Name: Macro Enable/disable, SOP Inputs

Description: The variables in this structure are used to enable/disable the execution of macros from SOP input signals. Individual fields within this structure are described below.

Power Up: Changes to this variable must be made during a controlled start. User Interface Location: SYSTEM Variables screen

$MACRSOPENBL.$sop_emgop Minimum: 0 Default: 0 Maximum: 1

KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, SOP Emergency Stop Input

Description: Enables/disables the execution of macros from the SOP Emergency stop input. Power Up: Changes to this variable must be made during a controlled start.

User Interface Location: SYSTEM Variables screen $MACRSOPENBL.$sop_hold

Minimum: 0 Default: 0 Maximum: 1

KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, SOP Hold Input

Description: Enables/disables the execution of macros from the SOP HOLD input. Power Up: Changes to this variable must be made during a controlled start. User Interface Location: SYSTEM Variables screen

$MACRSOPENBL.$sop_pdi8

Minimum: 0 Default: 0 Maximum: 1

KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, SOP PDI8 Input

Description: Enables/disables the execution of macros from the SOP PDI8 input. Not currently used.

Power Up: Changes to this variable must be made during a controlled start. User Interface Location: SYSTEM Variables screen

$MACRSOPENBL.$sop_pdi9

Minimum: 0 Default: 0 Maximum: 1

KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, SOP PDI9 Input

Description: Enables/disables the execution of macros from the SOP pdi9 input. Not currently used.

Power Up: Changes to this variable must be made during a controlled start. User Interface Location: SYSTEM Variables screen

$MACRSOPENBL.$sop_pdia

Minimum: 0 Default: 0 Maximum: 1

KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, SOP PDIa Input

Description: Enables/disables the execution of macros from the SOP pdia input. Not currently used.

Power Up: Changes to this variable must be made during a controlled start. User Interface Location: SYSTEM Variables screen

$MACRSOPENBL.$sop_pdib Minimum: 0 Default: 0 Maximum: 1

KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, SOP PDIb Input

Description: Enables/disables the execution of macros from the SOP pdib input. Not currently used.

Power Up: Changes to this variable must be made during a controlled start. User Interface Location: SYSTEM Variables screen

Minimum: 0 Default: 0 Maximum: 1

KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, SOP PDIc Input

Description: Enables/disables the execution of macros from the SOP pdic input. Not currently used.

Power Up: Changes to this variable must be made during a controlled start. User Interface Location: SYSTEM Variables screen

$MACRSOPENBL.$sop_remote Minimum: 0 Default: 0 Maximum: 1

KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, SOP Remote Input

Description: Enables/disables the execution of macros from the SOP remote input. Power Up: Changes to this variable must be made during a controlled start.

User Interface Location: SYSTEM Variables screen $MACRSOPENBL.$sop_reset

Minimum: 0 Default: 0 Maximum: 1

KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, SOP Fault Reset Input

Description: Enables/disables the execution of macros from the SOP fault reset input. Power Up: Changes to this variable must be made during a controlled start.

User Interface Location: SYSTEM Variables screen $MACRSOPENBL.$sop_start

Minimum: 0 Default: 0 Maximum: 1

KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, SOP Cycle Start Input

Description: Enables/disables the execution of macros from the SOP cycle start input. Power Up: Changes to this variable must be made during a controlled start.

$MACRSOPENBL.$sop_tpdsc Minimum: 0 Default: 0 Maximum: 1

KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, SOP Teach Pendant Disconnect Input

Description: Enables/disables the execution of macros from the SOP Teach Pendant disconnect input.

Power Up: Changes to this variable must be made during a controlled start. User Interface Location: SYSTEM Variables screen

$MACRSOPENBL.$sop_tprel Minimum: 0 Default: 0 Maximum: 1

KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, SOP Teach Pendant Release

Description: Enables/disables the execution of macros from the SOP Teach Pendant Release input.

Power Up: Changes to this variable must be made during a controlled start. User Interface Location: SYSTEM Variables screen

$MACRSOPENBL.$sop_user1 Minimum: 0 Default: 1 Maximum: 1

KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, SOP User 1 Input

Description: Enables/disables the execution of macros from the SOP User 1 input. Power Up: Changes to this variable must be made during a controlled start. User Interface Location: SYSTEM Variables screen

$MACRSOPENBL.$sop_user2 Minimum: 0 Default: 1 Maximum: 1

KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, SOP User 2 Input

Description: Enables/disables the execution of macros from the SOP User 2 input. Power Up: Changes to this variable must be made during a controlled start.

User Interface Location: SYSTEM Variables screen $MACRTPDSBEX

Minimum: 0 Default: 0 Maximum: 1

KCL/Data: RW Program: RW GET/SET_VAR: RW Data Type: BOOLEAN Name: Enable/disable UK Macro

Description: Enables/disables the UK macro execution while the teach pendant is disabled. If set to TRUE, the UK macro is executable. If set to FALSE, the UK macro is not executable. Power Up: