• No results found

Suture fixation

Single coracoclavicular suture fixation with Mersilene tape versus hook plate in the treatment of acute type V acromioclavicular dislocation: a retrospective analysis

Single coracoclavicular suture fixation with Mersilene tape versus hook plate in the treatment of acute type V acromioclavicular dislocation: a retrospective analysis

... In our study, we compared CC suture fixation with Mersilene tape and CC fixation with hook plate for the treatment of type V AC joint dislocation. The results in- dicated that both methods can ...

9

Case Report Arthroscopic treatment of tibial spine fracture in adult with a simple modified suture fixation technique

Case Report Arthroscopic treatment of tibial spine fracture in adult with a simple modified suture fixation technique

... (ligament suture methods), and the other is based on the avulsed bone fragment (avulsed bone fragment suture methods) [25, ...Ligament suture methods require special instruments which are very ...

8

Comparison of single coracoclavicular suture fixation and hook plate for the treatment of acute unstable distal clavicle fractures

Comparison of single coracoclavicular suture fixation and hook plate for the treatment of acute unstable distal clavicle fractures

... (2) fixation by single CC suture fixation with Mersilene tape or clavicular hook plating; (3) normal shoulder function before injury; (4) without associated injuries; (5) regular follow-up more than ...

6

Suture fixation of tracheal stents for the treatment of upper trachea stenosis: a retrospective study

Suture fixation of tracheal stents for the treatment of upper trachea stenosis: a retrospective study

... The suture in the neck would produce certain ten- sion with patients’ swallowing and ...the suture would have a long retention in the ...the fixation site in this ...the suture part, it didn’t ...

6

One strategy for arthroscopic suture fixation of tibial intercondylar eminence fractures using the Meniscal Viper Repair System

One strategy for arthroscopic suture fixation of tibial intercondylar eminence fractures using the Meniscal Viper Repair System

... arthroscopic suture fixation that we ...arthroscopic suture of the ...polyethylene(UHMWPE) suture can be passed through the anterior cruciate ligament (ACL) and the loops for suture ...

5

Observational study of intraocular lens tilt in sutureless intrascleral fixation versus standard transscleral suture fixation determined by ultrasound biomicroscopy

Observational study of intraocular lens tilt in sutureless intrascleral fixation versus standard transscleral suture fixation determined by ultrasound biomicroscopy

... In the current study, no significant differences were seen between the two groups when we compared the vertical and horizontal IOL tilt. Additionally, postopera- tive best corrected visual acuity and postoperative ...

7

Modified Open Door Laminoplasty Using a Ceramic Spacer and Suture Fixation for Cervical Myelopathy

Modified Open Door Laminoplasty Using a Ceramic Spacer and Suture Fixation for Cervical Myelopathy

... the suture anchor system made it unnecessary to create a hole in the lateral mass and enabled reliable and faster fixation of the HA spacers in open-door ...

5

Outcomes and second look arthroscopic evaluation after combined arthroscopic treatment of tibial plateau and tibial eminence avulsion fractures: a 5 year minimal follow up

Outcomes and second look arthroscopic evaluation after combined arthroscopic treatment of tibial plateau and tibial eminence avulsion fractures: a 5 year minimal follow up

... ture fixation using four ...stable fixation and ad- equate stability of the knee joint for promoting minimal surgical morbidity, and satisfactory radiographic and clinical outcomes after a minimum follow-up ...

11

Lateral crural overlay of the lower lateral cartilages, a technique to enhance nasal tip rotation, and reduce projection in the droopy nasal tip

Lateral crural overlay of the lower lateral cartilages, a technique to enhance nasal tip rotation, and reduce projection in the droopy nasal tip

... done in the junction of the lateral third with the medial two thirds of the overdeveloped lateral crus, comparable to Hossam. 1 The cartilage incision is performed as a straight -line cephalocaudally, but care exercised ...

8

Technical Points Regarding New Enterostomy Formation for Incarcerated Stomal Prolapse in Loop Enterostomy

Technical Points Regarding New Enterostomy Formation for Incarcerated Stomal Prolapse in Loop Enterostomy

... For reconstruction of the stoma, a transverse abdomi- nal incision near the medial angle of the stoma was pla- ced in the previous wound. There was little abdominal ascites, and the suture fixation to each ...

5

Short Term Outcome of “Double Crown” Tackers Mesh Fixation in Laparoscopic Ventral Hernia Repair

Short Term Outcome of “Double Crown” Tackers Mesh Fixation in Laparoscopic Ventral Hernia Repair

... mesh fixation by stitches is still a matter of ...that suture fixation is mandatory in LVHR to reduce ...mesh fixation significantly re- duces operative time, overall complications rate with a ...

10

Single versus double row suture anchor fixation for greater tuberosity fractures – a biomechanical study

Single versus double row suture anchor fixation for greater tuberosity fractures – a biomechanical study

... waives suture knots. One of the benefits of suture fixation is that it de- pends on the strength of the rotator cuff tendons them- selves and not only on the bone ...

7

In-and-out technique for intraocular lens scleral fixation

In-and-out technique for intraocular lens scleral fixation

... the suture on the haptic, which increases the difficulty for IOL ...of fixation point at each end of the haptic. To decide the point of fixation to the sclera while maintaining good centering of the ...

6

Arthroscopic Fixation of Tibial Spine Avulsion in Skeletally Immature: The Technique

Arthroscopic Fixation of Tibial Spine Avulsion in Skeletally Immature: The Technique

... 10, 11, 12]. Seon et al. [13] found no significant difference in clinical outcome after screw or suture fixation. Bong et al. [14] reported fiber wire fixation to be superior to cannulated cancellous ...

5

Advantages of intraoral and transconjunctival approaches for posterior displacement of a fractured zygomaticomaxillary complex

Advantages of intraoral and transconjunctival approaches for posterior displacement of a fractured zygomaticomaxillary complex

... Background: Fracture of the zygomaticomaxillary complex (ZMC) is one of the most common facial injuries. A previous study has performed 3D analyses of the parallel and rotational displacements that occur in a fractured ...

6

The Elist Drain Retainer: A New Adherent Drain Retainer with Antibacterial Properties

The Elist Drain Retainer: A New Adherent Drain Retainer with Antibacterial Properties

... The brief task of inserting a tube, such as a central venous catheter or a chest tube, is usually followed by the longer task of ensuring that the tube will not be inadvertently pulled out. Various methods of securing ...

8

Management of posterior capsular tear with scleral fixation lenses

Management of posterior capsular tear with scleral fixation lenses

... A prospective study of 30 cases was done from May 2008 to December 2009 with patients undergoing Scleral fixation IOL. Out of these 10 were males and 20 females accounting for 33% and 67% respectively. Mean age ...

86

Biomechanical Investigation of Locked Plate Fixation with Suture Augmentation in a Comminuted Three Part Proximal Humerus Fracture Model

Biomechanical Investigation of Locked Plate Fixation with Suture Augmentation in a Comminuted Three Part Proximal Humerus Fracture Model

... the suture-augmented ...that suture augmentation may work clinically to confer added stability to the greater tuberosity during proxim- al humerus fracture ...

12

Primary single suture anchor re-fixation of anterior cruciate ligament proximal avulsion tears leads to good functional mid-term results: a preliminary study in 12 patients

Primary single suture anchor re-fixation of anterior cruciate ligament proximal avulsion tears leads to good functional mid-term results: a preliminary study in 12 patients

... primary suture anchor repair of the ACL and suture of the patellar tendon competes with a single repair of the patellar tendon and ACL re- construction in a second ...

7

Different suture anchor fixation techniques affect contact properties in humeral greater tuberosity fracture: a biomechanical study

Different suture anchor fixation techniques affect contact properties in humeral greater tuberosity fracture: a biomechanical study

... the fixation stability and in particular by the increased interfragmentary shear movements [16, ...Improving fixation stability is crucial to optimal fracture ...double-row fixation techniques, both ...

10

Show all 2477 documents...

Related subjects