• No results found

Offline Root Menu

In document OPTISONIC 7300 Handbook (Page 132-136)

9 Description of HART interface

9.11 HART Menu Tree

9.11.9 Offline Root Menu

Identification

Identification

Identification

Identification

Identification Tag / Descriptor / Message / Date

Device ManufacturerRd/ Device TypeRd/ Device IDRd/ Final Assembly Number / C numberRd/

Device Serial No.Rd/ Electronic Serial No.Rd

Detailed Setup

Detailed Setup

Detailed Setup

Detailed Setup

Mapping of Variables

Mapping of Variables PV is Rd/ SV is / TV is / QV is

Process Input

Calibration Meter Size / GK

Filter Minimum Limit / Maximum Limit / Flow Direction / Time Constant / Threshold Low Flow Cutoff / Hysteresis Low Flow Cutoff

Plausibility Error Limit / Counter Decrease / Counter Limit Information Serial Number Sensor / V Number Sensor VoS monitorOpt Monitor Velocity of Sound

Monitor Settings Opt Monitor Settings OptMonitor Settings Opt Monitor Settings Opt

Matching Factor / Actual Ratio Measurement/Calibration / VoS Tolerance / Time Constant Linearization Linearization / Dynamic ViscosityOpt

GeneralOpt Adiabatic Index

P&T CorrectionOpt P&T Correction / P&T InputsOpt/ Pipe TemperatureOpt/ Pipe PressureOpt/ DensityOpt

Diagnosis Value Diagnosis 1 / Diagnosis 2 / Diagnosis 3 HART Sensor s/n / <Align HART Units>

Actual Flow, Corrected Flow Actual Flow, Corrected FlowActual Flow, Corrected Flow

Actual Flow, Corrected FlowOptOptOptOpt, Enthalpy FlowEnthalpy FlowEnthalpy FlowEnthalpy FlowOptOptOptOpt, Mass Flow , , Mass Flow , , Mass Flow , , Mass Flow ,

Unit / Format / Upper Sensor Limit / Lower Sensor Limit / Minimum Span

I/O

Hardware Terminals A / Terminals B / Terminals C / Terminals D

Current Output A/B/COpt Range 0% Cust/ Range 100% Cust/ Extended Range Min Cust/ Extended Range Max Cust/ Error Current Cust/ Error Condition Cust/ Measurement Cust/ Range Min Cust/

133

www.krohne.com 08/2018 - 4001102304 - MA OPTISONIC 7300 R04 en

Limit Switch A/B/C/D Opt Measurement / Threshold / Hysteresis / Polarity / Time Constant / Invert Signal Control Input A/B Opt Mode Cust/ Invert Signal

Current Input A/BOpt Range 0%Rd/ Range 100%Rd/ Extended Range Min / Extended Range Max / Measurement / Range MinCust/ Range MaxCust/ Time Constant

Counter 1/2/3Opt Counter Function Cust/ Measurement Opt/ LFC Threshold Opt/ LFC Hysteresis Opt/ Time Constant Opt/ Preset Value Opt

I/O HART

I/O HART PV is Rd/ SV is / TV is / QV is

Device

Device Info Tag / C Number Rd/ Device Serial No. Rd/ Electronic Serial No. Rd

Display Language / Default Display Cust/ <SW.REV.UIS>

1./2. Meas. Page Function Cust/ Measurement 1.line / Range Min Cust/ Range Max Cust/

Limitation Min / Limitation Max / LFC Threshold / LFC Hysteresis / Time Constant / Format 1st Line / Measurement 2nd Line Opt, Cust/

Format 2nd Line Opt, Cust/ Measurement 3rd Line Opt, Cust/ Format 3rd Line Opt, Cust Graphic Page Select Range / Range Centre / Range +/- / Time Scale

Units Meter Size Unit / Volume Flow UnitCust/ Corrected Volume Flow UnitRd, Opt/

Extended Corrected Vol. Flow UnitOpt, Cust/ Enthalpy Flow UnitRd, Opt/

Extended Enthalpy Flow UnitOpt, Cust/ Mass Flow UnitCust/ Specific Enthalpy UnitRd, Opt/ Extended Specific Enthalpy UnitOpt, Cust/ Velocity Unit / Volume UnitCust/

Extended Volume UnitOpt, Cust/ Corrected Volume UnitRd, Opt/ Extended Corrected Volume UnitOpt, Cust/ Enthalpy UnitRd, Opt/ Extended Enthalpy Unit Opt, Cust/ Mass UnitCust/ Density UnitRd/ Extended Density UnitOpt, Cust/ Pressure UnitCust/ Temperature UnitCust

HART

HART HARTRd/ Online Mode?Loc

Identification IdentificationIdentification Identification

Polling address / Tag / Manufacturer Rd/ Model Rd/ Device ID Rd HART Revisions

HART RevisionsHART Revisions HART Revisions

Universal revision Rd/ Field device revision Rd/ DD-Version Rd Device Info

Device InfoDevice Info Device Info

Descriptor / Message / Date / Final assembly number / Software revision / Hardware revision / Write ProtectRd Preambles

PreamblesPreambles Preambles

Service

Service

Service

Service

Service Access Access Level HARTRd

Signal Data Transducer Type / Window Start / Window End / Pulse Form / Detection Method Detection Parameters

Detection ParametersDetection Parameters Detection Parameters

Trigger Level / Trigger Margin / Envelope Margin / Peak Margin / Number Of Peaks / Envelope Ratio 1 / Envelope Ratio 2 / Envelope Ratio 3 / Envelope Ratio 4 / RelmaxLow / RelmaxHigh / MaxTrackFactor / MaxTrackOffset / MaxTrackLimit / MaxTrackHit / MaxTrackLim / XcorrActive / <Set FixedWinloc> / Fixed Gain / Xdetect /

GainUnbalWarning / GainUnbalSigLost / XdetSNRLimit / XdetAverageNo / SNRLimSigLost / SNRLimWarning / Env. Shift monitor / Env. Ratio monitor Dead Time / <Impedance Test>

Delay Test Delay TestDelay Test Delay Test

Mode / TD Trigger LevelOpt/ TD Trigger MarginOpt/ TD Window StartOpt/ TD Window EndOpt/ TD Dead TimeOpt/ Repetition PingsOpt

Number Of Stacks / Number Of Bursts / Burst Period / Ping Time / Step-Up Voltage Path Data Number Of Paths / Velocity Of Sound / Path Length 1 /

Path Length 2 / Path Length 3 / Weight 1 / Weight 2 / Weight 3 / Beam Angle / T Expansion Coeff. / P Expansion Coeff. / Transducer Compression

Service Calibration Front End OptionRd

Zero Instrument Zero InstrumentZero Instrument Zero Instrument

Zero Offset Path 1 / Zero Offset Path 2 / Zero Offset Path 3 Zero Converter

Zero ConverterZero Converter Zero Converter

Path 1Rd/ Path 2Rd/ Path 3Rd

Service Info Detected C-No. Rd/ C-Number (8th Position)Rd/ Device Serial NumberRd/

135

www.krohne.com 08/2018 - 4001102304 - MA OPTISONIC 7300 R04 en

Temperature

Pressure

Process Analysis

Services Su bj ect t o chan ge wi th out no tice .

In document OPTISONIC 7300 Handbook (Page 132-136)

Related documents