• No results found

THE PRISMAFLEX SYSTEM

N/A
N/A
Protected

Academic year: 2021

Share "THE PRISMAFLEX SYSTEM"

Copied!
5
0
0

Loading.... (view fulltext now)

Full text

(1)

PRISMAFLEX

SYSTEM

(2)

PATIENTS

BENEFIT

No two AKI patients are the same. The diversity of critically ill patients requires individualized care. Unlike Intermittent Hemodialysis (IHD) or Slow Low Efficiency Dialysis (SLED), the Prismaflex System delivers slow, continuous 24-hour treatment for: // Fluid removal

// Acid-base balance // Electrolyte balance

The Prismaflex System is the only device that delivers multiple modes of therapy without additional equipment.

CVVHDF // continuous veno-venous hemodiafiltration CVVHD // continuous veno-venous hemodialysis CVVH // continuous veno-venous hemofiltration SCUF // slow continuous ultrafiltration

TPE // therapeutic plasma exchange

VERSATILITY

that Helps Meet Diverse

Patient Needs

Continuous therapy designed for small to large molecular clearance

Display of both prescribed and actual therapy dosage Safety features including fluid measurement and removal are designed to help minimize risk of injury to patient, and reduce alarms and downtime

Efficiency through real-time presentation of data and storage of treatment history to help ensure patient safety, clear understanding of patient status and treatment parameters

Physiologic therapy promotes fluid removal for critically ill patients.

SUPPORT

a System Designed for

Acute Kidney Injury

The

Prismaflex

Control Unit is

intended for:

Continuous Renal Replacement

Therapy (CRRT) for patients

weighing 20 kilograms or more

with acute renal failure and/or fluid

overload.

Therapeutic Plasma Exchange

(TPE) therapy for patients weighing

20 kilograms or more with diseases

where fluid removal of plasma

components is indicated.

The

Prismaflex

System helps help support critically ill patients with Acute

Kidney Injury (AKI). When considering patient therapy, safety features and ease

of use, the reasons to implement CRRT with the

Prismaflex

System add up.

The

Prismaflex

System

can help you meet the demands of multiple

therapies with a versatile platform that can be customized to

specific patient needs.

The ability to run TPE on the

Prismaflex

System

offers clinicians

many features to meet the needs of your patients.

(3)

DESIGNED WITH

// Uses a highly accurate, scale-based fluid management system (+/- 300 ml/24 hrs). We recommend a

comparison of our accuracy specification to other systems for your consideration1

// Offers fluid removal accuracy through algorithms and self-calibrating fluid scales

// Monitors accumulated fluid balance/imbalance and adjusts accordingly to help reduce risk of patient injury

ACCURATE

Fluid Management

// Provides automated and integrated anticoagulation options through the 5th fluid pump (pre-blood pump) and syringe pump

// Eliminates the need for manual dose programming of ancillary pumps outside the CRRT system

CRRT requires carefully balanced anticoagulation, which is administered during therapy in accordance with a physician’s order.

INTEGRATED

Anticoagulation

Baxter has led the industry in advancing CRRT. The

Prismaflex

System is designed for the critically ill patient. Its fluid algorithms

help balance patient chemistry with fluid removal for optimal

therapy delivery. Clinicians can monitor how much therapy the

patient is receiving within 7 mL of fluid accuracy, at any given time.

SAFETY IN MIND

PROVEN

Hemofilter Sets

// Offers proven performance; AN 69 hemofilters were used exclusively in the RENAL Study2

// Demonstrates middle/large molecule clearance

// Offers both low to high flow filter sets to help meet your patients’ needs // Eliminates requirement for periodic filter flushings

By providing a wide range of molecular clearances, Baxter hemofilter sets are designed to maximize therapy delivery for critically-ill patients, and help reduce complexity for clinicians.

// Allows for prescription flexibility and acid-base balance3,4 using a wide

range of bicarbonate buffered solutions with various ionic formulations // May help reduce preparation time, waste and potential for medication

errors associated with manually mixed products5,6

// All fluids are packaged in two-compartment bags to ensure solution stability

With market-leading sterile dialysate and FDA-approved replacement fluids, Baxter is your source for sterile solutions designed for therapy flexibility.

MULTIPLE

(4)

A nurse’s time is precious

when observing and caring

for patients. The

Prismaflex

System provides automatic

adjustments and visual

feedback of the system’s

condition to help manage

patient therapy.

// Deareation chamber automatically removes air during therapy to help prevent lost time searching for air, and removing it manually via a syringe // Automatic air removal during

therapy delivery prevents downtime

Automatic air removal eliminates circuit downtime that may lead to premature clotting due to static blood while manual air removal is conducted.

PATENTED

Air Removal Chamber

// Provides automatic, real-time tracking of all relevant pressures including filter pressure and transmembrane pressure (TMP)

// Self-checks every two hours to eliminate manual monitoring and calibration of pressure sensors // Detects system leaks

automatically

Automated system checks may help reduce manual nurse intervention.

AUTOMATED

Pressure Monitoring

and Calibration

// Integrates conveniently with most hospital EMR systems, either directly or through a third party

// Eliminates manual recording and transfer of CRRT treatment data // Enables CRRT treatment

data download

EMR Connectivity promotes improved clinician workflow by helping to reduce manual documentation.

INTEGRATED

EMR Connectivity*

COMPLETE

From Start to Finish

SIMPLY

MANAGED

// All sets automatically load and self-prime

// Tubing on hemofilter sets are preconnected and color coded for easy visual setup

// System disposables and effluent never need to touch the floor // Back-up battery enables 10+ minutes of uninterrupted therapy

delivery upon temporary power disconnect7

// Intuitive on-screen troubleshooting visuals are accessible during setup and therapy delivery

// Does not require confirmation that therapy bags are draining equally // Scale-based systems allow for real-time automated measuring of

(5)

REFERENCES:

1 Prismflex Operator’s Manual 2 RENAL: Randomized Evaluation of

Normal versus Augmented Level of Renal Replacement. Bellomo et al, Intensity of Continuous Renal Replacement Therapy in Critically Ill Patients. N Engl J Med 2009; 361; 1627 – 38.

3 Macias, W.L., Choice of replacement fluid/dialysate anion in continuous renal replacement therapy. American Journal of Kidney Diseases, 1996; Vol. 28, No 5, Suppl. 3 (October), pp. S15-S20 4 Druml, W. Metabolic aspects of

continuous renal replacement therapies. Kidney International, 1989, Vol. 56 5 Culley, C.M. et al., Implementing a

standardized safety procedure for continuous renal replacement therapy solutions. American Journal of Health System Pharmacy, 2006; 63:756-63 6 Barletta, J.F., Resource Utilization and

Total Cost of Commercially Available versus Manually Compounded Solutions Used for Dialysate in Continuous Renal Replacement Therapy. Hospital Pharmacy, 2008; 43:29-34

7 Internal Data on file

* Please consult with your Baxter Sales Representative for further information regarding validated EMR systems.

To learn more about the

Prismaflex

System,

please call

800-525-2623.

Use the complete CRRT system

that delivers what patients and

healthcare providers need.

Integrated CVVHDF

//

The only device that delivers all modes of CRRT

without ancillary pumps—and TPE

Accurate fluid management

//

Scale-based system with +/- 300 mL/24 hrs

Patented air removal

//

Removes air continuously and automatically

to help prevent lost time

EMR connectivity*

//

Integrates conveniently with most hospital EMR systems,

either directly or through a third party

www.baxter.com

Baxter, AN 69 and Prismaflex are trademarks of Baxter International Inc., or its subsidiaries. USMP/MG120/14-0011(1) 1000 08/15

References

Related documents

The purpose of this in vivo study was to compare the accuracy of Propex II and iPex II electronic apex locator (EAL) in determining the WL under clinical conditions, to that

Secondary prevention is defined as early treatment of disease so as to prevent its continuation, and tertiary prevention is described as treatment of the chronically ill, to

Obwohl die jüngsten Studien gezeigt haben, dass es eine direkte Verbindung zwischen Entzündung und TVT gibt 126,127 , ist die genaue Rolle der Immunzellen in der

In order to observe the effect of baicalin on MG infection from the ultrastructural level of cells, the lung and tracheal tissues were selected from each group for transmission

In the absence of such a notice, the applicant represents and warrants to the Credit Union that the Credit Union may continue to rely upon this Personal Statement as a complete,

Maintain insurance coverage throughout licensure and keep on file in the board's office evidence of such coverage. Failure to maintain liability and worker's compensation

significantly higher during high flow conditions because of storm water runoff from the watershed. H2: Stream DOC, N and P concentrations will be significantly lower during the hot

Fundamentally, there are unintended consequences of the current financial aid system because from the perspective of competing schools, it does not make sense to take their