Procedures using CLI interface for Package C ONTs
Procedure 5-41 To view current SLID settings
1 Choose option 4, Retrieve SLID, from the Main menu.
The system displays the string format, the mode, and the value of the SLID.
Example:
The SLID in ALPHANUMERIC MODE (Volatile) : DEFAULT
where the SLID settings are described in Table5-10
2 STOP. This procedure is complete.
Note — To enter or clear a slid:
• If you are using an Ethernet connection, the ONT must be disconnected from the PON optical cable.
• If you are using a craft connection, the ONT can be connected or disconnected from the PON optical cable. However, if you configure the SLID with the ONT connected to the PON optical cable, the data at the ONT is not changed; the data at the ONT is only changed after the ONT reranges. Rerange the ONT by disconnecting and reconnecting the PON optical cable, which generates a NEWONT alarm.
5 — ONT management using an ONT interface
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41 December 2010 5-61
Procedure 5-42 To clear the SLID
1 Perform one of the following:
a If you are using an Ethernet port, ensure that the ONT is disconnected from the PON optical cable.
b If you are using a craft port, you can clear the SLID with the ONT connected to or disconnected from the PON optical cable.
2 Choose option 5, Clear SLID, from the Main menu to clear the SLID.
The ONT sets the SLID to the default value, and the following message appears:
SLID cleared successfully!
3 Choose option 4, Retrieve SLID from the main menu to verify that the SLID is reset to its default value.
4 STOP. This procedure is complete.
Procedure 5-43 To enter the SLID
1 Perform one of the following:
a If you are using an Ethernet port, ensure that the ONT is disconnected from the PON optical cable.
b If you are using a craft port, you can enter the SLID with the ONT connected or disconnected from the PON optical cable.
2 Choose option 4, Retrieve SLID, from the Main menu to ensure that the SLID is set to DEFAULT or null.
3 Perform one of the following from the main menu
a Choose option 1, Enter SLID in volatile mode, to enter a volatile SLID.
b Choose option 2, Enter SLID in permanent mode, to enter a non-volatile SLID delivered in proprietary mode.
c Choose option 3, Enter SLID in registration mode, to enter a non-volatile SLID delivered in registration ID mode.
The following appears:
Enter Subscriber Location Id
> ALPHANUMERIC MODE (Length(1..10)):
> HEX MODE (Length(1..20))
> Note: FOR HEX MODE -- APPEND THE VALUE WITH 0x
4 Perform one of the following to enter the SLID value in alphanumeric or hexadecimal format:
a In alphanumeric format, enter the SLID up to 10 ASCII characters of 0 to 9, a to z, or A to Z.
b In hexadecimal format, enter the SLID up to 20 characters of 0 to 9, a to f, or A to F, with zeroes appended to a length of 20 characters.
5 Choose option 4, Retrieve SLID, to verify that the SLID was entered correctly.
6 Perform one of the following to connect the ONT to the PON:
a If the ONT is disconnected from the PON, connect the PON optical cable to the ONT.
b If the ONT is connected to the PON, disconnect, and then reconnect the PON optical cable.
7 Perform one of the following to provision the ONT and services:
a If the ONT and services were preprovisioned at the P-OLT, the P-OLT will automatically range and provision the ONT, after the ONT is connected to the PON optical cable.
b If the ONT and services were not preprovisioned at the P-OLT, notify the TL1 or network manager GUI operator to provision the ONT and services at the P-OLT using SLID.
8 STOP. This procedure is complete.
Procedures using HTTP interface for Package C ONTs
The following procedures provide the steps to view the current SLID settings and to enter a new SLID at the ONT using the HTTP interface for Package C ONTs.
Procedure 5-44 To view current SLID settings
1 Select the SLID option from the ONT Admin section of the navigation tree in the GPON ONT window.
The SLID window appears; see Figure 5-37.
Note — To enter or clear a SLID using an Ethernet connection, the ONT must be disconnected from the PON optical cable.
5 — ONT management using an ONT interface
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41 December 2010 5-63
Figure 5-37 SLID window
The current SLID settings are displayed in the Configured SLID and Current SLID fields.
2 If required, press Refresh to update the display of the configured and current SLID.
3 STOP. This procedure is complete.
Procedure 5-45 To enter the SLID
1 Select the SLID option from the ONT Admin section of the navigation tree in the GPON ONT window.
The SLID window appears; see Figure 5-38.
Figure 5-38 SLID window
2 Perform one of the following to enter the new SLID value in alphanumeric or hexadecimal format in the Input New SLID field:
a In alphanumeric format, enter a numeric string of up to 10 characters.
b In hexadecimal format, enter a numeric string of up to 20 characters. The string must be prefixed with a zero.
3 Press Apply.
4 STOP. This procedure is complete.
Procedures using CLI interface for Package C ONTs
The following procedures provide the steps to retrieve the current SLID and to modify the SLID using the CLI interface provided with Package C ONTs.