Name: Macro Enable/disable, UOP Inputs
Description: The variables in this structure are used to enable/disable the execution of macros from the UOP input signals. Individual fields within this structure are described below.
Power Up: Changes to this variable must be made during a controlled start. User Interface Location: SYSTEM Variables screen
$MACRUOPENBL.$uop_cstop Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP Cycle Stop Input
Description: Enables/disables the execution of macros from the UOP Cycle stop input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MACRUOPENBL.$uop_enbl
Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP Enable Input
Description: Enables/disables the execution of macros from the UOP Enable input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MACRUOPENBL.$uop_estop
Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP Emergency Stop Input
Description: Enables/disables the execution of macros from the UOP Emergency stop input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MACRUOPENBL.$uop_hold
Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP HOLD Input
Description: Enables/disables the execution of macros from the UOP HOLD input. Power Up: Changes to this variable must be made during a controlled start. User Interface Location: SYSTEM Variables screen
$MACRUOPENBL.$uop_home Minimum: 0 Default: 1 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP Home Input
Description: Enables/disables the execution of macros from the UOP Home input. Power Up: Changes to this variable must be made during a controlled start. User Interface Location: SYSTEM Variables screen
$MACRUOPENBL.$uop_pdstrt Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP Production Start Input
Description: Enables/disables the execution of macros from the UOP Production start input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MACRUOPENBL.$uop_pnstrb
Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP PNS Strobe Input
Description: Enables/disables the execution of macros from the UOP PNS Strobe input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MACRUOPENBL.$uop_reset
Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP Fault Reset Input
Description: Enables/disables the execution of macros from the UOP Fault reset input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MACRUOPENBL.$uop_rsr1
Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP RSR1/PNS1 Input
Description: Enables/disables the execution of macros from the UOP RSR1/PNS1 input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MACRUOPENBL.$uop_rsr2
Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP RSR2/PNS2 Input
Description: Enables/disables the execution of macros from the UOP RSR2/PNS2 input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MACRUOPENBL.$uop_rsr3
Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP RSR3/PNS3 Input
Description: Enables/disables the execution of macros from the UOP RSR3/PNS3 input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MACRUOPENBL.$uop_rsr4
Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP RSR4/PNS4 Input
Description: Enables/disables the execution of macros from the UOP RSR4/PNS4 input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MACRUOPENBL.$uop_rsr5
Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP RSR5/PNS5 Input
Description: Enables/disables the execution of macros from the UOP RSR5/PNS5 input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MACRUOPENBL.$uop_rsr6
Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP RSR6/PNS6 Input
Description: Enables/disables the execution of macros from the UOP RSR6/PNS6 input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MACRUOPENBL.$uop_rsr7
Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP RSR7/PNS7 Input
Description: Enables/disables the execution of macros from the UOP RSR7/PNS7 input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MACRUOPENBL.$uop_rsr8
Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP RSR8/PNS8 Input
Description: Enables/disables the execution of macros from the UOP RSR8/PNS8 input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MACRUOPENBL.$uop_sfspd
Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP Safety Speed Input
Description: Enables/disables the execution of macros from the UOP Safety speed input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MACRUOPENBL.$uop_start
Minimum: 0 Default: 0 Maximum: 1
KCL/Data: RO Program: RO GET/SET_VAR: RO Data Type: BOOLEAN Name: Macro Enable, UOP Cycle Start Input
Description: Enables/disables the execution of macros from the UOP Cycle start input. Power Up: Changes to this variable must be made during a controlled start.
User Interface Location: SYSTEM Variables screen $MASTER_ENB
Minimum: 0 Default: 3 Maximum: 1
KCL/Data: RW Program: RW GET/SET_VAR: RW Data Type: INTEGER Name: Mastering Enable
Description: Specifies whether or not the SYSTEM Master/Cal screen will be displayed. If set to 1, the SYSTEM Master/Cal screen is displayed. If set to 0, the SYSTEM Master/Cal screen is not displayed.
Power Up: Changes to this variable take effect immediately. User Interface Location: SYSTEM Variables screen $MAXUALRMNUM
Minimum: 1 Default: 10 Maximum: 999
KCL/Data: RW Program: RW GET/SET_VAR: RW Data Type: INTEGER Name: Maximum Number of User-defined Alarm Messages that can be Defined
Description: Determines the size of the array $UALRM_MSG. Note that a controlled start is required to changed the size of the array. These messages are displayed by executing a UALM statement.
Power Up: Requires a controlled start to take effect. User Interface Location: SYSTEM Variables screen