Web monitor
Activates the web server functionality of the central remote control. This enables an easy and direct operation by means of the standard browser „Internet Explorer TM“ without requiring additional software.
Annual Schedule, Weekly Schedule
Upon activation, the timer functions of the weekly and yearly timer are considerably expanded, which enables an even more individual adjustment to the local requirements.
Sending Error Mail
System information, e.g. faults, room temperature curves, can automatically be sent to different users electronically via e-mail (additional hardware may be required). SMS via external serv- ice provider possible.
Personal Web
This function allows you to set up virtual remote controls. By using the Internet Explorer, these virtual remote controls can be called up on the standard PC monitor of the respective user.
Maintenance Tool
Enables access via the network by using the Mitsubishi Elec- tric maintenance tool software. Operating data of the units and systems can be visualised.*
Maintenance Tool Advance
Enables access via the network in order to visualise advanced unit and system parameters*
*PC with network access and maintenance tool software separately required
BACnet
This function allows you to communicate the information re- lated to the air conditioning systems to the building control system that is based on the BACnet protocol via an additional interface.
PLC for General Equipments
Extension of the ranges of functions of the GB-50ADA and AG- 150A using a Mitsubishi Electric PLC for controlling external units provided by the customer, for example fan motors. Ad- ditional installations provided by the customer may be required.
Energy Management License Pack
Enables the transfer of energy-displaying and energy-saving information and functions. This way, it is also possible to imple- ment a load shedding circuit. (Depending on the application, TG2000 or additional equipment required.)
Interlock control
Integration of functions of the central remote controls AG-150A and GB-50ADA into the auxiliary controller PACYG66DCA. This way, external units can be switched on/off via the timer of the central control, for instance. To this end, the corresponding activation codes, e. g. Annual Schedule, must be activated.
TG-2000A
The central remote control
becomes the building management system
The optionally available software TG-2000 is used to provide your central remote control AG-150A or GB-50ADA with ac- cess to existing building management systems. With its ad- ditional useful functions and the possibility to export data, the AG-150A or GB-50ADA can be integrated into the exist- ing building management system without any problems. You only require a standard PC by MELCO, a LAN network or a telephone connection.
Saving energy made easy
For peak load limitation, individual indoor units or groups can be programmed in such a way that their use of energy is opti- mised. This can be done by changing the target value, chang- ing the operating mode or switching the units off. You can set a night setback for times of less visitor traffic.
Central climate management
Individual units are simply connected via a network or tele- phone lines and operated and monitored centrally. This saves working time and therefore costs.
The software allows you to prepare a regular energy cost al- location for each individual customer. Simply export the ac- cumulated data to your IT department for further processing.
2000 indoor units? No problem!
The operating software TG-2000 allows you to integrate up to 40 GB-50ADA remote controls with 50 air conditioning units each into one network. This means that by using only a single PC, you can individually operate 2000 air conditioning units with a few mouse clicks.
Integration of external systems
Many other building technology systems that are working to- gether with the air conditioning system, for example the light- ing, can also be managed by the TG-2000, while the energy consumption can be recorded for the cost settlement.
Controlling and visualising
Simply start the software and the system data will automatically be imported and displayed graphically. This way, the data are always kept up to date.
The easy-to-understand and easily identifiable symbols pro- vide you with information on the operating status and other important details at the first glance already.
TG-2000A
Multi-functional, fully graphical operating software TG-2000 This symbol, for example, indicates that the indoor
unit with the designation Room 4a is in cooling mode (Cool), that it is switched on (green) and that the locale remote control is locked.
Cool
Room 4a
Display screen for a hallway section
Menu bar Function selection button
System status display
Ground-plan graphic (created externally) can be loaded
Enter key for the displayed hallway Symbol for a group
Selection buttons for the display mode Selection buttons for hallway/section Name of the displayed hallway/section
PAC-SC51KUA Hub AG-150 TG-2000A M-Net TG-2000A Functions Description
Operating system Pentium III, CPU 1000 Mhz, 256 MB RAM, at least 6 GB. LAN 10/100 Mbit/s Windows Professional 2000 SP4 or Windows Professional XP SP2 or Windows Vista max. number of controllable indoor units 2000 indoor units, 50 indoor units per AG-150A/GB-50ADA
Components of the software The software package is divided into two main areas: System and control settings:
System settings: Password protection, system configuration and group/block settings, printer setup. Control settings: Normal operation, monitoring and control functions as described below.
On/Off Display of operating status (On/Off) for each individual group, data is displayed on the selected screen (hallway, block, everything)
Operating mode Display of operating mode (cooling, heating, fan, drying, automatic mode) for each individual group, data is displayed on the selected screen (hallway, block, everything) Target room temperature Display of target temperature for each individual group, data is displayed on the selected screen (hallway, block, everything)
For heating and cooling, the setting range can be limited.
Fan levels Display of set fan level for each individual group, data is displayed on the selected screen (hallway, block, everything)
Locking and releasing Airflow angle: 100º – 80º – 60º – 40º and Auto Swing
Timer function Yearly or weekly timer, night setback (12 °C) integrated
Locking and releasing Display of status of the local remote controls (locked/released) for each individual group, data is displayed on the selected screen (hallway, block, everything) Fault messages The faults that did occur are saved for each indoor unit and can be exported and printed. Error lists can be called up, viewed, sorted by date or error removal, deleted or
printed individually or for the entire system.
Room temperature display Room temperature can be displayed in groups, measured at the master indoor unit of a group
Timer functions Display of timer status for each individual group, data is displayed on the selected screen (hallway, block, everything) Energy-saving functions Display of timer status for each individual group, data is displayed on the selected screen (hallway, block, everything)
Consumption data The following data can be saved: Actual and target room temperature, operating mode, On/Off switching cycles, el. power consumption per group, indoor unit or measur- ing device; Saved data can be sent via e-mail and allocated in order to visually simplify the arrangement and the locations of the air conditioning units in the systems. Group, indoor unit or measuring device; The saved data can be sent via e-mail.
Graphical representation The entire system can graphically be divided into screens, and a ground-plan graphic (bitmap) can be assigned to each screen in order to visually simplify the arrangement and the locations of the air conditioning units in the system.
E-mail function The following information can automatically be sent via e-mail on a regular basis: Energy consumption data, energy-saving data, temperature curves, error lists TG2000 PC-based software working in connection with the AG-150A / GB-50ADA controller