Procedures using CLI interface for Package C ONTs
Procedure 5-37 To perform a Protocol trace for a Package C ONT
1 Select the Protocol Trace option from the ONT Admin section of the navigation tree in the GPON ONT window.
The Protocol Trace window appears; see Figure 5-31.
Figure 5-31 Protocol Trace window
2 Select a tracing protocol by choosing either ARP, DHCP, or IGMP.
3 Click Start to initiate a protocol trace.
4 If necessary, click Stop to end a protocol trace.
5 Perform one of the following tasks with the tracing file produced by the protocol trace.
i Click Download to save the tracing file.
ii Click Delete to delete the tracing file.
6 STOP. This procedure is complete.
Procedures using CLI interface for Package C ONTs
Not applicable.Procedures using butt set
Not applicable.5.14 Activating an ONT using an SLID
The P-OLT is programmed to use the serial number or a SLID to activate a newly polled ONT on the PON with its provisioning data and services. The serial number is hard-coded into the ONT; the SLID is a hexadecimal or alphanumeric string that you enter locally into the ONT to uniquely identify the ONT on the PON.
After the P-OLT polls the PON for new ONTs, the ONT sends its SLID, range, and registration information to the P-OLT. The P-OLT matches the ONT with its provisioning data and services in the P-OLT database, using the serial number or the SLID. When a database match is found, the P-OLT downloads the provisioning data and services to the ONT, and the ONT and its services are activated.
5 — ONT management using an ONT interface
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41 December 2010 5-55
To activate an ONT using the serial number, the following is required:
• The ONT must be provisioned at the P-OLT with its serial number, a dummy SLID, provisioning data, and services.
• The ONT with the corresponding serial number must be installed at the customer site.
• The ONT must be connected to the GPON.
To activate an ONT using the SLID, the following is required:
• The ONT must be provisioned at the P-OLT with a dummy serial number, its SLID, provisioning data, and services.
• The ONT with any serial number must be installed at the customer site.
• The SLID in the ONT must be cleared locally, if the ONT has a non-default SLID.
• The SLID must be entered locally into the ONT.
• The ONT must be connected to the GPON.
Activation of an ONT can also be initiated by the P-OLT automatically at regular intervals or when one or more formerly registered and active ONTs become inactive.
In both cases, the frequency of the P-OLT polling is programmed by the user.
The SLID at the ONT can be stored in volatile or non-volatile mode. In volatile mode, the SLID is delivered to the P-OLT in proprietary mode; in non-volatile mode, the SLID can be delivered to the P-OLT in registration ID or proprietary mode. The SLID can be entered in hexadecimal or alphanumeric string format. See Table5-10 for more information about SLID settings
Note — The ONT and its services can be preprovisioned at the P-OLT before or after the ONT is installed.
Note — If you are reusing an ONT that was previously configured with a non-volatile SLID, the SLID must be reset to its default value.
If you are reusing an ONT that was previously configured with a volatile SLID, the SLID will automatically return to its default value when the ONT is powered off and on.
Table 5-10 SLID settings
This section shows you how to:
• view or retrieve the current SLID setting
• clear (reset) the SLID
• enter or modify a SLID
Prerequisites
The prerequisites are:
• To enter a SLID, the user access level of the ONT is read-write.
• To view current SLID settings, the user access level of the ONT is read only, or read-write.
• The ONT must have a SLID value of null or default before you can enter a new SLID. To reset a SLID to its default value, you must clear it.
• The steps to access the interface are completed.
• See Procedure5-1 for HTTP interface using the first Ethernet port.
• See Procedure5-3 for CLI interface using the craft port.
• See Procedure5-6 for HTTP interface for Package C ONTs.
• See Procedure5-7 for Package C ONT CLI interface using the craft port.
• See Procedure5-8 for Package C ONT CLI interface using an Ethernet port.
Parameter Value Description
Mode Volatile In volatile mode:
• The SLID at the ONT returns to its default value after the ONT is powered off and on.
• The SLID is delivered to the P-OLT in the proprietary mode, which uses the proprietary PLOAM message.
Permanent In permanent mode:
• The SLID at the ONT retains its configured value after the ONT is powered off and on.
• The SLID is delivered to the P-OLT in the proprietary mode, which uses the proprietary PLOAM message.
Registration In registration mode:
• The SLID at the ONT retains its configured value after the ONT is powered off and on.
• The SLID is delivered to the P-OLT in registration ID mode, which uses the password PLOAM message defined in G.984.3.
String format Hexadecimal Hexadecimal string of 0 to 9 and usually a to f or A to F, with zeroes appended to a length of 20 characters Alphanumeric String of up to 10 characters (default)
SLID value DEFAULT The ONT is set to a default value.
Non-default value —
5 — ONT management using an ONT interface
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41 December 2010 5-57
Procedures using HTTP interface
The following procedures provide the steps to view the current SLID settings, to clear the SLID, and to enter the SLID at the ONT using the HTTP interface.