• No results found

reverberation chamber

Characterization of vibrating intrinsic reverberation chamber and comparison
with classical reverberation chamber for antenna efficiency measurements

Characterization of vibrating intrinsic reverberation chamber and comparison with classical reverberation chamber for antenna efficiency measurements

... decades, Reverberation Chambers (RC) have established themselves as an useful and accurate testing and characterization tool for measurements of a wide range of devices and figures of merit with applications in ...

59

Statistical Analysis of Electromagnetic Field Inside a Jet Engine Using the Reverberation Chamber Approach

Statistical Analysis of Electromagnetic Field Inside a Jet Engine Using the Reverberation Chamber Approach

... A simplified jet engine model has been analyzed using HFSS by dividing the position of the rotating blades in 90 different angles. The field inside the jet engine has been analyzed using a statistical approach derived by ...

9

Broadband Measurement of Absorption Cross-Section of the Human Body in a Reverberation Chamber

Broadband Measurement of Absorption Cross-Section of the Human Body in a Reverberation Chamber

... Measurements were taken in a reverberation chamber with dimensions 4.70m  3.00m  2.37m and a lowest usa- ble frequency (LUF) of 200MHz [24], using two double ridged waveguide horn antennas. These were ...

10

Predicting theater chair absorption from reverberation chamber measurements   comment

Predicting theater chair absorption from reverberation chamber measurements comment

... measuring reverberation time before and after seat installation) with measurements of the same seating in an ISO reverberation ...of reverberation chamber seat absorption with sample ...

11

On Simulating the Radio Signal Propagation in the Reverberation Chamber with the Ray Launching Method

On Simulating the Radio Signal Propagation in the Reverberation Chamber with the Ray Launching Method

... the reverberation chamber model, such as the wall reflectivity loss, the receive probe size or the number o reflections — all in order to achieve convergence between outcomes obtained in the real ...

17

Doppler Spread Spectrum of a Circularly Moving Receiver in an Anechoic and a Reverberation Chamber

Doppler Spread Spectrum of a Circularly Moving Receiver in an Anechoic and a Reverberation Chamber

... The Doppler effect can be emulated using a channel emulator or several mode stirrers in an AC (Anechoic Chamber) and a RC (Reverberation Chamber) [6, 7]. The Doppler emulation methods in [6] have ...

8

A New Method of Evaluating Reverberation Chamber Q-Factor with Experimental Validation

A New Method of Evaluating Reverberation Chamber Q-Factor with Experimental Validation

... a reverberation chamber, this contribution proposes a new kind of methods for the Q-factor estimation, which can simplify the procedure of measuring Q-factor in experiment and raise the efficiency of ...

10

Measurement of Zigbee Wireless Communications in Mode-Stirred and Mode-Tuned Reverberation Chamber

Measurement of Zigbee Wireless Communications in Mode-Stirred and Mode-Tuned Reverberation Chamber

... loss chamber has more reliable communication channels, but even with loading there are large variations in packet error rates even between adjacent ZigBee ...

8

On Measurement of Reverberation Chamber Time Constant and Related Curve Fitting Techniques

On Measurement of Reverberation Chamber Time Constant and Related Curve Fitting Techniques

... A reverberation chamber (RC) is a cavity loaded with a moving stirrer whose shape and size are carefully designed in order to create a stochastic field ...

8

Rayleigh Fading Channel Characterization Using K-Band FMCW Radar in Reverberation Chamber

Rayleigh Fading Channel Characterization Using K-Band FMCW Radar in Reverberation Chamber

... increase in the number of absorbers. After the excess delay time of 6 µ s, the received power slowly decreases, and the PDPs becomes flat. The measured mean excess delay time and RMS delay spread for all the four cases ...

9

Estimate of the Shielding Effectiveness of an Electrically Large Enclosure Made with Pierced Metallic Plate in a Well-Stirred Reverberation Chamber

Estimate of the Shielding Effectiveness of an Electrically Large Enclosure Made with Pierced Metallic Plate in a Well-Stirred Reverberation Chamber

... In this document, the shielding effectiveness of an electrically large enclosure made with pierced metallic plate was calculated and measured under uniform and isotropic field conditions. The calculation regards TCSs of ...

12

Mode Stirred Reverberation Chamber (Msrc): a Large and Efficient Tool to Lead High Frequency Bioelectromagnetic in Vitro Experimentation

Mode Stirred Reverberation Chamber (Msrc): a Large and Efficient Tool to Lead High Frequency Bioelectromagnetic in Vitro Experimentation

... Stirred Reverberation Chamber (MSRC) was used to expose animals to an electromagnetic environment [12, 13]. Recent works showed great interest in MSRC for the in vivo high frequency electromagnetic ...

34

Statistical distributions of the re-radiated spectrum from two correlated non-linear devices in a reverberation chamber

Statistical distributions of the re-radiated spectrum from two correlated non-linear devices in a reverberation chamber

... orcid.org/0000-0003-3153-8447 et al. (1 more author) (2011) Statistical distributions of the re-radiated spectrum from two correlated non-linear devices in a reverberation chamber. In: 2011 IEEE ...

6

Rapid and accurate broadband absorption cross-section measurement of human bodies in a reverberation chamber

Rapid and accurate broadband absorption cross-section measurement of human bodies in a reverberation chamber

... The measurement of the electromagnetic absorption cross-section (ACS) of human subjects is required for a number of applications which include the estimation of the effects of human subjects on electromagnetic wave ...

14

Shielding Effectiveness Measurements on Enclosures with Various Apertures by Both Mode-Tuned Reverberation Chamber and Gtem Cell Methodologies

Shielding Effectiveness Measurements on Enclosures with Various Apertures by Both Mode-Tuned Reverberation Chamber and Gtem Cell Methodologies

... reverberation chamber. Moreover, the SE results by the reverberation chamber were generally larger than those by the GC, which is mainly due to the random polarization and statistical average ...

12

On the measureable range of absorption cross-section in a reverberation chamber

On the measureable range of absorption cross-section in a reverberation chamber

... a reverberation chamber of specified geometry within a given uncertainty when stepped mechanical tuning and frequency tuning are ...both reverberation chambers and experiments to achieve optimum ...

9

Evaluation and Measurement of the Doppler Spectrum in a Reverberation Chamber

Evaluation and Measurement of the Doppler Spectrum in a Reverberation Chamber

... The RC used in this paper is the Bluetest HP reverberation chamber, with a size of 1.75 m × 1.25 m × 1.8 m. A drawing of it is shown in Fig. 1. It has two plate mode-stirrers, a turn-table platform (on ...

11

Model Selection for Investigation of the Field Distribution in a Reverberation Chamber

Model Selection for Investigation of the Field Distribution in a Reverberation Chamber

... The reverberation chamber (RC) has been used for electromagnetic compatibility (EMC) tests as well as over-the-air (OTA) measurements of wireless devices ...

15

Statistical behavior of transmit antenna 
		orientation in a reverberation chamber

Statistical behavior of transmit antenna orientation in a reverberation chamber

... A reverberation chamber is a cavity resonator whose fields are perturbed by a stirrer in order to generate fields that are statistically uniform and ...the reverberation chamber as compared to ...

5

Absorption cross section of building materials at mm wavelength in a reverberation chamber

Absorption cross section of building materials at mm wavelength in a reverberation chamber

... In Figure 4 and Figure 5 the results obtained for the Q factor and ACS are plotted. The thick lines are obtained as ensemble average of the thin (shaded) lines: this is a usual procedure to mitigate the large spectral ...

14

Show all 2080 documents...

Related subjects