• No results found

UNINTERRUPTIBLE POWER SUPPLY (UPS)

N/A
N/A
Protected

Academic year: 2021

Share "UNINTERRUPTIBLE POWER SUPPLY (UPS)"

Copied!
48
0
0

Loading.... (view fulltext now)

Full text

(1)

CATALOGUE

Revision 2012

UNINTERRUPTIBLE

POWER SUPPLY (UPS)

Protecting Your Data

(2)
(3)

Table of Contents

About Us - Company Profile

Online UPS

Professional Series (1P/1P) - Tower Master Series (1P/1P) - Tower Master Series (1P/1P) - Combo

Master Series (1P/1P) - 2-in-1 Rack/ Tower Master Series (3P/1P) - Tower

Master Series (3P/1P) - Rack Mount Master Series (3P/3P) - Tower Power Series (3P/3P)

Line Interactive UPS PRO Series

Inverter UPS IPS Series

Solar UPS

PDC Series - DC UPS PCC Series

PSI Hybrid Series PSI On-Grid Series PSI Off-Grid Series PSS Series

Software & Accessories Appendixz

2

4 4 6 10 12 16 18 21 23

27 27

28 28

31 31 32 33 34 35 36 37 41

(4)

Our Mission

Accentuate The Best For The E-generation

PROLiNK® aspires to accentuate the best for the e-generation. With technology becoming an essential aspect of modern living, the e-generation concept has gradually become ingrained in our lives and digital literacy is becoming more and more commonplace.

PROLiNK products are designed to make technology work for the e-generation. Created with the end-user in mind, our products are crafted to enhance performance whether you are at work or play – our products work harder, while you work smarter to achieve your desired results with less effort and better efficiency.

Providing value to our consumers – whether home or business users, remains a firm commitment of PROLiNK. With its wide range of quality products, PROLiNK makes it easy for home users to find user-friendly yet affordable solutions for their technological needs, while business users are assured of reliable and secure solutions for their network infrastructure.

Our Vision

Ideas, Innovation and Information

PROLiNK® aims to be the key driving force behind technological changes and improvements in both developing and developed countries. With its strong focus on technology, our team sets high standards for itself in the areas of innovation, change and improvement so as to provide the next generation of users with products that are suitable for their technology advanced environments.

The small “i” in PROLiNK represents ideas, innovation and information – three key pillars of growth that drive us towards achieving excellence in our field of expertise and challenges us to think beyond our usual boundaries.

Fida International (S) Pte Ltd has been a provider of technologically innovative and user-friendly products manufac- tured under the brand name “PROLiNK®” since 1991. With more than two decades of professional experience in the information communications sector, PROLiNK is now renowned as a specialist in its field, especially in area of Backup UPS products.

Over the years, PROLiNK has built its presence through a strong foundation of technological leadership within the South Asian, South-east Asian and Middle Eastern regions and is continuing to build its presence worldwide. With its current network of sales offices in more than 20 countries, customers can be assured that PROLiNK is able to provide the right solutions to meet the needs of both home and business users within each geographical location both efficiently and effectively.

The company’s quest for continuous improvement and quality assurance to its customers has earned us the ISO9001 quality certification since 1999. With its consistently strong commitment to quality, customers can be assured of they are getting true value - superior quality products at affordable prices.

(5)

Core Values

Secured Information Management

With more than two decades of professional experience in providing backup power solutions to our customers, we are able to support our customers with superior technological know-how and expertise, as well as advice on market trends. At the same time, we are also fully committed to protecting the privacy of our customers and to manage confidential information discreetly.

Innovative Design

Our products are carefully thought out to ensure that each item is designed to meet the needs of our customers. With the team’s solid experience in the UPS market, customers can be certain that our designs are innovative yet functional, and suitable for each dynamic market that we have a presence in.

Superior Service Standards

Strict and rigorous testing makes up a huge part of our quality control procedures. We ensure that every item meets our strict standards – from the individual components to the actual finished product.

Total Quality Assurance System

Our products go through careful planning and checks at every stage of the production cycle - from the beginning stages of product design to the manufacturing and finally the actual delivery of the goods. This guarantees that our customers receive only the best quality goods – of high reliability and durability. Our total quality system has been audited and approved by globally recognized bodies.

Range of UPS

The wide range of our products gives you an infinite range of solutions:

1. Online UPS

2. Line Interactive UPS 3. Inverter UPS 4. Solar UPS

(6)

Online Professional Series 1KVA – 6KVA

Work-Stations Service

Rear Panel

PRO901S/

PRO902S PRO901L/

PRO902L PRO903S/

PRO906S PRO903L/

PRO906L

Professional Series (1P/1P) - Tower

The Professional Series (1P/1P) - Tower is an advanced, affordable on-line double-conversion technology single-phase UPS system. Professional Series is available with 1000VA to 6000VA models and these offer high reliability for workstations, server and network equipment.

The Professional Series is designed to protect against power outages, disturbances and spikes. It also provides high-efficient charger with PFC. High battery charging current and battery extension assembly is available for the long run time application. In order to supply pure and clean power to sensitive devices, an optional of isolation transformer can be attached to UPS unit without taking extra space.

• True Double-Conversion Online UPS

• Wide input voltage range (110~300VAC)

• Input Power Factor correction 0.98

• Output Power Factor 0.80

• Generator compatible

• LCD User Interface

• RS-232 communication port or mini slot for USB / RS-232 / AS400 / SNMP communication

• Smart battery charger design for optimized battery performance

• Optional isolation transformer available

Local Area Network (LAN)

PRO901S/ L

PRO902S/ L PRO903S/ L PRO906S/ L

5 6

9 4 3

2 1

5 6

9 4 3

2 1

5

9

3 2

7 1 8 4 6

5

9

3 2

7 1 8 4

6

For 1KVA to 6KVA model

1. Output receptacles 2. AC input

3. Input circuit breaker

4. Network/Fax Modem Surge Protection 5. RS-232 communication port /

SNMP intelligent slot 6. External battery connection (only available for L model) 7. Output terminal

8. Output circuit breaker 9. Fan

Small Computer Network

(7)

Full Specifications Options

• RS-232 Port for communication.

• AS-400 Card for external alarm signal.

• SNMP Card for data communication via network connection.

• Output Isolation Transformer.

• External PDU & Maintenance Bypass Switch. (suitable for UPS up to 3KVA only)

50 or 60Hz

110Vac < Vin < 290Vac @ 50% LOAD/ 168Vac < Vin < 300Vac @ 100% LOAD 208/ 220/ 230/ 240VAC

Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor

40 ~ 70Hz

≧ 0.98

6000 VA/ 4800 W

Capacity 1000 VA/ 800 W 2000 VA/ 1600 W 3000 VA/ 2400 W

Valve regulated Lead Acid battery (Maintenance free batteries) Type

Capacity Liner Load Non-Liner Load

Recharge Time (Typical) Charging Current Standard Model

Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions

Safety: EN62040-1-1; EMI62040-2; EN62040-3 Regulations

INPUT

MODELS PRO901S/ L PRO902S/ L PRO903S/ L PRO906S/ L

OUTPUT

BATTERY

MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD

INDICATORS EFFICIENCY

Support Windows® 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB

1.5 sec

>130%

100% < Load < 110%

LCD Display AC Mode

±1% ±3%

0.8 Static Regulation

Frequency Range Frequency

Power Factor Current Crest Ratio

Voltage Distortion ≦ 3% THD

≦ 6% THD ≦ 7% THD

≦ 4% THD

Waveform

1.0 A (max) 47 ~ 53 Hz or 57 ~ 63 Hz 50Hz or 60Hz auto selection

Pure Sinewave

9AH

4 hours recover to 90% capacity Up to 88%

3:1

10AH

Type Long-Run Model Capacity

Charging Current 4.0 A or 8.0 A (max)

Overload warning only (No shutdown)

100% < Load < 130% 30 sec

Depending on the application Depending on the application 200/ 208/ 220/ 230/ 240VAC Output Voltage

397×145×220 17.2

8.9

421 × 190 × 318

421×190×318 28

13.5

426 × 190 × 318

426×190×318 35.3

14.3

<90% non-condensing 0°C - +40°C Operation Humidity

Ambient Temperature

≤ 45dBA @ 1 Meter Noise Level

397 x 145 x 220 9.3

4.8 Dimension (mm) D x W × H

Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) Standard Model

Long-Run Model

L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).

Specification for Online UPS with Isolation Transformer to be provided upon request.

Symbols: “/” meant for OR; “×” meant for Multiply of.

All specifications, designs and contents are subjected to changes without prior notice.

(8)

Online Master Series 1KVA – 10KVA

Work-Stations Service

Rear Panel

Master Series (1P/1P) - Tower

Master Series (1P/1P) - Tower is a true on-line double-conversion technology single-phase UPS system which provides clean, high level quality power for critical devices such as small computer centers, servers, telecom applications and industrial applications. It is available from 1KVA to 10KVA capacities with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes.

Master Series (1P/1P) - Tower is designed with a smart battery charger to optimize battery performance. High battery charging current and battery extension assembly is available for long run applications. Internal bypass to assure continuous power to critical devices during UPS maintenance and parallel redundancy which will back up the load in the event of critical component failure is available for the 6KVA and 10KVA models. An optional of isolation transformer can be attached to UPS unit without taking extra space.

• True Double-Conversion Online UPS

• Wide input voltage range (110~300VAC)

• Input Power Factor correction 0.99

• Output Power Factor 0.80

• Generator compatible

• LCD User Interface

• RS-232 communication port or mini slot for USB/ RS-232/

AS400/ SNMP communication

• Smart battery charger design for optimized battery performance

• Optional isolation transformer available

Local Area Network (LAN)

PRO802S/ L PRO803S/ L PRO801S/ L

PRO8015S/ L PRO806S/ L PRO810S/ L

For 1KVA to 3KVA model

1. Programmable outlets: connect to non- critical loads

2. Output receptacles: connect to mission- critical loads

3. AC input

4. Input circuit breaker

5. Network/Fax/Modem surge protection 6. Emergency power off function connector (EPO)

7. USB communication port 8. RS-232 communication port 9. SNMP intelligent slot

10. External battery connection (only available for L model)

11. Output terminal 12. Output circuit breaker 13. Fan

Small Computer Network

PRO802S/

PRO803S PRO802L/

PRO803L PRO801S/

PRO8015S PRO801L/

PRO8015L 6 85 9

7

13 4

3 2

1

9 6 85 7

13 10

4

3 2

1

9 5 13

13 2 1

7 8

6

4 3

95

2 1

7 8

6

4 3 13 10

13

(9)

Battery Pack

For 1KVA to 3KVA model

For 6KVA to 10KVA model

1. RS-232 communication port 2. USB communication port

3. Emergency power off function connector (EPO connector)

4. Share current port (only available for parallel model)

5. Parallel port (only available for parallel model) 6. Intelligent slot

7. Charger fan 8. Power stage fan

9. Maintenance bypass switch 10. Input circuit breaker 11. Input/Output terminal 12. Output terminal 1 13. Output terminal 2

14. External battery terminal (only available for Long-run model)

15. Utility input terminal 16. Output IEC Socket

9

5 5 2

1

8 7

8

6 4 3

15 12 13

16 11

10

9

5 5 2

1

8 7

8

6 4 3

15 12 13

14

16 11

10

For 6KVA to 10KVA model

PRO806S/

PRO810S PRO806L/

PRO810L

Capacity Battery Type Battery Number Dimension (DxWxH) Weight (kg)

1KVA/ 1.5KVA

6 pcs

18

6 pcs 397×145×220

20

12 pcs

36

2KVA/ 3KVA

12 pcs 18 pcs 18 pcs

421×190×318

40 55

12V9AH

12V7AH 12V7AH 12V9AH 12V7AH 12V9AH

535×190×318 61

Capacity Battery Type Battery Number Dimension (DxWxH) Weight (kg)

20 pcs

64

20 pcs 592×250×576

72

40 pcs

109

6KVA/ 10KVA

40 pcs 60 pcs 60 pcs

592×250×576

125 166

12V9AH

12V7AH 12V7AH 12V9AH 12V7AH 12V9AH

830×250×576 190

(10)

Full Specifications Options

• AS-400 Card for external alarm signal.

• SNMP Card for data communication via network connection.

• Output Isolation Transformer.

• External PDU & Maintenance Bypass Switch. (suitable for UPS up to 3KVA only)

50 or 60Hz

110Vac <Vin<290Vac @ 50% LOAD / 175Vac <Vin<300Vac @ 100% LOAD 208/ 220/ 230/ 240VAC

Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor

40 ~ 70Hz

≧ 0.99

3000 VA/ 2400 W

Capacity 1000 VA/ 800 W 1500 VA/ 1200 W 2000 VA/ 1600 W

Valve regulated Lead Acid battery (Maintenance free batteries) Type

Capacity

Recharge Time (Typical) Charging Current Standard Model

Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions

Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations

INPUT

MODELS PRO803S/ L

6000 VA/ 4800 W PRO806S/ L

10000 VA/ 8000 W PRO810S/ L PRO801S/ L PRO8015S/ L PRO802S/ L

OUTPUT

BATTERY

MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD

INDICATORS EFFICIENCY

Support Windows® 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232

2.0 sec

>130%

100% < Load < 110%

LCD Display AC Mode

±1%

0.8 Static Regulation

Frequency Range Frequency

Power Factor Current Crest Ratio

Voltage Distortion Linear Load Non-Linear Load

≦ 3% THD ≦ 3% THD

≦ 6% THD ≦ 7% THD ≦ 6% THD

≦ 4% THD

Waveform

1.0 A (max) 47 ~ 53Hz or 57 ~ 63Hz 50Hz or 60Hz auto selection or selectable

Pure Sinewave

9AH 7AH 9AH 7AH

7AH

4 hours recover to 90% capacity 9 hours recover to 90% capacity Up to 89%

3:1

9AH

Type Long-Run Model Capacity

Charging Current 8.0 A (max) 4.0 A (max)

Overload warning only (No shutdown)

100% < Load < 130% 30 sec

Depending on the application Depending on the application 200/ 208/ 220/ 230/ 240VAC Output Voltage

397×145×220

26 28

13

421 × 190 × 318

421×190×318

81

13

592 x 250 x 576

592 x 250 x 576 83

25 27

<90% non-condensing 0°C - +40°C Operation Humidity

Ambient Temperature

≤45dBA @ 1 Meter ≤55dBA @ 1 Meter ≤58dBA @ 1 Meter

Noise Level

397 x 145 x 220

13 14

7 7

Dimension (mm) D x W × H Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) Standard Model

Long-Run Model

Derate to 60% of capacity in Frequency converter mode and to 80% when the output valtage is adjusted to 208VAC.

If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.

L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).

Specification for Online UPS with Isolation Transformer to be provided upon request.

Symbols: “/” meant for OR; “×” meant for Multiply of.

All specifications, designs and contents are subjected to changes without prior notice.

(11)

Programmable Outlets (P1) - connect to non-critical devices

True double-conversion Online UPS

A true double conversion UPS will provide clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer centers, servers, telecom applications, as well as for industrial applications.

Higher Accuracy For Output Voltage

With advanced control firmware, Master Series (1P/1P) provides high accuracy within +/- 1% for output voltage.

It can be applied to precious test & IT equipment.

Smart Battery Charger Design To Optimize Battery Performance

• Master Series (1P/1P) 1-3KVA is equipped with 2-stage charger design to guarantee battery discharge time.

Besides, it will adjust charging voltage according to outside temperature. This features will extend the useful service life of batteries.

• Master Series (1P/1P) 6KVA and above models are equipped with 3-stage extendable charger for optimized battery performance. This feature extends the useful service life of batteries and optimizes battery recharge time. Besides, the extendable charger design can be stacked in numbers for large-capacity battery charging.

DSP Technology Applied For 6KVA And Above Models

A DSP controller provides an improved and cost-effective solution with high performance.

Maintenance Bypass Available For 6KVA And Above Models

Internal bypass assures continuous power to critical devices during UPS maintenance.

Optional Hot Standby Mode And N+X Parallel Redundancy Available For 6KVA And Above Models

For genuinely redundant power protection, Master Series (1P/1P) (6KVA and above models) can either be used in parallel operation with up to 3 units or hot standby mode. Slave UPS will back up the load in the event of critical component failure. It increases power safety and availability.

Adjustable Battery Numbers For 6KVA And Above Models

Master Series (1P/1P) (6KVA and above models) can still normal operate well with only 18 or 19 internal batteries.

Built-in Isolation Transformer (Option)

With built-in isolation transformer, the UPS will offer full isolation and complete common mode noise rejection for connected precious equipment. It become an ideal power source with 100% protection against unexpected AC power problems.

Output Power Factor 0.8

Compared to the online UPSs in the current market, Master Series (1P/1P) provides better output power factor up to 0.8. It offers higher performance and efficiency for critical applications.

Wide Input Voltage Range (110 V -300 V)

Master Series (1P/1P) can still provide stable power to connected devices under unstable power environments.

50/60 Hz Frequency Converter Mode

Lock output frequency at 50Hz or 60Hz to suit power sensitive equipments.

ECO Mode Operation For Energy Saving

Offers efficiency as high as 97% to cut energy usage &

cost. UPS power application via static bypass, timely returning to online double conversion when the need arises.

Emergency Power Off (EPO) Function

This feature can secure the personnel and equipment in case of fires or other emergencies.

SNMP + USB + RS-232 Multiple Communications For 1-3KVA Models

This feature allows either USB or RS-232 communication port to work with SNMP interface simultaneously.

Programmable Power Management Outlets

With programmable power management outlets, users can easily and indepenntly control load segments. During power failure, this feature enables users to extend battery time to missioncritical devices by shutting down the non-critical devices.

(12)

Online Master Series 6KVA – 10KVA

Work-Stations Service

Rear Panel

Master Series (1P/1P) - Combo

Master Series (1P/1P) - Combo is designed with a very small footprint size to solve the problem of limited space with the support of 6kVA and 10kVA UPS system. Master Series (1P/1P) – Combo used true on-line double-conversion technology single-phase UPS system which provides clean, high level quality power for critical devices such as small computer centres, servers & telecom applications.

Master Series (1P/1P) - Combo is available from 6KVA and 10KVA capacities with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes. Smart battery charger design to optimize battery performance and high battery charging current and battery extension assembly is available for long run applications.

• True double-conversion on line UPS

• DSP technology guarantees high performance

• Wide input voltage range (110-300 VAC)

• Active input power factor correction 0.99

• Output power factor 0.8

• 50Hz/60Hz frequency converter mode

• Standard backup UPS and long backup UPS in one integrated unit

• Adjustable battery number from 16 blocks to 20 blocks

• Adjustable charging current can be changed via LCD or software (1A~6A)

• Emergency power off function (EPO)

• USB and RS-232 communications port and mini slot for AS400/ SNMP communication.

• Maintenance bypass available

Local Area Network (LAN)

For 6KVA to 10KVA model

1. RS-232 communication port 2. USB communication port

3. Emergency power off function connector (EPO connector)

4. Intelligent slot 5. Power stage fan

6. Maintenance bypass switch 7. Input circuit breaker 8. Input/Output terminal

9. External battery terminal (only available for Long-run model)

10. Battery Compartment (only available for Standard model)

Small Computer Network

PRO806C/

PRO810C PRO806CL/

PRO810CL

PRO806CL/

PRO810CL

5 5

6 8 9

7 4 3 2 1

5 5

6 8

7 4 3 2 1

10

PRO806C/

PRO810C

(13)

Full Specifications Options

• AS-400 Card for external alarm signal.

• SNMP Card for data communication via network connection.

• Output Isolation Transformer.

50 or 60Hz

110Vac <Vin<290Vac @ 50% LOAD / 176Vac <Vin<300Vac @ 100% LOAD 208/ 220/ 230/ 240VAC

Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor

46 ~ 64Hz

≧ 0.99

Capacity 6000 VA/ 4800 W 10000 VA/ 8000 W

Valve regulated Lead Acid battery (Maintenance free batteries) Type

Capacity

Recharge Time (Typical) Charging Current Standard Model

Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions

Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations

INPUT

MODELS PRO806C/ CL PRO810C/ CL

OUTPUT

BATTERY

MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD

INDICATORS EFFICIENCY

Support Windows® 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232

1.0 sec

>130%

100% < Load < 110%

LCD Display AC Mode

±1%

0.8 Static Regulation

Frequency Range Frequency

Power Factor Current Crest Ratio

Voltage Distortion Linear Load

Non-Linear Load ≦ 5% THD

≦ 3% THD

Waveform

1.0 A (max) 46 ~ 54Hz or 56 ~ 64Hz 50Hz or 60Hz auto selection or selectable

Pure Sinewave

9AH

9 hours recover to 90% capacity Up to 90%

3:1

Type Long-Run Model Capacity

Charging Current 6.0 A (max)

10 mins

100% < Load < 130% 1 min

Depending on the application Depending on the application 200/ 208/ 220/ 230/ 240VAC Output Voltage

360 x 192 x 318

440 x 192 x 688

440 x 192 x 318

<95% non-condensing 0°C - +40°C Operation Humidity

Ambient Temperature

≤55dBA @ 1 Meter ≤58dBA @ 1 Meter

Noise Level

360 x 192 x 688

60 75

21 23

Dimension (mm) D x W × H Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) Standard Model

Long-Run Model

L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).

Specification for Online UPS with Isolation Transformer to be provided upon request.

Symbols: “/” meant for OR; “×” meant for Multiply of.

All specifications, designs and contents are subjected to changes without prior notice.

(14)

Online Master Series 1KVA – 10KVA

Work-Stations Service 19” Rack Mount

Master Series (1P/1P) - 2-in-1 Rack/ Tower

Master Series (1P/1P) – 2-in-1 Rack/Tower is a true on-line double-conversion technology single-phase UPS system with 2U universal-mount case. It can be easily installed as a floor-standing tower or with a 19-inch rackmount bracket.

The Master Series was designed with a high density output power factor of 0.9 to provide higher performance and efficiency to critical applications such as sensitive networks, small computer centers, servers and telecom applications. It is available in capacities from 1KVA to 10KVA with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes.

Master Series (1P/1P) - 2-in-1 Rack/Tower has been designed with a hot-swappable battery to ensure clean and uninterruptible power to protected equipment during battery replacement. A high battery charging current and battery extension assembly is available for long run applications. Parallel redundancy which will back up the load in the event of critical component failure is available for the 6kVA and 10kVA models. Front panel digital display can be easily adjusted through LCD setting to suit the installation format, whether it is left vertically standing or flat wall mounted.

• True Double-Conversion Online UPS

• Rack or Tower design

• Wide input voltage range (110~300VAC)

• Input Power Factor correction 0.99

• Output Power Factor 0.90

• 50/60Hz frequency converter mode

• Hot-Swappable battery design

• Emergency Power Off (EPO) function

• ECO Mode Operation for energy saving

• General Compatible

• Charger capacity expansion to 8A for long-run models

• SNMP+USB+RS232 multiple communications

• Smart battery charger design for optimized battery performance

• Selectable output voltage via LCD panel

Local Area Network (LAN) Small Computer

Network

PRO801RS to PRO803RS/

PRO801RL to PRO803RL

PRO806RS/ PRO810RS/

PRO806RL/ PRO810RL

PRO803RL

5 12 12 10

7

8 9 6 1 2

3

4 11

Rear Panel

For 1KVA to 3KVA model

1. Programmable outlets:Connect to non-critical loads 2. Output receptacles: Connect to mission-critical loads 3. AC input

4. Input circuit breaker

5. Network/Fax/Modem surge protection

6. Emergency power off function connector (EPO) 7. USB communication port

8. RS-232 communication port 9. SNMP intelligent slot

10. Battery Compartment (only available for Standard model) 11. Input terminal

12. Fan

PRO801RS/PRO8015RS/PRO802RS

5 12 6 10

7 8 9

1 2

3 4

PRO801RL/PRO8015RL/PRO802RL

5 12 6 10

7 8 9

1 2

3 4

PRO803RS

5 12 12 10

7

8 9 6 1 2

3 4 11

(15)

Options

• AS-400 Card for external alarm signal.

• SNMP Card for data communication via network connection

• MODBUS Card for communication

• Universal Rackmount Slider for installation in rack cabinets

• External PDU & Maintenance Bypass Switch (suitable for UPS up to 3KVA only)

• Maintenance Bypass Switch [MBS] (for UPS 6 to 10KVA only)

• External Automatic Transfer Switch (ATS)

PRO806RS/RL PRO810RS/RL

9 6 4

7 7

12

10 14

13

11 16 15

Battery Pack

For 1KVA to 10KVA model

Capacity Battery Type Battery Number Dimension (DxWxH) Weight (kg)

1KVA 1.5KVA 2KVA

8 pcs

31.1

6 pcs 480×438×88

29.1

8 pcs

31.1

3KVA 6KVA 10KVA

12 pcs 20 pcs

43.3 57

12V9AH 12V7AH 12V9AH

580×438×133 600×438×88

63

For 6KVA to 10KVA model

1. Programmable outlets:Connect to non-critical loads 2. Output receptacles: Connect to mission-critical loads 3. AC input

4. Input circuit breaker

5. Network/Fax/Modem surge protection

6. Emergency power off function connector (EPO) 7. USB communication port

8. RS-232 communication port 9. SNMP intelligent slot

10. Battery Compartment (only available for Standard model) 11. Input terminal

12. Fan

13. Parallel port (only available for parallel model) 14. External maintenance by-pass switch connection 15. Output Terminal

16. Ground

MBS-rack-UK Schuko IEC NEMA ATS-R MBS - 6 to 10K

(16)

Full Specifications

50 or 60Hz

120Vac <Vin<290Vac @ 50% LOAD / 170Vac <Vin<300Vac @ 100% LOAD 208/ 220/ 230/ 240VAC

Nominal Voltage Voltage Range Nominal Frequency Frequency Range Power Factor

40 ~ 70Hz

≧ 0.99 3000 VA Capacity Active Power (Standard Model)

Active Power (Long-Run Model)

Apparent Power 1000 VA 1500 VA 2000 VA

Valve regulated Lead Acid battery (Maintenance free batteries) Type

Capacity

Recharge Time (Typical) Charging Current Standard Model

Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions

Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations

INPUT

MODELS PRO803RS/ RL

6000 VA PRO806RS/ RL

10000 VA 2700 VA

900 VA 1350 VA 1800 VA 5400 VA 9000 VA

2400 VA

800 VA 1200 VA 1600 VA 4800 VA 8000 VA

PRO810RS/ RL PRO801RS/ RL PRO8015RS/ RL PRO802RS/ RL

OUTPUT

BATTERY

MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD

INDICATORS EFFICIENCY

Support Windows® 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232

2.0 sec 1 sec

>130%

100% < Load < 110%

LCD Display AC Mode

±1%

0.9 @ Standard Model, 0.8 @ Long-Run Model Static Regulation

Frequency Range Frequency

Power Factor Current Crest Ratio

Voltage Distortion Linear Load

Non-Linear Load ≦ 8% THD ≦ 6% THD ≦ 4% THD

≦ 2% THD

Waveform

1.0 A (max) 47 ~ 53Hz or 57 ~ 63Hz 50Hz or 60Hz auto selection or selectable

Pure Sinewave

9AH 7AH

4 hours recover to 90% capacity 9 hours recover to 90% capacity Up to 90%

3:1

5:1 5:1 3:1

9AH

Type Long-Run Model Capacity

Charging Current 4.0 A or 8.0 A (max) 4.0 A (max) 4.0 A (max)

Overload warning only (No shutdown) 10 mins

100% < Load < 130% 30 sec 1 min

Depending on the application Depending on the application 200/ 208/ 220/ 230/ 240VAC Output Voltage

380x438x88 (2U) 480x438x88 (2U)

20.6 28

11.3 480x438x88 (2U)

600x43x88(2U)

UPS Unit: 17

Battery Pack: 57 UPS Unit: 20 Battery Pack: 63

13.8

Battery Unit:

580x438x133 (3U) UPS Unit:

580x438x133 (3U)

Battery Unit:

580x438x133 (3U) UPS Unit:

688x438x133 (3U) 600x438x88 (2U)

580x438x133 (3U) 668x438x133 (3U)

17 20

<90% non-condensing 0°C - +40°C Operation Humidity

Ambient Temperature

≤50dBA @ 1 Meter Noise Level

380x438x88 (2U)

12.9 17.6

8.6 10.7

Dimension (mm) D x W × H

Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) Standard Model

Long-Run Model

L means Long-run model; S means Standard model.

Symbols: “/” meant for OR; “×” meant for Multiply of.

All specifications, designs and contents are subjected to changes without prior notice.

(17)

Programmable Outlets (P1) - connect to non-critical devices

True Double-conversion Online UPS

A true double conversion UPS will provide clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer centers, servers, telecom applications, as well as for industrial applications.

Programmable Power Management Outlets

With programmable power management outlets, users can easily and independently control load segments.

During power failure, this feature enables users to extend battery time to mission critical devices by shutting down the non-critical devices.

ECO And Advanced ECO Mode For Energy Saving

It allows UPS to operate in high efficiency up to 97%in energy saving ECO mode and even up to 98%. In this operation mode, load is supplied by the mains. In the event of a mains failure, the inverter takes over the load and provides supply continuity to the connected systems.

Emergency Power Off Function (EPO)

This feature can secure the personnel and equipment in case of fires or other emergencies.

Hot-swappable Battery Design

This design ensures clean and uninterruptible power to protected equipment during battery replacement.

Long-run Models Available

To provide longer backup time, we also offer long-run models. If additional runtime is required, matching external battery units is available.

User-friendly And Easy-shift LCD Display

The front panel digital display can be easily shifted through LCD setting to suit the installation format, verti- cally stand or flat wall mount.

Rack/ Tower Design

Master (1P/1P) - 2-in-1 Rack/Tower Series is designed in true 2U universal-mount case. It can be easily installed as floor-standing tower or in 19-inch rack- mount bracket.

Higher Output Crest Radio Perfect For Generator And Compressor

Compared to general online UPS, Master (1P/1P) - 2-in-1 Rack/Tower Series provide higher current crest ratio as 5:1. It can support not only precious IT equipment, but also compressors and motor-type devices.

Output Voltage Regulation < 1%

Master (1P/1P) - 2-in-1 Rack/ Tower Series offers better output voltage regulation (+/-1%), which ensures higher compatibility with even the most sensitive power supplies.

Output power factor 0.9

Master (1P/1P) - 2-in-1 Rack/Tower Series is a high- density UPS with output power factor 0.9 to provide higher performance and efficiency to critical applications.

Rack Display Tower Display

19” Rack-mounting Floor-standing Tower

(18)

Online Master Series 10KVA – 20KVA

Master Series (3P/1P) - Tower

Master Series (3P/1P) - Tower is a true on-line double-conversion technology three-phase input / single-phase output UPS system which ensure maximum protection and power quality for any type of load, especially for mission critical applications such as data center systems, security systems, industrial processes and telecommunications. It is available from 10KVA to 20KVA capacities with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes.

Master Series (3P/1P) - Tower with built in phase auto adapt function simplifies wire installation and single phase input is acceptable. With IGBT technology, it provides generator compatible where handles frequency variations and other power fluctuations that occur during generator operation. Internal bypass to assure continuous power to critical devices during UPS maintenance and parallel redundancy which will back up the load in the event of critical component failure is available. An optional of isolation transformer can be attached to UPS unit without taking extra space.

• True Double-Conversion Online UPS

• DSP technology guarantees high performance

• Output Power Factor 0.80

• Input Power Factor Correction 0.99

• Wide input voltage range

• Active power factor correction in all phases

• 50/60Hz frequency converter mode

• Emergency Power Off (EPO) function

• SNMP+USB+RS232 multiple communications

• Adjustable battery numbers

• Maintenance bypass available

• Optional N+X parallel redundancy

• Optional isolation transformer available

Rear Panel

PRO83110S/L PRO83115L/

PRO83120L

PRO83115S/

PRO83120S

CentreData Electro-Medical

Device Storage

PLCS Emergency Alarm Devices

E-Business (Server Farms,

ISP/ASP/POP) Local Area

Network (LAN)

Telecommunication Devices

For 10KVA model

1. RS-232 communication port 2. USB communication port

3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot

7. Charger fan 8. Power stage fan

9. Maintenance by-pass switch 10. Input circuit breaker

11. Output circuit breaker for receptacles

12. Output receptacles: connect to mission-critical loads 13. Input/Output terminal

14. External battery connector (only available for 10KL)

5 5

13 14

12

10 7

8 8

9

6 1 2 3 4

11 5 5

13 14

12

10 7

8 8

9

6 1 2 3 4

11

PRO83110L PRO83110S

(19)

Options

• AS-400 Card for external alarm signal.

• SNMP Card for data communication via network connection

• MODBUS Card for communication

• Output Isolation Transformer

For 15K & 20K model For 10K model

For 15KVA to 20KVA model

1. RS-232 communication port 2. USB communication port

3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot

7. Charger fan 8. Power stage fan

9. Maintenance by-pass switch 10. Input circuit breaker

11. Output circuit breaker for receptacles

12. Output receptacles: connect to mission-critical loads 13. Input/Output terminal

14. External battery connector (only available for 10KL) 15. Output terminal 1

16. Output terminal 2

17. External battery terminal (only available for Long-run model) 18. Utility input terminal

19. Non-isolated Neutral terminal (only available for parallel system) 20. Grounding terminal (only available for parallel system)

5 5

13

19 10 7

8 7 8

9 1 2 3 4 6

20 5 5

13 10

7

8 7 8

9

6 1 2 3 4

15 16 18

19 15 16 17 18

19 20 PRO83115L

PRO83120L PRO83115S PRO83120S

(20)

Full Specifications

50 or 60Hz 300Vac < Vin < 480Vac 360/ 380/ 400/ 415VAC Nominal Voltage

Voltage Range Nominal Frequency Frequency Range Power Factor

45 ~ 64Hz

≧ 0.99

Capacity 10 KVA/ 8 KW 15 KVA/ 12 KW 20 KVA/ 16 KW

Valve regulated Lead Acid battery (Maintenance free batteries) Type

Capacity Liner Load Non-Liner Load

Recharge Time (Typical) Charging Current Standard Model

Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions

Safety: EN62040-1-1; EMI62040-2; EN62040-3 Regulations

INPUT

MODELS PRO83110S/ L PRO83115S/ L PRO83120S/ L

OUTPUT

BATTERY

MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD

INDICATORS EFFICIENCY

Support Windows® 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB

1 sec

>130%

100% < Load < 110%

LCD Display AC Mode

±1%

0.8 Static Regulation

Frequency Range Frequency

Power Factor Current Crest Ratio

Voltage Distortion ≦ 2% THD

≦ 6% THD ≦ 5% THD ≦ 7% THD

Waveform

1.0 A (max) 2.0 A (max)

4.0 A (max) 8.0 A (max)

46 ~ 54 Hz or 56 ~ 64 Hz 50Hz or 60Hz auto selection or selectable

Pure Sinewave

9AH

9 hours recover to 90% capacity Up to 89%

3:1

Type Long-Run Model Capacity

Charging Current

10 mins

100% < Load < 130% 1 min

Depending on the application Depending on the application 200/ 208/ 220/ 230/ 240VAC Output Voltage

592 ×250 × 576

164

37 815 × 250 × 826

592 × 250 × 826

IP20

<95% non-condensing Operation Humidity

Protection

Ambient Temperature 0°C - +40°C

Noise Level

592 x 250 x 576 83

28

≤60dBA @ 1 Meter

≤58dBA @ 1 Meter Dimension (mm) D x W × H

Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) Standard Model

Long-Run Model

L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).

Specification for Online UPS with Isolation Transformer to be provided upon request.

Symbols: “/” meant for OR; “×” meant for Multiply of.

All specifications, designs and contents are subjected to changes without prior notice.

(21)

Online Master Series 10kVA – 20kVA

Master Series (3P/1P) - Rack Mount

Master Series (3P/1P) - Rack mount is a true on-line double-conversion technology three-phase input / single-phase outputUPS system with 3U to 6U universal-mount case. It is designed to ensure maximum protection and power quality for any type of load, especially for mission critical applications such as data center systems, security systems and telecommunications. It is available from 10kVA and 20kVA capacities with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes.

Master Series (3P/1P) - Rack mount with IGBT technology, it provides generator compatible where handles frequency variations and other power fluctuations that occur during generator operation. Internal bypass to assure continuous power to critical devices during UPS maintenance and parallel redundancy which will back up the load in the event of critical component failure is available.

• True double-conversion

• DSP technology guarantees high performance

• Output Power Factor 0.8

• Wide input voltage range

• Active power factor correction in all phases

• 50Hz/60Hz frequency converter mode

• Eco mode operation for energy saving (ECO)

• Emergency power off function (EPO)

• Generator compatible

• SNMP+USB+RS-232 multiple communications

• Adjustable battery numbers

• Optional N+X parallel redundancy

Rear Panel

PRO83120RS/ RL PRO83110RS/ RL

Data

Centre 19” Rack

Mount Storage

PLCS Emergency Alarm Devices Local Area

Network (LAN)

Telecommunication Devices

For 10kVA to 20kVA model

1. RS-232 communication port 2. USB communication port

3. Emergency power off function connector (EPO connector) 4. Parallel port (only available for parallel model)

5. Intelligent slot 6. Fan

7. External maintenance by-pass switch connection 8. Input circuit breaker

9. Input/Output terminal 10. Output terminal 11. Battery terminal 12. Input terminal

PRO83120RS/ RL PRO83110RS/ RL 5

12 10

7 8

9

6 6

1 2 3

4 4 4

11

5

12

10

7

8 9

6 6

6 6

1 2 3 4 4 11 4

(22)

Options

• AS-400 Card for external alarm signal.

• SNMP Card for data communication via network connection

• MODBUS Card for communication

• Universal Rackmount Slider for installation in rack cabinets

• External Maintenance Bypass Switch (10kVA only)

Full Specifications

50 or 60Hz 300Vac <Vin <480Vac 360/ 380 /400/ 415VAC Nominal Voltage

Voltage Range Nominal Frequency Frequency Range Power Factor

46 ~ 64Hz

≧ 0.99

Capacity 10kVA/ 8kW 20kVA/ 16kW

Valve regulated Lead Acid battery (Maintenance free batteries) Type

Capacity

Recharge Time (Typical) Charging Current Standard Model

Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions

Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 Regulations

INPUT

MODELS PRO83110RS/ RL PRO83120RS/ RL

OUTPUT

BATTERY

MANAGEMENT ENVIRONMENT PHYSICAL OVERLOAD

INDICATORS EFFICIENCY

Support Windows® 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC USB/ RS-232

1.0 sec

>130%

100% < Load < 110%

LCD Display AC Mode

±1%

0.8 Static Regulation

Frequency Range Frequency

Power Factor Current Crest Ratio

Voltage Distortion Linear Load

Non-Linear Load ≦ 5% THD

≦ 2% THD

Waveform

1.0 A (max) 2.0A (max)

46 ~ 54Hz or 56 ~ 64Hz 50Hz or 60Hz auto selection or selectable

Pure Sinewave

9AH

9 hours recover to 90% capacity Up to 89%

3:1

Type Long-Run Model Capacity

Charging Current

10 mins

100% < Load < 130% 1 min

Depending on the application 4.0 A (max) Depending on the application

200/ 208/ 220/ 230/ 240VAC Output Voltage

668 x 438 x 133 (3U)

UPS Unit: 668 x 438 x 266 (6U) BatteryPack: 580 x 438 x 133 (3U) x 2

668 x 438 x 266 (6U)

<95% non-condensing 0°C - +40°C Operation Humidity

IP20 Protection

Ambient Temperature

≤58dBA @ 1 Meter ≤60dBA @ 1 Meter

Noise Level

UPS Unit: 668 x 438 x 133 (3U) Battery Pack: 580 x 438 x 133 (3U)

UPS Unit: 23

Battery Pack: 63 UPS Unit: 23

Battery Pack: 63 x 2

23 38

Dimension (mm) D x W × H

Net Weight (kgs) Dimension (mm) D × W × H Net Weight (kgs) Standard Model

Long-Run Model

L means Long-run model; S means Standard model.

Symbols: “/” meant for OR; “×” meant for Multiply of.

All specifications, designs and contents are subjected to changes without prior notice.

(23)

Online Master Series 10kVA – 20kVA

Master Series (3P/3P) - Tower

Master Series (3P/3P) - Tower is a true on-line double-conversion technology three-phase input/ three-phase output UPS system, it is an ideal for protection and power quality for small server room, medical devices, industrial processes and telecommunications facilities. It is available from 10kVA to 20kVA capacities with wide input voltage range and high accuracy output voltage to protect against the outages, disturbances and spikes.

Master Series (3P/3P) - Tower with IGBT technology, it provides generator compatible where handles frequency variations and other power fluctuations that occur during generator operation. Internal bypass to assure continuous power to critical devices during UPS maintenance and parallel redundancy which will back up the load in the event of critical component failure is available. An optional of isolation transformer can be attached to UPS unit without taking extra space.

• True double-conversion

• DSP technology guarantees high performance

• Wide input voltage range

• Active power factor correction in all phases

• 50Hz/60Hz frequency converter mode

• Eco mode operation for energy saving (ECO)

• Accepts dual power inputs

• Emergency power off function (EPO)

• Generator compatible

• SNMP+USB+RS-232 multiple communications

• Maintenance bypass available

• Optional N+X parallel redundancy

• Optional isolation transformer offers full isolation and complete common mode noise

Rear Panel

For 10kVA to 20kVA model

1. RS-232 communication port 2. USB communication port

3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot

7. Charger fan 8. Power stage fan

9. Maintenance bypass switch

10. Bypass Input Circuit Breaker (Only available for dual input unit) 11. Input circuit breaker

12. Input/Output terminal 13. Output terminal

14. External battery terminal (only available for Long-run model) 15. Bypass input terminal (Only available for dual input) 16. Input terminal

PRO83310S/L PRO83320S/L

CentreData Electro-Medical

Device Storage

PLCS Emergency Alarm Devices

E-Business (Server Farms,

ISP/ASP/POP) Local Area

Network (LAN)

Telecommunication Devices

5

13 16 1512 10 14

7

7 6 8

8

9 1 2 3 4

11

PRO83310S/L PRO83320S/L

References

Related documents

If the farmer sells apples and oranges separately, what is the best price for an orange and how much profit does he earn from orange sales.. If the farmer sells a bundle containing

Once registered, you can use this fully interactive site along with your product to enhance your learning experience, expand your knowledge, link with instructors, and connect with

n High efficiency over a 3A to milliamperes load range n Synchronous switching of internal NMOS power FETs n Wide input voltage range (4.5V to 18V).. n Output voltage adjustable

The ISL21090 is a ultra low noise, high DC accuracy precision voltage reference with wide input voltage range.. These devices are offered in an 8 Ld

High input impedance, common mode capability down to the negative supply and high output drive current capability are key factors in the design of wide range output voltage

High input impedance, common mode capability down to the negative supply and high output drive current capability are key factors in the design of wide range output voltage

High input impedance, common mode capability down to the negative supply and high output drive current capability are key factors in the design of wide range output voltage