[PDF] Top 20 Endovascular Treatment of Middle Cerebral Artery Aneurysms with Flow Modification with the Use of the Pipeline Embolization Device
Has 10000 "Endovascular Treatment of Middle Cerebral Artery Aneurysms with Flow Modification with the Use of the Pipeline Embolization Device" found on our website. Below are the top 20 most common "Endovascular Treatment of Middle Cerebral Artery Aneurysms with Flow Modification with the Use of the Pipeline Embolization Device".
Endovascular Treatment of Middle Cerebral Artery Aneurysms with Flow Modification with the Use of the Pipeline Embolization Device
... 21 aneurysms (84%; ...of aneurysms bearing a bifurcating branch by using the PED: 1) moderate to significant decrease in the aneurysm filling (1–3 months), 2) the infundibulum-like appearance resulting from ... See full document
7
Treatment of Middle Cerebral Artery Aneurysms with Flow Diverter Stents: A Systematic Review and Meta Analysis
... “middle cerebral artery,” “flow-diverter,” “flow diversion,” “anterior circulation,” “aneurysms,” “pipeline,” and “endovascular” were used in both “AND” and “OR” ... See full document
6
Endovascular Treatment of Middle Cerebral Artery Aneurysms as First Option: A Single Center Experience of 92 Aneurysms
... Treatment was performed within 3 days of SAH. General anesthesia was administered to all of the patients, and a femoral approach with a 6F sheath was used in all of the cases. The approach was bifemoral when the ... See full document
6
Endovascular Treatment of Wide Neck Middle Cerebral Artery Aneurysms with Stents: A Review of 16 Cases
... 3 aneurysms were first catheterized before stent ...to use the mesh technique in 1 aneu- ...coil embolization, we found that it was difficult to preserve the other MCA ...parent artery were ... See full document
7
The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial
... 16 aneurysms (51.6%), and 15 aneurysms were treated with PED reconstruction ...(97.9% device-placement ...diminished flow in the parent ICA following deployment of the PED and coiling of the ... See full document
7
Complications, imaging results, and midterm clinical outcomes of pipeline embolisation device in the treatment of cerebral aneurysms
... The use of balloons such as the Hyperglide or Hyper- form (ev3, Irvine) to assist the PED in opening com- pletely and apposing the endothelial surface has become commonplace, and is described by many authors ... See full document
10
Safety of the Pipeline Embolization Device in Treatment of Posterior Circulation Aneurysms
... the treatment of posterior circulation aneurysms that are otherwise difficult or impossible to treat with standard endovascular or surgical ...with use of the PED in the basilar artery ... See full document
7
Pipeline Diameter Significantly Impacts the Long Term Fate of Jailed Side Branches during Treatment of Intracranial Aneurysms
... the treatment of wide-neck intracranial artery aneurysms, Sponsor: MicroVention; ULTRA: Ultra Coils from Start to Finish for the Endovascular Repair of Small Intracranial Aneurysms, ... See full document
8
A Novel Flow Diverting Device (Tubridge) for the Treatment of 28 Large or Giant Intracranial Aneurysms: A Single Center Experience
... the use of a nickel-titanium alloy (commonly known as nitinol, which exhibits shape-memory and superelastic- ity) and flared ends, the Tubridge offers multiple structural improvements over the Pipeline ... See full document
8
Endovascular Treatment of 300 Consecutive Middle Cerebral Artery Aneurysms: Clinical and Radiologic Outcomes
... coil embolization (1 case primary treatment, 1 case re-treatment) were used for the treatment of wide-neck ...unruptured aneurysms, administered after initial coil deployment when a ... See full document
9
pCONus Device for the Endovascular Treatment of Wide Neck Middle Cerebral Artery Aneurysms
... p64 Flow Modulation Device; Payment for Lectures (including service on Speakers Bureaus): phenox (products: pCONus and flow-diverter p64 Flow Modulation De- vice), Comments: German Society Meeting in ... See full document
6
Immediate and Midterm Results following Treatment of Unruptured Intracranial Aneurysms with the Pipeline Embolization Device
... 2010. Aneurysms with a wide neck ( ⬎ 4 mm), unfavorable dome/neck ratio ( ⬍ ...for use of the PED on compassionate grounds was sought from both hospital adminis- tration and the Therapeutic Goods and ... See full document
7
Treatment of Tandem Internal Carotid Artery Aneurysms Using a Single Pipeline Embolization Device: Evaluation of Safety and Efficacy
... single aneurysms treated by the PED in the literature, to our knowledge, and there were attempts to control for significant differences between comparison groups during analysis of ... See full document
5
Flow Diverter Stents for the Treatment of Saccular Middle Cerebral Artery Bifurcation Aneurysms
... to flow impairment inside the covered ...collateral flow was always tested with balloon MCA occlusion before FDS treatment, though exist- ing, collateral flow was sometimes ...collateral ... See full document
6
Original Article Pial arteriovenous fistulas: two pediatric cases and a literature review
... present treatment challenges for both endovascular and open cerebrovascular ...and/or embolization with balloon-assisted liquid emboli to ensure fistula ...blood flow resulted in a sustained ... See full document
8
Endovascular Treatment of Middle Cerebral Artery Aneurysms for 120 Nonselected Patients: A Prospective Cohort Study
... initial treatment in 7 cases and ⬎ 6 months after treatment in 3 ...retreated aneurysms was ⱕ 10 FIG ...carotid artery shows a 7-mm aneurysm with a 4-mm-wide neck in the MCA ...carotid ... See full document
6
Aneurysms of the Posterior Cerebral Artery: Classification and Endovascular Treatment
... these aneurysms could be the mere stretching of the PCA against the fixed and rather rigid edge of the ...such aneurysms, which has not been widely re- ported, specifically with regard to the appropriate- ... See full document
8
Risk Factors for Hemorrhagic Complications following Pipeline Embolization Device Treatment of Intracranial Aneurysms: Results from the International Retrospective Study of the Pipeline Embolization Device
... coil patients suggests an innate increase in the incidence with PEDs. One may speculate that the increased metal sur- face area to which the platelets are ex- posed may result in activation through increased shear, ... See full document
6
Treatment of middle cerebral artery (MCA) aneurysms: a review of the literature
... intracranial aneurysms have changed dramatically over the past decades. Endovascular treatment has been increasingly adopted as the primary procedure for a wide spectrum of aneurysms ...pursue ... See full document
7
Initial Experience with the Use of Intravenous Eptifibatide Bolus during Endovascular Treatment of Intracranial Aneurysms
... During the 38-month period reviewed, of the 84 procedures performed with eptifibatide, 2 patients (2.4%) had an intra- procedural aneurysm rupture. In both of these patients, an EVD was inserted preprocedure. In the 77 ... See full document
5
Related subjects