I N D U S T R I A L C A B L E G L A N D S

N/A
N/A
Protected

Academic year: 2021

Share "I N D U S T R I A L C A B L E G L A N D S"

Copied!
20
0
0

Loading.... (view fulltext now)

Full text

(1)
(2)

Introduction

A1/A2 Industrial Cable Gland

BW Industrial Cable Gland

BWL Heavy Duty Industrial Cable Gland

CW Industrial Cable Gland

CZ Industrial Cable Gland

E1W Industrial Cable Gland

E1Z Industrial Cable Gland

CXT Industrial Cable Gland

Gland Accessories

Gland Kits

Brass Gland - Selection Chart

Wiping Glands

Fittings For Wiping Glands

Conduit Fittings

Ingress Protection Index

Entry Thread Options

2 - 3

4

5

6

7

8

9

10

11

12

12

13

14

15

16

17

18

IN

D

U

S

T

R

IA

L

C

A

B

L

E

G

L

A

N

D

S

IN

D

EX

(3)

Axis

offers a wide range of Industrial Cable Glands for indoor and outdoor use.

The Cable glands meet the performance requirements of

BS 6121 : Part I / BS EN 50262

and are manufactured in

brass to

BS 2874

standard.

Entry threads are available in Metric, PG, NPT & Imperial sizes.

Axis

, by translating its Technological expertise, Manufacturing Process and Product Application to innovative

solutions ensures complete customer satisfaction

(4)

Axis

glands are being used worldwide and are supported by a wide network of distributors and wholesalers. Owing to

our good track record of reliable supplies our customer base has spanned major sectors like Industrial, Power and Oil

fields, just to name a few.

Axis

has been dedicated to provide its customers, solutions, adding value to their business and also develop products

as per their specific requirements, from short to large production run.

This catalogue has been compiled and logically structured enabling the original equipment manufacturers, electrical

contractors, distributors, wholesalers and retailers to find product information easily and efficiently.

(5)

Brass indoor and outdoor cable gland highly suitable for all types of unarmoured cables, plastic or rubber sheathed cables. This gland provides a seal on outer sheath.

Recommended to use PVC shroud for additional ingress protection.

A1/A2

BS 6121 : Part I : 1989

IP66

Brass

Plain Brass or Nickel Plated

Thermoplastic Elastomer

Unarmoured

Displacement Type

Outer Sheath

Type

Design Specification

Ingress protection

Gland Material

Finish

Seal Material

Cable Type

Sealing Technique

Sealing Area

TECHNICAL DATA

IN

D

U

S

T

R

IA

L

C

A

B

L

E

G

L

A

N

D

S

A1/A2 Industrial Cable Gland

E

B

D A C AAG0016B AAG0020SSB AAG0020SB AAG0020LB AAG0025SB AAG0025LB AAG0032LB AAG0040LB AAG0050SB AAG0050LB AAG0063SB AAG0063LB AAG0075SB AAG0075LB AAG0090LB AAG0100LB E- CODE 21.30 23.60 23.60 26.85 30.50 35.50 41.30 47.00 55.00 59.95 64.75 69.85 78.75 84.60 102.60 119.10 Across Flat 'E’ Max

(6)

TECHNICAL DATA

BW KNURLING TYPE

BS 6121 : Part I : 1989

IP3X

Brass

Plain Brass or Nickel Plated

Steel Wire Armour

Two Part Armour Lock

Type

Design Specification

Ingress Protection

Gland Material

Finish

Cable Type

Armour Clamping

IN

D

U

S

T

R

IA

L

C

A

B

L

E

G

L

A

N

D

S

Brass indoor glands most suitable for single wire armoured, plastic or rubber sheathed cable.

Earth tags to be use for earth continuity.

Recommended to use with shroud for additional ingress protection.

BW Industrial Cable Gland

B E D A C 21.00 21.00 23.40 33.50 40.10 50.30 56.65 62.70 76.20 92.70 Across Flat 'E’ Max

(7)

TECHNICAL DATA

BWL

BS 6121 : Part I : 1989

IP3X

Brass

Plain Brass or Nickel Plated

Steel Wire Armour

Three Part Armour Lock

Type

Design Specification

Ingress Protection

Gland Material

Finish

Cable Type

Armour Clamping

Brass indoor glands most suitable for single wire armoured, plastic or rubber sheathed cable. Lockring provided for additional grip to the armour.

Earth tags to be use for earth continuity.

BWL glands are also supplied with integral earth facilities.

Recommended to use with shroud for additional ingress protection.

BWL Heavy Duty Industrial Cable Gland

B E D A C BWL0016B BWL0020SB BWL0020LB BWL0025SB BWL0025LB BWL0032LB BWL0040SB BWL0040LB BWL0050SB BWL0050LB BWL0063SB BWL0063LB BWL0075SB BWL0075LB BWL0090B E- CODE 21.30 23.60 25.40 31.10 34.00 40.40 44.90 48.70 57.40 61.00 70.10 74.80 84.30 90.10 105.30 Across Flat 'E’ Max

IN

D

U

S

T

R

IA

L

C

A

B

L

E

G

L

A

N

D

S

(8)

TECHNICAL DATA

Type

Design Specification

Ingress Protection

Finish

Gland Material

Seal Material

Cable Type

Armour Clamping

Sealing Technique

Sealing Area

CW

BS 6121 : Part I : 1989

IP 66

Thermoplastic Elastomer

Plain Brass or Nickel Plated

Steel Wire Armour

Three Part (With Lock Nut)

Compression Type

Outer Sheath

Brass

Brass indoor and outdoor gland most popularly used with single wire armoured, plastic or rubber sheathed cable. Terminates and secured cable armouring and outer seal grips sheath of cable thus ensuring mechanical strength and earth continuity.

Earth tags to be use for earth continuity.

CW brass glands are also supplied with integral earth facilities. Recommended to use PVC shroud for additional ingress protection.

CW Industrial Cable Gland

B

D

E C A CWG0016B CWG0020SB CWG0020LB CWG0025SB CWG0025LB CWG0032LB CWG0040SB CWG0040LB CWG0050SB CWG0050LB CWG0063SB CWG0063LB CWG0075SB CWG0075LB CWG0090LB E- CODE 24.20 24.00 27.17 32.75 34.30 42.90 49.30 50.80 61.70 63.75 73.90 78.50 87.40 96.00 105.30 Across Flat 'E’ Max

IN

D

U

S

T

R

IA

L

C

A

B

L

E

G

L

A

N

D

S

(9)

TECHNICAL DATA

CZ

BS 6121 : Part 1 : 1989

IP 66

Brass

Plain Brass or Nickel Plated

Thermoplastic Elastomer

Steel Tape Armour

Three Part (With Lock Nut)

Compression Type

Outer Sheath

Type

Design Specification

Ingress protection

Gland Material

Finish

Seal Material

Cable Type

Armour Clamping

Sealing Technique

Sealing Area

Brass gland suitable for steel tape armoured, plastic or rubber sheathed cables. Terminates and secure cable armouring and outer seal grips sheath of cable thus ensuring mechanical strength and earth continuity.

CZ brass glands are also supplied with integral earth facilities. Earth tags to be use for earth continuity.

Recommended to use PVC shroud for additional ingress protection.

CZ Industrial Cable Gland

B E C A D CZG0016B CZG0020SB CZG0020LB CZG0025SB CZG0025LB CZG0032B CZG0040SB CZG0040LB CZG0050SB CZG0050LB CZG0063SB CZG0063LB CZG0075SB CZG0075LB CZG0090B E- CODE 24.20 24.00 27.17 32.75 34.30 42.90 49.30 50.80 61.70 63.75 73.90 78.50 87.40 96.00 105.30 Across Flat 'E’ Max

IN

D

U

S

T

R

IA

L

C

A

B

L

E

G

L

A

N

D

S

(10)

TECHNICAL DATA

Type

Design Specification

Ingress Protection

Finish

Gland Material

Seal Material

Cable Type

Armour Clamping

Sealing Technique

Sealing Area (s)

E1W

BS 6121 : Part I : 1989

IP 66

Thermoplastic Elastomer

Plain Brass or Nickel Plated

Steel Wire Armour

Three Part Armour Lock

Compression & Displacement Type

Inner & Outer Sheath

Brass

Brass indoor and outdoor cable glands highly suitable for single wire armoured, plastic or rubber sheathed cables. Provides grip to the cable with outer and inner seals. Used popularly in most climatic conditions weatherproof and waterproof. Earth tags to be use for earth continuity.

E1W brass glands are also supplied with integral earth facilities. Recommended to use PVC shroud for additional ingress protection.

E1W Industrial Cable Gland

E1W0016B E1W0020SB E1W0020LB E1W0025SB E1W0025LB E1W0032LB E1W0040SB E1W0040LB E1W0050SB E1W0050LB E1W0063SB E1W0063LB E1W0075SB E1W0075LB E1W0090B E- CODE 24.10 24.10 27.17 32.75 35.85 42.90 49.30 50.80 61.70 63.75 73.90 78.50 87.40 96.00 105.30 Across Flat 'E’ Max B D E C A

IN

D

U

S

T

R

IA

L

C

A

B

L

E

G

L

A

N

D

S

(11)

TECHNICAL DATA

E1Z

BS 6121 : Part 1 : 1989

IP 66

Brass

Plain Brass or Nickel Plated

Thermoplastic Elastomer

Steel Tape Armour

Three Part Armour Lock

Compression & Displacement Type

Inner & Outer Sheath

Type

Design Specification

Ingress protection

Gland Material

Finish

Seal Material

Cable Type

Armour Clamping

Sealing Technique

Sealing Area (s)

Brass indoor and outdoor cable glands suitable for steel tape armoured, plastic or rubber sheathed cable. Provides grip to the cable with outer and inner seals. Used in most climatic conditions weatherproof and waterproof. Earth tags to be use for earth continuity.

E1Z brass glands are also supplied with integral earth facilities. Recommended to use PVC shroud for additional ingress protection.

E1Z Industrial Cable Gland

E1Z0016B E1Z0020SB E1Z0020LB E1Z0025SB E1Z0025LB E1Z0032B E1Z0040SB E1Z0040LB E1Z0050SB E1Z0050LB E1Z0063SB E1Z0063LB E1Z0075SB E1Z0075LB E1Z0090B E- CODE 24.10 24.10 27.17 32.75 35.85 42.90 49.30 50.80 61.70 63.75 73.90 78.50 87.40 96.00 105.30 Across Flat 'E’ Max B D E C A

IN

D

U

S

T

R

IA

L

C

A

B

L

E

G

L

A

N

D

S

(12)

TECHNICAL DATA

CXT

BS 6121 : Part 1 : 1989

IP 66

Brass

Plain Brass or Nickel Plated

Thermoplastic Elastomer

Braided Armoured Type

Displacement Type

Outer Sheath

Type

Design Specification

Ingress protection

Gland Material

Finish

Seal Material

Cable Type

Sealing Technique

Sealing Area

Brass indoor and outdoor cable gland suitable for braided type, plastic or rubber sheathed cables.

This gland provides seal on outer sheath.

Recommended to use with PVC shroud for additional ingress protection. armoured

CXT Industrial Cable Gland

CXT0016B CXT0020SSB CXT0020SB CXT0020B CXT0025LB CXT0032LB CXT0040LB CXT0050SB CXT0050LB E- CODE 21.3 23.6 23.6 26.85 30.5 41.3 47 55 59.95 Across Flat 'E’ Max E B C A D

IN

D

U

S

T

R

IA

L

C

A

B

L

E

G

L

A

N

D

S

(13)

LOCKNUTS

Locknuts are recommended to use with cable glands to secure it to a gland plate or to equipment. It is highly recommended to use brass locknut with gland for all the atmospheric conditions. Sizes available from 16mm to 90mm

(Imperial and PG sizes also available)

EARTH TAGS

Earth tags are installed between the cable gland and equipment to provide earth continuity as specified in BS 6121 Part 5, 1993

Sizes available from 16mm to 90mm

PVC SHROUD

The shroud are recommended to use with all cable glands to provide additional ingress protection and to minimize the risk of dirt or any foreign substance gathering around gland body.

PVC Shrouds are denoted by gland reference number and are compatible with each glands size.

GLAND ACCESSORIES

GLAND KIT

Axis provides ready to use gland kit which consists of all the basic components required to terminate the cable to the equipments.

See kit details below.

Kit Details

Size

20 - 25 32 - 90

Component / Kit

Glands, Locknuts, Earthtags, PVC Shrouds and Screws - 2 Ea. Gland, Locknut, Earthtag, PVC Shroud and Screw - 1 Ea.

Note: For A1/A2 Glands Earth Tag not required.

IN

D

U

S

T

R

IA

L

C

A

B

L

E

G

L

A

N

D

S

(14)

600 / 1000v stranded copper conductors pvc insulated with steel wire armour and PVC sheathed overall. Cable to BS 6346 : 1997

Cable Size Conductor Numbers of Cores

Nom. Area (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 300 400 500 630 800 1000 -16 16 25 35 50 70 70 95 120 150 185 185 -1 -25 25 25 32 32 32 40 40 40 50S 50 50 63S 63 2 16 20S 20S 20 25 25 25 32 32 32 40 40 50S 50 50 63S 63 63 -3 16 20S 20 20 25 25 32 32 32 40 40 50S 50 50 63S 63 63 75S -31/2 -32 32 32 40 50S 50 50 63S 63 75S 75 75 -4 20S 20S 20 20 25 25 32 40 40 40 50S 50 63S 63 75S 75 75 75 -5 20S 20S 20 -7 20S 20 25 -10 20 25 25 -12 20 25 25 -19 25 25 32 -27 25 32 40 -37 32 32 -48 32 40 -Neutral

600 / 1000v stranded copper conductors xlpe/swa/pvc cable and PVC sheathed overall. Cable to BS 5467 : 1989

Cable Size Conductor

Numbers of Cores

Nom. Area (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 300 400 500 630 800 1000 -16 16 25 35 50 70 70 95 120 150 185 185 -1 -25 25 25 32 32 32 40 40 40 50S 50 50 63S 63 2 20S 20S 20S 20 20 25 25 32 25 32 32 40 40 50S 50 63S 63S 63S -3 20S 20S 20S 20 25 25 32 32 32 32 40 40 50S 50 63S 63 63 75S -31/2 -32 32 32 40 50S 50 50 63S 63 75S 75S 75 -4 20S 20S 20 20 25 25 32 32 32 40 50S 50 50 63S 63 75S 75 75 -5 20S 20S 20 -7 20S 20 25 -10 20 25 25 -12 25 25 25 -19 25 32 32 -27 32 32 40 -37 32 40 40 -48 32 40 50S -Neutral

IN

D

U

S

T

R

IA

L

C

A

B

L

E

G

L

A

N

D

S

(15)

WIPING GLAND

Material : Brass

Finish : Natural

Dimention in mm

A B C D E F G H J R

Dia over metal sheath of cable (mm) Gland Size X Y Z E - Code AWGX AWGY AWGZ 12 to 51 25 to 78 25 to 94 137 155 195 90 95 140 60 89 108 19 32 32 90 114 190 90 123 100 66 95 -66 86 -12 14 14 12 14 -6 HOLES ØJ B E F G E F H R 4 HOLES ØJ

Gland Size X & Y

A B 10 12.5 25 Ø C 3 ØD Gland Size Z C 25 A 4 11 12.5 Ø ØD

IN

D

U

S

T

R

IA

L

C

A

B

L

E

G

L

A

N

D

S

(16)

FITTINGS FOR WIPING GLANDS

Insulating Plates

Insulating Bush

Material : Thermoplastic Elastomer or Cork

Material : Neoprene

ØA ØC Ø B D E

Armour Clamp

Material : M.S Strip

Finish : Electro Zinc Plated

A 25 ØC ØA 6 HOLES ØG ØH B D C E ØH Ø G Gland Size Insulating Plate Insulating Bush X Y Z PX PY PZ A B B Dimention in mm A B C D E Insulating Bush A B 15 18 11.2 14 22 28 28 28 10 10 Dimention in mm A B C Gland Size X Y Z 140 175 190 108 145 160 73 103 123 E - Code AACX AACY AACZ Dimension in mm A B C D E G H Insulating Plate PX PY PZ -190 90 114 -66 86 -90 123 -66 95 -14 16 16 60 90 108 E - Code APX50002 APY50001 APZ50003

IN

D

U

S

T

R

IA

L

C

A

B

L

E

G

L

A

N

D

S

(17)

CONDUIT FITTINGS

Male - Female Bushes

Material:Brass as per BS 2874

Finish:Brass as natural.

Sizes:Metric : 20mm to 50mm

(Short and Long patterns)

Adaptors

Material:Brass as per BS 2874

Finish:Brass as natural or Nickel plated.

Sizes:Metric : 12mm to 50mm

Imperial: 1/2” to 2”

Also available with swivel type fittings.

Flexible Conduit PVC Coated

As per BS 731

Material:G. I. Strip

Coating:Temperature resistant PVC

IP Rating:IP 65 or IP 50 with standard fittings

Working Temperatures : Min : -20 C Max : +70 C

°

°

Colour:Black

Sizes: Metric : 12mm to 50mm

Imperial : 1/2” to 2”

Flexible Conduit Nylon Coated

As per BS 731

Material:G. I. Strip

Coating:Nylon

IP Rating:IP 65 or IP 50 with standard fittings

Working Temperatures : Min : -30 C Max : +110 C

°

°

Colour:Black

Sizes: Metric : 12mm to 50mm

Imperial : 1/2” to 2”

IN

D

U

S

T

R

IA

L

C

A

B

L

E

G

L

A

N

D

S

(18)

INGRESS PROTECTION INDEX

50mm

12.5mm

2.5mm

1mm

Protected against solid objects larger than 50 mm diameter

Protected against solid objects larger than 12.5 mm diameter

Protected against solid objects larger than 2.5 mm diameter

Protected against solid objects larger than 1 mm diameter

Protected against dust

Completely protected against dust (Dust-tight) 1 2 3 4 5 6

Protection Against Solids. 1st Digit :

Protected against drops of water falling vertically

Protected against drops of water falling at up to 15 from the vertical

°

Protected against rain at up to 60 from the vertical

°

Protected against splashing of water from all directions

Protected against jets of water from all directions

Protected against projections of water from all directions

Protected against the effect of immersion

Protected against the effects of submersion 1 2 3 4 5 7 6 8

2nd Digit : Protection Against Solids.

15cm 1m

IP

X 0 No Test No Protection

IP

X 0 No Test No Protection

IN

D

U

S

T

R

IA

L

C

A

B

L

E

G

L

A

N

D

S

(19)

ENTRY THREAD OPTIONS

Cable Gland Size ISO Metric 16 20/16 20S 20 25 32 40 50S 50 63S 63 75S 75 90 M16 M20 M20 M20 M25 M32 M40 M50 M50 M63 M63 M75 M75 M90 1/2" 1/2" 1/2" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2" 2-1/2" 2-1/2" 3" 3" 11 11 13.5 16 21 29 36 36 42 48 -1/2" 1/2" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2" 2-1/2" 2-1/2" 3" 3" 5/8" 3/4" 3/4" 3/4" 1" 1-1/4" 1-1/2" 2" 2" 2-1/2" 2-1/2" 3" 3" 3-1/2" NPT P.G. PF / BSP Imperial

(20)

References

Related documents

In general, corrective osteotomies of phalangeal or metacarpal bones represent a rare indication in hand surgery. These procedures require a high degree of indi- vidual planning, due

Keywords: ESWT, Radial extracorporeal shockwave therapy, Recurrence rate, Symptomatic shoulder calcifying tendinopathy,

Before being attached to start data collection, the unit was pro- grammed to adjust for the patient ’ s individual height, walking speed (slow, normal, fast) and range of

Using an uncumbersome, wearable computer to read small, inexpensive, and unpowered RFID tags inconspicuously placed around Ann Arbor, a blind person using this

The medio-lateral knee motion assessed by visual inspection during the single-limb mini squat was valid in 2-D, showing a medially placed tibia and thigh, and knee valgus in

Physicians almost universally endorse cancer screening [19]. However, high rates of physician recommendations for screening are not supported by either chart docu- mentation [20]

reported a subluxa- tion/reluxation rate of 13% (six of 45 operated knees) in an average follow-up examination period of 13.5 years, where 14 patients and 15 Roux-Elmslie-Trillat

CSST, an inter-disciplinary research program, draws faculty associates from the departments of Anthropology, History, and Sociology, and several other departments and programs in