This document provides additional assistance with wiring your Extron IP Link enabled product to your device. Different components may require a different wiring scheme than those listed below.

For complete operating instructions, refer to the user’s manual for the specific Extron IP Link enabled product or the controlled device manufacturer supplied documentation.

Minimum Software and Firmware Requirements:

IP Link Compiler

IP Link

Firmware GC Version

1.6.0 1.17 3.5.1

Version History:

Driver

Version Date Notes

8 9/24/2103 Extron Certified. Tested on QSE-CI-NWK-E. Updated driver to be compatible with GC 3.5.1

7 1/3/2012 Fixed delay issue when sending commands. 6 12/4/2012 Added model. Quantum System.

5 9/7/2011 Extron Certified. Added models QSNE-2DAL-D and QSN-4S16-S. Tested on both models.

4 5/27/2011 Extron Certified. Added model QSN-2ECO-S. Tested on QSN-2ECO-S. 3 10/1/2010

Extron Certified. Tested on QSE-CI-NWK-E system with a Grafik Eye, two seeTouch QS panels, and a Sivoia QS shade. Added models Sivoia QS and seeTouch QS. Added Button, Button Mode, Device select and Shade Position. 2 8/2/2010 Modified the driver to accept serial numbers

1 2/18/2010 Initial version.

Device Specifications:

Device Type: Lighting Control Manufacturer: Lutron

Firmware Version: Grafik Eye QS - CODE:5.30, BOOT:4.1, HW:2.1 QSE-CI-NWK-E - CODE:7.15, BOOT:2.9, HW:1.0 Sivoia QS - CODE:0.100, BOOT:2.9, HW:8.6 seeTouch QS - CODE:2.50, BOOT:2.3, HW:1.1 QSN-2ECO-S- CODE:5.17, BOOT:0.3, HW:3.1 QSNE-2DAL-D - CODE:5.8, BOOT:5.1, HW:3.1 QSN-4S16-S - CODE:5.15, BOOT:1.5, HW:1.1

Model(s): Grafik Eye QS, QSE-CI-NWK-E, Sivoia QS, seeTouch QS, QSN-2ECO-S, QSNE-2DAL-D, QSN-4S16-S, Quantum System

(2)

Page 2 of 6 Control Commands & States:

Area Level7 0 to 100 in steps of 1

Area Level (Step) 7 Up Down Stop

Area Scene7 0-32

Area Select4 1-200

Button 1-100

Button Mode1 Execute

Stop

Daylight Automation7 Active Inactive

Device Select 1-3

Fade 1-592

1-10 Min

15 Min

20 Min

Select

Integration ID7 1-200

Master Level (Step)1 Up Down Stop

Output Level7 0 to 100 in steps of 1

Output Level (Step) 7 Up Down Stop

Preset Scene 1-16 Off

Serial Digit 1-8 0-9 A-F

Shade Group Level7 0 to 100 in steps of 1

Shade Group Level (Step) 7 Up Down Stop

Shade Group Preset7 1-30

Shade Position 0-100

Zone Select3 1-100

Level 0-100 in steps of 1

Driver Notes:

 Zone Select includes Fade Time; default Fade Time is 1 second.  The Configuration Notes on pg.3 explain how to set up the driver.

(3)

Page 3 of 6 1

This command has press/release functionality. The stop command is used for configuration purposes

only.

2

This value is in seconds.

3

Zones 25-100 are for the QSN-2ECO-S. QSN-2ECO-S. Zones 1-32 are for the QSNE-2DAL-D, and

zones 1-4 are for the

QSN-4S16-S.

4

When using the QSN-2ECO-S, select an area before sending the preset scene command. Only areas 1-32

will work on the QSNE-2DAL-D and 1-4 on the

QSN-4S16-S.

7

Will only work with Quantum System.

Status Available:

Connection Status Connected Disconnected

Area Scene 0-32

Daylight Automation Active Inactive

Shade Group Preset 1-30

Output Level 0 to 100 in steps of 1

Preset Scene 1-16 Off

Level 0-100

Shade Position 0-100

(4)

Page 4 of 6 Configuration Notes:

1.

Use the Device Select command to select the type of device being controlled according to the

following table:

Device Select

Device

1

Grafik Eye QS

2 QS

Shade

3 seeTouch

QS

4 QSN-2ECO-S

5

QSN-4S16-S

6

QSNE-2DAL-D

2.

Next use Serial Digit 1-8 in the driver to match the serial digit on the device that you are trying to

control. This will have to be configured for every device in the system. For example, if the serial

number on a Grafik Eye is

00AC123D, then you will configure the Serial Digits in the driver as the following:

Serial Digit 1 will be 0

Serial Digit 2 will be 0

Serial Digit 3 will be A

Serial Digit 4 will be C

Serial Digit 5 will be 1

Serial Digit 6 will be 2

Serial Digit 7 will be 3

Serial Digit 8 will be D

Note: If you are going to control/monitor another device, such as a QS Shade, then you also need

to configure the Serial Digits to match that device before controlling it and use the correct Device

Select in the driver.

3.

In addition to the first two steps, to control a seeTouch QS keypad or the front panel of a Grafik

Eye QS, you must select the button in the driver that corresponds with the buttons on the device.

See Appendix A in integration protocol or contact manufacturer to see what button number in the

driver corresponds to what button on the device.

4.

Light intensity levels on a Grafik Eye QS or

QSN-2ECO-S, QSNE-2DAL-D, or QSN-4S16-S

can be

changed by using the Level command in the driver. In order to change Level command, you must

select Zone Select and Fade commands. Level Status will only show level of currently selected

zone.

(5)

Page 5 of 6 Configuration Notes for Quantum System:

1.

Use the Device Select command to select the type of device being controlled according to the

following table:

Device Select

Device

7

Quantum System

2.

Next use Integration ID 1-200 in the driver to match the device that you are trying to control. This

will have to be configured for every device in the system.

(6)

Page 6 of 6 Ethernet Driver Configuration Description:

Please refer to user manual for settings and changes to the network communication parameters such as: User Name, Passwords.

Notes for the Device: Network communication:

When configuring the Ethernet driver, be sure device settings match that of the GC configuration. Multi-connection can only work with 2 devices; the second user name is nwk2.

Port Type: Ethernet

Logon Credentials Supported:

Yes

Default User Name: nwk

Default Password:

N/A

Default Port: 23

Multi-Connection Capable:

Yes

References

Related documents

Guy pdf and home office questionnaire pdf templates, free printable secret santa form of bit quicker to make a memorable gift.. Illustrations of note the secret santa pdf and a

Such a collegiate cul- ture, like honors cultures everywhere, is best achieved by open and trusting relationships of the students with each other and the instructor, discussions

(Instance ID Tags) may be assigned to DSP blocks, and used in lieu of Instance ID numbers within NTP (Nexia Text Protocol) command strings.. Instance ID Tags may be up to

In order for this driver to work with the SoundStructure, it is necessary to configure the virtual names to match the driver within the SoundStructure Studio available for free

3Kundenzone Airbnb Alinma Bank - فرصم Amazon American Bank – Mobile Banking Anson Bank & Trust e-zMobile Banking Apothekerbank Ärztebank MobileBanking Bank Austria BAWAG

The time lag in the two waves and their interaction control the deposition of the sus- pended sediments carried by the release. In particular the hydrodynamic signal travels

In a Multiroom System with a Re:system M100 Slave device, the slave device also requires its own M202 Ethernet interface as well as the main device). However, only the IP

In order to configure an IPv4 over IPv6 tunnel, you first need to create an IP tunnel interface; consequently you need to enter “add device tnip <tunnel identifier>” in the