9 Description of HART interface
9.11 HART Menu Tree
9.11.9 Offline Root Menu
Identification
Identification
Identification
Identification
Identification Tag / Descriptor / Message / Date
Device ManufacturerRd/ Device TypeRd/ Device IDRd/ Final Assembly Number / C numberRd/
Device Serial No.Rd/ Electronic Serial No.Rd
Detailed Setup
Detailed Setup
Detailed Setup
Detailed Setup
Mapping of Variables
Mapping of Variables PV is Rd/ SV is / TV is / QV isProcess Input
Calibration Meter Size / GK
Filter Minimum Limit / Maximum Limit / Flow Direction / Time Constant / Threshold Low Flow Cutoff / Hysteresis Low Flow Cutoff
Plausibility Error Limit / Counter Decrease / Counter Limit Information Serial Number Sensor / V Number Sensor VoS monitorOpt Monitor Velocity of Sound
Monitor Settings Opt Monitor Settings OptMonitor Settings Opt Monitor Settings Opt
Matching Factor / Actual Ratio Measurement/Calibration / VoS Tolerance / Time Constant Linearization Linearization / Dynamic ViscosityOpt
GeneralOpt Adiabatic Index
P&T CorrectionOpt P&T Correction / P&T InputsOpt/ Pipe TemperatureOpt/ Pipe PressureOpt/ DensityOpt
Diagnosis Value Diagnosis 1 / Diagnosis 2 / Diagnosis 3 HART Sensor s/n / <Align HART Units>
Actual Flow, Corrected Flow Actual Flow, Corrected FlowActual Flow, Corrected Flow
Actual Flow, Corrected FlowOptOptOptOpt, Enthalpy FlowEnthalpy FlowEnthalpy FlowEnthalpy FlowOptOptOptOpt, Mass Flow , , Mass Flow , , Mass Flow , , Mass Flow , …
Unit / Format / Upper Sensor Limit / Lower Sensor Limit / Minimum Span
I/O
Hardware Terminals A / Terminals B / Terminals C / Terminals D
Current Output A/B/COpt Range 0% Cust/ Range 100% Cust/ Extended Range Min Cust/ Extended Range Max Cust/ Error Current Cust/ Error Condition Cust/ Measurement Cust/ Range Min Cust/
133
www.krohne.com 08/2018 - 4001102304 - MA OPTISONIC 7300 R04 en
Limit Switch A/B/C/D Opt Measurement / Threshold / Hysteresis / Polarity / Time Constant / Invert Signal Control Input A/B Opt Mode Cust/ Invert Signal
Current Input A/BOpt Range 0%Rd/ Range 100%Rd/ Extended Range Min / Extended Range Max / Measurement / Range MinCust/ Range MaxCust/ Time Constant
Counter 1/2/3Opt Counter Function Cust/ Measurement Opt/ LFC Threshold Opt/ LFC Hysteresis Opt/ Time Constant Opt/ Preset Value Opt
I/O HART
I/O HART PV is Rd/ SV is / TV is / QV is
Device
Device Info Tag / C Number Rd/ Device Serial No. Rd/ Electronic Serial No. Rd
Display Language / Default Display Cust/ <SW.REV.UIS>
1./2. Meas. Page Function Cust/ Measurement 1.line / Range Min Cust/ Range Max Cust/
Limitation Min / Limitation Max / LFC Threshold / LFC Hysteresis / Time Constant / Format 1st Line / Measurement 2nd Line Opt, Cust/
Format 2nd Line Opt, Cust/ Measurement 3rd Line Opt, Cust/ Format 3rd Line Opt, Cust Graphic Page Select Range / Range Centre / Range +/- / Time Scale
Units Meter Size Unit / Volume Flow UnitCust/ Corrected Volume Flow UnitRd, Opt/
Extended Corrected Vol. Flow UnitOpt, Cust/ Enthalpy Flow UnitRd, Opt/
Extended Enthalpy Flow UnitOpt, Cust/ Mass Flow UnitCust/ Specific Enthalpy UnitRd, Opt/ Extended Specific Enthalpy UnitOpt, Cust/ Velocity Unit / Volume UnitCust/
Extended Volume UnitOpt, Cust/ Corrected Volume UnitRd, Opt/ Extended Corrected Volume UnitOpt, Cust/ Enthalpy UnitRd, Opt/ Extended Enthalpy Unit Opt, Cust/ Mass UnitCust/ Density UnitRd/ Extended Density UnitOpt, Cust/ Pressure UnitCust/ Temperature UnitCust
HART
HART HARTRd/ Online Mode?Loc
Identification IdentificationIdentification Identification
Polling address / Tag / Manufacturer Rd/ Model Rd/ Device ID Rd HART Revisions
HART RevisionsHART Revisions HART Revisions
Universal revision Rd/ Field device revision Rd/ DD-Version Rd Device Info
Device InfoDevice Info Device Info
Descriptor / Message / Date / Final assembly number / Software revision / Hardware revision / Write ProtectRd Preambles
PreamblesPreambles Preambles
Service
Service
Service
Service
Service Access Access Level HARTRd
Signal Data Transducer Type / Window Start / Window End / Pulse Form / Detection Method Detection Parameters
Detection ParametersDetection Parameters Detection Parameters
Trigger Level / Trigger Margin / Envelope Margin / Peak Margin / Number Of Peaks / Envelope Ratio 1 / Envelope Ratio 2 / Envelope Ratio 3 / Envelope Ratio 4 / RelmaxLow / RelmaxHigh / MaxTrackFactor / MaxTrackOffset / MaxTrackLimit / MaxTrackHit / MaxTrackLim / XcorrActive / <Set FixedWinloc> / Fixed Gain / Xdetect /
GainUnbalWarning / GainUnbalSigLost / XdetSNRLimit / XdetAverageNo / SNRLimSigLost / SNRLimWarning / Env. Shift monitor / Env. Ratio monitor Dead Time / <Impedance Test>
Delay Test Delay TestDelay Test Delay Test
Mode / TD Trigger LevelOpt/ TD Trigger MarginOpt/ TD Window StartOpt/ TD Window EndOpt/ TD Dead TimeOpt/ Repetition PingsOpt
Number Of Stacks / Number Of Bursts / Burst Period / Ping Time / Step-Up Voltage Path Data Number Of Paths / Velocity Of Sound / Path Length 1 /
Path Length 2 / Path Length 3 / Weight 1 / Weight 2 / Weight 3 / Beam Angle / T Expansion Coeff. / P Expansion Coeff. / Transducer Compression
Service Calibration Front End OptionRd
Zero Instrument Zero InstrumentZero Instrument Zero Instrument
Zero Offset Path 1 / Zero Offset Path 2 / Zero Offset Path 3 Zero Converter
Zero ConverterZero Converter Zero Converter
Path 1Rd/ Path 2Rd/ Path 3Rd
Service Info Detected C-No. Rd/ C-Number (8th Position)Rd/ Device Serial NumberRd/
135