• No results found

stent-graft

Initial experience with a new fenestrated stent graft

Initial experience with a new fenestrated stent graft

... Anaconda stent graft system used in this study is a modular device com- posed of a fenestrated main body and two iliac extension ...the stent graft deployment system. The main body of the ...

7

Application and Numerical Analysis of a New Type of Internal Iliac Stent Graft in the Treatment of Arterial Diseases

Application and Numerical Analysis of a New Type of Internal Iliac Stent Graft in the Treatment of Arterial Diseases

... iliac stent graft (SG) was inserted into the iliac artery by means of intervention, and the SG is compressed ...the stent, and the most vulnerable position was the configuration of the proximal wave ...

5

Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

... Conclusion: The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial ...

5

Treatment of Iatrogenic Internal Carotid Artery Laceration and Carotid Cavernous Fistula with Endovascular Stent Graft Placement

Treatment of Iatrogenic Internal Carotid Artery Laceration and Carotid Cavernous Fistula with Endovascular Stent Graft Placement

... of stent-grafts within the ICA is the limited longitudinal flexibility of the ...semirigid stent-graft designed for coronary use to the curves of the ICA is somewhat ...the stent with the ...

5

Bare Stent Graft Technique: A New Method of Endoluminal Vascular Reconstruction for the Treatment of Giant and Fusiform Aneurysms

Bare Stent Graft Technique: A New Method of Endoluminal Vascular Reconstruction for the Treatment of Giant and Fusiform Aneurysms

... cover stent in the treatment of an acute carotid blowout ...intravascular stent graft treatment of a ruptured fusiform dissecting aneurysm of the intracranial vertebral ...that stent ...

7

Open stent graft repair with upper-half Sternotomy for blunt thoracic aortic injury: a case report

Open stent graft repair with upper-half Sternotomy for blunt thoracic aortic injury: a case report

... open stent grafting, the proximal end of the open stent graft is directly sutured to the native aorta, which may reduce the risk of endoleakage ...

5

Angiographic Follow Up of Traumatic Carotid Cavernous Fistulas Treated with Endovascular Stent Graft Placement

Angiographic Follow Up of Traumatic Carotid Cavernous Fistulas Treated with Endovascular Stent Graft Placement

... covered stent grafts for the treatment of in- tracranial aneurysms, our anticoagulant and antiplatelet pro- tocol consists of starting double antiplatelet therapy (aspirin and ticlopidine or clopidogrel) 4 days ...

6

Open triple-branched stent graft placement for the surgical treatment of acute aortic arch dissection

Open triple-branched stent graft placement for the surgical treatment of acute aortic arch dissection

... branched stent graft from January 2011 and October ...triple-branched stent graft because they satisfied follow- ing inclusion and exclusion ...

6

Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft

Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft

... a stent-graft on aneurysm wall ...the stent-graft on the wall mechanics ...the stent-graft can reduce peak aneurysm wall stress 20 ...

12

Thermo-mechanical behavior of shape memory alloy made stent- graft by multi-plane model

Thermo-mechanical behavior of shape memory alloy made stent- graft by multi-plane model

... of stent-graft deformation limits is one of the key elements in the EVAR‟s ...that stent-grafts should include, there is no document that approaches the properties of the materials ...of stent ...

16

Endoluminal stent-graft placement in patients with acute aortic dissection type B q

Endoluminal stent-graft placement in patients with acute aortic dissection type B q

... addition, stent-graft placement over the intimal tear can prevent the development of an aneurysm by facilitating complete thrombosis of the false ...after stent-grafting and partial thrombosis in the ...

6

Total arch repair for acute type A aortic dissection with open placement of a modified triple-branched stent graft and the arch open technique

Total arch repair for acute type A aortic dissection with open placement of a modified triple-branched stent graft and the arch open technique

... triple-branched stent graft placement technique, the stent graft was inserted into the proximal descending aorta, arch and 3 arch vessels through the distal ascending transverse ...the ...

9

Surgical repair and reconstruction of aortic arch in debakey type I aortic dissection: recent advances and single-center experience in the application of branched stent graft

Surgical repair and reconstruction of aortic arch in debakey type I aortic dissection: recent advances and single-center experience in the application of branched stent graft

... tube graft and a distal self-expandable nitinol stent graft ...The graft comprises of a self-expandable stent coated with polyes- ter vascular graft fabric and the four-branched ...

9

Influence of endoleak positions on the pressure shielding ability of stent-graft after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA)

Influence of endoleak positions on the pressure shielding ability of stent-graft after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA)

... Background: Abdominal aortic aneurysm (AAA) is a kind of dangerous aortic vascular disease, which is characterized by abdominal aorta partial enlargement. At present, endovascular aneurysm repair (EVAR) is one of the ...

9

Original Article Bilateral isolated internal iliac artery aneurysms treated by bifurcated stent-graft combined with the coil embolization: a case report

Original Article Bilateral isolated internal iliac artery aneurysms treated by bifurcated stent-graft combined with the coil embolization: a case report

... The natural history of IIIAAs, high risk of associ- ated rupture, and associated mortality provides evidence for an aggressive approach to the management of IIIAAs. This rationale is re- inforced by the operative ...

5

Case Report The role of endovascular stent graft in the successful management of esophageal foreign body with dangerous vascular complications

Case Report The role of endovascular stent graft in the successful management of esophageal foreign body with dangerous vascular complications

... endovascular stent graft is suitable, minimally invasive, and effec- tive intervention in restoring the integrity of the aorta for patients with this ...endovascular stent graft and had good ...

12

Early prediction of acute kidney injury biomarkers after endovascular stent graft repair of aortic aneurysm: a prospective observational study

Early prediction of acute kidney injury biomarkers after endovascular stent graft repair of aortic aneurysm: a prospective observational study

... Although stent grafting to repair aortic aneurysms is associated with AKI caused by surgical procedures or the use of contrast agents, early biomarkers for AKI have not been adequately examined in stent ...

7

Endovascular Y-stent Graft RepairofChronicContained Ruptured Abdominal AorticAneurysminHigh-SurgicalRisk Patient

Endovascular Y-stent Graft Repair of Chronic Contained Ruptured Abdominal Aortic Aneurysm in High-Surgical Risk Patient

... cook stent graft was implanted using 12mmx56mm stent graft which was extended from right limb of the aortic stent graft to right common iliac ...aortic stent graft ...

9

Stent graft placement and balloon dilation for pseudoaneurysm complicated by distal arterial stenosis of the hepatic artery after pancreaticoduodenectomy

Stent graft placement and balloon dilation for pseudoaneurysm complicated by distal arterial stenosis of the hepatic artery after pancreaticoduodenectomy

... CA, USA), 3.5 mm in diameter and 16 mm in length, were placed in the CHA through a guidewire. Subsequently, the proper and the left hepatic arteries were dilated using a balloon dilator of 4.5 mm. The balloon dilation of ...

5

PERSONALIZED ENDOVASCULAR STENT GRAFTS Re inventing the personalized stent graft and its production process; a finite element analysis

PERSONALIZED ENDOVASCULAR STENT GRAFTS Re inventing the personalized stent graft and its production process; a finite element analysis

... in stent grafts, stainless steel (SS) and cobalt-chromium (CoCr) versions are on the market as ...expandable stent grafts, and have no shape ...expandable stent grafts is their increased crush ...

81

Show all 1589 documents...

Related subjects