroscopic to flexible cystoscopic retrieval of ureteral stents

A prospective and randomized comparison of rigid ureteroscopic to flexible cystoscopic retrieval of ureteral stents

... ureteral stent offer the advantage of being less painful in the male patient ...ureteral stent were removed using ureteroscopy were similar to those removed using flexible cystoscopy for both ...ureteral ...

5

Nitinol Spinal Vertebrae: A Favorable New Substitute

Nitinol Spinal Vertebrae: A Favorable New Substitute

... of Nitinol nails in rats has shown no adverse effect ...the Nitinol SMA. Nitinol rings can also serve spinal surgeries in the same way as clamps which are used for quick ...increases. Nitinol ...

10

The modified pancreatic stent system for prevention of post-ERCP pancreatitis: a case-control study

The modified pancreatic stent system for prevention of post-ERCP pancreatitis: a case-control study

... pancreatic stent placement and the efficacy of drugs, such as diclofenac, somato- statin, and nonsteroidal anti-inflammatory drugs to re- duce the incidence of PEP ...pancreatic-duct stent placement ...

8

Confection and Assessment of a Dynamic Orthotics Using a Nitinol Alloy

Confection and Assessment of a Dynamic Orthotics Using a Nitinol Alloy

... At this stage of the study the objective was developing a testing device for different types of Nitinol in order to assess the memory shape alloy properties. The testing device was used to gather data about the ...

6

AlliumTM Bulbar Urethral Stent: An Updated Long Term Multi Center Study with New Treatment Modality for Bulbar Urethral Stricture

AlliumTM Bulbar Urethral Stent: An Updated Long Term Multi Center Study with New Treatment Modality for Bulbar Urethral Stricture

... expandable nitinol urethral stent ...early stent removal. The most common complication requiring re- moval was stent migration, which occurred in 9%, of them two patients had their stents ...

6

A novel polymer-free ciglitazone-coated vascular stent: in vivo and ex vivo analysis of stent endothelialization in a rabbit iliac artery model

A novel polymer-free ciglitazone-coated vascular stent: in vivo and ex vivo analysis of stent endothelialization in a rabbit iliac artery model

... Each stent section was analysed for strut apposition, fibrin deposition, granuloma reactions, mineralization and ...between stent struts were semi-quantified and expressed as the percentage of the lumen ...

10

Show all 897 documents...