Operating Documentation,
Issue 01
Flexi Multiradio BTS LTE Faults
DN0980455
Issue 05A
Approval Date 2013-09-23
Confidential
Nokia Siemens Networks is continually striving to reduce the adverse environmental effects of its products and services. We would like to encourage you as our customers and users to join us in working towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations for power use and proper disposal of our products and their compo-nents.
If you should have questions regarding our Environmental Policy or any of the environmental services we offer, please contact us at Nokia Siemens Networks for any additional information.
2 Id:0900d80580a2fb93 DN0980455 The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2013. All rights reserved
f
Important Notice on Product Safety
This product may present safety risks due to laser, electricity, heat, and other sources of danger.
Only trained and qualified personnel may install, operate, maintain or otherwise handle this product and only after having carefully read the safety information applicable to this product.
The safety information is provided in the Safety Information section in the “Legal, Safety and Environmental Information” part of this document or documentation set.
The same text in German:
f
Wichtiger Hinweis zur Produktsicherheit
Von diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder andere Gefahrenquellen ausgehen.
Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-anforderungen erfolgen.
Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal, Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentations-satzes.
DN0980455 Id:0900d80580a2fb93 3
Table of contents
This document has 278 pages.
Summary of changes . . . 10
1 Overview of Flexi Multiradio BTS LTE faults . . . 17
2 Flexi Multiradio BTS LTE fault and alarm handling . . . 18
3 BTS fault table . . . 19
4 Flexi Multiradio BTS LTE faults . . . 21
4.1 # autonomous reset as recovery action . . . 21
4.2 $Protocol Timing source lost [on unit $U] [, interface $IF] . . . 22
4.3 10b8b coding error in optical interface device <opt link/RP3>. . . 23
4.4 2M external reference missing. . . 24
4.5 3GPP/AISG communication administratively disabled . . . 25
4.6 [User defined] . . . 26
4.7 Address mismatch in summing . . . 28
4.8 AIS on unit $U, interface $IF . . . 29
4.9 Antenna Carrier configuration failure . . . 30
4.10 Antenna Line Device failure . . . 31
4.11 Antenna line device HW failure . . . 33
4.12 Antenna line device missing software . . . 34
4.13 Antenna Line Device Operation Failure . . . 35
4.14 Antenna line failure . . . 36
4.15 Antenna line faulty . . . 37
4.16 Antenna line operation degraded. . . 38
4.17 Antenna line switched off . . . 39
4.18 Antenna link is down . . . 40
4.19 Auto-negotiation mismatch, on unit $U, Ethernet interface $IF . . . 41
4.20 Automatic BTS Operator Certificate retrieval unsuccessful . . . 42
4.21 Automatic cell recovery not possible . . . 43
4.22 Base Station configuration alignment lost alarm . . . 44
4.23 Baseband bus configuration of <x> was rejected . . . 45
4.24 Baseband bus failure . . . 46
4.25 BB bus message in the wrong slot. . . 48
4.26 BB bus reception error (summing device) . . . 49
4.27 BB bus transmission error . . . 50
4.28 BFD $session down, egress, $sourceIP to $destinationIP . . . 51
4.29 BFD $session down, ingress, $sourceIP to $destinationIP . . . 52
4.30 BFD group $bfdGrpId down . . . 53
4.31 Boot configuration inconsistency detected. . . 54
4.32 BTS blocked . . . 55
4.33 BTS config error (Not enough HW for LCR) . . . 56
4.34 BTS configuration not supported . . . 57
4.35 BTS file error . . . 58
4.36 BTS internal SW management problem . . . 59
4 Id:0900d80580a2fb93 DN0980455
4.38 BTS master clock tuning failure . . . 62
4.39 BTS reference clock missing . . . 64
4.40 BTS reset required . . . 67
4.41 BTS reset required . . . 68
4.42 BTS reset time increased . . . 69
4.43 BTS SW download or activation failed . . . 70
4.44 BTS time not corrected . . . 71
4.45 BTS Trust Anchor expired or due to expire. . . 72
4.46 BTS vendor-specific file fault . . . 73
4.47 CCM fault level $ prio $p cause $c . . . 74
4.48 Cell blocked . . . 75
4.49 Cell configuration data distribution failed . . . 76
4.50 Cell power failure . . . 77
4.51 Cell reconfiguration data distribution failed . . . 78
4.52 Commissioning error: <x>. . . 79
4.53 Communication failure . . . 80
4.54 Configuration error: <x> . . . 81
4.55 Configuration file corrupted. . . 83
4.56 Cooling fan broken . . . 84
4.57 Cooling fan broken: <X> . . . 85
4.58 Cooling fan has reduced from the set speed . . . 86
4.59 Cooling fan is over speeding. . . 87
4.60 Cooling fan is over speeding. . . 88
4.61 Cooling fan speed decreased . . . 89
4.62 Critical BER detected on the optical connection to Radio Module . . . 90
4.63 Critical bit toggling error . . . 91
4.64 CRL update failure due to $cause . . . 92
4.65 DC voltage administratively disabled . . . 93
4.66 Dead Peer Detected . . . 94
4.67 Difference between BTS master clock and reference frequency . . . 95
4.68 Distributed site support not enabled . . . 98
4.69 DSP overheated . . . 99
4.70 EBER on unit $U, interface $IF. . . 100
4.71 Error in file server during file download type <fileTypeNumber> . . . 101
4.72 ETH AIS fault interface $IF level $l mac $x . . . 103
4.73 Failure during cell activation . . . 104
4.74 Failure in connection between BTS and iOMS or 3rd party tool . . . 105
4.75 Failure in optical RP3 interface . . . 106
4.76 Failure in replaceable baseband unit . . . 108
4.77 Failure in trace session . . . 110
4.78 Fan failure . . . 112
4.79 Fan module faulty: <X>. . . 113
4.80 Fan module operation degraded: <X> . . . 114
4.81 Fan vendor not detected . . . 115
4.82 Fatal OSE Error . . . 116
4.83 Fault diagnostics rule file error . . . 117
DN0980455 Id:0900d80580a2fb93 5
4.85 File corrupted in SW download . . . 119
4.86 File System access failed . . . 120
4.87 Filter unit operation failed . . . 121
4.88 Five failed logins to FTM due to wrong user name or password . . . 122
4.89 Flash operation failure . . . 123
4.90 FPGA SW update failed. . . 124
4.91 Frame clock deviation fault . . . 125
4.92 Frame clock missing . . . 126
4.93 FSP in resetting state . . . 127
4.94 FSP overheating . . . 128
4.95 FTM booted at $date due to $RCause . . . 129
4.96 FTM Toggling <Fault name> . . . 130
4.97 GPS Receiver alarm: control interface not available . . . 131
4.98 GPS receiver alarm: EEPROM invalid. . . 132
4.99 GPS receiver alarm: no stored position . . . 133
4.100 GPS receiver alarm: not tracking satellites . . . 134
4.101 GPS receiver alarm: position questionable . . . 135
4.102 GPS receiver alarm: survey in progress . . . 136
4.103 GTP-U Path Failure . . . 137
4.104 Heating element not working . . . 138
4.105 High memory consumption . . . 139
4.106 Incoherency in cell configuration . . . 140
4.107 Incoherency in cell configuration . . . 141
4.108 Incoherency In Cell Configuration . . . 142
4.109 Incoherency with RF Modules . . . 143
4.110 Incompatible SW version detected . . . 144
4.111 Incorrect radio network parameters . . . 145
4.112 Increased BER detected on the optical connection to Radio Module . 146 4.113 Internal MTU configuration failure . . . 147
4.114 Invalid configuration file . . . 148
4.115 Invalid frequency channel for the BTS HW . . . 149
4.116 IP address conflict . . . 150
4.117 Link OAM critical link event $E on unit $U, interface $F . . . 151
4.118 Link OAM link lost on unit $U, interface $F . . . 152
4.119 Link OAM loopback inserted on unit $U, interface $F by $P peer . . . . 153
4.120 LOF on unit $U, interface $IF . . . 154
4.121 LOMF on slot $U, interface $IF . . . 155
4.122 LOS on unit $U, [Ethernet] interface $IF . . . 156
4.123 Loss of primary Opt IF . . . 157
4.124 Low noise amplifier failure . . . 158
4.125 Mast Head Amplifier fault. . . 159
4.126 Mast Head Amplifier fault above current window, <line> . . . 160
4.127 Mast Head Amplifier fault below current window, <line> . . . 161
4.128 Master unit has lost connection to the slave unit . . . 162
4.129 Maximum number of neighbor eNBs/cells exceeded. . . 163
4.130 Message routing problem in receiver (RX) . . . 164
6 Id:0900d80580a2fb93 DN0980455
4.132 Missing or non-compliant SFP module on unit $U, interface $I . . . 166
4.133 Missing RNW parameter. . . 167
4.134 Missing RP3-01 link . . . 168
4.135 Module Clock faulty. . . 169
4.136 Module dangerously overheating . . . 170
4.137 Neighbor cell ambiguity detected . . . 171
4.138 No connection to Flexi transport submodule. . . 172
4.139 No connection to unit . . . 173
4.140 No feedback signal . . . 174
4.141 No MME capacity assigned by Core Network. . . 175
4.142 No module fan detected . . . 176
4.143 Not able to synchronize baseband bus with <x> . . . 177
4.144 NTP server is not accessible . . . 178
4.145 OIC MCU Buffer Full . . . 179
4.146 Optical Interface Data/Control/Ethernet Buffer Full. . . 180
4.147 Optical Interface faulty . . . 181
4.148 Oven oscillator clock missing . . . 182
4.149 Oven oscillator heating failure. . . 183
4.150 Oven oscillator Missing Pulse . . . 184
4.151 Overload collision in transmitter . . . 185
4.152 Parallel RP3-01 link length mismatch . . . 186
4.153 Peer system module connection lost . . . 187
4.154 Phich Power Boost not applied . . . 188
4.155 POST test failed . . . 189
4.156 Post test failed . . . 190
4.157 Power level not supported . . . 191
4.158 Power level not supported for cells using the same radio module . . . . 192
4.159 Power on #smodLogicalId #pwrLineId line switched off remotely by user . 193 4.160 PPS reference clock missing in startup . . . 194
4.161 PPS reference missing . . . 195
4.162 Radio master conflict . . . 197
4.163 Radio resources switched off . . . 198
4.164 RDI on unit $U, interface $IF . . . 199
4.165 Receiving failure in Optical Interface . . . 200
4.166 RET Antenna control failure . . . 201
4.167 RF BB bus configuration error . . . 202
4.168 RF BB bus connection transmission error . . . 203
4.169 RF BB bus synchronization error . . . 204
4.170 RF loss of secondary optical interface . . . 205
4.171 RF Module blocked . . . 206
4.172 RF Module configuring failed . . . 207
4.173 RF Module critical file not found . . . 208
4.174 RF Module failure . . . 209
4.175 RF Module file not found. . . 212
4.176 RF Module filter input power missing . . . 213
DN0980455 Id:0900d80580a2fb93 7
4.178 RF Module out of order . . . 215
4.179 RF Module power output faulty . . . 216
4.180 RF Power decreased . . . 217
4.181 RNW parameter mismatch. . . 218
4.182 RP3 routing collisions are detected on FR module . . . 219
4.183 RP3-01 link conflict . . . 220
4.184 RS485 IUANT port failure . . . 221
4.185 RX out of order . . . 222
4.186 S1 eNB configuration update . . . 223
4.187 S1 interface recovery failure . . . 224
4.188 S1 interface setup failure . . . 225
4.189 S1 SCTP path failure . . . 226
4.190 SFP HW Failure . . . 227
4.191 SRAM operation failure . . . 228
4.192 SRIO chain configuration was rejected . . . 229
4.193 Starting temperature below minimum . . . 230
4.194 Summing not enabled for message type . . . 231
4.195 Summing service default initialization failed . . . 232
4.196 Summing service release from reset failed . . . 233
4.197 SW corrupted . . . 234
4.198 SW fallback . . . 235
4.199 SyncE Quality Level Degraded on unit $UID, interface $IF . . . 236
4.200 SyncE SSM Timed Out on unit $UID, interface $IF . . . 237
4.201 Synchronization error in RP1 receiver . . . 238
4.202 Synchronization failure in Optical Interface <opt link/RP3 link>. . . 239
4.203 Synchronization lost. . . 240
4.204 Synchronization master missing . . . 241
4.205 System information broadcast parameters overflow . . . 242
4.206 System Module failure . . . 243
4.207 Technical log buffer freezing . . . 245
4.208 Temperature alarm . . . 246
4.209 Temperature too low (heating ongoing) . . . 248
4.210 Toggling: <Fault name> . . . 249
4.211 ToP master service $IP unusable . . . 250
4.212 Transmission clock missing . . . 251
4.213 Transmission parameters missing . . . 252
4.214 Transmission quality deteriorated . . . 253
4.215 Transmission rule collision in Muksu . . . 254
4.216 Transport layer connection failure in S1 interface . . . 255
4.217 Transport layer connection failure in X2 interface . . . 256
4.218 Transport module missing: $unit . . . 257
4.219 TWAMP PLR Threshold Crossed . . . 258
4.220 TWAMP RTT Threshold Crossed . . . 259
4.221 TX failure in MIMO . . . 260
4.222 TX out of order. . . 261
4.223 Unit (module) dangerously overheating . . . 262
8 Id:0900d80580a2fb93 DN0980455
4.225 Unit blocked . . . 264
4.226 Unit initialization failure . . . 265
4.227 Unit not supported by current BTS SW version . . . 266
4.228 Unit SW download failed. . . 267
4.229 Unit synchronization failed . . . 268
4.230 Unit temperature is high . . . 269
4.231 Unit unidentified . . . 270
4.232 Unknown HW resource . . . 271
4.233 Unsupported HW device . . . 272
4.234 Validation of signed file failed . . . 273
4.235 Vendor BTS certificate due to expire . . . 274
4.236 VSWR major alarm . . . 275
4.237 VSWR minor alarm . . . 276
4.238 X2 interface recovery failure . . . 277
DN0980455 Id:0900d80580a2fb93 9
List of tables
10 Id:0900d80580a3014f DN0980455
Summary of changes
Changes between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues.
Changes between issues 05 (2013-06-21, RL50) and 05A (2013-09-23, RL50) New faults:
• Antenna line device missing software • Antenna line switched off
• Antenna link is down
• Automatic BTS Operator Certificate retrieval unsuccessful • BTS vendor-specific file fault
• BTS SW download or activation failed • DC voltage administratively disabled • Failure in trace session
• GPS Receiver alarm: control interface not available • High memory consumption
• Neighbor cell ambiguity detected • Post test failed
• PPS reference missing • SFP HW Failure
• Unit synchronization failed • Unknown HW resource
• Vendor BTS certificate due to expire • X2 interface setup failure
Modified faults:
• $Protocol Timing source lost [on unit $U] [, interface $IF] • AIS on unit $U, interface $IF
• Antenna Carrier configuration failure
• Auto-negotiation mismatch, on unit $U, Ethernet interface $IF • BFD group $bfdGrpId down
• BFD $session down, egress, $sourceIP to $destinationIP • BFD $session down, ingress, $sourceIP to $destinationIP • BTS reset required
• BTS time not corrected
• BTS Trust Anchor expired or due to expire • CCM fault level $ prio $p cause $c
• Cell configuration data distribution failed • Cell power failure
• Cell reconfiguration data distribution failed • Commissioning error: <x>
• Cooling fan broken • Cooling fan broken: <X>
• Cooling fan has reduced from the set speed • Cooling fan is over speeding
DN0980455 Id:0900d80580a3014f 11 • Critical BER detected on the optical connection to Radio Module
• CRL update failure due to $cause • Dead Peer Detected
• EBER on unit $U, interface $IF
• ETH AIS fault interface $IF level $l mac $x
• Five failed logins to FTM due to wrong user name or password • FTM booted at $date due to $RCause
• Incompatible SW version detected
• Link OAM critical link event $E on unit $U, interface $F • Link OAM link lost on unit $U, interface $F
• Link OAM loopback inserted on unit $U, interface $F by $P peer • LOF on unit $U, interface $IF
• LOMF on slot $U, interface $IF
• LOS on unit $U, [Ethernet] interface $IF
• Master unit has lost connection to the slave unit • Maximum number of neighbor eNBs/cells exceeded
• Missing or non-compliant SFP module on unit $U, interface $I • Missing RP3-01 link
• Not able to synchronize baseband bus with <x> • NTP server is not accessible
• Parallel RP3-01 link length mismatch • Radio master conflict
• RDI on unit $U, interface $IF • RF Module failure
• RX out of order
• S1 interface recovery failure • S1 interface setup failure
• SyncE Quality Level Degraded on unit $UID, interface $IF • SyncE SSM Timed Out on unit $UID, interface $IF • Synchronization lost
• Technical log buffer freezing • ToP master service $IP unusable • Transport module missing: $unit • TWAMP PLR Threshold Crossed • TWAMP RTT Threshold Crossed • Unsupported HW device
• VSWR minor alarm
• X2 interface recovery failure
Removed fault:
• License missing for feature $feature on interface $if • Maximum number of LTE neighbor relations is exceeded • Maximum number of LTE NR per cell and carrier is exceeded • Pipe dangerously overheating
• RF sensor temperature too high in Flexi Lite • Routing misconfiguration for application $a
12 Id:0900d80580a3014f DN0980455
Changes between issues 04C (2013-04-22, RL40) and 05 (2013-06-21, RL50) New faults:
• 3GPP/AISG communication administratively disabled
• Auto-negotiation mismatch, on unit $U, Ethernet interface $IF • Automatic cell recovery not possible
• BB bus message in the wrong slot
• BTS Trust Anchor expired or due to expire • Cell reconfiguration data distribution failed • Faulty configuration of system modules
• Maximum number of LTE neighbor relations is exceeded • Maximum number of LTE NR per cell and carrier is exceeded • Message routing problem in receiver (RX)
• Overload collision in transmitter
• RP3 routing collisions are detected on FR module • S1 eNB configuration update
• Summing not enabled for message type • Synchronization master missing
• Transmission rule collision in Muksu
Modified faults:
• # autonomous reset as recovery action
• $Protocol timing source lost on unit $U [, interface $IF] • 10b8b coding error in optical interface device <opt link/RP3> • 2M external reference missing
• [User defined]
• AIS on unit $U, interface $IF
• Antenna Carrier configuration failure • Antenna line device HW failure • Antenna line faulty
• Baseband bus configuration of <x> was rejected • Baseband bus failure
• BB bus reception error (summing device) • BFD group $bfdGrpId down
• BFD session down in egress direction for session $S • BFD session down in ingress direction for session $S • Boot configuration inconsistency detected
• BTS blocked
• BTS configuration not supported • BTS file error
• BTS internal SW management problem • BTS is uncommissioned
• BTS master clock tuning failure • BTS reference clock missing • BTS reset required
DN0980455 Id:0900d80580a3014f 13 • CCM fault level $ prio $p cause $c
• Cell blocked
• Cell configuration data distribution failed • Cell power failure
• Commissioning error: <x> • Communication failure • Configuration error: <x> • Cooling fan broken: <X>
• CRL update failure due to cause $C • Dead Peer Detected
• Difference between BTS master clock and reference frequency • Distributed site support not enabled
• EBER on unit $U, interface $IF
• ETH AIS fault interface $IF level $l mac addr $x
• Failure in connection between BTS and iOMS or 3rd party tool • Failure in optical RP3 interface
• Fan module operation degraded: <X> • Fault diagnostics rule file error • File corrupted in SW download • File System access failed
• Five failed logins to FTM due to wrong user name or password • Flash operation failure
• Frame clock missing • FSP in resetting state • FSP overheating
• FTM booted at $date due to $RCause • FTM Toggling <Fault name>
• GPS receiver alarm: EEPROM invalid • GPS receiver alarm: no stored position • GPS receiver alarm: position questionable • GPS receiver alarm: survey in progress • GTP-U Path Failure
• Incorrect radio network parameters
• Increased BER detected on the optical connection to Radio Module • Internal MTU configuration failure
• Invalid configuration file
• License missing for feature $feature on interface $if • Link OAM critical link event $E on unit $U, interface $F • Link OAM link lost on unit $U, interface $F
• Link OAM loopback inserted on unit $U, interface $F by $P peer • LOF on unit $U, interface $IF
• LOMF on slot $U, interface $IF
• LOS on unit $U, [Ethernet] interface $IF • Loss of primary Opt IF
• Low noise amplifier failure
14 Id:0900d80580a3014f DN0980455 • Missing or non-compliant SFP module on unit $U, interface $I
• Missing RNW parameter • Missing RP3-01 link • Module Clock faulty
• No connection to Flexi transport submodule • No connection to unit
• Not able to synchronize baseband bus with <x> • NTP server is not accessible
• OIC MCU Buffer Full • Optical Interface faulty • Oven oscillator clock missing • Oven oscillator heating failure • Oven oscillator Missing Pulse • Parallel RP3-01 link length mismatch • Pipe dangerously overheating
• SyncE Quality Level Degraded on unit $UID, interface $IF • POST test failed
• Power level not supported for cells using the same radio module • Power on #smodLogicalId #pwrLineId line switched off remotely by user • PPS reference clock missing in startup
• Radio resources switched off • RDI on unit $U, interface $IF • Receiving failure in Optical Interface • RF BB bus configuration error
• RF BB bus connection transmission error • RF loss of secondary optical interface • RF Module blocked
• RF Module configuring failed • RF Module critical file not found • RF Module filter input power missing • RF Module gain adjusting failure • RF Module out of order
• RF Module power output faulty • RNW parameter mismatch
• Routing misconfiguration for application $a • RP3-01 link conflict
• RS485 IUANT port failure • RX out of order
• S1 interface recovery failure • S1 interface setup failure • S1 SCTP path failure • SRAM operation failure
• SRIO chain configuration was rejected
• SyncE SSM Timed Out on unit $UID, interface $IF • SW corrupted
DN0980455 Id:0900d80580a3014f 15 • Synchronization lost
• System information broadcast parameters overflow • System Module failure
• Temperature alarm
• Temperature too low (heating ongoing) • Toggling: <Fault name>
• Transport layer connection failure in S1 interface • Transport layer connection failure in X2 interface • Transport module missing: $unit
• TWAMP PLR Threshold Crossed • TWAMP RTT Threshold Crossed • TX failure in MIMO
• TX out of order
• Unit (module) dangerously overheating • Unit blocked
• Unit initialization failure
• Unit not supported by current BTS SW version • Unit SW download failed
• Unit temperature is high
• Vendor BTS certificate due to expire • VSWR major alarm
• VSWR minor alarm
• X2 interface recovery failure
Removed faults:
• Antenna link is down
• Automatic BTS Operator Certificate retrieval unsuccessful • BB bus message collision error
• BTS SW download or activation failed • Firmware SW mismatch
• GPS Receiver alarm: control interface not available • GPS Receiver alarm: not tracking satellites
• High memory consumption • Incoherency with RF Modules
• Invalid frequency channel for the BTS HW • Post test failed
• PPS reference missing • Unit synchronization failed • Unknown product code
• X2 neighbor cell configuration inconsistency
Changes between issues 04B (2013-01-23, RL40) and 04C (2013-04-22, RL40) New faults:
• High memory consumption • Loss of primary Opt IF
16 Id:0900d80580a3014f DN0980455 • File System access failed
DN0980455 Id:0900d805809667b0 17
1 Overview of Flexi Multiradio BTS LTE faults
This document describes fault and alarm handling of the Flexi Multiradio Base Station LTE. The base station software uses these faults and alarms as a basis for internal diag-nosis and fault reporting to the Operations Support System (OSS) and BTS Site Manager.
18 Id:0900d805808057a2 DN0980455
2 Flexi Multiradio BTS LTE fault and alarm
handling
Base station (BTS) alarm handling is based on unit or module state information. It prevents the sending of unnecessary alarms by checking and updating unit states. Fault messages come either from hardware devices or software components. The faults are system or hardware specific. The Fault Diagnosis System creates upper network alarms, which are based on an analysis of the faults, and sends them to the BTS Site Manager.
In addition NetAct is used for handling the BTS alarms.
The BTS is able to maintain alarm handling after it has been commissioned and is in a configured state. During the start-up, the BTS waits for the real-time clock from the Network Time Protocol (NTP) server, and the fault diagnosis starts after the time has been set or a time-out has been detected. If the BTS is unable to set the time using the NTP server, the default time (1.1.2004) will be used.
Flexi Multiradio BTS LTE transmission alarms
In Flexi Multiradio BTS LTE, transmission alarms are reported as Base station transmis-sion alarms (7665) towards OMS or NetAct. In Flexi Multiradio BTS LTE, transmistransmis-sion equipment uses the base station interface. Therefore, retrieval of the alarm information will be mapped either in the OMS or in NetAct to distinguish between the alarms by using the fault ID.
Instructions for solving problems
When starting to solve a problem, first refer to the instructions given in the individual alarm descriptions.
Verify the configuration of a BTS by checking the commissioning, cabling and correct installation of the modules at the BTS. Make sure the environment does not cause the fault.
If an active alarm is a 'Start' alarm, a unit block/unblock (if supported by the unit) or a site reset is required to cancel it. If the site reset or unit block/unblock does not help, replace the faulty unit or module. See the fields 'Fault source' and 'Instructions' in the corresponding alarm description.
Blocking and unblocking
The 'Cancel' alarms are always sent to hosts (LTE BTS Site Manager). When the unit or cell is in a blocked state, the 'Start' alarms are only sent to LTE BTS Site Manager. When a unit or cell is unblocked, all the active alarms related to the unblocked unit, module, or cell are automatically sent to the hosts.
DN0980455 Id:0900d80580a30734 19
3 BTS fault table
Fault name: The name of the fault.
Used in products: The name of the product in question.
Detecting unit: The unit that detects the fault.
Source: The equipment suspected to be faulty (sub-unit in parentheses).
Note that sometimes the actual source of the fault is different than the one that detects the fault.
Meaning: A description of the fault situation.
State: The options are:
Event (Transient or Distur) • Notification type fault
• 'Event' fault is not cancelled, because it is never active • No recovery actions
• Event type fault is shown in the BTS Site Manager as 'Transient' Start
• A fault situation
• The fault is not automatically cleared (without manual operation and maintenance work), even though the problem has been solved, but requires at least block-ing/unblocking the unit or site reset.
• Recovery actions depend on the reported severity Start/Cancel
• Faults can be in a start or cancel state
• The fault is automatically cleared when the problem has been solved
Unit status: The options are:
Out of order The unit does not work
Degraded The main functions of the unit work, but not all
Working All functions are working, but some trouble has been notified
Info Status change information
Unit status attributes:
Used when there is more than one unit status possible. In case multiple unit status options are possible, unit status depends on the fault source.
Effect: A description of how this fault affects the operations of this unit, and how it affects the operations of other units. The following questions are considered:
Does the status of the unit or its sub-units have any effect on the interpretation of the fault?
Does the fault have an effect on other active faults? Table 1 Description of the fields in the fault table
20 Id:0900d80580a30734 DN0980455
Reported alarms: 7650 BASE STATION FAULTY • Start, disables all cells • Cancel, causes a site reset
• No new 7651, 7653 or 7654 alarms are reported when 7650 is active 7651 BASE STATION OPERATION DEGRADED
• There is no limit to how many 7651 alarms can be active at the same time 7652 BASE STATION NOTIFICATION
• There is no limit to how many 7652 alarms can be active at the same time 7653 CELL FAULTY
• Start, the affected cell state is set disabled • Cancel, the affected cell state is set enabled 7654 CELL OPERATION DEGRADED
• There is no limit to how many 7654 alarms can be active at the same time 7655 CELL NOTIFICATION
• There is no limit to how many 7655 alarms can be active at the same time 7656 BASE STATION CONNECTIVITY LOST
7657 BASE STATION CONNECTIVITY DEGRADED 7665 BASE STATION TRANSMISSION ALARM
• In case of faulty transmission equipment or transmission software, this alarm is reported towards the OMS or NetAct.
• Transmission alarms do not have dependencies to other BTS alarms.
LED display: The colour of the LED representing the fault level of the unit. The options are:
Stable red Major alarm
Blinking red Minor alarm
Stable yellow Unit in standby state or unit blocking
Blinking yellow Unit in self-heating state or software downloading Stable green Unit on and working
Alternating red and green MHA faulty
Instructions: Describes the actions required to clear the fault. Table 1 Description of the fields in the fault table (Cont.)
DN0980455 Id:0900d80580a30151 21
4 Flexi Multiradio BTS LTE faults
4.1 # autonomous reset as recovery action
Fault ID and name 52: EFaultId_UnitAutonomousResetAlUsed in products FlexiBTS, LTE
Detecting unit FCM/FCT
Source FCM/FCT, FR, FSP
Meaning The BTS tries to correct a fault situation by performing a recovery reset to a unit, the site or the BTS. In case of RF module reset in RF chaining configura-tion BTS resets also all RF modules that are further in chain.
State Transient
Unit status Working
Unit status attributes
Effect The BTS is operational.
Reported alarms 7652 BASE STATION NOTIFICATION
LED display Stable green
Instructions Check the fault history and other active faults of the unit.
Note! This fault does not require any (special) actions. Related faults
22 Id:0900d80580a30045 DN0980455
4.2 $Protocol Timing source lost [on unit $U] [, interface $IF]
Fault ID and name 61059: FTM_TIMING_SOURCE_LOSUsed in products LTE
Detecting unit FTLB, FTIB, FSM, FTIF
Source STPG
Meaning One of the synchronisation sources in the configured priority list is unavailable. This can be the primary or the secondary clock source. In the alarm: Protocol can be PDH, Timing over Packet (ToP) and Synchronuous ethernet. Unit Number is optional: -For PDH and Synchronous Ethernet, Unit number is 0 or 1. -It is not present for Timing Over Packet(TOP). The interface value is optional: - For PDH the value range depends on the hardware unit type: 1..16 - For Synchonuous Ethernet the value range = 1..3 - It is not present for Timing over Packet.
State Start / Cancel
Unit status Minor
Unit status attributes
Effect The BTS may have to use a synchronization interface that has a lower clock quality: if the primary clock source has been lost, the BTS switches automati-cally to the secondary clock source. If both the primary and the secondary clock sources are lost, the BTS switches to the internal clock.
Reported alarms 7665 BASE STATION TRANSMISSION ALARM
LED display Stable Green
Instructions Use BTS Site Manager to check which interfaces have been configured as synchronization sources.
For all interfaces, do as follows:
1. Check that the cables are connected to the correct connectors. 2. Check whether the interface at the far end is switched on.
3. Check whether there are active alarms at the far end. If there are, follow the instructions on handling those alarms.
4. To verify that the hardware of the interface unit works correctly, connect a loop cable and check whether the alarm disappears.
Monitor the received clock quality. Related faults
DN0980455 Id:0900d80580a30034 23
4.3 10b8b coding error in optical interface device <opt
link/RP3>
Fault ID and name 2004: EFaultId_OIC_LVDSRecAl
Used in products LTE
Detecting unit FCM, FCT
Source OptIF
Meaning The fibre cable has an interference; the data becomes faulty. A physical con-nection failure between the optical interface and the summing function (caused by bad circuit joints, for example).
State Start / Cancel
Unit status Degraded
Unit status attributes
Effect The cell operation is degraded. The optical interface loses its synchronization if the amount of errors exceeds the defined limit.
Reported alarms 7654 CELL OPERATION DEGRADED LED display Blinking red(optical interfaces)
Instructions 1. Reset the RF Module behind the faulty optical interface by blocking/unblock-ing it.
2. If that does not clear the fault situation, replace the RF Module that causes the alarm.
3. Reset the System Module.
4. If the System Module is the only source causing the alarm, or actions men-tioned above do not clear the fault situation, replace the System Module that causes the alarm.
Related faults Failure in optical RP3 interface
24 Id:0900d80580a300ec DN0980455
4.4 2M external reference missing
Fault ID and name 1899: EFaultId_2MExtRefMissAl Used in products FlexiBTS, LTE
Detecting unit FCM/FCT
Source FCM/FCT
Meaning The reference clock monitoring has detected a loss of 2.048MHz signal received from an external reference source, connected to Sync In interface of the System Module.
State Start / Cancel
Unit status Degraded
Unit status attributes
Effect If other references are available, the synchronization reference source changes to another source. Tuning then follows this new reference. If other ref-erences are not available, the BTS master clock (OCXO) tuning is halted and the BTS synchronization drops to holdover mode.
Reported alarms 7651 BASE STATION OPERATION DEGRADED 7652 BASE STATION NOTIFICATION
LED display Blinking red
Instructions Note! Perform the steps below in the listed order until the alarm disappears.
1. Check the cabling (connected to Sync In interface).
2. Check if the 2.048MHz reference source is working normally and the 2.048MHz signal is available.
3. Replace the alarming module. Related faults BTS reference clock missing
DN0980455 Id:0900d80580a300cd 25
4.5 3GPP/AISG communication administratively disabled
Fault ID and name 4142: EFaultId_Communication3gppAdministrativelyDisabledAlUsed in products FlexiBTS, LTE
Detecting unit FCM, FCT
Source ALD
Meaning HDLC link is disabled for reporting Antenna Line or IUANT port.
State Start / Cancel
Unit status Out of order
Unit status attributes
Effect HDLC link will be disabled on reporting Antenna Line or IUANT port. Reported alarms 7652 BASE STATION NOTIFICATION
7654 CELL OPERATION DEGRADED
LED display STABLE GREEN
Instructions To revert change,the Communication3gppEnabled parameter should be enabled for reporting Antenna Line.
26 Id:0900d80580a3002e DN0980455
4.6 [User defined]
Fault ID and name 1400: EFaultId_ExtAl0 1401: EFaultId_ExtAl1 1402: EFaultId_ExtAl2 1403: EFaultId_ExtAl3 1404: EFaultId_ExtAl4 1405: EFaultId_ExtAl5 1406: EFaultId_ExtAl6 1407: EFaultId_ExtAl7 1408: EFaultId_ExtAl8 1409: EFaultId_ExtAl9 1410: EFaultId_ExtAl10 1411: EFaultId_ExtAl11 1412: EFaultId_ExtAl12 1413: EFaultId_ExtAl13 1414: EFaultId_ExtAl14 1415: EFaultId_ExtAl15 1416: EFaultId_ExtAl16 1417: EFaultId_ExtAl17 1418: EFaultId_ExtAl18 1419: EFaultId_ExtAl19 1420: EFaultId_ExtAl20 1421: EFaultId_ExtAl21 1422: EFaultId_ExtAl22 1423: EFaultId_ExtAl23 1424: EFaultId_ExtAl24 1425: EFaultId_ExtAl25 Used in products FlexiBTS, LTE
Detecting unit FCM, FCT
Source FCM, FCT
Meaning High or low voltage on the external alarm line. The user specifies the fault text during commissioning.
State Start / Cancel
Unit status Working
Unit status attributes
Effect No actual effect to BTS functionality. This is user-specific. Reported alarms
DN0980455 Id:0900d80580a3002e 27
LED display N/A
Instructions [User defined] Related faults
28 Id:0900d80580a3003a DN0980455
4.7 Address mismatch in summing
Fault ID and name 2019: EFaultId_Muksu_SsubMmAl
Used in products LTE
Detecting unit FCM, FCT
Source FCM, FCT, FSP
Meaning There is a baseband bus address mismatch in the summing. There are two possible causes: 1. A configuration error (two different baseband units function-ing) - after an acknowledgement the fault returns. 2. Data corruption on the bus - appears once when unsynchronized data is sent by the baseband.
State Start / Cancel
Unit status Degraded
Unit status attributes
Effect RP3 traffic from the baseband is malfunctioning. The System Module operation is degraded.
Reported alarms 7651 BASE STATION OPERATION DEGRADED
LED display Blinking red
Instructions Check the antenna mapping to the local cells in the commissioning file. Related faults Baseband Bus failure
DN0980455 Id:0900d80580a30040 29
4.8 AIS on unit $U, interface $IF
Fault ID and name 61151: FTM_AIS
Used in products LTE
Detecting unit FTLB, FTIB, FSM, FTIF
Source PPTT
Meaning Alarm indication signal is received. This signal is generated by an intermediate PDH device in the forward direction because it detects a problem in its receive signal. All other transmission alarms related to this signal are suppressed. Probable cause: There is a transmission problem somewhere in the intermedi-ate network and AIS is sent instead of user traffic.
State Start / Cancel
Unit status Major
Unit status attributes
Effect Possible impact on the connections over the interface in question: - no calls are possible - loss of remote management access to other network elements in the RAN
Reported alarms 7665 BASE STATION TRANSMISSION ALARM
LED display Blinking red
Instructions Check the intermediate transmission network for alarms indicating the root cause and follow the instructions for handling these alarms.
30 Id:0900d80580a30089 DN0980455
4.9 Antenna Carrier configuration failure
Fault ID and name 6259: EFaultId_AntennaCarrierMessageFailed
Used in products LTE
Detecting unit FCM/FCT
Source TX1-n/RX1-n
Meaning Antenna carrier resources were not successfully set up during cell setup or cell deletion procedure because of failure of RX or TX resource. Affected cell might be not operational.
State Start
Unit status Out of order
Unit status attributes
Effect Affected cell might be not fully operational. Reported alarms 7653 CELL FAULTY
7654 CELL OPERATION DEGRADED
LED display N/A
Instructions Perform the steps below in the listed order until the BTS fault disappears. 1.Check cables towards Radio Module
2.Reset Radio Module 3.Remove faulty unit Related faults RF Module failure
DN0980455 Id:0900d80580a30055 31
4.10 Antenna Line Device failure
Fault ID and name 3100: EFaultId_AntennaLineFailure
Used in products LTE
Detecting unit FSM, Antenna Line Device itself
Source FR, MHA, TILT, EFIL
Meaning The System Module or the device itself has detected an abnormal operation or a failure in the antenna line device.
State Start / Cancel
Unit status N/A
Unit status attributes
Effect Depending on the reported alarms, the fault situation might have no impact on the operation (BASE STATION or CELL NOTIFICATION), the cell capacity might have decreased (CELL OPERATION DEGRADED), or the cell might not be operational at all (CELL FAULTY).
Reported alarms 7652 BASE STATION NOTIFICATION 7653 CELL FAULTY
7654 CELL OPERATION DEGRADED 7655 CELL NOTIFICATION
LED display N/A
Instructions Note: Perform the steps below in the listed order until the BTS fault disappears.
1. Check the antenna line and antenna line devices. Make sure that the antenna line connectors are in the right torque.
2. Reset the alarming RF module by blocking/unblocking it.
3. Replace the faulty parts and/or devices along the antenna line.
32 Id:0900d80580a30055 DN0980455 Related faults No connection to unit
10: EFaultId_NoConnectionToUnitAl
Antenna line device HW failure 1847: EFaultId_HardwareErrorAl
Communication failure
1806: EFaultId_CommunicationFailureAl
Antenna Line Device Operation Failure 1871: EFaultId_BusyAl
1872: EFaultId_FormatErrorAl
1873: EFaultId_UnsupportedProcedureAl 1874: EFaultId_OutOfRangeAl
DN0980455 Id:0900d80580a30014 33
4.11 Antenna line device HW failure
Fault ID and name 1847: EFaultId_HardwareErrorAl Used in products FlexiBTS, LTE
Detecting unit FR, TILT
Source RX, TX, TILT, MHA, EFIL
Meaning A hardware failure detected by an antenna line device. Usually this is a perma-nent fault (the hardware is broken).
State Start / Cancel
Unit status Degraded
Unit status attributes
Effect The antenna line device is not working properly. The cell operation is degraded. Reported alarms 7652 BASE STATION NOTIFICATION
7654 CELL OPERATION DEGRADED
LED display Stable Green (7652) Alternating Red and Green (7654)
Instructions 1. Block/unblock the Radio module to give a power-off reset to the antenna line devices.
2. If that does not help, replace the antenna line device. Related faults Antenna Line Device failure
34 Id:0900d80580a300e9 DN0980455
4.12 Antenna line device missing software
Fault ID and name 1848: EFaultId_WorkingSoftwareMissingAl Used in products FlexiBTS, LTE
Detecting unit MHA, TILT
Source MHA, TILT
Meaning The unit is in Download Mode State.
State Start / Cancel
Unit status Degraded
Unit status attributes
Effect The device is out of use.
Reported alarms 7652 BASE STATION NOTIFICATION 7654 CELL OPERATION DEGRADED
LED display N/A
Instructions 1. Replace the antenna line device. Related faults
DN0980455 Id:0900d80580a3003d 35
4.13 Antenna Line Device Operation Failure
Fault ID and name 1871: EFaultId_BusyAl
1872: EFaultId_FormatErrorAl
1873: EFaultId_UnsupportedProcedureAl 1874: EFaultId_OutOfRangeAl
Used in products LTE
Detecting unit FSM
Source Flexi Filter, FA, AISG MHA, TILT
Meaning The device is not working properly, the configuration is not valid, or a given parameter is incorrect.
State Start / Cancel
Unit status Degraded
Unit status attributes
Effect Some antenna line device functions may not work properly. Reported alarms 7652 BASE STATION NOTIFICATION
7655 CELL NOTIFICATION
LED display Blinking red (Filter), Stable green (other)
Instructions 1. Check the functionality of the antenna line device.
2. Check the compatibility between the antenna line device and the BTS.
3. Check that the given parameters are in the valid range. Related faults Antenna Line Device failure
36 Id:0900d80580a3000c DN0980455
4.14 Antenna line failure
Fault ID and name 1836: EFaultId_ALOvercurrentAl
Used in products LTE
Detecting unit Flexi Filter, FR
Source Antenna line
Meaning Radio Module (60W RRH) or Filter (all others) has detected overcurrent on the antenna line. The antenna line might be damaged (short circuit) or some antenna line device is causing overload. All antenna line devices powered by the antenna line are out of order.
State Start / Cancel
Unit status Degraded
Unit status attributes
Effect The antenna line is not operating correctly. The cell capacity decreases. Reported alarms 7654 CELL OPERATION DEGRADED
LED display Alternating red and green (RF working, Antenna Line faulty)
Instructions 1. Check the antenna line and antenna line devices. Fix or replace the faulty parts/devices.
2. Alarm is cancelled only at RF Module reset or BTS reset. Related faults
DN0980455 Id:0900d80580a300b8 37
4.15 Antenna line faulty
Fault ID and name 4045: EFaultId_AntennaLineFaultyAl Used in products FlexiBTS, LTE
Detecting unit FR
Source Antenna line
Meaning An alarm message has been received from the antenna line. The antenna line is faulty.
State Start / Cancel
Unit status Out of order
Unit status attributes
Effect The antenna line is not operating correctly. The cell is disabled. Reported alarms 7653 CELL FAULTY
7654 CELL OPERATION DEGRADED LED display Periodic red and green
Instructions 1. Check the antenna line and antenna line device that causes the alarm. 2. Fix or replace the faulty parts/devices.
Related faults
38 Id:0900d80580a30085 DN0980455
4.16 Antenna line operation degraded
Fault ID and name 4046: EFaultId_AntennaLineDegradedAl
Used in products LTE
Detecting unit FR
Source Antenna Line
Meaning An alarm message has been received from the antenna line device. The antenna line operation is degraded.
State Start / Cancel
Unit status Degraded
Unit status attributes
Effect The antenna line is not operating correctly. The cell capacity decreases. Reported alarms 7654 CELL OPERATION DEGRADED
LED display Periodic red and green (RF working, Antenna Line degraded)
Instructions 1. Check the antenna line and antenna line device that causes the alarm. 2. Fix or replace the faulty parts/devices.
DN0980455 Id:0900d80580a300dd 39
4.17 Antenna line switched off
Fault ID and name 1957: EFaultId_AntennaLineSwitchedOffAl Used in products FlexiBTS, LTE
Detecting unit FR
Source Antenna line
Meaning Antenna line has been disabled to protect HW, that is because of high reflection conditions.
State Start
Unit status Out of order
Unit status attributes
Effect The cell is disabled. Downlink signal transmission on the given antenna line is disabled and corresponding FR transmitter is unusable, hence overall FR state is affected.
Reported alarms 7653 CELL FAULTY
7654 CELL OPERATION DEGRADED
LED display Stable red (all antenna lines of the RF module are faulty); Blinking red (not all antenna lines of the RF module are faulty)
Instructions 1. Check the antenna cables, connectors, antenna and possible antenna line devices.
2. Check the antenna line (TX-cable-antenna) impedance matching. Related faults
40 Id:0900d80580a30058 DN0980455
4.18 Antenna link is down
Fault ID and name 476: EFaultId_Rp3BusError Used in products FlexiBTS, LTE
Detecting unit FSPC
Source FSP, FSM
Meaning Antenna (RP3) link is down: transmitter or receiver drops from synchronization.
State Start
Unit status Out of order
Unit status attributes
Effect BTS is not operational or the capacity is degraded. Reported alarms 7650 BASE STATION FAULTY
7651 BASE STATION OPERATION DEGRADED LED display Stable red (7650), Blinking red (7651)
Instructions 1. If the alarming module is the System Module (FSM1), restart BTS. 2. If that does not help, replace the alarming FSM.
Related faults Failure in optical RP3 interface
3030: EFaultId_FailureInOptical_Rp3Interface
Failure in replaceable baseband unit 3003: EFaultId_FbiaFailureAl
DN0980455 Id:0900d80580a300a1 41
4.19 Auto-negotiation mismatch, on unit $U, Ethernet interface
$IF
Fault ID and name 61607: AUTO NEGO MIS MATCH
Used in products LTE
Detecting unit FTIB, FTFB, FTLB
Source ETHLK
Meaning This alarm indicates that there is a mismatch between BTS configuration and auto-negotiation result.
State Start / Cancel
Unit status Major
Unit status attributes
Effect If the alarm is active, then potentially there is a synchronization loop Reported alarms 7665 BASE STATION TRANSMISSION ALARM
LED display None
Instructions Try with local management or site support equipment. Related faults
42 Id:0900d80580a30064 DN0980455
4.20 Automatic BTS Operator Certificate retrieval unsuccessful
Fault ID and name 61510: NO_CERTIFICATEUsed in products LTE
Detecting unit FTLB, FTIB, FSM, FTIF
Source CERTH
Meaning A requested certificate could not be retrieved from the certificate authority (CA). A requested certificate could not be renewed from the certificate authority (CA). A requested certificate could not be retrieved as the number of certificates received from repository server (RA) or certificate authority (CA) are more than expected.
State Start / Cancel
Unit status Major
Unit status attributes
Effect The requested service is not available.
Reported alarms 7665 BASE STATION TRANSMISSION ALARM
LED display Blinking red
Instructions Provide the certificate. Related faults
DN0980455 Id:0900d80580a300e4 43
4.21 Automatic cell recovery not possible
Fault ID and name 6277: EFaultId_AutomaticCellRecoveryNotPossible Used in products FlexiBTS, LTE
Detecting unit FCT
Source LCR
Meaning Base station executed baseband board (FSP) recovery activities. All baseband boards are available again but not all cells could be restored. To restore the functionality of remaining cell, a base station reset is required.
State Start
Unit status Out of order
Unit status attributes
Effect The cell that cannot be recovered remains unavailable. Reported alarms 7653 CELL FAULTY
LED display None
Instructions Reset (block/unblock) the BTS in order to recover the faulty cell. Related faults
44 Id:0900d80580a300e7 DN0980455
4.22 Base Station configuration alignment lost alarm
Fault ID and name 4171: EFaultId_BaseStationConfigurationAlignmentLostAl
Used in products LTE
Detecting unit FCM, FCT
Source FCM (FSMr2), FCT (FSMr3)
Meaning The configuration data alignment between BTS and NetAct is lost. No Ack or any nackReason from OMS for Configuration Change Notifications (CCN) or buffered CCNs is lost because too long BTS O&M interface connection break.
State Start / Cancel
Unit status Working
Unit status attributes Working: There is only misalingment in NetAct database and BTS is working normally.
Effect The BTS continues working normally with all cells. Reported alarms 7652 BASE STATION NOTIFICATION
LED display N/A
Instructions Upload BTS configuration from NetAct. Related faults
DN0980455 Id:0900d80580a30015 45
4.23 Baseband bus configuration of <x> was rejected
Fault ID and name 1811: EFaultId_BbBus_ConfFailedAl Used in products FlexiBTS, LTE
Detecting unit FCM/FCT, FSP
Source FSM/FCT, FSP, OptIF
Meaning The baseband bus related configuration of <x> was rejected by the HW SW, DSP or RF SW.
State Start
Unit status Out of order
Unit status attributes
Effect This fault prevents the BTS from functioning. Depending on <x>, some pro-cessing resources, some cells, or the whole BTS are out of order.
Reported alarms 7650 BASE STATION FAULTY
7651 BASE STATION OPERATION DEGRADED 7653 CELL FAULTY
7654 CELL OPERATION DEGRADED LED display Stable red ( 7650); Blinking Red (7651) Instructions Replace the alarming module.
Related faults Baseband bus failure
46 Id:0900d80580a3004d DN0980455
4.24 Baseband bus failure
Fault ID and name 3020: EFaultId_BaseBandBusFailure Used in products FlexiBTS, LTE
Detecting unit FSM, FR
Source FSM, FR
Meaning The FlexiBTS has detected an abnormal operation or a failure in the BTS internal baseband bus. The failure cannot be attributed to a specific module but there are several possible fault sources.
State Start / Cancel
Unit status N/A
Unit status attributes
Effect Depending on the reported alarms, the fault situation might have no impact on the operation (BASE STATION or CELL NOTIFICATION), the BTS capacity might have decreased (BASE STATION or CELL OPERATION DEGRADED, or CELL FAULTY), or the BTS might not be operational at all (BASE STATION FAULTY).
Reported alarms 7650 BASE STATION FAULTY
7651 BASE STATION OPERATION DEGRADED 7652 BASE STATION NOTIFICATION
7653 CELL FAULTY
7654 CELL OPERATION DEGRADED 7655 CELL NOTIFICATION
LED display N/A
Instructions Note: Perform the steps below in the listed order until the BTS fault disappears.
1. Check the other active BTS faults and act accordingly.
2. Check the cables between the System Module and RF Module.
3. Reset the RF Module and/or System Module, depending on the alarm source:
a. Reset the RF Module by blocking/unblocking it. b. Reset the System Module by blocking/unblocking it.
4. Replace the alarming RF Module.
5. If the System Module is the source or replacing the RF Module does not clear the fault situation, replace the alarming System Module.
DN0980455 Id:0900d80580a3004d 47 Related faults Baseband bus configuration of <x> was rejected
1811: EFaultId_BbBus_ConfFailedAl
Not able to synchronize baseband bus with <x> 1815: EFaultId_BbBus_SyncFailedAl
RF BB Bus Synchronization Error 1904: EFaultId_FrRfBbBusSynchError
RF BB Bus Configuration Error
1905: EFaultId_FrRfBbBusConfigError
RF BB Bus Connection Transmission Error 1906: EFaultId_FrRfBbBusConnTransError
BB bus reception error (summing device) 2016: EFaultId_Muksu_SMTimeOffAl
BB bus transmission error
2017: EFaultId_Muksu_SRx10b8bAl
BB bus message collision error 2018: EFaultId_Muksu_StxPortCollAl
Address mismatch in summing 2019: EFaultId_Muksu_SsubMmAl
48 Id:0900d80580a300c3 DN0980455
4.25 BB bus message in the wrong slot
Fault ID and name 2057: EFaultId_MuksuMsgInWrongSlotAl Used in products FlexiBTS
Detecting unit FCM, FCT
Source FSP, OptIF
Meaning Baseband bus message multiplexing slot for the message is not possible to be fulfilled.
State Start / Cancel
Unit status Out of order
Unit status attributes
Effect The BTS operation is degraded because some of the BTS resources are not available.
Reported alarms 7650 BASE STATION FAULTY
7651 BASE STATION OPERATION DEGRADED 7653 CELL FAULTY
7654 CELL OPERATION DEGRADED
LED display Stable Red (7650), Blinking Red (7651), Stable Red (7653, 7654) Instructions If RF is the source:
1. Check antenna mapping to the local cells in the commissioning file. 2. Check the cables between the System Module and RF Module. 3. RF block/unblock
4. BTS reset
5. Replace the alarming module.
If FSP is the source:
System Module reset should be performed. Related faults Baseband Bus failure
DN0980455 Id:0900d80580a300eb 49
4.26 BB bus reception error (summing device)
Fault ID and name 2016: EFaultId_Muksu_SMTimeOffAl
Used in products LTE
Detecting unit FCM, FCT
Source FSP, optIF
Meaning The master frame in the received baseband bus frame is not in the correct place related to the internally generated master frame pulse. Either the frame has been set into the wrong place (PI delay) or the data itself is in the wrong place.
State Start / Cancel
Unit status Out of order
Unit status attributes
Effect The connection to the associated link is lost. The data is partly/completely lost. The worst-case fault effect can expand further from the cell level. This fault can prevent the BTS from operation when the RF Module is needed for the required cell configuration. Fault is visible for the first radio in chain only. Fault 10 is sending for the other FRs, when pooling breaks because of lost sync. Reported alarms 7650 BASE STATION FAULTY
7651 BASE STATION OPERATION DEGRADED 7653 CELL FAULTY
7654 CELL OPERATION DEGRADED
LED display Stable red
Instructions 1. Check the cables between the System Module and the connected module.
2. Replace the unit that causes the alarm (System Module). Related faults Baseband Bus failure
50 Id:0900d80580a30039 DN0980455
4.27 BB bus transmission error
Fault ID and name 2017: EFaultId_Muksu_SRx10b8bAl
Used in products LTE
Detecting unit FCM, FCT
Source FCM, FCT
Meaning A decoding error has been detected in the baseband internal link. The data packet is lost, or the content is corrupted. This situation is also triggered when the links do not synchronize with each other.
State Start / Cancel
Unit status Out of order
Unit status attributes
Effect Data traffic to the connected RF Module is malfunctioning. BTS operation is faulty.
Reported alarms 7650 BASE STATION FAULTY
LED display Stable red
Instructions 1. Check the cables between the System Module and RF Module.
2. Reset the System Module.
3. Replace the alarming module (System Module). Related faults Baseband Bus failure
DN0980455 Id:0900d80580a30068 51
4.28 BFD $session down, egress, $sourceIP to $destinationIP
Fault ID and name 61606: BFD DOWN EgressUsed in products LTE
Detecting unit FTLB, FTIB, FSM, FTIF
Source BFD
Meaning The alarm is raised if the alarm is enabled, the BFD state of the session is not AdminDown and the BFD packet from the far end contains the diagnostic code = 'Control Detection Time Expired' AND no ingress alarm is present.
State Start / Cancel
Unit status Major
Unit status attributes
Effect The communication link between the BTS and the BFD peer is defective. No communication is possible.
Reported alarms 7665 BASE STATION TRANSMISSION ALARM
LED display Blinking red
Instructions Check the BFD configuration at local end.
52 Id:0900d80580a30067 DN0980455
4.29 BFD $session down, ingress, $sourceIP to $destinationIP
Fault ID and name 61605: BFD DOWN IngressUsed in products LTE
Detecting unit FTLB, FTIB, FSM, FTIF
Source BFD
Meaning The alarm is raised if the alarm is enabled, the BFD state for the session is not AdminDown and nevertheless no BFD packet is received at the local end during the detection time.
State Start / Cancel
Unit status Major
Unit status attributes
Effect The communication link between the BTS and the BTS peer is defective. Or the peer is defective. No communication is possible.
Reported alarms 7665 BASE STATION TRANSMISSION ALARM
LED display Blinking red
Instructions 1. Check the network between both BFD peers for physical link failures or mis-configurations.
2. Check if the BFD functionality in the peer is switched on and that the config-urations of the BFD peers match.
DN0980455 Id:0900d80580a30080 53
4.30 BFD group $bfdGrpId down
Fault ID and name 61022: BFD DOWN
Used in products LTE
Detecting unit FTLB, FTIB, FSM, FTIF
Source BFDGRP
Meaning The alarm is raised if the BFD service is not available anymore on the BTS for all BFD sessions belonging to that BFD group.
State Start / Cancel
Unit status Critical
Unit status attributes
Effect The communication link between the BTS and the BFD peer is defective. No communication is possible.
Reported alarms 7665 BASE STATION TRANSMISSION ALARM
LED display Stable red
Instructions 1) Check if the far end has BFD switched on.
2) Check cabling and network connections to the far end. Related faults BFD Session down in ingress direction for session $S
61605: BFD DOWN Ingress
BFD Session down in egress direction for session $S 61606: BFD DOWN Egress
54 Id:0900d80580a300b2 DN0980455
4.31 Boot configuration inconsistency detected
Fault ID and name 4102: EFaultId_BootConfigurationInconsistencyAl Used in products FlexiBTS, LTE
Detecting unit (FSMr2): FCM, (FSMr3): FCT
Source FSMr2: FCM, FSP MCU FSMr3: FCT
Meaning During SW update it was detected that configurations of active and passive SW in HW unit are same. Active and passive SW configuration are compared: - before SW download - during SW activation before active and passive SW switch - during start-up
State Start
Unit status Out of order
Unit status attributes
Effect Newly downloaded SW will overwrite active SW. Therefore, SW download and activation are not allowed. Currently active SW is still running.
Reported alarms 7650 BASE STATION FAULTY
7651 BASE STATION OPERATION DEGRADED LED display stable red (7650) , blinking red (7651)
Instructions Replace the faulty unit. Related faults
DN0980455 Id:0900d80580a300e0 55
4.32 BTS blocked
Fault ID and name 50: EFaultId_BTSBlockedAl Used in products FlexiBTS, LTE
Detecting unit FCM/FCT
Source FCM (FSMr2), FCT (FSMr3)
Meaning The BTS is blocked with BTS Site Manager. The purpose is to avoid fault indi-cations that might be raised during a BTS maintenance task.
State Start
Unit status Working
Unit status attributes
Effect The BTS does not send faults to the network management system (NMS) when the BTS is blocked. The fault cancellations are sent to the NMS. All cells are disabled.
Reported alarms 7650 BASE STATION FAULTY
LED display Stable green
Instructions To cancel the fault, unblock the BTS. Unblocking the BTS causes a Site Reset (FSMr3) or BTS Reset (FSMr2).
56 Id:0900d80580a30047 DN0980455
4.33 BTS config error (Not enough HW for LCR)
Fault ID and name 1868: EFaultId_NotEnoughHwForLcrAl
Used in products LTE
Detecting unit FCM
Source LCR
Meaning RF Module cannot serve all cells commissioned to the RF module. Or Not enough FSP resources for commissioned cells during BTS startup phase.
State Start / Cancel
Unit status Out of order
Unit status attributes
Effect The BTS capacity drops.
Reported alarms 7653 CELL FAULTY
LED display Stable green
Instructions RF module:
Replace the single or dual PA RF module with a triple PA RF module. Alternatively, recommission the BTS with fewer cells.
FSP:
1.Block & unblock the system module
2.If that does not help, replace the system module
Related faults Configuration error: <x>
DN0980455 Id:0900d80580a300b0 57
4.34 BTS configuration not supported
Fault ID and name 4097: EFaultId_BtsConfNotSupportedAl Used in products FlexiBTS, LTE
Detecting unit FCT
Source FSP
Meaning FSP does not support requested BTS configuration.
State Start
Unit status Out of order
Unit status attributes
Effect BTS baseband processing power is decreased. If all FSPs are faulty BTS is not operational.
Reported alarms 7650 BASE STATION FAULTY
7651 BASE STATION OPERATION DEGRADED LED display Stable red (7650), Blinking red (7651)
Instructions Note! Perform the steps below in the listed order until the fault disappears. 1. Change BTS configuration.
2. Reset BTS.
Related faults Configuration error: <x>