Using the AMS Control Panel to configure SNMP and SNMP alerts (Windows only) 1 Open the Agentless Management Service Control Panel.

In document HP ilo 4 User Guide. Abstract (Page 94-97)

Figure 41 Agentless Management Service Control Panel

3. Update the SNMP settings.

For a description of the available settings, see“Configuring SNMP settings” (page 90)and “Configuring SNMP alerts” (page 93).

4. Optional: ClickSend Test Trapto generate a test alert and send it to the TCP/IP addresses in theTrap Destination(s)boxes.

Test alerts include an Insight Management SNMP trap and are used to verify the network connectivity of iLO in HP SIM. Only users that have the Configure iLO Settings privilege can send test alerts.

After the alert is generated, a confirmation dialog box opens. Check the HP SIM console for receipt of the alert.

5. ClickApplyto save the configuration.

SNMP traps

Table 9 (page 96) lists the SNMP traps that you can generate with iLO and HP ProLiant Gen8 servers.

For more information about these SNMP traps, see the following files in the Insight Management MIB update kit for HP SIM:

• cpqida.mib • cpqhost.mib • cpqhlth.mib • cpqsm2.mib • cpqide.mib • cpqscsi.mib • cpqnic.mib

Table 9 SNMP traps

Description SNMP trap name

SNMP has been initialized, the system has completed POST, or AMS has started.

Cold Start Trap 0

SNMP has detected an authentication failure. Authentication Failure Trap 4

A change has been detected in the status of the Smart Array controller.

cpqDa6CntlrStatusChange 3033

A change has been detected in the status of a Smart Array logical drive.

cpqDa6LogDrvStatusChange 3034

A change has been detected in the status of a Smart Array cache module.

cpqDa6AccelStatusChange 3038

The Smart Array cache module has lost backup power. cpqDa6AccelBadDataTrap 3039

The Smart Array cache module backup power has failed. cpqDa6AccelBatteryFailed 3040

A change has been detected in the status of a Smart Array physical drive.

cpqDa7PhyDrvStatusChange 3046

A change has been detected in the status of a Smart Array spare drive.

cpqDa7SpareStatusChange 3047

A change has been detected in the SSD wear status of a Smart Array physical drive.

cpqDaPhyDrvSSDWearStatusChange 3049

The server was shut down due to a thermal anomaly and is now operational.

cpqHe3ThermalConfirmation 6026

One or more POST errors have occurred. cpqHe3PostError 6027

The fault-tolerant power supplies have lost redundancy for the specified chassis.

cpqHe3FltTolPowerRedundancyLost 6032

A fault-tolerant power supply has been inserted. cpqHe3FltTolPowerSupplyInserted 6033

A fault-tolerant power supply has been removed. cpqHe3FltTolPowerSupplyRemoved 6034

The fault-tolerant fan condition has been set toDegraded. cpqHe3FltTolFanDegraded 6035

The fault-tolerant fan condition has been set toFailed. cpqHe3FltTolFanFailed 6036

The fault-tolerant fans have lost redundancy. cpqHe3FltTolFanRedundancyLost 6037

A fault-tolerant fan has been inserted. cpqHe3FltTolFanInserted 6038

A fault-tolerant fan has been removed. cpqHe3FltTolFanRemoved 6039

The temperature status has been set toDegraded, and the temperature is outside the normal operating range. Depending on the system configuration, this system might be shut down. cpqHe3TemperatureDegraded 6041

The temperature status has been set toOK. cpqHe3TemperatureOk 6042

The fault-tolerant power supply condition has been reset toOK. cpqHe4FltTolPowerSupplyOk 6048

The fault-tolerant power supply condition has been set toDegraded. cpqHe4FltTolPowerSupplyDegraded 6049

The fault-tolerant power supply condition has been set toFailed. cpqHe4FltTolPowerSupplyFailed 6050

The Advanced Memory Protection subsystem has detected a memory fault. Mirrored Memory has been activated. cpqHeResilientMemMirroredMemoryEngaged 6051

The fault-tolerant power supplies have returned to a redundant state.

cpqHe3FltTolPowerRedundancyRestore 6054

The fault-tolerant fans have returned to a redundant state. cpqHe3FltTolFanRedundancyRestored 6055

Table 9 SNMP traps(continued)

Description SNMP trap name

Memory errors have been corrected, but the memory module should be replaced.

cpqHe5CorrMemReplaceMemModule 6064

The fault-tolerant power supply in the specified chassis and bay reported AC power loss.

cpqHe4FltTolPowerSupplyACpowerloss 6069

The server power has been reset. cpqSm2ServerReset 9001

The maximum unauthorized login attempt threshold has been exceeded.

cpqSm2UnauthorizedLoginAttempts 9003

iLO 4 has detected a Self Test Error. cpqSm2SelfTestError 9005

iLO 4 has detected that the security override jumper has been toggled to the engaged position.

cpqSm2SecurityOverrideEngaged 9012

iLO 4 has detected that the security override jumper has been toggled to the disengaged position.

cpqSm2SecurityOverrideDisengaged 9013

The server has been powered on. cpqSm2ServerPowerOn 9017

The server has been powered off. cpqSm2ServerPowerOff 9018

A request was made to power on the server, but the server could not be powered on because of a failure condition.

cpqSm2ServerPowerOnFailure 9019

Generic trap. Verifies that the SNMP configuration, client SNMP console, and network are operating correctly. You can use the cpqHo2GenericTrap 11003

iLO web interface to generate this alert to verify receipt of the alert on the SNMP console.

A power threshold has been exceeded. cpqHo2PowerThresholdTrap 11018

A change in the health status of the server has occurred. cpqHoMibHealthStatusArrayChangeTrap 11020

AMS detected a change in the status of an SAS or SATA physical drive.

cpqSasPhyDrvStatusChange 5022

AMS detected a change in the status of an ATA disk drive. cpqIdeAtaDiskStatusChange 14004

AMS detected that connectivity was restored to a logical network adapter.

cpqNic3ConnectivityRestored 18011

AMS detected that the status of a logical network adapter changed toFailed.

cpqNic3ConnectivityLost 18012

In document HP ilo 4 User Guide. Abstract (Page 94-97)