M

06 / 2003

Specifi cations

Positioning Key-Features Optional components

(2)

Description

Server-Racks with 41U, 37U and 23U

Highlights

• With perforated doors front and rear for optimal airflow.

• Optimized 19“ server slide rail kit

for a variable installation of the MAXDATA PLATINUM servers

• Server-Rack base with integrated

withdrawable tilt protector (up to 600 kg) and wheel base with levelling feets • On the top of the rack is a break-out hole

(75 mm) for safe entry cabeling. • Earth set complete

• Lock set complete

(3)

Positioning

The MAXDATA PLATINUM Server-Racks are particularly made for the MAXDATA PLATINUM server series. This results in the customer saving time and effort when installing components. Of course the devices from other manufacturers can installed, when they uses the MAXDATA standard 19” rack mounting.

The rack base is equipped with 4 wheels with which the rack can be moved problem free. It also has a withdrawable tilt protector which enables rack components to be safely withdrawn preventing the rack from toppling over. This can withstand a maximum weight of 600 KG. On the four corners are unscrewable levelling feet which provide a stable, level rack on uneven floor surfaces.The rack has been designed in such a way that no additional ventilation is required nor does it need it’s own air conditioning. From the fi ne perforations in the front door, the air can flow through the rack exiting via the perforated rear doors.

The hole profi les on each side of the rack are perfectly coordinated with all MAXDATA platinum servers, APC UPS’s, Overland tape libraries, MAXDATA external disk arrays and MAXDATA MAXVIEW. This results in the customer saving time and effort when installing components. At the same time the distances of the hole raster profi le to the front and back doors is designed so that there is suffi cient space for the MAXDATA 1 U MAXVIEW monitor-keyboard drawer and all related cabling.

(4)

Supplied with

• 1 x Basic frame • 4 x 19“ mountig frame

• 2 x Slide panels with quick locking mechanism • 1 x Top cover

• 1 x Front door, sheet steel with perforation, optimal airflow • 1 x Rear door, sheet steel with perforation, optimal airflow

• 1 x Wheel base with tilting protection up to 600 kg and levelling feet • 1 x Earth set complete

• 1 x Lock set complete for front and rear door • 1 x Lock set complete for side panels

(5)

Material

Installation extrusion Vertical extrusion, aluminium Corner connectors Diecast aluminium

Visible cover surfaces Sheet steel, zinc galvanised Doors Sheet steel, opening angle 180°

Dimensions IEC 297-3 and IEC 917

Height 23U / 37U / 41U (1U = 44,45 mm) Width 482,6 (19“)

Depth max. 760 mm

Out dimensions

23U (Height x Width x Depth) 1300 x 600 x 900 mm 37U (Height x Width x Depth) 1920 x 600 x 900 mm 41U (Height x Width x Depth) 2100 x 600 x 900 mm

space offer

Useful surface 82 % of the base rack Ranking area Front min. 73 mm

Weight

23U 72 kg

37U 105 kg

41U 120 kg

Placing

stationarely On levelling feet mobile With base and brakes

(6)

Finish / colour

Basic frame blank

Door black, RAL 9011

Visible cover surfaces powder-coated structure, black, RAL 9011

Static loading

Stationarely on levelling feet 5000 N Mobile on wheels 3000 N

Heat dissipation (closed)

Energy dissipation up to 500 W

Regulations

Shock and vibration yes test MIL-STD 810 E

IP-test in accordance yes with IEC 529

UL-test 1244 yes NEMA 12 standard yes EMV-absorbtion yes MIL-STD 285

(10 MHz - 30 MHz) and VG 95373 part 15 (30 MHz - 1 GHz)

Shock and vibration yes test ETS 300019

Earthquake test yes Bellcore (NEBS)

TR-NWT 000063 zone 4 yes earthing VDE 0 100 T 540

(7)

Plug strip 9-way

Plug strip 7-way

Material / finish Housing: closed sheet steel

zinc galvanised, powder-coated structure

Plastic parts: Polyamid PA 6 (UL 94 V0), recycleable Interior: continuos bus bars, brass

Inlet: PVC

Regulatory CE marking in accordance low voltage guideline 73/23/EWG, EMV guideline 89/336/EWG, VDE-certificate

Colour combination Plasic parts RAL 7035 lightgrey Maximum voltage 250 VAC / 16 A

Supplied with 1 x plug strip 2 x attaching brake

Note International plug sockets such as Switzerland, USA, UK, France are availble. Please indicate when

ordering which you require.

IEC 60320 (male) - plug strip 9-way

IEC 60320 (male) - plug strip 6-way

Material / finish Housing: closed sheet steel

zinc galvanised, powder-coated structure

Plastic parts: Polyamid PA 6 (UL 94 V0), recycleable Interior: continuos bus bars, brass

Inlet: PVC

Regulatory CE marking in accordance low voltage guideline 73/23/EWG, EMV guideline 89/336/EWG, VDE-certificate

Colour combination Plasic parts RAL 7021 black/grey Maximum voltage 250 VAC / 16 A

Regulatoray for IEC 320 3-way VDE, UL, CSA, SEV, SEMKO IEC 60320 - plug stip

Supplied with 1 x plug strip 2 x attaching brake

Optional

components

(8)

Intermediate shelf, fi xed

Dimension (W x D x L) 430 x 740 x 600 mm

Material / finish Steel plate 1.0 mm, electrolytical galvanised, powder coated structure

Colour RAL 9011 black Loading 500 N static Supplied with 2 x assembly rails

1 x shelf installation kit

Intermediate shelf, sliding rails

Dimensions (W x D x L) 430 x 740 x 600 mm

Material / finish Steel plate 1.0 mm, electrolytical galvanised, powder coated structure

Colour RAL 9011 black Loading 500 N static Supplied with 2 x telescopic rails

2 x carrier rails 1 x shelf installation kit

Universal card frame rail, screwable

Dimensions (D x L) 740 x 686 mm

Material / finish Aluminium extruded section 2.0 mm, blank Loading 500 N static

Supplied with 2 x module rails

Blanking plate 1 / 2 / 3 Units

Material / surface Steel plate 1.5 mm

Optional

components

(9)

Cable-run plate

Dimensions (W x H) 19“ x 1U

Material / finish Front panel steel sheet 1,5 mm powder coated RAL 9011, black Cable-runs 55 x 22 mm, plastic

Supplied with 1 x 19“ front plate 5 x cable rings

Cable-run ring

Supplied with 5 x cable-run rings installation kit

Optional

components

(10)

Optional

components

MAXVIEW KVM console drawer

Dimensions (H x W x D) 1U x 19“ x 67,5 cm – 80,5 cm (for racks with 90 cm depth) Colour black

Keyboard PS/2, Windows Keyboard with 105 keys + numeric block

International versions German keyboard Optional available: - German (Germany) - German (Switzerland) - English (UK) - English (USA) - Japanese

Touchpad Touchpad with 2 keys

KVM-Switch Server-console-connection 1:1 Server-console-connection 8:1

cascadeable up to 9 switches to connect 64 servers

Keyboard interface PS/2 (optional USB) Mouse interface PS/2 (optional USB) Monitor interface VGA, 15D-SUB Power supply 100-230 V / 50-60 Hz

Panel 15,1 Zoll TFT, 30,4 x 22,8 (cm) Phys. resolution 1024 x 768 @60/70/75 Hz Contrast ratio (typ.) 350:1

Brightness (typ.) 200 cd/m² max. colour 16,7M (8 bit)

Management On-Screen-Display (OSD) Input signal RGB analog, H/V separate Power management VESA DPMS compatible

(11)

Contact

Communication-Center

01805 - 003384

References

Related documents

Agricultural Efficiency of Rice Farmers in Myanmar: A Case Study in Selected Areas Nay Myo Aung* September 2011 September 2011 Abstract: This paper try to analyze unique data set

Today, France and Germany are not just partners in European integration, but also competitors on political and economic terms. 8 Not only are France and Germany the two

The underlying pressures in Children’s Social Care and Learning Disabilities have been addressed as part of the 2015/16 Service & Resource Planning process. Performance

Academic librarians would also do better at making themselves visible as ‘academics’, and therefore more capable of teaching students and faculty about information literacy, if

grant  numbers  71771122  and  71862035;  The  Humanities  and  Social  Sciences  Foundation  of 

Top left of (b) shows a zoom window of the junction to highlight the geocorrection. Eagle data is a spiral flight line collected near the south west of the M25 motorway in

· To study the adoption of Cell phone and cyber banking in India · To examine the usage of banking serves through Cyber banking · To analyze the banking services adoption

Julia, as symbol of Mother Ireland and a past that is no longer relevant, is juxtaposed with a turning towards a new way of engaging with the world that is dramatized through