Schneider Electric- CS&P – System Terminology – E01 2
Electric Network Definition
Primary Devices
Protections
Datapoints
• Content
Electric Network Definition
Primary Devices
Protections
Schneider Electric- CS&P – System Terminology – E01 4
Distribution
Transmission
Electric Network is a Hierarchy of Voltage
Transport 600-400kV
400
kV
400
400
kV
kV
400
kV
Distribution 110-90 kV
90 kV
90 kV
90 kV
90 kV
Repartition 220kV
225 kV
225 kV
225 kV
225 kV
Delivery 2-6-20kV
6
6
6
6----20 kV
20 kV
20 kV
20 kV
Bi-directional Mesh
Directional Antenna
Antenna / Annealing
Carry Electricity from Producers to Consumers
Producer
Industrial
Consumer
Domestic
Consumer
• What is Electric Network
Schneider Electric- CS&P – System Terminology – E01 6
Substation is a node in the grid electric network
Substation is linked to one voltage level
1.
Dispatch power flow on
branch/lines
2.
Allow maintenance
(line/device)
3.
Select/eliminate fault in
only one section
4.
Mesh network (stability)
• What is Substation
• System Terminology
SITE
SUBSTATION
VOLTAGE
VOLTAGE
VOLTAGE
VOLTAGE
LEVEL
LEVEL
LEVEL
LEVEL
BAY
MODULE
Schneider Electric- CS&P – System Terminology – E01 8
• Content
Electric Network Definition
Primary Devices
Protections
• Primary Device: Bus Bar
Feeder => interface to Voltage level (line branch, transformer)
Bus Bar => Backbone to dispatch power between feeders
Schneider Electric- CS&P – System Terminology – E01 10
• Primary Device: Circuit Breaker
Make / Break Current then Power flow
Operate under Nominal or Faulty condition
- exploitation
• Primary Device: Bar / Line Isolator
Bar Isolator : Isolate CB / Bar (maintenance/exploitation)
Line Isolator : Isolate CB / Line (line maintenance)
Schneider Electric- CS&P – System Terminology – E01 12
• Primary Device: Earth switch Isolator
• Primary Devices list
Feeder (line)
Bus bar
Circuit Breaker
Bar Isolator
Line Isolator
Earth Isolator
• Transformer
• Generator
• Motor
• Capacitor Bank
• Reactor
M
G
Schneider Electric- CS&P – System Terminology – E01 14
Isolation
• Switching Devices Kind
Breaking
I
N
V
N
V
Peak
X
X
X
X
-
--
-X
-X
-
-X
X
X
X
X
--
-
X
X
-X
X
X
X
X
Roughly : I
CC
=10 I
N
Roughly : V
Peak
= 2 V
N
between phase, phase to earth
up to 6 V
N
(thunder peak 50ms)
Breaker
Isolator
Switch
Switch
disconnector
Contactor
Breaker
Isolator
I
CC
4I
N
• Measurement Transformer CT/VT
Schneider Electric- CS&P – System Terminology – E01 16
• Why measurement CT/VT
CT/VT : Lower Primary Values (HV) to Secondary Values (LV)
• Galvanic Isolation (no current between HV / LV)
• Measurement Reduction
120 Volts
120 Volts
120 Volts
120 Volts
3 000 Amps
1
1
1
1 Amp
Amp
Amp
Amp
• Voltage Transformer Overview (1)
Description (1)
245 kV
245 kV
245 kV
245 kV
100 V
100 V
100 V
100 V
Schneider Electric- CS&P – System Terminology – E01 18
• Voltage Transformer Overview (2)
Description (2)
P1
P2
S1
S2
N
N
N
N
p
p
p
p
.U
.U
.U
.U
ssss
= N
= N
= N
= N
ssss
.U
.U
.U
.U
p
p
p
p
• Current Transformer Overview (1)
Description (1)
245 kV
245 kV
245 kV
245 kV
3000 spires
1 A
1 A
1 A
1 A
1 A
1 A
1 A
1 A
3000 A
3000 A
3000 A
3000 A
3000 A
3000 A
3000 A
3000 A
Schneider Electric- CS&P – System Terminology – E01 20
• Current Transformer Overview (2)
Description (2)
P1 P2
S1 S2
N
N
N
N
p
p
p
p
.I
.I
.I
.I
p
p
p
p
= N
=
=
=
N
N
N
ssss
.I
.I
.I
.I
ssss
Substation
•
Site Partition => Local/Remote substation
•
Substation Control Uniqueness
•
(nb=1) The Business DB (except Cascade)
Voltage Level
•
Association of Bus Bars for Auto Volt. Regul.
•
Often only one BB (nb 4-5-x)
Bay
•
ANSI => 1 CB with associate circuits & protections
•
Association of switchgears/transformers & functions
•
Local/Remote Bay, SBMC, Bay Control Uniqueness
•
Special (coupler, section, feeder, transformer)
•
Often Generic (more easy)
•
Bay belongs to only one C264
Module
•
Primary Electric Device, ANSI functions, Group of DP
•
Special (CB, disconnector, transformer, AR, Sync)
•
Often Generic (DPS/DPC association possible)
Datapoint
•
Real Time information (95% electric)
•
At any level
Schneider Electric- CS&P – System Terminology – E01 22
SITE
SUBSTATION
SUBSTATION
VOLTAGE
LEVEL 1
VOLTAGE
LEVEL 2
BAY FEEDER 1
BAY TRANSFO
BAY FEEDER 2
SW 1
TR 1
SW 2
CB 1
Position
Control
TPI
Control
Position
Control
VOLTAGE
LEVEL N
• SCE Preview
• Content
Electric Network Definition
Primary Devices
Protections
Schneider Electric- CS&P – System Terminology – E01 24
Control
=> dispatch energy
=> keep service (continuity, quality)
=> maintenance operation
Protection => Fault (Shortcut)
•
Short circuit implies unbalancing, voltage drop…
•
Isolate Faulty section
•
Save device from destruction
•
Secure installation
fire / explosion (arc)
people security (insulation)
Protection => Exploitation (Overload)
•
Unbalanced exploitation
•
Damaging isolation
•
Degrading devices
M
M
M
M
Measurement
Measurement
Measurement
Measurement
C
C
C
C
Computer
Computer
Computer
Computer
P
P
P
P
Protection
Protection
Protection
Protection
S
S
S
S
System
System
System
System
• MiCOM Range
H
H
H
Schneider Electric- CS&P – System Terminology – E01 26
Y
Y
Y
Y
Hardware platform
Hardware platform
Hardware platform
Hardware platform
(e.g. 20
(e.g. 20
(e.g. 20
(e.g. 20 serie
serie
serie
serie))))
X
X
X
X
Application
Application
Application
Application
(e.g.: 1=
(e.g.: 1=overcurrent
(e.g.: 1=
(e.g.: 1=
overcurrent
overcurrent
overcurrent))))
P
P
P
P
Protection
Protection
Protection
Protection
Z
Z
Z
Z
Options
Options
Options
Options
(additional hard, threshold..)
(additional hard, threshold..)
(additional hard, threshold..)
(additional hard, threshold..)
• MiCOM Naming Pxyz for Protection
30 Series
30 Series
30 Series
30 Series
20 Series
20 Series
20 Series
20 Series
Hardware platform
Hardware platform
Hardware platform
Hardware platform
40 Series
40 Series
40 Series
40 Series
Schneider Electric- CS&P – System Terminology – E01 28
P200 Motor
P200 Motor
P200 Motor
P200 Motor
P300 Generator
P300 Generator
P300 Generator
P300 Generator
P400 Distance
P400 Distance
P400 Distance
P400 Distance
P500 Line Differential
P500 Line Differential
P500 Line Differential
P500 Line Differential
P100
P100
P100
P100 Overcurrent
Overcurrent
Overcurrent
Overcurrent
P600 Transformer Differential
P600 Transformer Differential
P600 Transformer Differential
P600 Transformer Differential
P700 Bars Differential
P700 Bars Differential
P700 Bars Differential
P700 Bars Differential
P800 Auxiliary
P800 Auxiliary
P800 Auxiliary
P800 Auxiliary
P900 Voltage/Frequency
P900 Voltage/Frequency
P900 Voltage/Frequency
P900 Voltage/Frequency
• MiCOM Naming Px__
Substation:
• MiCOM P Application
M GP520
P520
P520
P520
ou P540
ou P540
ou P540
ou P540
P540
P540
P540
P540
P440
P440
P440
P440
P340
P340
P340
P340
P140
P140
P140
P140
P120
P120
P120
P120
P630
P630
P630
P630
P220
P220
P220
P220
P240
P240
P240
P240
P120
P120
P120
P120
P845
P845
P845
P845
T&DP920
P920
P920
P920
P940
P940
P940
P940
P200 Motor
P200 Motor
P200 Motor
P200 Motor
P300 Generator
P300 Generator
P300 Generator
P300 Generator
P400 Distance
P400 Distance
P400 Distance
P400 Distance
P500 Line Differential
P500 Line Differential
P500 Line Differential
P500 Line Differential
P100
P100
P100
P100 Overcurrent
Overcurrent
Overcurrent
Overcurrent
P600 Transformer Differential
P600 Transformer Differential
P600 Transformer Differential
P600 Transformer Differential
P700 Bars Differential
P700 Bars Differential
P700 Bars Differential
P700 Bars Differential
P800 Auxiliary
P800 Auxiliary
P800 Auxiliary
P800 Auxiliary
P900 Voltage/Frequency
P900 Voltage/Frequency
P900 Voltage/Frequency
P900 Voltage/Frequency
Schneider Electric- CS&P – System Terminology – E01 30
• Content
Electric Network Definition
Primary Devices
Protections
REAL TIME DATA = DATAPOINTS
Several KIND of DP
BINARY
INPUTS
MEASUR.
&
COUNTERS
OUTPUTS
IEC61850
SPS_ST , SPC_ST
DPS_ST, DPC_ST
INS_ST
MV, WYE_MX, DEL
BST_ST
BCR_ST
SPC_CO
DPC_CO,BST_CO
APC_SP
SPS
Single Point Status
DPS
Double Point Status
MPS
Multiple Point Status
MV
Measurement Value
TPI
Tap Position Indication
SCT
Single CounTer
DCT
Double CounTer
SPC
Single Point Control
DPC
Double Point Control
SP
SetPoint
Schneider Electric- CS&P – System Terminology – E01 32
Common Invalid
Unknown (IED), Self-Check Fault (Hard)
+DPS invalid
Jammed (00) Undefined (11)
+MV, xCT invalid
Open Circuit, Undefined, OverRange
Supervision
Status/Value
Quality
FSS
Force (auto/Manu) an Invalid DP
Suppress (Make DP invalid)
Substitute (Force the Status/Value of DP)
Threshold
For Alarms / Events
L,LL,LLL, H, HH, HHH with hysteresis
SPS
Reset/Set
Valid / FSS / Invalid
DPS
Open(01)/Close(10)
Valid / FSS / Invalid
MPS
State16
Valid / FSS / Threshold / Invalid
MV, TPI, DM
Value (Float32)
Valid / FSS / Threshold / Invalid
SCT, DCT
Integer
SPC, DPC, SP
Kind
D
irect
E
xecute
S
elect
B
efore
O
perate
One Shot
Selection / Wait(cancel) / Execute
Medium/Low Volt.
HV + Control Uniqueness => order run Bay
Where
Direct Execute
Select Before Operate
1) SBUS/C264
DE
SBO
Select Open/Close
Execute Open/Close
2) Supervision
OI
DE, SBO like pop-up
SBO pop-up
SCADA
DE, SBO
DE, SBO
3) IED
DE, SBO
DE, SBO
Schneider Electric- CS&P – System Terminology – E01 34