• No results found

Revision hip arthroplasty

Safe surgical technique: iliac osteotomy via the anterior approach for revision hip arthroplasty

Safe surgical technique: iliac osteotomy via the anterior approach for revision hip arthroplasty

... performed hip arthroplasty via the anterior approach (AA) in 1947 on an orthopaedic ...AA hip arthroplasty. While primary AA total hip arthroplasty techniques have been discussed ...

10

No red cell alloimmunization or change of clinical outcome after using fresh frozen cancellous allograft bone for acetabular reconstruction in revision hip arthroplasty: a follow up study

No red cell alloimmunization or change of clinical outcome after using fresh frozen cancellous allograft bone for acetabular reconstruction in revision hip arthroplasty: a follow up study

... Our study revealed 100% graft remodeling and only one case of significant acetabular component migration (6 mm migration with no clinical symptoms, no surgical revision necessary) at a mean follow up of 23 months. ...

5

Revision hip arthroplasty prosthesis: a study implant stability

Revision hip arthroplasty prosthesis: a study implant stability

... Abstract Revision total hip replacement has high rates of fail- ure, which appear to be due in part to deficient bone stock that does not provide an adequate environ- ment for implant ...total hip ...

5

A technique to remove a well-fixed titanium-coated rm acetabular cup in revision hip arthroplasty

A technique to remove a well-fixed titanium-coated rm acetabular cup in revision hip arthroplasty

... In revision hip surgery, the removal of well-fixed cementless components can be extremely demanding, time consuming, and requiringes patience and caution to limit the amount of host bone ...

5

Reduced re infection rates with postoperative oral antibiotics after two stage revision hip arthroplasty

Reduced re infection rates with postoperative oral antibiotics after two stage revision hip arthroplasty

... two-stage revision THA may reduce periprosthetic hip re- infection rates in the hopes of encouraging further, more rigorous studies of this nature in the ...2-stage revision arthroplasty have ...

7

Intraoperative Fracture of the Femur in Revision Total Hip Arthroplasty with a Fully HA Coated Stem

Intraoperative Fracture of the Femur in Revision Total Hip Arthroplasty with a Fully HA Coated Stem

... during revision hip arthroplasty is to achieve good implant fixation despite bone defects, poor bone quality and variable canal ...during revision hip arthroplasty is a ...

7

The effect of endoskeleton on antibiotic impregnated cement spacer for treating deep hip infection

The effect of endoskeleton on antibiotic impregnated cement spacer for treating deep hip infection

... as hip compression screw, in the cement spacer could decrease the cement spacer fracture and hence to improve the interim func- tional ...of hip joint. The soft tissue envelope of hip joint might ...

7

Stem diameter and rotational stability in revision total hip arthroplasty: a biomechanical analysis

Stem diameter and rotational stability in revision total hip arthroplasty: a biomechanical analysis

... of revision hip arthroplasty using extensively porous-coated stems, Paprosky et al reported a survivor- ship of greater than 95% and a low ...of revision total hip arthroplasty ...

7

REVISION TOTAL HIP ARTHROPLASTY

REVISION TOTAL HIP ARTHROPLASTY

... underwent revision hip arthroplasty – that is exchange or removal of one or both components as the end point for failure of primary total hip ...and revision hip replacement was ...

8

Operative diagnosis for revision total hip arthroplasty is associated with patient reported outcomes (PROs)

Operative diagnosis for revision total hip arthroplasty is associated with patient reported outcomes (PROs)

... We found that diagnosis of dislocation/fracture/in- stability/non-union and failed prior arthroplasty/infec- tion were associated with 2- and 1.6-times the risk of moderate-severe ADL limitation 2-years ...

7

Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty

Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty

... a revision arthroplasty performed for recurrent dislocation had changed position, but was stable in the new ...postoperative hip stability depends on several factors other than design-related ones, ...

5

Investigation in failure analysis and materials selection in total hip replacement prosthesis

Investigation in failure analysis and materials selection in total hip replacement prosthesis

... Periprosthetic fractures may occur intraoperatively (during THR procedure) or postoperatively (after THR procedure). It presents with pain, swelling, deformity, instability to use the limb, etc… To diagnose fracture, ...

86

Revision Total Knee Arthroplasty using a Novel 3D Printed Titanium Augment: A Cadaveric Biomechanical Study

Revision Total Knee Arthroplasty using a Novel 3D Printed Titanium Augment: A Cadaveric Biomechanical Study

... of revision at only 3 years after surgery (Canadian Institute for Health Information, ...requiring revision TKA because of their higher functional demands, which creates additional stress on the ...

176

Proximal Femoral Allograft in Two Stage Revision for Failed Septic Hip Arthroplasty

Proximal Femoral Allograft in Two Stage Revision for Failed Septic Hip Arthroplasty

... The spacer provided stability to the hip. Early postoperative mobilization and wandering without weight- bearing were allowed. Moreover, second-stage procedures were made easy thanks to good spacer exposure. Our ...

11

Improving quality of care through patient reported outcome measures (PROMs): expert interviews using the NHS PROMs Programme and the Swedish quality registers for knee and hip arthroplasty as examples

Improving quality of care through patient reported outcome measures (PROMs): expert interviews using the NHS PROMs Programme and the Swedish quality registers for knee and hip arthroplasty as examples

... Swedish Hip Quality Register (SHPR) and Swedish Knee Arthroplasty Register (SKAR) were used as ...The Hip and Knee Arthroplasty Register were chosen for comparative reasons with the NHS PROMs ...

13

Trends in incidence and outcomes of revision total hip arthroplasty in Spain: A population based study

Trends in incidence and outcomes of revision total hip arthroplasty in Spain: A population based study

... for revision we believe that the use of specialised ‘ revision-implants ’ is in part responsible of the large increase in the average cost per patient overtime in ...

10

The course of radiographic loosening, pain and functional outcome around the first revision of a total hip arthroplasty

The course of radiographic loosening, pain and functional outcome around the first revision of a total hip arthroplasty

... post- revision walking underlines the fact that patients’ expecta- tions should be modest with regards to the potential for walking capacity improvement after the first revision of a ...

6

Fungal periprosthetic joint infection following total elbow arthroplasty: a case report and review of the literature

Fungal periprosthetic joint infection following total elbow arthroplasty: a case report and review of the literature

... resection arthroplasty for chronic Aspergillosis, she was systemically well and had been off of antimicrobials for 5 ...resection arthroplasty in April 2014 and no further spec- imens had been ...

8

Clinically important improvement thresholds for Harris Hip Score and its ability to predict revision risk after primary total hip arthroplasty

Clinically important improvement thresholds for Harris Hip Score and its ability to predict revision risk after primary total hip arthroplasty

... in arthroplasty trials will allow future trials to be adequately powered to examine group-level differences in patient-level outcome assessment on ...Mayo Hip Score [15], that is patient- administered, not ...

8

Risk factors for failure of revision total hip arthroplasty using a Kerboull type acetabular reinforcement device

Risk factors for failure of revision total hip arthroplasty using a Kerboull type acetabular reinforcement device

... consecutive revision THAs (86 patients) for aseptic loosening using cemented acetabular com- ponents with a KT acetabular reinforcement device (KT plate; KYOCERA Medical Corporation, Kyoto, Japan) were performed ...

6

Show all 5018 documents...

Related subjects