• No results found

transformer oil/paper insulation

Hot Spot Temperature and Grey Target Theory Based Dynamic Modelling for Reliability Assessment of Transformer Oil-Paper Insulation Systems: A Practical Case Study

Hot Spot Temperature and Grey Target Theory Based Dynamic Modelling for Reliability Assessment of Transformer Oil-Paper Insulation Systems: A Practical Case Study

... This paper develops a novel dynamic correction method for the reliability assessment of large oil-immersed power ...the transformer oil-paper insulation system (TOPIS) as the ...

22

Aging of Kraft paper insulation in natural ester dielectric fluid

Aging of Kraft paper insulation in natural ester dielectric fluid

... the oil and paper shares the applied electrical stress [2] and prevents partial discharge in the ...upgraded paper in natural ester possesses slower ageing rate compared with when immersed in mineral ...

5

Copper Release Kinetics and Ageing of  Insulation Paper in Oil Immersed  Transformers

Copper Release Kinetics and Ageing of Insulation Paper in Oil Immersed Transformers

... of transformer oil is one the most common product quality ...in oil compromises the insulating capacity of the oil/paper system, as can be demonstrated by a substantial drop in the ...

16

Investigation of increasing fault gas in excitation transformers

Investigation of increasing fault gas in excitation transformers

... Since the average number of glucose molecules in each cellulose cluster is determined by the degree of polymerization (DP), therefore the value of DP also can be an indicator for the mechanical stability of Kraft ...

37

Study of Grain Boundary Characters under Intergranular Corrosion in Copper Conductor and Its Relationship with Paper Oil Insulation in Transformer

Study of Grain Boundary Characters under Intergranular Corrosion in Copper Conductor and Its Relationship with Paper Oil Insulation in Transformer

... in transformer oil is reported in ...takes paper oil insulation system as the research object, using Electron Backscatter Diffraction (EBSD) study the grain boundaries of copper ...

15

Power Transformer Insulation Assessment Based on Oil-Paper Measurement Data Using SVM-Classifier

Power Transformer Insulation Assessment Based on Oil-Paper Measurement Data Using SVM-Classifier

... Abstract: Oil immersed paper insulation condition is a crucial aspect of power transformer’s life condition ...power transformer. This article presents classification analysis of ...

14

Residual Life assessment with DGA, Furan content in transformer oil and Degree of polymerization of solid insulation

Residual Life assessment with DGA, Furan content in transformer oil and Degree of polymerization of solid insulation

... consumers. Oil filled transformers in service for more than 15 years, it is highly recommended to assess the remnant ...the transformer. This paper presents the real life case study of assessing the ...

5

Weighting Characteristic For Kraft Paper Immersed In Mineral And Vegetable Insulation Oil

Weighting Characteristic For Kraft Paper Immersed In Mineral And Vegetable Insulation Oil

... Kraft Paper has a high dielectric constant value which means that they are a good ...Kraft Paper has high ability to store electrical energy in an electric ...Kraft Paper is considered as a good ...

24

THE FILTRATION PROCESS OF POWER TRANSFORMER

THE FILTRATION PROCESS OF POWER TRANSFORMER

... this oil also serves two other purposes: helps to maintain the transformer core and coils which are fully immersed within the oil and prevents direct contact with atmospheric oxygen cellulose ...

12

Dissolved Gas Analysis (DGA) of Mineral Oil
Used in Transformer

Dissolved Gas Analysis (DGA) of Mineral Oil Used in Transformer

...  Localized overheating or hot spots and general overheating due to inadequate cooling or sustained overloading Each of the faults results in thermal degradation of the oil either alone or in combination with ...

5

Estimation of Current Transformer Insulation Life with an Effect of Environmental Variables

Estimation of Current Transformer Insulation Life with an Effect of Environmental Variables

... Current transformer is an important component of EHV substation & the power ...to insulation failure. Insulation aging is a function of temperature and other environmental factors such as solar ...

9

Development of a novel asset management system for power transformers based on Ontology

Development of a novel asset management system for power transformers based on Ontology

... A transformer winding is always covered with paper, and located in ...The insulation problem may happen, when trace water occurs whether in the oil or ...

6

Insulation Resistance Test and Oil Test of Distribution Transformer

Insulation Resistance Test and Oil Test of Distribution Transformer

... ABSTRACT: Transformer is one of the most important part of distribution and transmission process of ...A transformer has to go through different testing procedures in manufacturer’s premises to prove that ...

6

132kV Oil Impregnated Paper Bushing Transformer   Design by CAD, Analysed by FEM

132kV Oil Impregnated Paper Bushing Transformer Design by CAD, Analysed by FEM

... Bushing transformer is one of the fundamental components of high voltage power ...main insulation in bushing transformer [4]; polymer, resin impregnated paper (RIP) and oil impregnated ...

8

Analysis Of Transformer Insulation Parameters Using Polarization And Depolarization Current Method And Frequency Domain Spectroscopy

Analysis Of Transformer Insulation Parameters Using Polarization And Depolarization Current Method And Frequency Domain Spectroscopy

... of transformer is 60 years if it undergoes thorough maintenance ...a transformer is crucial for stability and reliability of power ...of transformer is dependent on the state of the insulation ...

5

Prediction of Transformer Insulation Life with an Effect of Environmental Variables

Prediction of Transformer Insulation Life with an Effect of Environmental Variables

... top oil temperature (TOT) over the ambient temperature, and the rise in the winding HST over the top oil ...this paper a new semi-physical model comprising of the environmental variables for the ...

6

A Probabilistic Modeling of Distribution Equipment Deterioration; An application to Transformer Insulation.

A Probabilistic Modeling of Distribution Equipment Deterioration; An application to Transformer Insulation.

... The model takes data from various inspection and maintenance tasks and the frequency of performing the tasks as inputs and gives the failure rates as output. The changes in the “mean time to failure” indicator can be ...

7

Asset management decision making of power transformer with insulation agieng knowledge

Asset management decision making of power transformer with insulation agieng knowledge

... This paper proposes a smart asset management tool which can be used to prioritize the monitoring and maintenance activities of transformers and to predict a transformer condition ...this paper. ...

37

The Effect Of High Voltage Stress On Different Type Of Oil

The Effect Of High Voltage Stress On Different Type Of Oil

... engine oil. The main reason of the study was to replace the transformer oil in the ...The transformer needs oil for the insulation of its ...The oil must have high ...

24

IOT BASED ONLINE MONITORING OF TRANSFORMER MAINTENANCE SYSTEM

IOT BASED ONLINE MONITORING OF TRANSFORMER MAINTENANCE SYSTEM

... The materials which allow just an insignificant current (request of PA) to stream in stage with the connected voltage. Protecting materials or protects are to a great degree differing in root and properties. They are ...

8

Show all 10000 documents...