CATALOGUE
Revision 2012
UNINTERRUPTIBLE
POWER SUPPLY (UPS)
Protecting Your Data
Table of Contents
About Us - Company Profile
Online UPS
Professional Series (1P/1P) - Tower Master Series (1P/1P) - Tower Master Series (1P/1P) - Combo
Master Series (1P/1P) - 2-in-1 Rack/ Tower Master Series (3P/1P) - Tower
Master Series (3P/1P) - Rack Mount Master Series (3P/3P) - Tower Power Series (3P/3P)
Line Interactive UPS PRO Series
Inverter UPS IPS Series
Solar UPS
PDC Series - DC UPS PCC Series
PSI Hybrid Series PSI On-Grid Series PSI Off-Grid Series PSS Series
Software & Accessories Appendixz
2
4 4 6 10 12 16 18 21 23
27 27
28 28
31 31 32 33 34 35 36 37 41
Our Mission
Accentuate The Best For The E-generation
PROLiNK® aspires to accentuate the best for the e-generation. With technology becoming an essential aspect of modern living, the e-generation concept has gradually become ingrained in our lives and digital literacy is becoming more and more commonplace.
PROLiNK products are designed to make technology work for the e-generation. Created with the end-user in mind, our products are crafted to enhance performance whether you are at work or play – our products work harder, while you work smarter to achieve your desired results with less effort and better efficiency.
Providing value to our consumers – whether home or business users, remains a firm commitment of PROLiNK. With its wide range of quality products, PROLiNK makes it easy for home users to find user-friendly yet affordable solutions for their technological needs, while business users are assured of reliable and secure solutions for their network infrastructure.
Our Vision
Ideas, Innovation and Information
PROLiNK® aims to be the key driving force behind technological changes and improvements in both developing and developed countries. With its strong focus on technology, our team sets high standards for itself in the areas of innovation, change and improvement so as to provide the next generation of users with products that are suitable for their technology advanced environments.
The small “i” in PROLiNK represents ideas, innovation and information – three key pillars of growth that drive us towards achieving excellence in our field of expertise and challenges us to think beyond our usual boundaries.
Fida International (S) Pte Ltd has been a provider of technologically innovative and user-friendly products manufac- tured under the brand name “PROLiNK®” since 1991. With more than two decades of professional experience in the information communications sector, PROLiNK is now renowned as a specialist in its field, especially in area of Backup UPS products.
Over the years, PROLiNK has built its presence through a strong foundation of technological leadership within the South Asian, South-east Asian and Middle Eastern regions and is continuing to build its presence worldwide. With its current network of sales offices in more than 20 countries, customers can be assured that PROLiNK is able to provide the right solutions to meet the needs of both home and business users within each geographical location both efficiently and effectively.
The company’s quest for continuous improvement and quality assurance to its customers has earned us the ISO9001 quality certification since 1999. With its consistently strong commitment to quality, customers can be assured of they are getting true value - superior quality products at affordable prices.
Core Values
Secured Information Management
With more than two decades of professional experience in providing backup power solutions to our customers, we are able to support our customers with superior technological know-how and expertise, as well as advice on market trends. At the same time, we are also fully committed to protecting the privacy of our customers and to manage confidential information discreetly.
Innovative Design
Our products are carefully thought out to ensure that each item is designed to meet the needs of our customers. With the team’s solid experience in the UPS market, customers can be certain that our designs are innovative yet functional, and suitable for each dynamic market that we have a presence in.
Superior Service Standards
Strict and rigorous testing makes up a huge part of our quality control procedures. We ensure that every item meets our strict standards – from the individual components to the actual finished product.
Total Quality Assurance System
Our products go through careful planning and checks at every stage of the production cycle - from the beginning stages of product design to the manufacturing and finally the actual delivery of the goods. This guarantees that our customers receive only the best quality goods – of high reliability and durability. Our total quality system has been audited and approved by globally recognized bodies.
Range of UPS
The wide range of our products gives you an infinite range of solutions:
1. Online UPS
2. Line Interactive UPS 3. Inverter UPS 4. Solar UPS
Online Professional Series 1KVA – 6KVA
Work-Stations Service
Rear Panel
PRO901S/
PRO902S PRO901L/
PRO902L PRO903S/
PRO906S PRO903L/
PRO906L
Professional Series (1P/1P) - Tower
The Professional Series (1P/1P) - Tower is an advanced, affordable on-line double-conversion technology single-phase UPS system. Professional Series is available with 1000VA to 6000VA models and these offer high reliability for workstations, server and network equipment.
The Professional Series is designed to protect against power outages, disturbances and spikes. It also provides high-efficient charger with PFC. High battery charging current and battery extension assembly is available for the long run time application. In order to supply pure and clean power to sensitive devices, an optional of isolation transformer can be attached to UPS unit without taking extra space.
• True Double-Conversion Online UPS
• Wide input voltage range (110~300VAC)
• Input Power Factor correction 0.98
• Output Power Factor 0.80
• Generator compatible
• LCD User Interface
• RS-232 communication port or mini slot for USB / RS-232 / AS400 / SNMP communication
• Smart battery charger design for optimized battery performance
• Optional isolation transformer available
Local Area Network (LAN)
PRO901S/ L
PRO902S/ L PRO903S/ L PRO906S/ L
5 6
9 4 3
2 1
5 6
9 4 3
2 1
5
9
3 2
7 1 8 4 6
5
9
3 2
7 1 8 4
6
For 1KVA to 6KVA model
1. Output receptacles 2. AC input
3. Input circuit breaker
4. Network/Fax Modem Surge Protection 5. RS-232 communication port /
SNMP intelligent slot 6. External battery connection (only available for L model) 7. Output terminal
8. Output circuit breaker 9. Fan
Small Computer Network
Full Specifications Options
• RS-232 Port for communication.
• AS-400 Card for external alarm signal.
• SNMP Card for data communication via network connection.
• Output Isolation Transformer.
• External PDU & Maintenance Bypass Switch. (suitable for UPS up to 3KVA only)
50 or 60Hz
110Vac < Vin < 290Vac @ 50% LOAD/ 168Vac < Vin < 300Vac @ 100% LOAD 208/ 220/ 230/ 240VAC
Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor
40 ~ 70Hz
≧ 0.98
6000 VA/ 4800 W
Capacity 1000 VA/ 800 W 2000 VA/ 1600 W 3000 VA/ 2400 W
Valve regulated Lead Acid battery (Maintenance free batteries) Type
Capacity Liner Load Non-Liner Load
Recharge Time (Typical) Charging Current Standard Model
Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI62040-2; EN62040-3 Regulations
INPUT
MODELS PRO901S/ L PRO902S/ L PRO903S/ L PRO906S/ L
OUTPUT
BATTERY
MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD
INDICATORS EFFICIENCY
Support Windows® 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB
1.5 sec
>130%
100% < Load < 110%
LCD Display AC Mode
±1% ±3%
0.8 Static Regulation
Frequency Range Frequency
Power Factor Current Crest Ratio
Voltage Distortion ≦ 3% THD
≦ 6% THD ≦ 7% THD
≦ 4% THD
Waveform
1.0 A (max) 47 ~ 53 Hz or 57 ~ 63 Hz 50Hz or 60Hz auto selection
Pure Sinewave
9AH
4 hours recover to 90% capacity Up to 88%
3:1
10AH
Type Long-Run Model Capacity
Charging Current 4.0 A or 8.0 A (max)
Overload warning only (No shutdown)
100% < Load < 130% 30 sec
Depending on the application Depending on the application 200/ 208/ 220/ 230/ 240VAC Output Voltage
397×145×220 17.2
8.9
421 × 190 × 318
421×190×318 28
13.5
426 × 190 × 318
426×190×318 35.3
14.3
<90% non-condensing 0°C - +40°C Operation Humidity
Ambient Temperature
≤ 45dBA @ 1 Meter Noise Level
397 x 145 x 220 9.3
4.8 Dimension (mm) D x W × H
Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) Standard Model
Long-Run Model
L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Specification for Online UPS with Isolation Transformer to be provided upon request.
Symbols: “/” meant for OR; “×” meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.
Online Master Series 1KVA – 10KVA
Work-Stations Service
Rear Panel
Master Series (1P/1P) - Tower
Master Series (1P/1P) - Tower is a true on-line double-conversion technology single-phase UPS system which provides clean, high level quality power for critical devices such as small computer centers, servers, telecom applications and industrial applications. It is available from 1KVA to 10KVA capacities with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes.
Master Series (1P/1P) - Tower is designed with a smart battery charger to optimize battery performance. High battery charging current and battery extension assembly is available for long run applications. Internal bypass to assure continuous power to critical devices during UPS maintenance and parallel redundancy which will back up the load in the event of critical component failure is available for the 6KVA and 10KVA models. An optional of isolation transformer can be attached to UPS unit without taking extra space.
• True Double-Conversion Online UPS
• Wide input voltage range (110~300VAC)
• Input Power Factor correction 0.99
• Output Power Factor 0.80
• Generator compatible
• LCD User Interface
• RS-232 communication port or mini slot for USB/ RS-232/
AS400/ SNMP communication
• Smart battery charger design for optimized battery performance
• Optional isolation transformer available
Local Area Network (LAN)
PRO802S/ L PRO803S/ L PRO801S/ L
PRO8015S/ L PRO806S/ L PRO810S/ L
For 1KVA to 3KVA model
1. Programmable outlets: connect to non- critical loads
2. Output receptacles: connect to mission- critical loads
3. AC input
4. Input circuit breaker
5. Network/Fax/Modem surge protection 6. Emergency power off function connector (EPO)
7. USB communication port 8. RS-232 communication port 9. SNMP intelligent slot
10. External battery connection (only available for L model)
11. Output terminal 12. Output circuit breaker 13. Fan
Small Computer Network
PRO802S/
PRO803S PRO802L/
PRO803L PRO801S/
PRO8015S PRO801L/
PRO8015L 6 85 9
7
13 4
3 2
1
9 6 85 7
13 10
4
3 2
1
9 5 13
13 2 1
7 8
6
4 3
95
2 1
7 8
6
4 3 13 10
13
Battery Pack
For 1KVA to 3KVA model
For 6KVA to 10KVA model
1. RS-232 communication port 2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model) 6. Intelligent slot
7. Charger fan 8. Power stage fan
9. Maintenance bypass switch 10. Input circuit breaker 11. Input/Output terminal 12. Output terminal 1 13. Output terminal 2
14. External battery terminal (only available for Long-run model)
15. Utility input terminal 16. Output IEC Socket
9
5 5 2
1
8 7
8
6 4 3
15 12 13
16 11
10
9
5 5 2
1
8 7
8
6 4 3
15 12 13
14
16 11
10
For 6KVA to 10KVA model
PRO806S/
PRO810S PRO806L/
PRO810L
Capacity Battery Type Battery Number Dimension (DxWxH) Weight (kg)
1KVA/ 1.5KVA
6 pcs
18
6 pcs 397×145×220
20
12 pcs
36
2KVA/ 3KVA
12 pcs 18 pcs 18 pcs
421×190×318
40 55
12V9AH
12V7AH 12V7AH 12V9AH 12V7AH 12V9AH
535×190×318 61
Capacity Battery Type Battery Number Dimension (DxWxH) Weight (kg)
20 pcs
64
20 pcs 592×250×576
72
40 pcs
109
6KVA/ 10KVA
40 pcs 60 pcs 60 pcs
592×250×576
125 166
12V9AH
12V7AH 12V7AH 12V9AH 12V7AH 12V9AH
830×250×576 190
Full Specifications Options
• AS-400 Card for external alarm signal.
• SNMP Card for data communication via network connection.
• Output Isolation Transformer.
• External PDU & Maintenance Bypass Switch. (suitable for UPS up to 3KVA only)
50 or 60Hz
110Vac <Vin<290Vac @ 50% LOAD / 175Vac <Vin<300Vac @ 100% LOAD 208/ 220/ 230/ 240VAC
Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor
40 ~ 70Hz
≧ 0.99
3000 VA/ 2400 W
Capacity 1000 VA/ 800 W 1500 VA/ 1200 W 2000 VA/ 1600 W
Valve regulated Lead Acid battery (Maintenance free batteries) Type
Capacity
Recharge Time (Typical) Charging Current Standard Model
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations
INPUT
MODELS PRO803S/ L
6000 VA/ 4800 W PRO806S/ L
10000 VA/ 8000 W PRO810S/ L PRO801S/ L PRO8015S/ L PRO802S/ L
OUTPUT
BATTERY
MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD
INDICATORS EFFICIENCY
Support Windows® 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232
2.0 sec
>130%
100% < Load < 110%
LCD Display AC Mode
±1%
0.8 Static Regulation
Frequency Range Frequency
Power Factor Current Crest Ratio
Voltage Distortion Linear Load Non-Linear Load
≦ 3% THD ≦ 3% THD
≦ 6% THD ≦ 7% THD ≦ 6% THD
≦ 4% THD
Waveform
1.0 A (max) 47 ~ 53Hz or 57 ~ 63Hz 50Hz or 60Hz auto selection or selectable
Pure Sinewave
9AH 7AH 9AH 7AH
7AH
4 hours recover to 90% capacity 9 hours recover to 90% capacity Up to 89%
3:1
9AH
Type Long-Run Model Capacity
Charging Current 8.0 A (max) 4.0 A (max)
Overload warning only (No shutdown)
100% < Load < 130% 30 sec
Depending on the application Depending on the application 200/ 208/ 220/ 230/ 240VAC Output Voltage
397×145×220
26 28
13
421 × 190 × 318
421×190×318
81
13
592 x 250 x 576
592 x 250 x 576 83
25 27
<90% non-condensing 0°C - +40°C Operation Humidity
Ambient Temperature
≤45dBA @ 1 Meter ≤55dBA @ 1 Meter ≤58dBA @ 1 Meter
Noise Level
397 x 145 x 220
13 14
7 7
Dimension (mm) D x W × H Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) Standard Model
Long-Run Model
Derate to 60% of capacity in Frequency converter mode and to 80% when the output valtage is adjusted to 208VAC.
If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Specification for Online UPS with Isolation Transformer to be provided upon request.
Symbols: “/” meant for OR; “×” meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.
Programmable Outlets (P1) - connect to non-critical devices
True double-conversion Online UPS
A true double conversion UPS will provide clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer centers, servers, telecom applications, as well as for industrial applications.
Higher Accuracy For Output Voltage
With advanced control firmware, Master Series (1P/1P) provides high accuracy within +/- 1% for output voltage.
It can be applied to precious test & IT equipment.
Smart Battery Charger Design To Optimize Battery Performance
• Master Series (1P/1P) 1-3KVA is equipped with 2-stage charger design to guarantee battery discharge time.
Besides, it will adjust charging voltage according to outside temperature. This features will extend the useful service life of batteries.
• Master Series (1P/1P) 6KVA and above models are equipped with 3-stage extendable charger for optimized battery performance. This feature extends the useful service life of batteries and optimizes battery recharge time. Besides, the extendable charger design can be stacked in numbers for large-capacity battery charging.
DSP Technology Applied For 6KVA And Above Models
A DSP controller provides an improved and cost-effective solution with high performance.
Maintenance Bypass Available For 6KVA And Above Models
Internal bypass assures continuous power to critical devices during UPS maintenance.
Optional Hot Standby Mode And N+X Parallel Redundancy Available For 6KVA And Above Models
For genuinely redundant power protection, Master Series (1P/1P) (6KVA and above models) can either be used in parallel operation with up to 3 units or hot standby mode. Slave UPS will back up the load in the event of critical component failure. It increases power safety and availability.
Adjustable Battery Numbers For 6KVA And Above Models
Master Series (1P/1P) (6KVA and above models) can still normal operate well with only 18 or 19 internal batteries.
Built-in Isolation Transformer (Option)
With built-in isolation transformer, the UPS will offer full isolation and complete common mode noise rejection for connected precious equipment. It become an ideal power source with 100% protection against unexpected AC power problems.
Output Power Factor 0.8
Compared to the online UPSs in the current market, Master Series (1P/1P) provides better output power factor up to 0.8. It offers higher performance and efficiency for critical applications.
Wide Input Voltage Range (110 V -300 V)
Master Series (1P/1P) can still provide stable power to connected devices under unstable power environments.
50/60 Hz Frequency Converter Mode
Lock output frequency at 50Hz or 60Hz to suit power sensitive equipments.
ECO Mode Operation For Energy Saving
Offers efficiency as high as 97% to cut energy usage &
cost. UPS power application via static bypass, timely returning to online double conversion when the need arises.
Emergency Power Off (EPO) Function
This feature can secure the personnel and equipment in case of fires or other emergencies.
SNMP + USB + RS-232 Multiple Communications For 1-3KVA Models
This feature allows either USB or RS-232 communication port to work with SNMP interface simultaneously.
Programmable Power Management Outlets
With programmable power management outlets, users can easily and indepenntly control load segments. During power failure, this feature enables users to extend battery time to missioncritical devices by shutting down the non-critical devices.Online Master Series 6KVA – 10KVA
Work-Stations Service
Rear Panel
Master Series (1P/1P) - Combo
Master Series (1P/1P) - Combo is designed with a very small footprint size to solve the problem of limited space with the support of 6kVA and 10kVA UPS system. Master Series (1P/1P) – Combo used true on-line double-conversion technology single-phase UPS system which provides clean, high level quality power for critical devices such as small computer centres, servers & telecom applications.
Master Series (1P/1P) - Combo is available from 6KVA and 10KVA capacities with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes. Smart battery charger design to optimize battery performance and high battery charging current and battery extension assembly is available for long run applications.
• True double-conversion on line UPS
• DSP technology guarantees high performance
• Wide input voltage range (110-300 VAC)
• Active input power factor correction 0.99
• Output power factor 0.8
• 50Hz/60Hz frequency converter mode
• Standard backup UPS and long backup UPS in one integrated unit
• Adjustable battery number from 16 blocks to 20 blocks
• Adjustable charging current can be changed via LCD or software (1A~6A)
• Emergency power off function (EPO)
• USB and RS-232 communications port and mini slot for AS400/ SNMP communication.
• Maintenance bypass available
Local Area Network (LAN)
For 6KVA to 10KVA model
1. RS-232 communication port 2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Intelligent slot 5. Power stage fan
6. Maintenance bypass switch 7. Input circuit breaker 8. Input/Output terminal
9. External battery terminal (only available for Long-run model)
10. Battery Compartment (only available for Standard model)
Small Computer Network
PRO806C/
PRO810C PRO806CL/
PRO810CL
PRO806CL/
PRO810CL
5 5
6 8 9
7 4 3 2 1
5 5
6 8
7 4 3 2 1
10
PRO806C/
PRO810C
Full Specifications Options
• AS-400 Card for external alarm signal.
• SNMP Card for data communication via network connection.
• Output Isolation Transformer.
50 or 60Hz
110Vac <Vin<290Vac @ 50% LOAD / 176Vac <Vin<300Vac @ 100% LOAD 208/ 220/ 230/ 240VAC
Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor
46 ~ 64Hz
≧ 0.99
Capacity 6000 VA/ 4800 W 10000 VA/ 8000 W
Valve regulated Lead Acid battery (Maintenance free batteries) Type
Capacity
Recharge Time (Typical) Charging Current Standard Model
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations
INPUT
MODELS PRO806C/ CL PRO810C/ CL
OUTPUT
BATTERY
MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD
INDICATORS EFFICIENCY
Support Windows® 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232
1.0 sec
>130%
100% < Load < 110%
LCD Display AC Mode
±1%
0.8 Static Regulation
Frequency Range Frequency
Power Factor Current Crest Ratio
Voltage Distortion Linear Load
Non-Linear Load ≦ 5% THD
≦ 3% THD
Waveform
1.0 A (max) 46 ~ 54Hz or 56 ~ 64Hz 50Hz or 60Hz auto selection or selectable
Pure Sinewave
9AH
9 hours recover to 90% capacity Up to 90%
3:1
Type Long-Run Model Capacity
Charging Current 6.0 A (max)
10 mins
100% < Load < 130% 1 min
Depending on the application Depending on the application 200/ 208/ 220/ 230/ 240VAC Output Voltage
360 x 192 x 318
440 x 192 x 688
440 x 192 x 318
<95% non-condensing 0°C - +40°C Operation Humidity
Ambient Temperature
≤55dBA @ 1 Meter ≤58dBA @ 1 Meter
Noise Level
360 x 192 x 688
60 75
21 23
Dimension (mm) D x W × H Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) Standard Model
Long-Run Model
L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Specification for Online UPS with Isolation Transformer to be provided upon request.
Symbols: “/” meant for OR; “×” meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.
Online Master Series 1KVA – 10KVA
Work-Stations Service 19” Rack Mount
Master Series (1P/1P) - 2-in-1 Rack/ Tower
Master Series (1P/1P) – 2-in-1 Rack/Tower is a true on-line double-conversion technology single-phase UPS system with 2U universal-mount case. It can be easily installed as a floor-standing tower or with a 19-inch rackmount bracket.
The Master Series was designed with a high density output power factor of 0.9 to provide higher performance and efficiency to critical applications such as sensitive networks, small computer centers, servers and telecom applications. It is available in capacities from 1KVA to 10KVA with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes.
Master Series (1P/1P) - 2-in-1 Rack/Tower has been designed with a hot-swappable battery to ensure clean and uninterruptible power to protected equipment during battery replacement. A high battery charging current and battery extension assembly is available for long run applications. Parallel redundancy which will back up the load in the event of critical component failure is available for the 6kVA and 10kVA models. Front panel digital display can be easily adjusted through LCD setting to suit the installation format, whether it is left vertically standing or flat wall mounted.
• True Double-Conversion Online UPS
• Rack or Tower design
• Wide input voltage range (110~300VAC)
• Input Power Factor correction 0.99
• Output Power Factor 0.90
• 50/60Hz frequency converter mode
• Hot-Swappable battery design
• Emergency Power Off (EPO) function
• ECO Mode Operation for energy saving
• General Compatible
• Charger capacity expansion to 8A for long-run models
• SNMP+USB+RS232 multiple communications
• Smart battery charger design for optimized battery performance
• Selectable output voltage via LCD panel
Local Area Network (LAN) Small Computer
Network
PRO801RS to PRO803RS/
PRO801RL to PRO803RL
PRO806RS/ PRO810RS/
PRO806RL/ PRO810RL
PRO803RL
5 12 12 10
7
8 9 6 1 2
3
4 11
Rear Panel
For 1KVA to 3KVA model
1. Programmable outlets:Connect to non-critical loads 2. Output receptacles: Connect to mission-critical loads 3. AC input
4. Input circuit breaker
5. Network/Fax/Modem surge protection
6. Emergency power off function connector (EPO) 7. USB communication port
8. RS-232 communication port 9. SNMP intelligent slot
10. Battery Compartment (only available for Standard model) 11. Input terminal
12. Fan
PRO801RS/PRO8015RS/PRO802RS
5 12 6 10
7 8 9
1 2
3 4
PRO801RL/PRO8015RL/PRO802RL
5 12 6 10
7 8 9
1 2
3 4
PRO803RS
5 12 12 10
7
8 9 6 1 2
3 4 11
Options
• AS-400 Card for external alarm signal.
• SNMP Card for data communication via network connection
• MODBUS Card for communication
• Universal Rackmount Slider for installation in rack cabinets
• External PDU & Maintenance Bypass Switch (suitable for UPS up to 3KVA only)
• Maintenance Bypass Switch [MBS] (for UPS 6 to 10KVA only)
• External Automatic Transfer Switch (ATS)
PRO806RS/RL PRO810RS/RL
9 6 4
7 7
12
10 14
13
11 16 15
Battery Pack
For 1KVA to 10KVA model
Capacity Battery Type Battery Number Dimension (DxWxH) Weight (kg)
1KVA 1.5KVA 2KVA
8 pcs
31.1
6 pcs 480×438×88
29.1
8 pcs
31.1
3KVA 6KVA 10KVA
12 pcs 20 pcs
43.3 57
12V9AH 12V7AH 12V9AH
580×438×133 600×438×88
63
For 6KVA to 10KVA model
1. Programmable outlets:Connect to non-critical loads 2. Output receptacles: Connect to mission-critical loads 3. AC input
4. Input circuit breaker
5. Network/Fax/Modem surge protection
6. Emergency power off function connector (EPO) 7. USB communication port
8. RS-232 communication port 9. SNMP intelligent slot
10. Battery Compartment (only available for Standard model) 11. Input terminal
12. Fan
13. Parallel port (only available for parallel model) 14. External maintenance by-pass switch connection 15. Output Terminal
16. Ground
MBS-rack-UK Schuko IEC NEMA ATS-R MBS - 6 to 10K
Full Specifications
50 or 60Hz
120Vac <Vin<290Vac @ 50% LOAD / 170Vac <Vin<300Vac @ 100% LOAD 208/ 220/ 230/ 240VAC
Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor
40 ~ 70Hz
≧ 0.99 3000 VA Capacity Active Power (Standard Model)
Active Power (Long-Run Model)
Apparent Power 1000 VA 1500 VA 2000 VA
Valve regulated Lead Acid battery (Maintenance free batteries) Type
Capacity
Recharge Time (Typical) Charging Current Standard Model
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations
INPUT
MODELS PRO803RS/ RL
6000 VA PRO806RS/ RL
10000 VA 2700 VA
900 VA 1350 VA 1800 VA 5400 VA 9000 VA
2400 VA
800 VA 1200 VA 1600 VA 4800 VA 8000 VA
PRO810RS/ RL PRO801RS/ RL PRO8015RS/ RL PRO802RS/ RL
OUTPUT
BATTERY
MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD
INDICATORS EFFICIENCY
Support Windows® 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232
2.0 sec 1 sec
>130%
100% < Load < 110%
LCD Display AC Mode
±1%
0.9 @ Standard Model, 0.8 @ Long-Run Model Static Regulation
Frequency Range Frequency
Power Factor Current Crest Ratio
Voltage Distortion Linear Load
Non-Linear Load ≦ 8% THD ≦ 6% THD ≦ 4% THD
≦ 2% THD
Waveform
1.0 A (max) 47 ~ 53Hz or 57 ~ 63Hz 50Hz or 60Hz auto selection or selectable
Pure Sinewave
9AH 7AH
4 hours recover to 90% capacity 9 hours recover to 90% capacity Up to 90%
3:1
5:1 5:1 3:1
9AH
Type Long-Run Model Capacity
Charging Current 4.0 A or 8.0 A (max) 4.0 A (max) 4.0 A (max)
Overload warning only (No shutdown) 10 mins
100% < Load < 130% 30 sec 1 min
Depending on the application Depending on the application 200/ 208/ 220/ 230/ 240VAC Output Voltage
380x438x88 (2U) 480x438x88 (2U)
20.6 28
11.3 480x438x88 (2U)
600x43x88(2U)
UPS Unit: 17
Battery Pack: 57 UPS Unit: 20 Battery Pack: 63
13.8
Battery Unit:
580x438x133 (3U) UPS Unit:
580x438x133 (3U)
Battery Unit:
580x438x133 (3U) UPS Unit:
688x438x133 (3U) 600x438x88 (2U)
580x438x133 (3U) 668x438x133 (3U)
17 20
<90% non-condensing 0°C - +40°C Operation Humidity
Ambient Temperature
≤50dBA @ 1 Meter Noise Level
380x438x88 (2U)
12.9 17.6
8.6 10.7
Dimension (mm) D x W × H
Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) Standard Model
Long-Run Model
L means Long-run model; S means Standard model.
Symbols: “/” meant for OR; “×” meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.
Programmable Outlets (P1) - connect to non-critical devices
True Double-conversion Online UPS
A true double conversion UPS will provide clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer centers, servers, telecom applications, as well as for industrial applications.
Programmable Power Management Outlets
With programmable power management outlets, users can easily and independently control load segments.During power failure, this feature enables users to extend battery time to mission critical devices by shutting down the non-critical devices.
ECO And Advanced ECO Mode For Energy Saving
It allows UPS to operate in high efficiency up to 97%in energy saving ECO mode and even up to 98%. In this operation mode, load is supplied by the mains. In the event of a mains failure, the inverter takes over the load and provides supply continuity to the connected systems.Emergency Power Off Function (EPO)
This feature can secure the personnel and equipment in case of fires or other emergencies.
Hot-swappable Battery Design
This design ensures clean and uninterruptible power to protected equipment during battery replacement.
Long-run Models Available
To provide longer backup time, we also offer long-run models. If additional runtime is required, matching external battery units is available.
User-friendly And Easy-shift LCD Display
The front panel digital display can be easily shifted through LCD setting to suit the installation format, verti- cally stand or flat wall mount.Rack/ Tower Design
Master (1P/1P) - 2-in-1 Rack/Tower Series is designed in true 2U universal-mount case. It can be easily installed as floor-standing tower or in 19-inch rack- mount bracket.
Higher Output Crest Radio Perfect For Generator And Compressor
Compared to general online UPS, Master (1P/1P) - 2-in-1 Rack/Tower Series provide higher current crest ratio as 5:1. It can support not only precious IT equipment, but also compressors and motor-type devices.
Output Voltage Regulation < 1%
Master (1P/1P) - 2-in-1 Rack/ Tower Series offers better output voltage regulation (+/-1%), which ensures higher compatibility with even the most sensitive power supplies.
Output power factor 0.9
Master (1P/1P) - 2-in-1 Rack/Tower Series is a high- density UPS with output power factor 0.9 to provide higher performance and efficiency to critical applications.
Rack Display Tower Display
19” Rack-mounting Floor-standing Tower
Online Master Series 10KVA – 20KVA
Master Series (3P/1P) - Tower
Master Series (3P/1P) - Tower is a true on-line double-conversion technology three-phase input / single-phase output UPS system which ensure maximum protection and power quality for any type of load, especially for mission critical applications such as data center systems, security systems, industrial processes and telecommunications. It is available from 10KVA to 20KVA capacities with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes.
Master Series (3P/1P) - Tower with built in phase auto adapt function simplifies wire installation and single phase input is acceptable. With IGBT technology, it provides generator compatible where handles frequency variations and other power fluctuations that occur during generator operation. Internal bypass to assure continuous power to critical devices during UPS maintenance and parallel redundancy which will back up the load in the event of critical component failure is available. An optional of isolation transformer can be attached to UPS unit without taking extra space.
• True Double-Conversion Online UPS
• DSP technology guarantees high performance
• Output Power Factor 0.80
• Input Power Factor Correction 0.99
• Wide input voltage range
• Active power factor correction in all phases
• 50/60Hz frequency converter mode
• Emergency Power Off (EPO) function
• SNMP+USB+RS232 multiple communications
• Adjustable battery numbers
• Maintenance bypass available
• Optional N+X parallel redundancy
• Optional isolation transformer available
Rear Panel
PRO83110S/L PRO83115L/
PRO83120L
PRO83115S/
PRO83120S
CentreData Electro-Medical
Device Storage
PLCS Emergency Alarm Devices
E-Business (Server Farms,
ISP/ASP/POP) Local Area
Network (LAN)
Telecommunication Devices
For 10KVA model
1. RS-232 communication port 2. USB communication port
3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot
7. Charger fan 8. Power stage fan
9. Maintenance by-pass switch 10. Input circuit breaker
11. Output circuit breaker for receptacles
12. Output receptacles: connect to mission-critical loads 13. Input/Output terminal
14. External battery connector (only available for 10KL)
5 5
13 14
12
10 7
8 8
9
6 1 2 3 4
11 5 5
13 14
12
10 7
8 8
9
6 1 2 3 4
11
PRO83110L PRO83110S
Options
• AS-400 Card for external alarm signal.
• SNMP Card for data communication via network connection
• MODBUS Card for communication
• Output Isolation Transformer
For 15K & 20K model For 10K model
For 15KVA to 20KVA model
1. RS-232 communication port 2. USB communication port
3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot
7. Charger fan 8. Power stage fan
9. Maintenance by-pass switch 10. Input circuit breaker
11. Output circuit breaker for receptacles
12. Output receptacles: connect to mission-critical loads 13. Input/Output terminal
14. External battery connector (only available for 10KL) 15. Output terminal 1
16. Output terminal 2
17. External battery terminal (only available for Long-run model) 18. Utility input terminal
19. Non-isolated Neutral terminal (only available for parallel system) 20. Grounding terminal (only available for parallel system)
5 5
13
19 10 7
8 7 8
9 1 2 3 4 6
20 5 5
13 10
7
8 7 8
9
6 1 2 3 4
15 16 18
19 15 16 17 18
19 20 PRO83115L
PRO83120L PRO83115S PRO83120S
Full Specifications
50 or 60Hz 300Vac < Vin < 480Vac 360/ 380/ 400/ 415VAC Nominal Voltage
Voltage Range Nominal Frequency Frequency Range Power Factor
45 ~ 64Hz
≧ 0.99
Capacity 10 KVA/ 8 KW 15 KVA/ 12 KW 20 KVA/ 16 KW
Valve regulated Lead Acid battery (Maintenance free batteries) Type
Capacity Liner Load Non-Liner Load
Recharge Time (Typical) Charging Current Standard Model
Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI62040-2; EN62040-3 Regulations
INPUT
MODELS PRO83110S/ L PRO83115S/ L PRO83120S/ L
OUTPUT
BATTERY
MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD
INDICATORS EFFICIENCY
Support Windows® 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB
1 sec
>130%
100% < Load < 110%
LCD Display AC Mode
±1%
0.8 Static Regulation
Frequency Range Frequency
Power Factor Current Crest Ratio
Voltage Distortion ≦ 2% THD
≦ 6% THD ≦ 5% THD ≦ 7% THD
Waveform
1.0 A (max) 2.0 A (max)
4.0 A (max) 8.0 A (max)
46 ~ 54 Hz or 56 ~ 64 Hz 50Hz or 60Hz auto selection or selectable
Pure Sinewave
9AH
9 hours recover to 90% capacity Up to 89%
3:1
Type Long-Run Model Capacity
Charging Current
10 mins
100% < Load < 130% 1 min
Depending on the application Depending on the application 200/ 208/ 220/ 230/ 240VAC Output Voltage
592 ×250 × 576
164
37 815 × 250 × 826
592 × 250 × 826
IP20
<95% non-condensing Operation Humidity
Protection
Ambient Temperature 0°C - +40°C
Noise Level
592 x 250 x 576 83
28
≤60dBA @ 1 Meter
≤58dBA @ 1 Meter Dimension (mm) D x W × H
Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) Standard Model
Long-Run Model
L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Specification for Online UPS with Isolation Transformer to be provided upon request.
Symbols: “/” meant for OR; “×” meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.
Online Master Series 10kVA – 20kVA
Master Series (3P/1P) - Rack Mount
Master Series (3P/1P) - Rack mount is a true on-line double-conversion technology three-phase input / single-phase outputUPS system with 3U to 6U universal-mount case. It is designed to ensure maximum protection and power quality for any type of load, especially for mission critical applications such as data center systems, security systems and telecommunications. It is available from 10kVA and 20kVA capacities with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes.
Master Series (3P/1P) - Rack mount with IGBT technology, it provides generator compatible where handles frequency variations and other power fluctuations that occur during generator operation. Internal bypass to assure continuous power to critical devices during UPS maintenance and parallel redundancy which will back up the load in the event of critical component failure is available.
• True double-conversion
• DSP technology guarantees high performance
• Output Power Factor 0.8
• Wide input voltage range
• Active power factor correction in all phases
• 50Hz/60Hz frequency converter mode
• Eco mode operation for energy saving (ECO)
• Emergency power off function (EPO)
• Generator compatible
• SNMP+USB+RS-232 multiple communications
• Adjustable battery numbers
• Optional N+X parallel redundancy
Rear Panel
PRO83120RS/ RL PRO83110RS/ RL
Data
Centre 19” Rack
Mount Storage
PLCS Emergency Alarm Devices Local Area
Network (LAN)
Telecommunication Devices
For 10kVA to 20kVA model
1. RS-232 communication port 2. USB communication port
3. Emergency power off function connector (EPO connector) 4. Parallel port (only available for parallel model)
5. Intelligent slot 6. Fan
7. External maintenance by-pass switch connection 8. Input circuit breaker
9. Input/Output terminal 10. Output terminal 11. Battery terminal 12. Input terminal
PRO83120RS/ RL PRO83110RS/ RL 5
12 10
7 8
9
6 6
1 2 3
4 4 4
11
5
12
10
7
8 9
6 6
6 6
1 2 3 4 4 11 4
Options
• AS-400 Card for external alarm signal.
• SNMP Card for data communication via network connection
• MODBUS Card for communication
• Universal Rackmount Slider for installation in rack cabinets
• External Maintenance Bypass Switch (10kVA only)
Full Specifications
50 or 60Hz 300Vac <Vin <480Vac 360/ 380 /400/ 415VAC Nominal Voltage
Voltage Range Nominal Frequency Frequency Range Power Factor
46 ~ 64Hz
≧ 0.99
Capacity 10kVA/ 8kW 20kVA/ 16kW
Valve regulated Lead Acid battery (Maintenance free batteries) Type
Capacity
Recharge Time (Typical) Charging Current Standard Model
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations
INPUT
MODELS PRO83110RS/ RL PRO83120RS/ RL
OUTPUT
BATTERY
MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD
INDICATORS EFFICIENCY
Support Windows® 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232
1.0 sec
>130%
100% < Load < 110%
LCD Display AC Mode
±1%
0.8 Static Regulation
Frequency Range Frequency
Power Factor Current Crest Ratio
Voltage Distortion Linear Load
Non-Linear Load ≦ 5% THD
≦ 2% THD
Waveform
1.0 A (max) 2.0A (max)
46 ~ 54Hz or 56 ~ 64Hz 50Hz or 60Hz auto selection or selectable
Pure Sinewave
9AH
9 hours recover to 90% capacity Up to 89%
3:1
Type Long-Run Model Capacity
Charging Current
10 mins
100% < Load < 130% 1 min
Depending on the application 4.0 A (max) Depending on the application
200/ 208/ 220/ 230/ 240VAC Output Voltage
668 x 438 x 133 (3U)
UPS Unit: 668 x 438 x 266 (6U) BatteryPack: 580 x 438 x 133 (3U) x 2
668 x 438 x 266 (6U)
<95% non-condensing 0°C - +40°C Operation Humidity
IP20 Protection
Ambient Temperature
≤58dBA @ 1 Meter ≤60dBA @ 1 Meter
Noise Level
UPS Unit: 668 x 438 x 133 (3U) Battery Pack: 580 x 438 x 133 (3U)
UPS Unit: 23
Battery Pack: 63 UPS Unit: 23
Battery Pack: 63 x 2
23 38
Dimension (mm) D x W × H
Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) Standard Model
Long-Run Model
L means Long-run model; S means Standard model.
Symbols: “/” meant for OR; “×” meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.
Online Master Series 10kVA – 20kVA
Master Series (3P/3P) - Tower
Master Series (3P/3P) - Tower is a true on-line double-conversion technology three-phase input/ three-phase output UPS system, it is an ideal for protection and power quality for small server room, medical devices, industrial processes and telecommunications facilities. It is available from 10kVA to 20kVA capacities with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes.
Master Series (3P/3P) - Tower with IGBT technology, it provides generator compatible where handles frequency variations and other power fluctuations that occur during generator operation. Internal bypass to assure continuous power to critical devices during UPS maintenance and parallel redundancy which will back up the load in the event of critical component failure is available. An optional of isolation transformer can be attached to UPS unit without taking extra space.
• True double-conversion
• DSP technology guarantees high performance
• Wide input voltage range
• Active power factor correction in all phases
• 50Hz/60Hz frequency converter mode
• Eco mode operation for energy saving (ECO)
• Accepts dual power inputs
• Emergency power off function (EPO)
• Generator compatible
• SNMP+USB+RS-232 multiple communications
• Maintenance bypass available
• Optional N+X parallel redundancy
• Optional isolation transformer offers full isolation and complete common mode noise
Rear Panel
For 10kVA to 20kVA model
1. RS-232 communication port 2. USB communication port
3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot
7. Charger fan 8. Power stage fan
9. Maintenance bypass switch
10. Bypass Input Circuit Breaker (Only available for dual input unit) 11. Input circuit breaker
12. Input/Output terminal 13. Output terminal
14. External battery terminal (only available for Long-run model) 15. Bypass input terminal (Only available for dual input) 16. Input terminal
PRO83310S/L PRO83320S/L
CentreData Electro-Medical
Device Storage
PLCS Emergency Alarm Devices
E-Business (Server Farms,
ISP/ASP/POP) Local Area
Network (LAN)
Telecommunication Devices
5
13 16 1512 10 14
7
7 6 8
8
9 1 2 3 4
11
PRO83310S/L PRO83320S/L