• No results found

vibration response

Vibration response of USFB composite floors

Vibration response of USFB composite floors

... Abstract: This paper is focused on the vibration response of a composite flooring system that incorporates perforated steel Ultra Shallow Floor Beams, called USFB. This is a lightweight system that can ...

11

Free Vibration Response of Laminated Composite Plate Shear Walls

Free Vibration Response of Laminated Composite Plate Shear Walls

... free vibration response of laminated composite plate shear walls and compared it with the performance of steel plate shear walls using the finite element system ...

11

Vibration response imaging: protocol for a systematic review

Vibration response imaging: protocol for a systematic review

... Background: The concept of lung sounds conveying information regarding lung physiology has been used extensively in clinical practice, particularly with physical auscultation using a stethoscope. Advances in computer ...

8

Influences of Glass and Carbon Powder Reinforcement on the Vibration Response and Characterization of an Isotropic Hyper Composite Materials Plate Structure

Influences of Glass and Carbon Powder Reinforcement on the Vibration Response and Characterization of an Isotropic Hyper Composite Materials Plate Structure

... and vibration response of isotropic hyper composite ...the response of composite plate with various powder parameters on the effect of composite plate ...and response of the plate are ...

12

Estimation of Vibration Response of Reciprocating Engine Crankshaft

Estimation of Vibration Response of Reciprocating Engine Crankshaft

... of vibration produced inside the engine on crankshaft and its effect on performance of ...out vibration response of reciprocating engine crankshaft is by making graphical investigation of various ...

7

Vibration Response of a Gearbox having Gear with Teeth Root Cracks

Vibration Response of a Gearbox having Gear with Teeth Root Cracks

... of vibration in the ...the vibration characteristics of the gearbox, which has cracked gear as the ...defect. Vibration signals are acquired using accelerometer placed on the bearing housing nearer ...

6

Identification of rotor bearing parameters using vibration response data in a turbocharger rotor

Identification of rotor bearing parameters using vibration response data in a turbocharger rotor

... The various signal processing methods such as FFT, Hilbert Transform (HT),Wavelet Transform (WT) and Short Time Fourier Transform (STFT) have been utilized to analyze vibration signals to diagnose the condition of ...

12

Study and Vibration Response Analysis of MR Cantilever Beam

Study and Vibration Response Analysis of MR Cantilever Beam

... One of the main issues in various structures is the undesirable excessive vibration. The control of structural vibrations can be implemented different ways such as modifying stiffness, mass, damping and shape by ...

6

A method of characterisation of the nonlinear vibration transmissibility of cushioning materials

A method of characterisation of the nonlinear vibration transmissibility of cushioning materials

... the vibration response of various cushioning materials and so a vibration source or shaker is ...material’s vibration transmissibility is to be studied, so an experimental rig is needed to ...

147

Dynamic analysis of an office building due to vibration from road construction activities

Dynamic analysis of an office building due to vibration from road construction activities

... construction-induced vibration may be harmful directly and indirectly towards the neighbouring ...building vibration response of concrete masonry load bearing system and its vibrational performance ...

8

Static and Dynamic Characteristics Analysis of Three Coordinates manipulator based on Workbench Pin Hong 1, Ying Pan2 , Ting Zhang 3

Static and Dynamic Characteristics Analysis of Three Coordinates manipulator based on Workbench Pin Hong 1, Ying Pan2 , Ting Zhang 3

... random vibration analysis of the mechanism wad carried out on the basis of modal analysis, which got the acceleration response in the direction of x、y、z and the equivalent stress cloud diagram of the ...the ...

8

Damage detections in nonlinear vibrating thermally loaded plates

Damage detections in nonlinear vibrating thermally loaded plates

... in vibration- based monitoring have been emerging ...structural vibration response, or, often concomitantly, non-linear systems the- ...structural vibration response, which can indicate ...

21

The Response and Optimisation of Hybrid Wind Turbine Towers

The Response and Optimisation of Hybrid Wind Turbine Towers

... free vibration response and MDOF dynamical models were used to investigate forced vi- bration response of towers of varying ...free vibration response but also through frequency domain ...

326

Using a qualitative approach to explore the human response
to vibration in residential environments in the United
Kingdom

Using a qualitative approach to explore the human response to vibration in residential environments in the United Kingdom

... to vibration in their homes is valuable, particularly in terms of developing standards which can be used for planning purposes in order to understand vibration levels and their impact on residential ...of ...

12

Measurement of ground to building frequency response
functions for assessment of human exposure to vibration
from railway vibration

Measurement of ground to building frequency response functions for assessment of human exposure to vibration from railway vibration

... of vibration may be affected by reflection at the front of the foundation (with respect to the travelling wave) and decreased at the rear side by dissipation and front side reflection ...

16

Finite Element Dynamics of Human Ear System Comprising Middle Ear and Cochlea in Inner Ear

Finite Element Dynamics of Human Ear System Comprising Middle Ear and Cochlea in Inner Ear

... the vibration of the stapes by pulling on the head of the stapes, to prevent excess motion of the stapes, and to control the amplitude of waves in order to protect the inner ear from the loud ...

14

Human response to vibration in residential environments (NANR209), technical report 3 : calculation of vibration exposure

Human response to vibration in residential environments (NANR209), technical report 3 : calculation of vibration exposure

... Figure 14 shows results obtained from the external array at Site A. The z component of Peak Particle Acceleration (PPA) is plotted against distance for times when piling was taking place at different pile positions (see ...

73

Human response to vibration in residential environments (NANR209), technical report 2: measurement of response

Human response to vibration in residential environments (NANR209), technical report 2: measurement of response

... of vibration; to be implemented at sites specifically identified for vibration from the source under ...noticing vibration and noise from the source were successfully identified and routed to further ...

40

Isolated Nucleus Stiffens in Response to Low Intensity Vibration

Isolated Nucleus Stiffens in Response to Low Intensity Vibration

... Mechanical forces influence stem cell dynamics, decisions, and lineage selections. Nuclear response to specific applied loads (magnitude, frequency, time interval) and mechanisms responsible are not well ...

78

Simulation and Experimental Study of Vibration and Noise of Pure Electric Bus Transmission based on Finite Element and Boundary Element Methods

Simulation and Experimental Study of Vibration and Noise of Pure Electric Bus Transmission based on Finite Element and Boundary Element Methods

... of vibration and noise of the transmission becomes ...the vibration and noise problems of transmission can be avoided during the design process, which will shorten the development cycle and reduce the ...

8

Show all 10000 documents...