[PDF] Top 20 iStent trabecular micro-bypass stent for open-angle glaucoma
Has 10000 "iStent trabecular micro-bypass stent for open-angle glaucoma" found on our website. Below are the top 20 most common "iStent trabecular micro-bypass stent for open-angle glaucoma".
iStent trabecular micro-bypass stent for open-angle glaucoma
... of iStent implantation that can optimize the success of the procedure are important to ...the trabecular meshwork followed by a flattened approach to slide into Schlemm’s canal without abutting against the ... See full document
9
<p>Three-year outcomes of combined trabecular micro-bypass and phacoemulsification in a predominantly Hispanic population with primary open-angle glaucoma</p>
... one iStent Trabecular Micro-Bypass ...normal angle anatomy, and a need for IOP and/or medication ...chamber angle, ocular in fl ammation, or corneal opacities compromising ... See full document
11
Long-term titrated IOP control with one, two, or three trabecular micro-bypass stents in open-angle glaucoma subjects on topical hypotensive medication: 42-month outcomes
... three iStent trabecular micro-bypass stents in a sole ...titanium stent has a length of ...the stent, which is pre-loaded on a single-use inserter that is advanced ab internally ... See full document
8
<p>Comparison Of Surgical Outcomes Between Excisional Goniotomy Using The Kahook Dual Blade And iStent Trabecular Micro-Bypass Stent In Combination With Phacoemulsification</p>
... coexisting open-angle glaucoma (OAG) and visually signi fi cant cat- aract who underwent phacoemulsi fi cation cataract extrac- tion with placement of an intraocular lens combined with either ... See full document
6
<p>Ab interno canaloplasty combined with trabecular bypass stenting in eyes with primary open-angle glaucoma</p>
... An intracanalicular scaffold (Hydrus, Ivantis, Inc.) has a somewhat similar mechanism of action combining some of the bene fi ts of canaloplasty, ie dilation of the canal and aqueous access to more collector channels ... See full document
10
<p>Refractive outcomes after trabecular microbypass stent with cataract extraction in open-angle glaucoma</p>
... XLStat version 2018.6 was used for statistical analyses. SE refractive outcome was calculated as the difference between the postoperative SE and target SE and divided into the percentage within 0.25 D, 0.50 D, and 1.00 D ... See full document
10
Clinical evaluation of a trabecular microbypass stent with phacoemulsification in patients with open-angle glaucoma and cataract
... a bypass through the trabecular meshwork to improve physiological aqueous outflow and lower ...L-shaped trabecular microbypass stent is ...The iStent, in conjunction with cataract ... See full document
7
Efficacy of two trabecular micro-bypass stents combined with topical travoprost in open-angle glaucoma not controlled on two preoperative medications: 3-year follow-up
... Nevertheless, 3-year data from this study provide a valuable measurement of the IOP- and medication-lowering effects of 2 iStent devices implanted as a standalone proce- dure together with postoperative ... See full document
6
<p>One-year outcomes following implantation of second-generation trabecular micro-bypass stents in conjunction with cataract surgery for various types of glaucoma or ocular hypertension: multicenter, multi-surgeon study</p>
... Several limitations exist in this retrospective study. As is the case in most real-life clinical cohorts, it was not appropriate to complete medication washout due to the potential risks of IOP spikes in participating ... See full document
9
Prospective unmasked randomized evaluation of the iStent<em> inject</em><sup>®</sup> versus two ocular hypotensive agents in patients with primary open-angle glaucoma
... two iStent inject devices. Each iStent inject model GTS400 is a single-piece heparin-coated, gamma-sterilized titanium stent (Figure ...the trabecular meshwork, while multiple outlet lateral ... See full document
8
A prospective 3-year follow-up trial of implantation of two trabecular microbypass stents in open-angle glaucoma
... prospective, open-label study involved phakic or pseudophakic subjects with OAG (including primary, pig- mentary, and ...of glaucoma, willingness to attend follow-up visits for 5 years postoperatively, and ... See full document
9
Micro-invasive glaucoma surgery (MIGS): a review of surgical procedures using stents
... single iStent inject stent is currently the smallest medical implant approved for use in the human body during surgical ...The iStent inject stents are delivered in an injector system which injects ... See full document
18
Two-year data comparison of ab interno trabeculectomy and trabecular bypass stenting using Exact Matching
... to trabecular bypass stenting (TBS) with the iStent (Glaukos Corp, San Clemente, ...adult open-angle ...free trabecular meshwork (TM) ablation over up to 180 degrees by plasma ... See full document
23
Prospective, randomized study of one, two, or three trabecular bypass stents in open-angle glaucoma subjects on topical hypotensive medication
... Subjects were to be randomized in a 1:1:1: ratio (40 sub- jects per group) to either the one-stent, two-stent, or three- stent group. Randomization treatment assignments were generated using a ... See full document
8
<p>Four-Year Outcomes of Two Second-Generation Trabecular Micro-Bypass Stents in Patients with Open-Angle Glaucoma on One Medication</p>
... multiple trabecular micro-bypass stents (either iStent or iStent ...one iStent inser- tion, and reduced further to ...second iStent insertion (P< ...one iStent ... See full document
10
A review of the iStent<sup>®</sup> trabecular micro-bypass stent: safety and efficacy
... the iStent in relation to other MIGSs, including canaloplasty, trabectome, endocyclophotocoagula- tion, and ab interno gonioscopy-assisted transluminal trabecu- ...the iStent in order to determine where ... See full document
8
<p>Outcomes of Combined iStent Trabecular Micro-Bypass and Cataract Surgery for the Treatment of Open-Angle Glaucoma in a Saudi Population</p>
... IOP reduction which resulted from iStent implantation ran- ged from 10 – 43%. 21–23 When accounting for this wide range, the relationship between baseline IOP and post-operative IOP is noteworthy. It has been ... See full document
8
<p>Refractive Outcomes After Trabecular Micro-Bypass Stents (iStent <em>Inject</em>) with Cataract Extraction in Open-Angle Glaucoma</p>
... for glaucoma patients where medical and laser treat- ments have been unable to control intraocular pressure ...for glaucoma, and increasingly anterior segment ...invasive glaucoma surgery (MIGS) ... See full document
8
<p>iStent Trabecular Microbypass Stent Implantation with Phacoemulsification in Patients with Open-Angle Glaucoma: 6-Year Outcomes</p>
... single trabecular microbypass stent in combination with cataract surgery were included in this retrospective case ...mary open-angle ... See full document
8
<p>Combined iStent<sup>®</sup> <em>Inject</em> Trabecular Micro-Bypass and Phacoemulsification in Australian Patients with Open-Angle Glaucoma</p>
... Micro-invasive glaucoma surgery (MIGS) refers to an increasingly popular category of surgical procedures de fi ned by minimal tissue disruption, generally sustained ef fi cacy in lowering IOP, a high safety ... See full document
9
Related subjects