• No results found

Simulated Body Fluid

Effect of TiO2 nano-particles on corrosion behavior of Co-Cr alloy coatings in simulated body fluid

Effect of TiO2 nano-particles on corrosion behavior of Co-Cr alloy coatings in simulated body fluid

... Co-Cr and Co-Cr/nano-TiO 2 coatings were electrodeposited from Cr(III) based baths. The effect of TiO 2 nano-particles incorporation on the morphology, structure, crystallite size, and preferred orientation was studied. ...

7

Characterization of Plasma Sprayed Hydroxyapatite Coatings on AISI 316L SS and Titanium Substrate and their Corrosion Behavior in Simulated Body Fluid

Characterization of Plasma Sprayed Hydroxyapatite Coatings on AISI 316L SS and Titanium Substrate and their Corrosion Behavior in Simulated Body Fluid

... The corrosion resistance of HA coatings on various metallic substrates in different physiological solutions has been investigated by many researchers [4-8]. Kwok et al. reported that HA coated Ti-6Al-4V possessed higher ...

9

Corrosion Passivation in Simulated Body Fluid of Magnesium/Hydroxyapatite Nanocomposites Sintered by High Frequency Induction Heating

Corrosion Passivation in Simulated Body Fluid of Magnesium/Hydroxyapatite Nanocomposites Sintered by High Frequency Induction Heating

... the body must be able to withstand corrosion in a biological environment and endure use for years without undue wear (and without causing damage to surrounding ...human body fluid or blood plasma has ...

16

Biodegradability and Surface Chemistry of AZ31D Compared with AZ91 Magnesium Alloy in a Modified Simulated Body Fluid

Biodegradability and Surface Chemistry of AZ31D Compared with AZ91 Magnesium Alloy in a Modified Simulated Body Fluid

... In the previous study, the biodegradable behavior of three kinds of magnesium has been investigated [11], In order to further understand if the minor change of microstructure and composition influence the biodegradation ...

19

Characterization and Corrosion Behavior of Plasma Sprayed Pure and Reinforced HA Coatings in Simulated Body Fluid

Characterization and Corrosion Behavior of Plasma Sprayed Pure and Reinforced HA Coatings in Simulated Body Fluid

... Tafel polarization curves of pure and reinforced as sprayed and post coating heat treated coatings are presented in Fig. 3(a) and 3(b) respectively. The range of passivation potential for bare SS- 304L substrate, pure HA ...

11

Investigation on microstructure, surface and corrosion characteristics of heat treated AISI 420 martensitic stainless steel laser welds in simulated body fluid (SBF)

Investigation on microstructure, surface and corrosion characteristics of heat treated AISI 420 martensitic stainless steel laser welds in simulated body fluid (SBF)

... human body as implants ...using Simulated Body Fluid by an in vitro test is one of these methods [13, ...in Simulated Body Fluid ...

18

Evaluation of Bioactive Properties of α and β Wollastonite Bioceramics Soaked in a Simulated Body Fluid

Evaluation of Bioactive Properties of α and β Wollastonite Bioceramics Soaked in a Simulated Body Fluid

... method, varying the pressing load and sintering temperature, in order to ob- tain different phases of wollastonite, and different physical properties in the materials. The products were characterized by TGA-DTA, XRD, ...

14

Effect of incubation in simulated body fluid on dielectric and photoluminescence properties of nano hydroxyapatite ceramic doped with strontium ions

Effect of incubation in simulated body fluid on dielectric and photoluminescence properties of nano hydroxyapatite ceramic doped with strontium ions

... [4] Pecheva, E.V., Pramatarova, L.D., Maitz, M.F., Pham, M.T. and Kondyuirin, A.V. (2004) Kinetics of hydro- xyapatite deposition on solid substrates modified by se- quential implantation of Ca and P ions. Part II: ...

10

Biodegradation of AZ31 and WE43 Magnesium Alloys in Simulated Body Fluid

Biodegradation of AZ31 and WE43 Magnesium Alloys in Simulated Body Fluid

... Biodegradation behavior and mechanism of AZ31 and WE43 magnesium alloys have been studied in the simulated body fluid (SBF). The results of weight loss tests indicate that corrosion rates of AZ31 ...

11

Initial Electrochemical Activity of Magnesium Alloy
AZ31 Surface Exposed to Simulated Body Fluid by
Scanning Electrochemical Microscopy

Initial Electrochemical Activity of Magnesium Alloy AZ31 Surface Exposed to Simulated Body Fluid by Scanning Electrochemical Microscopy

... This study applies scanning electrochemical microscopy (SECM) in feedback mode to monitor the initial activity of AZ31 magnesium alloy surface, exposed to simulated body fluid (SBF). The alloy ...

6

In situ Investigation of the Initial Stages of AZ91D Magnesium Alloy Biodegradation in Simulated Body Fluid

In situ Investigation of the Initial Stages of AZ91D Magnesium Alloy Biodegradation in Simulated Body Fluid

... Magnesium alloys have recently been considered as very promising materials for biodegradable and resorbable medical implants. Despite this work, there are very few studies that use micro- electrochemical techniques for ...

10

Effect of silver based products on simulated body fluid

Effect of silver based products on simulated body fluid

... Gastric fluid is vital fluids in ...of simulated gastric fluid (SGF) as model of gastric fluid on the structures of SBPs was the second ...

18

In Vitro Bioactivity and Corrosion Properties of Laser Beam Welded Medical Grade AISI 316L Stainless Steel in Simulated Body Fluid

In Vitro Bioactivity and Corrosion Properties of Laser Beam Welded Medical Grade AISI 316L Stainless Steel in Simulated Body Fluid

... In the case that stainless steel is used as an orthopedic implant, stainless steels are biologically tolerated and no chemical bonds. Hydroxyapatite (HA) coating deposited on stainless steels improve osseointegration, ...

16

Friction Wear Properties of Nickel Free Co  Cr  Mo Alloy in a Simulated Body Fluid

Friction Wear Properties of Nickel Free Co Cr Mo Alloy in a Simulated Body Fluid

... Pin-on-flat type friction-wear test was performed accord- ing to ASTM Standard F-732-82. The design of instrument for reciprocating friction test used in this study is shown in Fig. 1. Fixture for the pin also consists of ...

5

Mechanical Properties of CaSiO3/Ti3SiC2 Composites and Hydroxyapatite Forming Ability in Simulated Body Fluid

Mechanical Properties of CaSiO3/Ti3SiC2 Composites and Hydroxyapatite Forming Ability in Simulated Body Fluid

... these materials which show superior bioactivity. Studies have shown that pure CS powders induced formation of a hydroxyapatite (HAp) layer on their surface after soaking in simulated body fluid (SBF) or in ...

5

Fatigue Property of Nickel Free High Nitrogen Austenitic Stainless Steels in Simulated Body Fluid

Fatigue Property of Nickel Free High Nitrogen Austenitic Stainless Steels in Simulated Body Fluid

... nickel (Ni) which is a rare metal, is expected to contribute to resource conservation and promotion of recycling. Studies have been conducted on application of high nitrogen steel to equipment for oil exploration, ...

8

Corrosion Behavior of Ni-Cr Based Coatings in Simulated Human Body Fluid Environment

Corrosion Behavior of Ni-Cr Based Coatings in Simulated Human Body Fluid Environment

... Ni20Cr metallic coatings in simulated body fluid environment. Hank´s solution was used for simulating body fluid environment. Coatings were deposited on to AISI 304-type stainless steel ...

12

DEVELOPMENT OF CONTROLLED RELEASE FORMULATION OF AN ANTIEMETIC DRUG USING NOVEL PARENTERAL DRUG DELIVERY SYSTEMS

DEVELOPMENT OF CONTROLLED RELEASE FORMULATION OF AN ANTIEMETIC DRUG USING NOVEL PARENTERAL DRUG DELIVERY SYSTEMS

... all prerequisites of a parenteral product. The in vitro drug release was found to be over 95% in Simulated Body fluid pH 7.4 at 37°C over a prolong period of 5days and the invivo pharmacokinetic ...

19

In Vitro Bioactivity Evaluation Of Novel Manganese Modified Calcium Silicate Ceramics For One Regeneration

In Vitro Bioactivity Evaluation Of Novel Manganese Modified Calcium Silicate Ceramics For One Regeneration

... into simulated body fluid for two ...in simulated body fluid had indicated that all samples could induce calcium phosphate layer and imply the possibility of applying manganese ...

6

Bacterial Cellulose Templates for Nano-Hydroxyapatite Fibre Synthesis

Bacterial Cellulose Templates for Nano-Hydroxyapatite Fibre Synthesis

... Guided bone regeneration is a medical procedure which induces in vivo re-growth of bone using membranes and osteopromoting fillers. In this work, bacterial cellulose fibres were isolated and used as a basis for ...

132

Show all 10000 documents...