UNITED STATES ENVIRONMENTAL PROTECTION AGENCY Washington, D.C. 20460

NPDES Compliance Inspection Report

Form Approved

OMB No. 2040-0003 Approval Expires 7-31-85

Section A: National Data System Coding

Transaction Code NPDES yr/mo/day Inspec. Type Inspector Fac Type 1 N 2 5 3 A R 0 0 4 9 8 7 5 11 12 0 6 0 7 0 5 17 18 R 19 S 20 2

Remarks

A F I N # 6 0 - 0 1 8 3 2 P U L A S K I C O U N T Y

Inspection Work Days Facility Evaluation Rating BI QA ---Reserved---

67 69 70 71 72 73 74 75 80

Section B: Facility Data

Entry Time /Date 1030 07-05-06

Permit Effective Date 12/1/02

Name and Location of Facility Inspected (For industrial users discharging to POTW, also include POTW name and NPDES permit number)

Philrod Acres Mobile Home Park

1804 Hwy. 89 West

Cabot, AR 72023 Exit Time/Date

1145 07-05-06

Permit Expiration Date 11/30/07

Name(s) of On-Site Representative(s)/Title(s)/Phone and Fax Number(s) Mr. Currier/ owner’s son/ 501-988-2120

Contacted

Yes No X

Name, Address of Responsible Official/Title/Phone and Fax Number B. J. Currier, owner 501-988-2120

1804 Hwy. 89 West Cabot, AR 72023

Other Facility Data

Section C: Areas Evaluated During Inspection

(S = Satisfactory, M = Marginal, U = Unsatisfactory, N = Not Evaluated)

N Permit N Flow Measurement N Operations & Maintenance N CSO/SSO

N Records/Reports N Self-Monitoring Program N Sludge Handling/Disposal N Pollution Prevention S Facility Site Review N Compliance Schedules N Pretreatment N Multimedia

S Effluent/Receiving Waters N Laboratory N Storm Water U Other: FCB/NH3-N/cBOD Samples Section D: Summary of Findings/Comments (Attach additional sheets if necessary)

On 07/05/06 Inspector Lisa Jacobs and I performed a recon sampling inspection at the above facility. Samples for FCB, NH3-N,

cBOD,COD, pH, and DO were collected at four sites. Sample 1 was from upstream of bridge and discharge pipe, Sample 2 was from pool downstream of bridge, Sample 3 was from effluent pipe, and Sample 4 was from downstream pool near red house. Also the plant was inspected and found to have been maintained in accordance with the permit. Effluent samples revealed two violations: pH of 4.66 and NH3-N of 11.2. See attached photos and sample results for further details. No flow was found in the stream at the time of sampling.

Name(s) and Signature(s) of Inspector(s) Zachary Watson

Agency/Office/Telephone/Fax

ADEQ/ Little Rock/501-682-0658/501-682-0910

Date 07/05/06

Signature of Reviewer Agency/Office/Phone and Fax Numbers

Date

(2)

Arkansas Department of Environmental Quality (ADEQ)

Official Photograph Sheet

Location: Phil Rod Acres – Blue Branch of Bayou Two Prairie

Photographer: Zachary Watson Witness: Lisa Jacobs

Photo # 1 Of 4 Date: 07/05/06 Time: 1037

Description: Sample 1 Location

Photographer: Zachary Watson Witness: Lisa Jacobs

Photo # 2 Of 4 Date: 07/05/06 Time: 1050

(3)

Arkansas Department of Environmental Quality (ADEQ)

Official Photograph Sheet

Location: Phil Rod Acres – Blue Branch of Bayou Two Prairie

Photographer: Zachary Watson Witness: Lisa Jacobs

Photo # 3 Of 4 Date: 07/05/06 Time: 1107

Description: Sample 3 Location

Photographer: Lisa Jacobs Witness: Zachary Watson

Photo # 4 Of 4 Date: 07/05/06 Time: 1100

(4)

Company Name

Company Address

Phone: Fax:

CERTIFICATE OF ANALYSIS

-Attn: Phone: Ext:

FAX: Our Lab#: 2006-1972

Your Sample ID: Phil Rod Acres 1

Sample Type: Report Date: 10-Jul-06

Test Group Test Result Units Analysis Date

CBOD5

Carbonaceous biochemical oxygen 8.30 mg/L 7/5/2006

demand COD

Chemical oxygen demand 65.2 mg/L 7/5/2006

FC-MF

Fecal coliform by membrane filter H 3900 cfu/100 ml 7/5/2006

NH3-N-ISE Ammonia as nitrogen 1.83 mg/L 7/7/2006 FIELD Dissolved oxygen 7.43 mg/L 7/5/2006 Field pH 6.09 SU 7/5/2006 Page 1 of 1

(5)

Company Name

Company Address

Phone: Fax:

CERTIFICATE OF ANALYSIS

-Attn: Phone: Ext:

FAX: Our Lab#: 2006-1973

Your Sample ID: Phil Rod Acres 2

Sample Type: Report Date: 10-Jul-06

Test Group Test Result Units Analysis Date

CBOD5

Carbonaceous biochemical oxygen 7.63 mg/L 7/5/2006

demand COD

Chemical oxygen demand 58.9 mg/L 7/5/2006

FC-MF

Fecal coliform by membrane filter >6000 cfu/100 ml 7/5/2006

NH3-N-ISE Ammonia as nitrogen 8.04 mg/L 7/7/2006 FIELD Dissolved oxygen 6.36 mg/L 7/5/2006 Field pH 6.14 SU 7/5/2006 Page 1 of 1

(6)

Company Name

Company Address

Phone: Fax:

CERTIFICATE OF ANALYSIS

-Attn: Phone: Ext:

FAX: Our Lab#: 2006-1974

Your Sample ID: Phil Rod Acres 3

Sample Type: Report Date: 10-Jul-06

Test Group Test Result Units Analysis Date

CBOD5

Carbonaceous biochemical oxygen 1.74 mg/L 7/5/2006

demand COD

Chemical oxygen demand 38.1 mg/L 7/5/2006

FC-MF

Fecal coliform by membrane filter ~31 cfu/100 ml 7/5/2006

NH3-N-ISE Ammonia as nitrogen 11.2 mg/L 7/7/2006 FIELD Dissolved oxygen 4.98 mg/L 7/5/2006 Field pH 4.66 SU 7/5/2006 Page 1 of 1

(7)

Company Name

Company Address

Phone: Fax:

CERTIFICATE OF ANALYSIS

-Attn: Phone: Ext:

FAX: Our Lab#: 2006-1975

Your Sample ID: Phil Rod Acres 4

Sample Type: Report Date: 10-Jul-06

Test Group Test Result Units Analysis Date

CBOD5

Carbonaceous biochemical oxygen 2.42 mg/L 7/5/2006

demand COD

Chemical oxygen demand 40.7 mg/L 7/5/2006

FC-MF

Fecal coliform by membrane filter ~14 cfu/100 ml 7/5/2006

NH3-N-ISE Ammonia as nitrogen 3.92 mg/L 7/7/2006 FIELD Dissolved oxygen 3.12 mg/L 7/5/2006 Field pH 6.51 SU 7/5/2006 Page 1 of 1

References

Related documents

9 While MSCs have the potential to differentiate to endothelial and skeletal muscle cell types, the low MSC survival rate following delivery in vivo suggest that

The answer is no longer cut and dry, as intangible assets can cover a lot more than we may think at first: patents, trademarks and utility models, but also intellectual property

Other operations in the plan are executed in parallel by either one of the two sets of servers, hence the column executions shows 16, which is equal to the DOP of our query..

This template may also be useful as a consultation document that community members can use, during the consultation and plan development stage. It will be provided electronically

To better analyze the performance issues for each algorithm (HiT-MDS, VPD-MDS, Glimmer, and CFMDS) we present the results obtained on the same GPU hardware for the same data sets..

Its objective is to organise the internal, external and public relations of EVEL, to create and maintain a good cooperation environment between the members and

This Phase 1 of CMEP involves construction of a new intermediate Compressor Station 312 located on NGPL’s Gulf Coast Mainline system in Livingston County, IL that increases NGPL’s