ERROR E104:
Occurs: No room left in memory for dynamic allocation.
Action: Reduce memory usage by removing memory-resident programs and/or utilities. Refer to your installation instruction guide and/or your system administrator for suggestions.
ERROR E108:
Occurs: An unsupported device name was used, and there is no JEDEC information. Action: Use a supported device name that can be compiled. Check the user manual.
ERROR E109:
Occurs: The JEDEC Address File (JAF) for the specified target device is not found in the present drive/path. It has the part name as its filename, followed by the .JAF extension, e.g., EP224.JAF.
Action: Recheck the configuration file path variable (IPLSPATH) to be sure that the correct directories are included. If the path is okay, then reload the software in case the installed file has been corrupted.
ERROR E111:
Occurs: Could not write to a file on disk.
Action: Make sure the disk is not write-protected, and that there is adequate room on the disk for the files. A file name may have been corrupted. In DOS, run the CHKDSK program.
ERROR E113:
Occurs: Could not write to the JEDEC file on disk.
Action: Make sure the disk is not write-protected, and that there is adequate room on the disk for the files. A file name may have been corrupted. In DOS, run the CHKDSK program.
ERROR E114:
Occurs: JEDEC Address File for the device contains more data than can fit in the allocated memory space.
Action: Reinstall software from distribution media. If the error persists, contact Altera Applications at (800) 800-EPLD or (408) 894-7000 for assistance.
ERROR E115:
Occurs: Data contained in .CHP file does not match expected data.
Action: Run a disk diagnostic. If there are no problems, try rebooting the machine and removing any TSR programs. If the error persists, reinstall the software.
Error Messages
ERROR E116:
Occurs: An illegal JEDEC address was generated by the compiler. Action:
Step 1. Delete all temporary files on the disk. Run a disk diagnostic to make sure all files are not corrupted. Try to re-run the compiler.
Step 2. Gather all compiler input and output files in the design, and contact Altera Applications at (800) 800-EPLD or (408) 894-7000 for assistance.
ERROR E117:
Occurs: An illegal device resource was generated by the compiler. Action:
Step 1. Delete all temporary files on the disk. Run a disk diagnostic to make sure all files are not corrupted. Try to re-run the compiler.
Step 2. Gather all compiler input and output files in the design, and contact Altera Applications at (800) 800-EPLD or (408) 894-7000 for assistance.
ERROR E118:
Occurs: An illegal JEDEC equation was generated by the compiler. Action:
Step 1. Delete all temporary files on the disk. Run a disk diagnostic to make sure all files are not corrupted. Try to re-run the compiler.
Step 2. Gather all compiler input and output files in the design, and contact Altera Applications at (800) 800-EPLD or (408) 894-7000 for assistance.
ERROR E119:
Occurs: An internal compiler data structure was corrupted in memory. Action:
Step 1. Delete all temporary files on the disk. Run a disk diagnostic to make sure all files are not corrupted. Then try to re-run the compiler.
Step 2. Check that the PATHs in the configuration file point to the correct directories for the product. Try to reinstall the software.
Step 3. Remove TSRs and other memory resident programs.
Step 4. Gather all compiler input and output files in the design, and contact Altera Applications at (800) 800-EPLD or (408) 894-7000 for assistance.
ERROR E120:
Occurs: An illegal macrocell number was generated by the compiler. Action:
Step 1. Delete all temporary files on the disk. Run a disk diagnostic to make sure all files are not corrupted. Try to re-run the compiler.
Step 2. Gather all compiler input and output files in the design, and contact Altera Applications at (800) 800-EPLD or (408) 894-7000 for assistance.
ERROR E121:
Occurs: An unsupported macrocell control has been used. (e.g., PRESET or CLEAR on an EP224).
Action: Remove the equations driving these controls or implement the control signal synchronously rather than asynchronously. Check the report file to see if the design fit.
Error Messages
ERROR E122, E123:
Occurs: An internal compiler data structure was corrupted in memory. Action:
Step 1. Delete all temporary files on the disk. Run a disk diagnostic to make sure all files are not corrupted. Try to re-run the compiler.
Step 2. Gather all compiler input and output files in the design, and contact Altera Applications at (800) 800-EPLD or (408) 894-7000 for assistance.
ERROR E124:
Occurs: More product terms are included in the equation than are supported in the device. Action: Reduce the number of product terms in the equation or use minimization. Look for nested equations. It may be necessary to route part of the equation through an intermediate macrocell using NO-OUTPUT/COMBINATORIAL FEEDBACK or COMBINATORIAL OUTPUT/PIN FEEDBACK macrocell architectures. Consider using devices that support more p-terms.
ERROR E125:
Occurs: The compiler generated allocation data for a device that does not have any. Action:
Step 1. Delete all temporary files on the disk. Run a disk diagnostic to make sure all files are not corrupted. Then try to re-run the compiler.
Step 2. Gather all compiler input and output files in the design, and contact Altera Applications at (800) 800-EPLD or (408) 894-7000 for assistance.
ERROR E126:
Occurs: An internal compiler data structure was corrupted in memory. Action:
Step 1. Delete all temporary files on the disk. Run a disk diagnostic to make sure all files are not corrupted. Then try to re-run the compiler.
Step 2. Gather all compiler input and output files in the design, and contact Altera Applications at (800) 800-EPLD or (408) 894-7000 for assistance.
ERROR E127:
Occurs: An internal compiler data structure was corrupted in memory. Action:
Step 1. Delete all temporary files on the disk. Run a disk diagnostic to make sure all files are not corrupted. Then try to re-run the compiler.
Step 2. Check that the PATHs in the configuration file point to the correct directories for the product. Try to reinstall the software.
Step 3. Remove TSRs and other memory resident programs.
Step 4. Gather all compiler input and output files in the design, and contact Altera Applications at (800) 800-EPLD or (408) 894-7000 for assistance.
Error Messages