2 System Structure
2.5 Software structure
2.5.1 Menu structure
1. Shortcut button area
When switching to any screen, a guidance bar will always be displayed on the left of the screen containing 10 frequently used shortcut buttons. Click them to perform the corresponding operations. The menu structure of the shortcut buttons is shown in Figure 2-8.
STAT Run Any screen
Diluent
Worklist
Graph
QC Table
Logout
Shutdown
Exit
Figure 2-8 Menu structure of the shortcut button area 2. “Run” message box
RUN
CT-PD AL-WB
CT-WB
Start
Ok
Cancel Start
Ok
Cancel
Start
Ok
Cancel
Figure 2-9 Menu structure of the “Run” message box 3. “Worklist” screen
At the “Worklist” screen, you can click the function buttons to perform the corresponding worklist-related operations.
The menu structure of the “Worklist” screen is shown in Figure 2-10.
Figure 2-10 Menu structure of the worklist screen 4. “Review” screen
The “Review” menu has five submenus: Graph, Table, Data Backup, Data Export and Compare. The Data Backup and Data Export functions can be enabled only when the analyzer has just been started up or you are at the “Table” review screen; otherwise, they grey out. The
“Table” review includes the functions of auto-backup and auto-restore, which will be performed automatically by the software when the condition of backup or restoring is fulfilled. The menu structures of each screen of the “Review” screen are shown below.
Graph
The menu structure of the graph review screen is shown in Figure 2-11.
Figure 2-11 Menu structure of the graph review screen
Table
The menu structure of the table review screen is shown in Figure 2-12.
TABLE
Figure 2-12 Menu structure of the table review screen
Data Export
The menu structure of the “Data Export” screen is shown in Figure 2-13.
Figure 2-13 Menu structure of the data export screen
Data Backup
The menu structure of the “Data Backup” screen is shown in Figure 2-14.
Figure 2-14 Menu structure of the data backup screen
Compare
The menu structure of the “Compare” screen is shown in Figure 2-15.
COMPARE Comparison Summary
Result Trend
Re-fill
Search
Re-fill
Search
Print Adjust Parameter
Order
Adjust Parameter Order
Figure 2-15 Menu structure of the compare screen 5. QC screen
The QC programs include the L-J QC, X-B QC, X QC and X-R QC. Click the shortcut button “QC” of the guidance bar on the left of the screen to enter the “L-J QC graph” screen.
Click “Menu” → “QC”, then the submenus of four QC programs will pop up for you to select.
L-J
The menu structure of the “L-J” QC program is shown in Figure 2-16.
X-B
The menu structure of the “X-B” QC program is shown in Figure 2-17.
X-B Settings
Figure 2-17 Menu structure of the “X-B” QC program
X
The menu structure of the “X ” QC program is shown in Figure 2-18.
X
X-R
The menu structure of the “X -R” QC program is shown in Figure 2-19.
-R
Figure 2-19 Menu structure of the “X-R” QC program
6. ”Service” screen
The “Service” screen contains screens of “Maintenance”, “Status”, “Self-test”, “Debug”,
screens are shown below.
“Maintenance” screen
The menu structure of the “Maintenance” screen is shown in Figure 2-20.
Figure 2-20 Menu structure of the “Maintenance” screen
“Status” screen
The menu structure of the “Status” screen is shown in Figure 2-21.
Status
Signal Collection
Export
Sensor Temperature&Pressure
Voltage&Current
Print Export
Print Export
Print Export
Figure 2-21 Menu structure of the “Status” screen
“Self-test” screen
The menu structure of the “Self-test” screen is shown in Figure 2-22.
Figure 2-22 Menu structure of the “Self-test” screen
“Debug” screen
The menu structure of the “Debug” screen is shown in Figure 2-23.
Figure 2-23 Menu structure of the “Debug” screen
“Counter” screen
The menu structure of the “Counter” screen is shown in Figure 2-24.
Figure 2-24 Menu structure of the “Counter” screen
“Log” screen
The menu structure of the “Log” screen is shown in Figure 2-25
Figure 2-25 Menu structure of the “Log” screen
“Version and Config. Information” screen
The menu structure of the “Version and Config. Information” screen is shown in Figure 2-26.
Figure 2-26 Menu structure of the “Version and Config. Information” screen
7. “Setup” screen
The “Setup” screen contains screens of “Gain”, “Data Format”, “Reagent”, “Auxiliary”, “Para.
Unit”, “Ref. Range”, “Print”, “Auto Maintenance”, “User and Password” and “Advanced”.
The menu structure of the “Setup” screen is shown in Figure 2-27.
Para. Unit
Figure 2-27 Menu structure of the “Setup” screen
8. “Statistics” screen
The menu structure of the “Statistics” screen is shown in Figure 2-28.
Figure 2-28 Menu structure of the “Statistics” screen
9. “Shortcut Code” screen
The menu structure of the “Shortcut Code” screen is shown in Figure 2-29.
Figure 2-30 Menu structure of the “Calibration” screen
11. “Help” info.
The menu structure of the “Help” screen is shown in Figure 2-31.
Contents
HELP Service
Review
Daily Operations
Setup
Calibration
QC Search
Figure 2-31 Menu structure of the “Help” screen
12. Shutdown
The menu structure of “Shutdown” is shown in Figure 2-32.
SHUTDOWN Sleep
Shutdown Figure 2-32 Menu structure of “Shutdown”
13. Exit
The menu structure of “Exit” is shown in Figure 2-33.
Figure 2-33 Menu structure of “EXIT”
2.5.2 Passwords
The passwords are divided into three levels: common user, administrator (set by the user at the “User and Password” screen) and service engineer (user name: “service”, and password:
“Se s700”. Note: there is a space between “e” and ”s”). An administrator is enabled to have all the authorities of a common user, and a service engineer is enabled to have all the authorities of an administrator. Tables below introduce the authorities enabled for each level of user.
Table 2-1 Authorities enabled for the common user level
Level Module Screen Authorities enabled
Common User
Worklist Worklist Users of three levels are enabled with all the authorities of the worklist screen, which including: “New”, “Save”, “Insert”,
“Delete”, “Search”, “Hide”,
“Select(Deselect)”, “Browse”, “Copy” and
“Print”.
Count All screens
Users of three levels are all enabled with the authority of running samples.
Graph Data/Graph, Saving of DIFF, Print, Pos./Total, Lock, Data Browse (the buttons of “Validate”, “Edit Result” and “Restore Result” are available, but when you click them, a message box will pop up for authority identification.)
Saving of the “Microscopic Exam. and Others” screen, Print, Pos./Total, Lock, Data Browsing and Setup of blood ESR ref.
range.
TABLE Save, Print, Communication, Deselect, Search, Trend Graph (cannot be printed), CV (cannot be printed), arrow buttons above the “Pos./Total” control (the buttons of “Validate”, “Batch Validate”, “Edit Result” and “Restore Result” are available, but when you click them, a message box will pop up for authority identification.)
Data Export Data Export Data Backup Data Backup
Compare Search and re-fill patient information, adjust and print parameters in the comparison summary, adjust and print parameters in the result trend.
Auto-backup Auto-backup Review
Auto-restore Auto-restore
L-J L-J QC setup: browse file information of different lot No.(but can not edit the QC settings), Print
L-J QC count: Start QC Run, Print and Pos./Total
L-J QC graph: New Vial, Data Compare, Display Order, Calculate Preset Values, Save Preset Values, Outliers, Print and Pos./Total
L-J QC table: Print, Communication, Data Backup, Data Export, History and Pos./Total
X-B X-B QC setup: browse the information of the screen but no edit allowed, Print
X-B QC graph: Calculate Preset Values, Save Preset Values, Print and Pos./Total X-B QC table: Print, Communication, Data Backup, Data Export, History and Pos./Total
QC
X X QC setup: browse file information of different lot No.(but can not edit the QC settings), Print
X QC count: Start QC Run, Print and Pos./Total
X QC graph: New Vial, Data Compare, Display Order, Calculate Preset Values, Save Preset Values, Outliers, Print and Pos./Total
X QC table: Print, Communication, Data Backup, Data Export, History and Pos./Total
X-R X-R QC setup: browse file information of different lot No.(but can not edit the QC settings), Print
X-R QC count: Start QC Run, Print and Pos./Total
X-R QC graph: New Vial, Data Compare, Display Order, Outliers, Print and Pos./Total
X -R QC table: Print, Communication, Data Backup, Data Export, History and Pos./Total
Maintenance Replace Reagent (“All Reagents”
unavailable), Clean, (“Empty WBC Bath”,
“Empty RBC Bath”, “Empty DIFF Bath”
all unavailable), Maintain the whole device Status Temperature&Pressure ( “Analyzer
Information” unavailable at the “Print”
message box), Voltage&Current (“Analyzer Information” unavailable at the
“Print” and “Export” message boxes)
Self-test Self-test for syringes and sampling mechanism, valves and others
Counter Check and print all the information
Log Check, print and see details of logs including “Set Paras”, “Other Logs” and
“All Logs”
Service
Version and Config.
Information
Check, export and print the information of the “Version and Config. Information”
screen General
Format
Date Format, Reagent, Auxiliary (“Authority” unavailable)
Setup
User and Password