• No results found

volar plate

Volar Plate Fixation for the Treatment of Distal Radius Fractures: Analysis of Adverse Events

Volar Plate Fixation for the Treatment of Distal Radius Fractures: Analysis of Adverse Events

... the volar plating procedures performed for distal radius fractures from January 2000 to January 2010 in a single trauma ...with volar plate fixation of a distal radius fracture with a minimum 1 year ...

6

Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model

Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model

... Specimens were thawed at room temperature on the day of testing. Skin and soft tissues were removed, and the wrist capsule and interosseous membrane, triangular disc, and the capsule of the distal radioulnar joint were ...

8

Ultrasonography or direct radiography? A comparison of two techniques to detect dorsal screw penetration after volar plate fixation

Ultrasonography or direct radiography? A comparison of two techniques to detect dorsal screw penetration after volar plate fixation

... Some studies have reported that USG exhibits 100% sen- sitivity and specificity in identifying dorsal cortex screw penetration [11]. In a cadaveric study, Watchmaker et al. found that dissection and USG is highly ...

7

Finite Element Analysis Study of Prototype of a Novel Intramedullary Injectable Bioresorbable Polymer Fixator versus a Volar Plate for Surgical Treatment of Distal Radius Fractures

Finite Element Analysis Study of Prototype of a Novel Intramedullary Injectable Bioresorbable Polymer Fixator versus a Volar Plate for Surgical Treatment of Distal Radius Fractures

... the volar rim, as close to but not exceeding the watershed ...the plate to represent the physical contact limita- tions of an actual bone plate and the different patient ...the plate and three ...

20

Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol

Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol

... AO: Arbeitsgemeinschaft für osteosynthesefragen foundation; ASIF: Association for the study of internal fixation; REC: Research ethics committee; DASH: Disabilities of arm, shoulder and hand; EPM: Paulista school of ...

7

Using self drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study

Using self drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study

... in volar locking plate ...in volar plate osteosynthesis for the distal radius at least for extraarticular fractures saving not only oper- ation time, but also eliminating the causes of ...

7

A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: analysis of 40 cases

A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: analysis of 40 cases

... compression plate, distal radius volar plate, proximal humeral plate, and tibial nail to commercially available devices regarding the biomechanical characteristics (by four-point bending, ...

7

Distal radius fractures with diaphyseal involvement: fixation with fixed angle volar plate

Distal radius fractures with diaphyseal involvement: fixation with fixed angle volar plate

... Volar plate fixation has been recognized to be an effective and safe treatment in unstable distal radius fractures [1, ...Long volar plates are available in most surgical instrumen- tation boxes to ...

7

The influence of distal screw length on the primary stability of volar plate osteosynthesis—a biomechanical study

The influence of distal screw length on the primary stability of volar plate osteosynthesis—a biomechanical study

... The general preparation has been outlined in detail previ- ously [13]. In brief, the radii were cleaned of all soft tissue and multidirectional, angular stable volar plates (APTUS 2.5 ADAPTIVE TriLock Distal ...

8

Incidence of complications and secondary procedure following distal radius fractures treated by volar locking plate (VLP)

Incidence of complications and secondary procedure following distal radius fractures treated by volar locking plate (VLP)

... a volar and ulnar direction [22]. A standard volar plate fixation is insufficient to provide equal fixation and stabilization to both the scaphoid and the lunate ...the volar lunate fragment ...

9

Cost effectiveness of treatment with percutaneous Kirschner wires versus volar locking plate for adult patients with a dorsally displaced fracture of the distal radius: Analysis from the DRAFFT trial

Cost effectiveness of treatment with percutaneous Kirschner wires versus volar locking plate for adult patients with a dorsally displaced fracture of the distal radius: Analysis from the DRAFFT trial

... cost of surgical fixation versus non-surgical treatment (Shauver et al., 2011a, Shauver et al., 2011b, Papaloizos et al., 2004, Schonnemann et al., 2011, Davis et al., 2006, Vinnars et al., 2007, Arora et al., 2007), ...

23

Failure of volar locking plate fixation of an extraarticular distal radius fracture: A case report

Failure of volar locking plate fixation of an extraarticular distal radius fracture: A case report

... Another factor that may have strengthened the fixa- tion is the number and the diameter of screws used to fix the fracture. We only used 4 distal locking screws. The plate however was designed to accommodate up to ...

6

UK DRAFFT : a randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius

UK DRAFFT : a randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius

... management remains controversial. In general, fractures of the distal radius are treated non-operatively if the bone fragments can be held in anatomical alignment by a plaster cast or orthotic. However, if this is not ...

7

Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes

Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes

... the volar plate distal near to the watershed line in order to capture the articular fragments; however, this could result in late flexor tendon rupture ...locking plate can be placed proximal to the ...

8

Original Article Results of type C fractures of distal radius treated by volar locking plate (VLP), an observational comparative study

Original Article Results of type C fractures of distal radius treated by volar locking plate (VLP), an observational comparative study

... or volar plate, Rein et al reported the better flexion in VLP group but better extension and radial deviation in dorsal plate group, provid- ing us with an alternative for treating fractures with ...

9

Locked volar plating for complex distal radius fractures: Patient reported outcomes and satisfaction

Locked volar plating for complex distal radius fractures: Patient reported outcomes and satisfaction

... None of our patients suffered any extensor tendon or flexor pollicis longus rupture although we have pre- viously noted these complications among other patients. Both of these complications are well described [24,25] and ...

6

A prospective study on short term analysis of clinical, radiological and functional outcome of surgical management of Type B & Type C distal radius fracture with volar locking plate

A prospective study on short term analysis of clinical, radiological and functional outcome of surgical management of Type B & Type C distal radius fracture with volar locking plate

... Bone grafting was not done in any of the cases in spite of the higher degree of comminution ,because the fragments are well buttressed with volar plate. The reduction of the distal radius and its articular ...

125

UK DRAFFT   A randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius

UK DRAFFT A randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius

... management remains controversial. In general, fractures of the distal radius are treated non-operatively if the bone fragments can be held in anatomical alignment by a plaster cast or orthotic. However, if this is not ...

6

A new method to predict the outcome of the volar locked plate treatment for distal radius fracture

A new method to predict the outcome of the volar locked plate treatment for distal radius fracture

... However, we failed to discover any relationship be- tween the ratio and the other outcomes (pronation, su- pination, radial deviation, ulnar deviation, grip strength, DASH scores). We supposed that changes of the ratio ...

6

Management of Intra Articular Fractures of Distal Radius with Volar Locking Compression Plate – Midterm Outcome Analysis

Management of Intra Articular Fractures of Distal Radius with Volar Locking Compression Plate – Midterm Outcome Analysis

... Conclusion: Volar locking compression plate is the implant of choice in Comminuted Intraarticular distal radius ...locked volar plate predictably yields better patient reported outcome as per ...

7

Show all 2658 documents...

Related subjects