Configuration Data

In document Ericsson SOM Operator Guide (Page 83-99)

Fieldname Format Description Example

3.2.2 Configuration Management

3.2.2.3 Configuration Data

Configuration View menu

The items listed in the View menu are showed in the following figure.

Figure 14 View menu

3.2.2.3 Configuration Data

MINI-LINK Traffic Node Terminals Data

Table 1MINI-LINK TN Configuration data for Radio Terminal (MMU2 or SMU2 type)

Fieldname Format Description Example

Terminal ID Text string Radio Terminal Name 1/6+7+8

Can be:

Equipment Type Text string The type of equipment

MLTN_1+0, MLTN_1+1 Can be:

1+0, Protection Mode Text string The equipment protection mode

1+1Hot or , 1+1Work

Traffic Rate Text string Configured traffic 2x2, 16xDS1 etc

Far End ID Text string ID of the far end terminal 001B

Active Radio Text string Indicates the Active Radio Can be: 1, 2, B,

ServiceOn Microwave Element Manager - Operator Guide 2BElement Management User Interface

Fieldname Format Description Example

1 -> Ra1, 2 -> Ra2,

B -> both, Radio are transmitting (1+1 Work) Frequency Band Ra1 Text string RAU Frequency Band Ra1 15, 23 Frequency Index Ra1 Text string RAU Frequency sub-band Ra1 25, 58 Frequency Band Ra2 Text string RAU Frequency Band Ra2 15, 23 Frequency Index Ra2 Text string RAU Frequency sub-band Ra2 25, 58 Channel Spacing Text string Channel Spacing (MHz) 3.5, 7, 14 TX Frequency Ra1 Text string Transmitting Frequency Ra1 (MHz) 14950.00,

15006.00 TX Frequency Ra2 Text string Transmitting Frequency Ra2 (MHz) 14950.00, 15006.00 RX Frequency Ra1 Text string Receiving Frequency Ra1 (MHz) 14530.00,

14586.00 RX Frequency Ra2 Text string Receiving Frequency Ra2 (MHz) 14530.00,

14586.00 TX Attenuator Ra1 Text string Tx Attenuator value for Ra1 (dB)

TX Attenuator Ra2 Text string Tx Attenuator value for Ra2 (dB)

Can be also OFF,

Output Power Ra1 Text string Current output power Ra1 (dBm)

STANDBY Can be also OFF,

Output Power Ra2 Text string Current output power Ra2 (dBm)

STANDBY Can be:

NA, ON, Remote Controlled

Output Power Ra1

Text string Indicates if the output power is set remotely for Ra1

OFF Can be:

NA, ON, Remote Controlled

Output Power Ra2 Text string Indicates if the output power is set remotely for Ra2

OFF Configured Output

Power Ra1

Text string Configured output power for Ra1 (dBm) 18 Configured Output

Power Ra2 Text string Configured output power for Ra2 (dBm) 18 Input Power Ra1 Text string Current input power Ra1 (dBm) -48.5 Input Power Ra2 Text string Current input power Ra2 (dBm) -48.5 Can be NA, ON, ATPC Enabled Text string Indicates if ATPC is enabled or not

OFF ATPC Max Output

Power Ra1 Text string Configured ATPC Max Output Power for

Ra1 (dBm) 17

ATPC Max Output

Power Ra2 Text string Configured ATPC Max Output Power for

Ra2 (dBm) 17

ATPC Target Input Text string Configured Target Input Power (dBm) -65

ServiceOn Microwave Element Manager - Operator Guide 2BElement Management User Interface

Fieldname Format Description Example

ATPC Target Input

Power Ra2 Text string Configured Target Input Power (dBm)

for the far end Ra2 -65

Can be:

NA, ON, Radio ID Check Text string Indicates that there is a check to

eliminate reception of traffic from any other radio but the correct far-end radio.

OFF AGC Alarm Threshold

Ra1

Text string AGC Alarm Threshold for Ra1 (dBm) AGC Alarm Threshold

Ra2 Text string AGC Alarm Threshold for Ra2 (dBm)

Can be:

10-3, 10-4, 10-5, BER Alarm Threshold Text string BER alarm threshold

10-giu Can be:

Auxiliary Input1 Text string Auxiliary unit whose alarm is handled

by MMU Ra1 Fan Unit, MXU

Unit, ETU Unit, Unknown Can be:

Auxiliary Input2 Text string Auxiliary unit whose alarm is handled

by MMU Ra2 Fan Unit, MXU

Unit, ETU Unit, Unknown Site ID Text string Site_ID from NE terminal properties

Hop Side ID Text string Hop_Side_ID from NE terminal

properties

Hop ID Text string Hop_ID ID from NE terminal properties Far Hop Side ID Text string Far_Hop_Side_ID from NE terminal

properties

Subnet ID Text string Sub-network id of the terminal Description Text string Description from NE terminal properties Traffic Rate

Description

Text string Traffic_Rate_Description from NE terminal properties

Can be:

0 Validity Text string Value 1 if collection valid, 0 otherwise

1

Table 2 MINI-LINK TN Configuration data for Radio Terminal (MMU2 B/C type)

Fieldname Format Description Example

Terminal_ID Text string ID of the MINI-LINK Terminal 001A Can be:

Unknown, MLE, MMU2, Equipment Type Text string The type of equipment

MMU2 B/C Can be:

1+0, Protection Mode

Admin Status Text string The equipment protection mode

1+1 Hot standby,

ServiceOn Microwave Element Manager - Operator Guide 2BElement Management User Interface

Fieldname Format Description Example

1+1 Working standby,

1+1 Hot standby s. d.,

1+1 Working standby s. d. , (s.

d. stands for space diversity) Capacity Text string Traffic capacity for terminal.

STM-1 Capacity Capability Text string Binary AND on contained MMUs and

RAUs capability

STM-1 Unknown C-QPSK, 16-QAM, Modulation Text string Modulation method for terminal.

This is only settable when according

to xfTermModulationCapability. 128-QAM Not available, 3002/4002, Access Server Port Text string rlXfMLTN:

Access server port used to reach far end terminals of type rlMLE or rlXfMLE, else notAvailable (1).

rlXfMLE:

Access server port used to reach a

3021/4021

ServiceOn Microwave Element Manager - Operator Guide 2BElement Management User Interface

Fieldname Format Description Example

Far End Terminal

Name Text string Remote Terminal Name F6/1+

For Default

"TRMB";

Far End ID Text string Expected network identity for remote terminal. Far End Type Text string Remote Terminal Type

MMU2 B/C Other, Enable, Remote ID Check Text string Check of remote terminal ID.

Disable BER Alarm Threshold Text string Threshold for BER alarm.

ber1e-6 Fade Notification

Timer Text string Notification suppress timer for

Protection alarms. Unit: seconds. 0 -1000 (default 200)

Other;

RTPC, ATPC,

Local Control, RA1 Local Control RA2 RTPC,

RA1 RTPC, Output Power Admin

Status Text string Configured output power mode

RA2 Local Control Other,

No ATPC, Support, Does not exist, ATPC , Capability , Unknown,

ATPC Capability Text string ATPC capability for the terminal, calculated as worst capability for all units contained in the terminal.

Supports , ATPC Protection RAU1

Instance Text string The textual name of the interface RAU1.

entPhysicalIndex for RAU1

2,12E+09

Protection RAU2

Instance Text string The textual name of the interface RAU2.

entPhysicalIndex for RAU2.

Tx Radio1, Tx Radio2, Active TX Radio Text string Active radio setting. Inherit actual

setting in manual mode.

Tx Radio1 and Tx , Radio2

Tx Radio1, Switch Revertive TX Text string Preferred Tx Radio.

Tx Radio2,

ServiceOn Microwave Element Manager - Operator Guide 2BElement Management User Interface

Fieldname Format Description Example

Off Unit1 Equipment Protection

Active Unit Text string This object indicates the active unit in respect to the TDM switch to the backplane. It can be used to perform an equipment protection switch. At creation of the EquipmentProtection is object indicates which unit is active at creation. At a node cold restart unit 1 will always be the active one.

Unit2

Automatic, Equipment Protection

Mode Text string This object applies for all switches involved in this protection, i.e.

equipment protection switches, line protection switches and specific switches like the Tx Radio switch.

The protection switches can be set into two modes:

Automatic: a switch will be performed upon a Signal Failure (SF)/Signal Degrade (SD) or equipment failure if the other line interface/unit is OK.

Manual: no switch due to SF/SD or equipment failure will be performed.

The switches are locked.

manual

Switch Interface

Name Text string Switch Interface Name 1/6+7/1

UP, Down, Switch Admin Status Text string Switch Admin Status

Testing

Hitless Phase;

TX Switch Over;

Switch Line

Protection Status Text string Switch Line Protection Status Extension to xfLineProtectionStatus

for the Switch Remote Tx Switch

Over Switch Line

Protection Working RX

Text string This object indicates the number of line switches since last node

warm/cold restart or protectioManual switches are included. This counter can be reseted using

xfTermPerfReset

1

RAU1 Instance Text string The textual name of the interface

RAU1. 1/6.1

UP, Down, RAU1 Admin Status Text string RA1 Admin Status

Testing Other, No Atpc, Support, RAU1 ATPC Capability Text string ATPC capability for the terminal RA1,

calculated as worst capability for all units contained in the terminal.

ServiceOn Microwave Element Manager - Operator Guide 2BElement Management User Interface

Fieldname Format Description Example

Atpc, Capability , Unknown,

Controlled Capability

Text string Indicates in the radio RA1 supports local transmit power control.

Supports Local Contol

RAU1 Modulation

Capability Text string Modulation Capability method for

RA1 terminal. -

RAU1 Freq Band Text string RAU Frequency Band Ra1 0..255 RAU1 Freq Index Text string RAU Frequency sub-band Ra1 0.255 RAU1 Temperature Text string Temperature in °Celsius inside radio

RA1

-127..127 Other, Rau Ra1, RAU1 Protection Path Text string Indicates what radio path the radio

RA1 belongs to.

Rau Ra2 RAU2 Instance Text string The textual name of the interface

RAU2. 1/7.1

UP, Down, RAU2 Admin Status Text string RA2 Admin Status

Testing Other, No Atpc , Support, Does Not Exist, Atpc ,

Capability , Unknown, RAU2 ATPC Capability Text string ATPC capability for the termina RA2,

calculated as worst capability for all units contained in the terminal.

Supports, Atpc Other,

No Local -Control , Support,

RAU2 Local

Controlled Capability Text string Indicates in the radio RA2 supports local transmit power control.

Supports Local Contol

RAU2 Modulation

Capability Text string Modulation Capability method for

RA2 terminal.

RAU2 Frequency Band

Text string RAU Frequency Band Ra2 0..255 RAU2 Frequency

Index Text string RAU Frequency sub-band Ra2 0..255

RAU2 Frequency

Temperature Text string Temperature in °Celsius inside radio

RA2 -127..127

Other, Rau Ra1, RAU2 Protection Path Text string Indicates what radio path the radio

RA2 belongs to.

Rau Ra2

ServiceOn Microwave Element Manager - Operator Guide 2BElement Management User Interface

Table 3 MINI-LINK TN Configuration data for Radio Terminal (MMU2 B/C type) part 2

Fieldname Format Description Example

RF1 Instance Text string The textual name of the interface RF1.

1/6.1/1 UP Down;

RF1 Admin Status Text string RF1 Admin Status

Testing RF1 Base TX Frequency Text string TX frequency in kHz when

frequency step number is 0 (zero) for RF1.

0..4294967295

RF1 Base RX Frequency Text string RX frequency in kHz when

frequency step number is 0 (zero) for RF1.

0..4294967295

RF1 Step Size Text string Frequency step size in kHz for RF1. 0..655335 RF1 Step Limit Low Text string Lowest allowed frequency step

number for RF1. 0..655335

RF1 Step Limit High Text string Highest allowed frequency step

number for RF1. 0..655335

RF1 Current Step Number

Text string Current frequency step number.

0 = RF frequency not yet defined.

(default)

Changing the far end values will result in loss of connection to far end. No confirm is supported in the far end. This is similar to the current MLE behavior. The set step number needs to be remembered and the near end has to be set to the same frequency to restore the connection.

0..655335

Other, TX Off, TX On, RF1 TX Oper Status Text string The actual status of transmitter for

RF1

TX Standby Other, TX Off, RF1 TX Admin Status Text string The desired status of transmitter for

RF1

TX On RF1 Current Output

Power Text string Output power in dBm including

attenuator for RF1. -100..35|255

RF1 Min Output Power

RF1 Text string Min output power in dBm including

attenuator for RF1. -100..35|255

RF1 Max Output Power Text string Max output power in dBm including attenuator for RF1.

-100..35|255 RF1 Select Output Power Text string Selected output power in dBm

including attenuator for RF1.

-100..35|255 RF1 ATPC Min Output

Power Text string Min output power in dBm in ATPC

mode for RF1. -100..35|255

RF1 ATPC Max Output

Power Text string Max output power in dBm in ATPC

mode for RF1. -99..-30|255

ServiceOn Microwave Element Manager - Operator Guide 2BElement Management User Interface

Fieldname Format Description Example

RF1 ATPC Select Input

Power Far End Text string Selected input target level [dBm]

for Far End radio in ATPC mode for RF1.

-99..-30|255

RF1 Attenuator Text string Attenuator value in dB for fixed output power attenuator mounted in RF1 radio.

0..100|255

RF1 Current Input Power Text string RF1 input level = value/10 dBm, -999...-200 RF1 Input Alarm

Threshold Text string RF input level threshold -99..-30

RF2 Instance Text string The textual name of the interface

RF2. 1/7.1/1

UP Down;

RF2 Admin Status Text string RF2 Admin Status

Testing Base_TX_Frequency_RF2 Text string TX frequency in kHz when

frequency step number is 0 (zero) for RF2.

0..4294967295

RF2 Base RX Frequency Text string RX frequency in kHz when

frequency step number is 0 (zero) for RF2.

0..655335

RF2 Step Size Text string Frequency step size in kHz for RF2. 0..655335 RF2 Step Limit Low Text string Lowest allowed frequency step

number for RF2 0..655335

RF2 Step Limit High Text string Highest allowed frequency step

number for RF2. 0..655335

Other, TX Off, TX On, RF2 Current Step

Number Text string Current frequency step number.

0 = RF frequency not yet defined.

(default)

Changing the far end values will result in loss of connection to far end. No confirm is supported in the far end. This is similar to the current MLE behavior. The set step number needs to be remembered and the near end has to be set to the same frequency to restore the connection.

TX Standby

Other, TX Off, RF2 TX Oper Status Text string The actual status of transmitter for

RF2

TX On RF2 TX Admin Status Text string The desired status of transmitter for

RF2 -100..35|255

RF2 Current Output Power

Text string Output power in dBm including attenuator for RF2

-100..35|255 RF2 Min Input Power Text string Min output power in dBm including

attenuator for RF2.

-100..35|255 RF2 Max Output Power Text string Max output power in dBm including

attenuator for RF2. -100..35|255

RF2 Select Output Power Text string Selected output power in dBm

including attenuator for RF2. -100..35|255

ServiceOn Microwave Element Manager - Operator Guide 2BElement Management User Interface

Fieldname Format Description Example

RF2 ATPC Min Output

Power Text string Min output power in dBm in ATPC

mode for RF2. -99..-30|255

RF2 ATPC_Max Output

Power Text string Max output power in dBm in ATPC

mode for RF2. -99..-30|255

RF2 ATPC Min Input

Power Far End Text string Min input target level [dBm] for Far

End radio in ATPC mode for RF2. -99..-30|255 RF2 ATPC Selected Input

Power Far End Text string Selected input target level [dBm]

for Far End radio in ATPC mode for RF2.

0..100|255

RF2 Attenuator Text string Attenuator value in dB for fixed output power attenuator mounted in RF2 radio.

-999..-200

RF2 Current Input Power Text string RF1 input level = value/10 dBm, -99..-30 RF2 Input Alarm

Threshold Text string RF input level threshold 0..4294967295

RAU IF1 Interface Name Text string Interface Name RAU_IF1 ########

UP, Down, RAU IF1 Admin Status Text string RAU_IF1 Admin Status

Testing RAU IF2 Interface Name Text string Interface Name RAU_IF2 ########

UP, Down, RAU IF2 Admin Status Text string RAU_IF2 Admin Status

Testing Can be:

0 Validity Text string Value 1 if collection valid, 0

otherwise

1

Table 4 MINI-LINK TN Configuration general data

Fieldname Format Description Example

Name Text string Name of the MINI-LINK Terminal

TN-141-137-100-26 Location Text string Location of the type of equipment location Contact Text string Contact of the type of equipment contact

DCN Host Name Text string DCN host name

TN-141-137-100-26

DCN Host Address Text string DCN host address 141.137.100.26

DCN Subnet Mask Text string DCN subnet mask 255.255.255.0

DCN Default Gateway Text string DCN Default Gateway saudit

DCN Domain Text string DCN Domain 141.137.100.10

DCN DNS Server1 Text string DCN DNS Server1

DCN DNS Server2 Text string DCN DNS Server2

DCN DNS Server3 Text string DCN DNS Server3

DCN NTP Server Text string DCN DNS Server 141.137.100.4

DCN DHCP Address Text string DCN DHCP Address

Validity Integer Value 1 if collection valid, 0 Can be:

ServiceOn Microwave Element Manager - Operator Guide 2BElement Management User Interface

0 1

Table 5 MINI-LINK TN Configuration data for Ethernet interfaces

Fieldname Format Description Example

Eth Interface Name Text string Interface Name

IP Address Text string IP Address

Subnet Mask Text string Subnet Mask

Enabled, Enable Notifications Text string Indicates whether traps should be

generated for this interface. disabled Speed Text string An estimate of the interface's current

bandwidth in bits per second 10000000 Auto, MDI MDIX Mode Text string indicates RX/TX configuration

Manual Can be:

0 Validity Text string Value 1 if collection valid, 0 otherwise

1

Table 6 MINI-LINK TN Configuration data for OSPF Area

Fieldname Format Description Example

Net Address Text string Net Address 141.137.100.26

Subnet Mask Text string Subnet Mask 0.0.0.0

Area ID Text string Identifier of the Area 1.0.0.0

Area Type Text string Type of Area stub area

totally stub Area Validity Integer Value 1 if collection valid, 0

otherwise Can be:

0 1

Table 7 MINI-LINK TN Configuration data for PPP interfaces

Fieldname Format Description Example

PPP Interface Name Text string Interface Name 1/3/1 SC1

Admin Status Text string Administrative Status Up; Down;

Testing Enable Notifications Text string Indicates whether traps should be

generated for this interface. Enabled disabled

IP Address Text string IP Address 141.137.100.11

Validity Integer Value 1 if collection valid, 0

otherwise Can be:

ServiceOn Microwave Element Manager - Operator Guide 2BElement Management User Interface

Fieldname Format Description Example

0 1

Table 8 MINI-LINK TN Configuration data for Static Routine

Fieldname Format Description Example

Destination Text string The destination IP address of this

route

Route Mask Text string Indicate the mask to be logical-ANDed with the destination address before being compared to the value in the ipCidrRouteDest field.

141.137.100.11

Gateway Text string On remote routes, the address of the next system en route;

Otherwise, 0.0.0.0.

141.137.100.11

Validity Integer Value 1 if collection valid, 0

otherwise Can be:

0 1

MINI-LINK E Data

Table 9 MINI-LINK E Data

Fieldname Format Description Example

Terminal ID Text string ID of the MINI-LINK Terminal 001A

Equipment Type Text string The type of equipment Can be_

MLE_1+0, MLE_1+1 Can be:

1+0, Protection Mode Text string The equipment protection mode

1+1Hot or 1+1Work

Traffic Rate Text string Configured traffic 2x2, 16xDS1

etc IDS In Own AMM Text string List of terminal IDs in the own AMM

001A-001B-501A

NCC AM No Text string Expanded NCC AM number Can be also

INACTIVE IDS In Connected Text string List of terminal IDs available on

001A-001B-ServiceOn Microwave Element Manager - Operator Guide 2BElement Management User Interface

Fieldname Format Description Example

IDS In Connected RTU Text string List of connected E_Micro terminal IDs E05B-E04B Can be: 1, 2, B

1 -> Ra1 2 -> Ra2 Active Radio Text string Indicates the Active Radio

B -> both Radio are transmitting (1+1 Work) Frequency Band Ra1 Text string RAU Frequency Band Ra1 15, 23 Frequency Index Ra1 Text string RAU Frequency sub-band Ra1 25, 58 Frequency Band Ra2 Text string RAU Frequency Band Ra2 15, 23 Frequency Index Ra2 Text string RAU Frequency sub-band Ra2 25, 58 Channel Spacing Text string Channel Spacing (MHz) 3.5, 7, 14 TX Frequency Ra1 Text string Transmitting Frequency Ra1 (MHz) 14950.00,

15006.00 TX Frequency Ra2 Text string Transmitting Frequency Ra2 (MHz) 14950.00, 15006.00 RX Frequency Ra1 Text string Receiving Frequency Ra1 (MHz) 14530.00,

14586.00 RX Frequency Ra2 Text string Receiving Frequency Ra2 (MHz) 14530.00,

14586.00 TX Attenuator Ra1 Text string Tx Attenuator value for Ra1 (dB)

TX Attenuator Ra2 Text string Tx Attenuator value for Ra2 (dB)

Can be also OFF,

Output Power Ra1 Text string Current output power Ra1 (dBm)

STANDBY Can be also OFF,

Output Power Ra2 Text string Current output power Ra2 (dBm)

STANDBY Can be:

NA, ON, Remote Controlled

Output Power Ra1 Text string Indicates if the output power is set

Output Power Ra1 Text string Indicates if the output power is set