Entering a New Label Using the LCD Keypad
SETTING UP THE UTILITY OUTPUT TO TRIGGER THE NOISE SOURCE:
B- ZONE PRMS: ZONE#=001 (M:ZZ)
B-ZONE PRMS: ZONE#=001 (M:ZZ)
2. Select the zone that the BUS zone detector was assigned to and press / . The BUS Zone parameters menu appears.
3. Use the below tables to configure the parameters for each BUS Zone detector type. Zones Miscellaneous: BUS Zone – iWISE DT Grade 2
Quick Keys Parameter Default Range
22 00 33 ZZZZ 11 LEDS On
Defines the LEDS operation mode. [1] Off - Disables the LEDS operation. [2] On - Enables the LEDS operation.
Zones Miscellaneous: BUS Zone – iWISE DT Grade 2
Quick Keys Parameter Default Range
22 00 33 ZZZZ 22 MW (Microwave) Range Trimmer Defines the microwave channel range.
[1] Minimum [2] 25% [3] 50% [4] 65% [5] 85% [6] Maximum [7] Trimmer (MW is defined by the trimmer setting on the PCB)
22 00 33 ZZZZ 33 ACT No
Defines the Anti-Cloak™ Technology (ACT) operation mode. [1] No - Disables the ACT mode.
[2] Yes - Enables the ACT mode. 22 00 33 ZZZZ 44 Automatic Microwave
Bypass
No
Defines whether the MW channel will be bypassed or not while the detector identifies trouble in the MW channel.
[1] No - While detecting a problem in the MW channel it is not bypassed. Alarm condition cannot be established until the MW channel is fixed.
[2] Yes - Switches the detector to operate only in PIR mode in case of MW trouble.
22 00 33 ZZZZ 55 Green Line Yes
A feature that follows environmental guidelines by avoiding surplus emission This feature defines the activation of the microwave channel while the system is disarmed.
[1] No - Green Line feature is disabled. MW is constantly activated. [2] Yes - Green Line feature is activated.
22 00 33 ZZZZ 66 Self Test Remote
Used to test the detection technologies. In the event of a failed test, a Self Test Trouble is created
[1] Remote (Manual) - The remote self test is performed by the system when a user manually selects the Diagnostics option from the Maintenance menu via the ProSYS User Functions menu
[2] Local (automatic) - Once an hour, the detector automatically checks that the detector’s channels are functioning properly.
Zones Miscellaneous: BUS Zone – Lunar Grade 3/iWISE DT Grade 3
Quick Keys Parameter Default Range
22 00 33 ZZZZ 11 LEDS On
Defines the LEDS operation mode. [1] Off - Disables the LEDS operation. [2] On - Enables the LEDS operation. 22 00 33 ZZZZ 22 MW (Microwave) Range Trimmer
Defines the microwave channel range.
[1] Minimum [2] 25% [3] 50% [4] 65% [5] 85% [6] Maximum [7] Trimmer (MW is defined by the trimmer setting on the PCB)
Zones Miscellaneous: BUS Zone – Lunar Grade 3/iWISE DT Grade 3
Quick Keys Parameter Default Range
22 00 33 ZZZZ 33 ACT No
Defines the Anti-Cloak™ Technology (ACT) operation mode. [1] No - Disables the ACT mode.
[2] Yes - Enables the ACT mode. 22 00 33 ZZZZ 44 Automatic Microwave
Bypass
No
Defines whether the MW channel will be bypassed or not while the detector identifies trouble in the MW channel.
[1] No - While detecting a problem in the MW channel it is not bypassed. Alarm condition cannot be established until the MW channel is fixed.
[2] Yes - Switches the detector to operate only in PIR mode in case of MW trouble.
22 00 33 ZZZZ 55 Green Line Yes
This option conforms to environmentally friendly standards by avoiding surplus emission This feature defines the activation of the microwave channel while the system is disarmed.
[1] No - Green Line feature is disabled. MW is constantly activated. [2] Yes - Green Line feature is enabled.
22 00 33 ZZZZ 66 Anti-Mask Enable Defines the operation of Anti Masking detection.
[1] Disable [2] Enable and behaves according to the settings defined in quick keys [2][0][3][zz][7].
22 00 33 ZZZZ 77 Arm/Disarm No
Defines the operation of the anti masking detection while the detector is armed or disarmed.
[1] No – While armed or disarmed, anti-mask behaves according to the setting defined in quick keys [2][0][3][zz][6] above.
[2] Yes – While armed, anti-mask is disabled. When detector is disarmed Anti- mask behaves according to the settings defined in quick keys [2][0][3][zz][6]. 22 00 33 ZZZZ 88 Self Test Remote
Used to test detection technologies. In the event of a failed test, a Self Test Trouble is created.
[1] Remote (manual) - Performed by the system when a user manually selects the Diagnostics option from the Maintenance menu via the ProSYS User Functions menu.
[2] Local (automatic) - Once an hour, the detector automatically checks that the detector’s channels are functioning properly.
Zones Miscellaneous: BUS Zone – iWISE QUAD Grade 2
Quick Keys Parameter Default Range
22 00 33 ZZZZ 11 LEDS On
Defines the LEDS operation mode. [1] Off - Disables the LEDS operation. [2] On – Enables the LEDS operation. 22 00 33 ZZZZ 22 Sensitivity High
Defines the sensitivity of the detector (PIR). [1] Low [2] High
22 00 33 ZZZZ 33 Self Test Remote
Used to test detection technologies. In the event of a failed test, a Self Test Trouble is created.
[1] Remote (manual) - Performed by the system when a user manually selects the Diagnostics option from the Maintenance menu via the ProSYS User Functions menu.
[2] Local (automatic) - Once an hour, the detector automatically checks that the detector’s channels are functioning properly.
Zones Miscellaneous: BUS Zone – iWISE QUAD Grade 3
Quick Keys Parameter Default Range
22 00 33 ZZZZ 11 LEDS On
Defines the LEDS operation mode. [1] Off - Disables the LEDS operation. [2] On – Enables the LEDS operation. 22 00 33 ZZZZ 22 Sensitivity High
Defines the sensitivity of the detector (PIR). [1] Low [2] High
22 00 33 ZZZZ 33 Anti-Mask Enable Defines the operation of Anti Masking detection.
[1] Disable [2] Enable and behaves according to the settings defined in quick keys [2][0][3][zz][4]
22 00 33 ZZZZ 44 Arm/Disarm No
Defines the operation of the anti masking detection while the detector is armed or disarmed
[1] No – While armed or disarmed, anti-mask behaves according to the setting defined in quick keys [2][0][3][zz][3] above.
[2] Yes – While armed, anti-mask is disabled. While detector is disarmed Anti- mask behaves according to the settings defined in quick keys [2][0][3][zz][3]. 22 00 33 ZZZZ 55 Self Test Remote
Used to test detection technologies. In the event of a failed test, a Self Test Trouble is created.
[1] Remote (manual) - Performed by the system when a user manually selects the Diagnostics option from the Maintenance menu via the ProSYS User Functions menu.
[2] Local (automatic) - Once an hour, the detector automatically checks that the detector’s channels are functioning properly.
Zones Miscellaneous: BUS Zone – WatchOUT PIR
Quick Keys Parameter Default Range
22 00 33 ZZZZ 11 LEDS 3 LEDS