• No results found

non-invasive measurement

Computer methods for non-invasive measurement and control of two-phase flows: a review study

Computer methods for non-invasive measurement and control of two-phase flows: a review study

... Most of the research works based on the tomographic techniques have implemented the image reconstruc- tion methods. In many industrial applications sup- ported by the tomographic diagnosis, beside the accu- rate ...

23

Ultrasound for the non-invasive measurement of internal combustion engine piston ring oil films

Ultrasound for the non-invasive measurement of internal combustion engine piston ring oil films

... Unless indicated otherwise, fulltext items are protected by copyright with all rights reserved. The copyright exception in section 29 of the Copyright, Designs and Patents Act 1988 allows the making of a single copy ...

18

Ultrasound for the non-invasive measurement of IC engine piston skirt lubricant films

Ultrasound for the non-invasive measurement of IC engine piston skirt lubricant films

... The hostile conditions of an engine (vibration, tem- peratures, inertial loading, etc.) present a significant challenge to the investigator. A number of techniques have been used to measure the skirt film thickness, but ...

11

Simulation Analysis for Non-invasive Measurement for Hemodynamics in Cerebral Arteriovenous Malformation Types

Simulation Analysis for Non-invasive Measurement for Hemodynamics in Cerebral Arteriovenous Malformation Types

... The Type IIIb is the type of CAVM which are dilated in nature. This type of CAVM has multiple combinations of arteries which are dilated and interconnected to multiple dilated draining veins (Fig. 4). The dilation causes ...

10

Non invasive measurement of a metabolic marker of infant brain function

Non invasive measurement of a metabolic marker of infant brain function

... this non-invasive, infant friendly way, holds great potential for future research to further our understanding of atypical development in clinical ...

7

Non invasive measurement of chick embryo cardiac work

Non invasive measurement of chick embryo cardiac work

... the non-invasive method of chick embryo car- diac work registration, an eggshell with electric charges on it is one capacitor plate, the other being a receiving antenna of the measuring ...

8

Non Invasive Blood Glucose Measurement using NIR technique based on occlusion spectroscopy

Non Invasive Blood Glucose Measurement using NIR technique based on occlusion spectroscopy

... Abstract—Diabetes is considered to be one of the major health care epidemics of modern era. The determination of blood glucose concentration using the self monitoring blood glucose devices involves the chemical analysis ...

9

Blood pulsation measurement using cameras operating in visible light: limitations

Blood pulsation measurement using cameras operating in visible light: limitations

... for non-contact and non-invasive measurement; (2) it can be carried out using almost any camera, including webcams; (3) it enables to track the object on the stage, which allows for the ...

15

Development Of Msp Based Pulse Oximeter With Labview

Development Of Msp Based Pulse Oximeter With Labview

... The noninvasive measurement of pulse oximetry used for the of arterial oxygen saturation in the blood. Pulse oximetry derives SpO2 and pulse rate from a photoplethysmogram (PPG). The PPG is obtained ...

5

Exhaled 8-isoprostane in childhood asthma

Exhaled 8-isoprostane in childhood asthma

... the non-enzymatic peroxidation. This elevation in exhaled 8-isoprostane in steroid-treated asthmatics is con- sistent with the studies of other authors [14,15]. In our study, it can be seen that eNO and ...

6

Non-Invasive Ocular Rigidity Measurement: A Differential Tonometry Approach

Non-Invasive Ocular Rigidity Measurement: A Differential Tonometry Approach

... accurate non-invasive measurement of OR has been the target of various research projects so far (1, 3, 7, ...a non-invasive quantitative method to assess OR as the ...

6

Non invasive assessment of airway inflammation in asthma : a thesis by publications presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Public Health, Massey University, Wellington, New Zealand

Non invasive assessment of airway inflammation in asthma : a thesis by publications presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Public Health, Massey University, Wellington, New Zealand

... A population of 107 healthy and asthmatic individuals were recruited from colleagues of the three research institutes involved. The study was approved by the regional ethics committee and written informed consent was ...

325

Non-invasive monitoring of oxygen delivery in acutely ill patients: new frontiers

Non-invasive monitoring of oxygen delivery in acutely ill patients: new frontiers

... Importantly, SpHb monitoring is not yet as accurate as laboratory hemoglobin, and it is therefore not intended today as its replacement. Its value-added benefits should be considered as supplementing intermittent, ...

8

Current Possibilities to Assess the Degree of Liver Fibrosis in Patients with Haemophilia Infected with HCV – Review

Current Possibilities to Assess the Degree of Liver Fibrosis in Patients with Haemophilia Infected with HCV – Review

... of non-invasive methods that are particularly useful in patients with bleeding ...minimally invasive assessment of liver disease progression and classification of the patient to the appropriate ...

7

Prognostic Value of Dynamic Tissue Perfusion Measurements in Transplanted Kidneys

Prognostic Value of Dynamic Tissue Perfusion Measurements in Transplanted Kidneys

... Perfusion Measurement (DTPM) of the renal transplant’s cortex is a non-invasive method to describe renal transplants’ cortical perfusion and has demonstrated its performance in normal kidneys as well ...

5

Blood pressure measurement in obese patients: non-invasive proximal forearm versus direct intra-arterial measurements

Blood pressure measurement in obese patients: non-invasive proximal forearm versus direct intra-arterial measurements

... Notes: MAP = mean arterial pressure; ALine = direct arterial blood pressure measurements; NIBP = non-invasive blood pressure measurements.Abscissa: mean of Aline and NIBP measurement pairs. Ordinate: ...

5

ABSTRACT : Haemoglobin is the most important parameter in blood cells of human body. Haemoglobin is the protein

ABSTRACT : Haemoglobin is the most important parameter in blood cells of human body. Haemoglobin is the protein

... optical non contact type sensor for haemoglobin measurement is ...between invasive and non-invasive is measurement with in a ...

5

Development of a video signal based 
		non invasive method for measurement of turbulent flame temperature

Development of a video signal based non invasive method for measurement of turbulent flame temperature

... Present investigation explores the application of video processing in non-contact type temperature measurement for turbulent flames. Average flame features for a small time period are compared with actual ...

7

Preventing Diabetes Extremity Vascular Disease with Blood Oxygen Saturation Images

Preventing Diabetes Extremity Vascular Disease with Blood Oxygen Saturation Images

... Diabetes is a chronic diseas e indicating abnormal metabolism. Recently, ageing populations and dietary and lifestyle changes have increased the annual incidence rate of diabetes and lowered the age of onset. Because ...

7

In vivovalidation of a new non invasive continuous ventricular stroke volume monitoring system in an animal model

In vivovalidation of a new non invasive continuous ventricular stroke volume monitoring system in an animal model

... a non-invasive, precise, continuous, and operator- independent technique of CO ...even non-inva- sive techniques have been developed. Non-invasive ultrasound Doppler techniques like ...

8

Show all 10000 documents...

Related subjects