• No results found

Effects of extremity positioning on radiographic evaluation of femoral tunnel location with digitally reconstructed femoral lateral radiographs after anterior cruciate ligament reconstruction

N/A
N/A
Protected

Academic year: 2020

Share "Effects of extremity positioning on radiographic evaluation of femoral tunnel location with digitally reconstructed femoral lateral radiographs after anterior cruciate ligament reconstruction"

Copied!
8
0
0

Loading.... (view fulltext now)

Full text

Figure

Fig. 1 a and b: Digitally reconstructed radiographs showing distal femoral tunnel (arrowheads) and tunnel aperture (arrow) in 1a and Bernardand Hertel grid in 1b
Table 1 Inter-observer variability and standard error of measurement of quadrant methods for evaluation of tunnel aperture orificeafter anatomic single-bundle anterior cruciate ligament reconstruction
Table 2 Tunnel positions relative to Blumensaat’s line
Fig. 4 Femoral ACL tunnel aperture location expressed as percentage along the line perpendicular to the Blumensaat(’s line (%DP) in relation todegree of rotation for various rotation types

References

Related documents

We then further studied the novel application of BCDTs to study its role as a general pattern recognition and image classification technique. As a test case, we showed that a BCDT

Our protocol for designing an allosterically controlled ribozyme for one-input logic gate comprises of three generating steps, (the same steps outlined in Table 1 with only a

some investors, or more precisely 'speculators', who use their money with the intention of making a profit in a short time. Since there are Muslims who

The increased in initial dye concentration decreased the photodegradation and the increased catalyst loading increased the degradation percentage and the reused-ZnO

The society’s activity covers a wide spectrum from log construction (including, under the tutelage of Tarmo Tammekivi, timber frame construction) to the organisation of various

The remove of direct blue (DB71) anionic dye on flint clay in aqueous solution was investigated by using a batch system for various dye concentrations.. The contact time, pH,

Results: Step length, stride length reduced and angle of toe out increased significantly in reading during walking and texting during walking as compared to only

Serum Creatinine and Creatinine clearance for Predicting Plasma Methotrexate Concentrations after High dose Methotrexate Chemotherapy for the Treatment for Childhood