Oct. 2013 1st Edition
ESLON
®AC DRAIN PIPE
ESLON
®AC DRAIN Fittings
ESLON
®Transparent AC DRAIN Fittings
ESLON
®AC DRAIN Flexible Unit
Most suita
ble piping
material
for
air conditio
ning draina
ge
Rigid PVC Pipe and Fittings with anti water condensation layer for air conditioning drainage
ESLON AC Drain Pipe and Fittings Catalog
SEKISUI CHEMICAL CO.,LTD. All rights reserved.
Urban Infrastructure &
Environmental Products Company
Oct. 2013 First Edition
http://www.sekisuichemical.com
2013 .10. 0TH TX
Colors of the actual products may vary from the colors shown in this printed material.
Information in this document is subject to change without notice.
1
1 2Installation is identical to a conventional DV connection. There is no outer insulation material. Therefore, inspection work on joint and slope setting is much easy. In addition, visual inspection and securing the joint works are feasible by using Transparent Fittings.
Eslon AC Drain Pipe and Fittings prevent water condensation and do not require any insulation work.
It is a perfect fit for air conditioning drainage in office, hotel and hospital, etc.
Can be applied for air conditioning drainage regardless whether the system is packaged air conditioner or fan coil unit.
Packaged Air Conditioner
Pipe for refrigerant gas
Pipe for refrigerant gas Drainage Hose, etc. Pipe for refrigerant liquid Pipe for refrigerant liquid
Fi-Block/Fire Protection PVC Pipe
Fi-Block/Fire Protection PVC Pipe
Eslon AC Drain Pipe and Fittings
Eslon AC Drain Flexible Unit
Packaged Air Conditioner
Eslon AC Drain Pipe and Fittings System is economical because of easy installation and elimination of insulation work.
Example of AC Drain Pipe Plumbing [In case plumbing length is 13meter]
5,000 1,000 3,000 1,500 1,500 500 500 Adapter Adapter ø25 Elbow ø25 ø25 ø25 ø25 ø30 ø30 ø25 Elbow ø25 Elbow ø25 Socket ø30×ø25 Socket ø30×ø25 90˚ Tee AC Drain VP Pipe + Insulation Material
(Fitting : Ivory) Insulation MaterialSGP (Steel) + The above is based
on publicly announced cost information in Japan.
Plumbing Labor
AC Drain Pipe plumbing is set as 100. 44% 56% 0% 100% 109% 13% 12% 34% 50% 192% 34% 86% 12% 60% Installation Labor Insulation Material Plumbing Material
Installation Cost Comparison (assume 2 sets of fan coil unit)
Multiple operations were required.
In case of Packaging Air Conditioning
Refrigerant
Arrangement Cold and Hot WaterDrainage Work
Insulation Work Drainage Work Insulation Work
AC Drains
AC Drains
is effective to reduce installation time. is effective to reduce installation time.Multiple works can be eliminated. Multiple works can be eliminated.
with
AC Drain
Conventional Method
In case of Fan Coil Unit Refrigerant, Drainage, Insulation Work,
Cold and Hot Water, Drainage and Insulation Work,
Fan Coil Unit
Pipe for Hot and Cold Water Pipe for Hot and Cold Water
Fi-Block/Fire Protection PVC Pipe
Fi-Block/Fire Protection PVC Pipe
Eslon AC Drain Pipe and Fittings
Drain Hose, etc.
Fan Coil Unit
Eslon AC Drainage Pipe and Fittings have a function of thermal insulation. Therefore you do not need any insulation work.
D
E
C
Most suitable piping material for air conditioning drainage is
AC Drain Pipe and Fittings!
AC Drain Pipe
AC Drain Pipe
Air Conditioning Unit
AC Drain Flexible Unit for pump up area.
AC Drain Pipe
Mark in this brochure
CautionIn case left hand mark is stated, it may cause serious injury or burn wound unless properly treated.
Caution
Items with left hand mark is precaution statement to secure the performance of material
Separately heat up or use AC Drain Flexible Unit for pump up section.
May not needed, but please check the condition and determine properly. Category Condition
Application for Air Conditioning Drainage Water Pressure Under no pressure (Note) Water Temperature Normal Temperature (5-35˚C)
Nominal Diameter 20-50
Note: Except pump up whose length is less than 1meter
Applicable Range
Caution Increase insulation property to prevent moisture condensation.Feasible to connect pipe and fittings by adhesive.
ABS Foamed Layer
Provide a good connection with fitting.
PVC Surface Layer
Secure flow property for drainage.
Rigid PVC Layer
Have superior function in thermal insulation and prevention of water condensation.
Outer Diameter Identical to VP pipe which is 1 size larger.
PVC Foamed Layer
Same size with standard socket
Cross Linked PE Foam Main Body of Fitting(ABS)
Provide smooth transition between pipe and fittings for smooth flow of drainage.
Pipe
Fitting (Injection Molded Foam Products)
Water condensation is prevented by foamed layer.
Both Pipe and Fittings have a foamed insulation layer. This prevents whole
plumbing from water condensation without having outer insulation material.
o not need insulation work
asy to Install and Improve the Quality
ost Saving
solve all problems!
Problems
Eslon AC Drain Pipe & Fittings
on conventional air conditioning drainage.
Insulation work
It is a time consuming
for insulation work.
Cannot check joint
and slope angle.
Threading is painful work.
Secure the installation
Threading work
1
1 2Installation is identical to a conventional DV connection. There is no outer insulation material. Therefore, inspection work on joint and slope setting is much easy. In addition, visual inspection and securing the joint works are feasible by using Transparent Fittings.
Eslon AC Drain Pipe and Fittings prevent water condensation and do not require any insulation work.
It is a perfect fit for air conditioning drainage in office, hotel and hospital, etc.
Can be applied for air conditioning drainage regardless whether the system is packaged air conditioner or fan coil unit.
Packaged Air Conditioner
Pipe for refrigerant gas
Pipe for refrigerant gas Drainage Hose, etc. Pipe for refrigerant liquid Pipe for refrigerant liquid
Fi-Block/Fire Protection PVC Pipe
Fi-Block/Fire Protection PVC Pipe
Eslon AC Drain Pipe and Fittings
Eslon AC Drain Flexible Unit
Packaged Air Conditioner
Eslon AC Drain Pipe and Fittings System is economical because of easy installation and elimination of insulation work.
Example of AC Drain Pipe Plumbing [In case plumbing length is 13meter]
5,000 1,000 3,000 1,500 1,500 500 500 Adapter Adapter ø25 Elbow ø25 ø25 ø25 ø25 ø30 ø30 ø25 Elbow ø25 Elbow ø25 Socket ø30×ø25 Socket ø30×ø25 90˚ Tee AC Drain VP Pipe + Insulation Material
(Fitting : Ivory) Insulation MaterialSGP (Steel) + The above is based
on publicly announced cost information in Japan.
Plumbing Labor
AC Drain Pipe plumbing is set as 100. 44% 56% 0% 100% 109% 13% 12% 34% 50% 192% 34% 86% 12% 60% Installation Labor Insulation Material Plumbing Material
Installation Cost Comparison (assume 2 sets of fan coil unit)
Multiple operations were required.
In case of Packaging Air Conditioning
Refrigerant
Arrangement Cold and Hot WaterDrainage Work
Insulation Work Drainage Work Insulation Work
AC Drains
AC Drains
is effective to reduce installation time. is effective to reduce installation time.Multiple works can be eliminated. Multiple works can be eliminated.
with
AC Drain
Conventional Method
In case of Fan Coil Unit Refrigerant, Drainage, Insulation Work,
Cold and Hot Water, Drainage and Insulation Work,
Fan Coil Unit
Pipe for Hot and Cold Water Pipe for Hot and Cold Water
Fi-Block/Fire Protection PVC Pipe
Fi-Block/Fire Protection PVC Pipe
Eslon AC Drain Pipe and Fittings
Drain Hose, etc.
Fan Coil Unit
Eslon AC Drainage Pipe and Fittings have a function of thermal insulation. Therefore you do not need any insulation work.
D
E
C
Most suitable piping material for air conditioning drainage is
AC Drain Pipe and Fittings!
AC Drain Pipe
AC Drain Pipe
Air Conditioning Unit
AC Drain Flexible Unit for pump up area.
AC Drain Pipe
Mark in this brochure
CautionIn case left hand mark is stated, it may cause serious injury or burn wound unless properly treated.
Caution
Items with left hand mark is precaution statement to secure the performance of material
Separately heat up or use AC Drain Flexible Unit for pump up section.
May not needed, but please check the condition and determine properly. Category Condition
Application for Air Conditioning Drainage Water Pressure Under no pressure (Note) Water Temperature Normal Temperature (5-35˚C)
Nominal Diameter 20-50
Note: Except pump up whose length is less than 1meter
Applicable Range
Caution Increase insulation property to prevent moisture condensation.Feasible to connect pipe and fittings by adhesive.
ABS Foamed Layer
Provide a good connection with fitting.
PVC Surface Layer
Secure flow property for drainage.
Rigid PVC Layer
Have superior function in thermal insulation and prevention of water condensation.
Outer Diameter Identical to VP pipe which is 1 size larger.
PVC Foamed Layer
Same size with standard socket
Cross Linked PE Foam Main Body of Fitting(ABS)
Provide smooth transition between pipe and fittings for smooth flow of drainage.
Pipe
Fitting (Injection Molded Foam Products)
Water condensation is prevented by foamed layer.
Both Pipe and Fittings have a foamed insulation layer. This prevents whole
plumbing from water condensation without having outer insulation material.
o not need insulation work
asy to Install and Improve the Quality
ost Saving
solve all problems!
Problems
Eslon AC Drain Pipe & Fittings
on conventional air conditioning drainage.
Insulation work
It is a time consuming
for insulation work.
Cannot check joint
and slope angle.
Threading is painful work.
Secure the installation
Threading work
Transparent
AC Drain Fittings
New
Line Up!!
New
Line Up!!
AC Drain
Flexible Unit
ABS Foamed Layer
Easy to conduct visual check to avoid insufficientadhesive or insufficient insertion.
Transparent Material
(
ABS
)
Main Body
Structure
Structure
Feature
Example of plumbing
Characteristics
Easy installation by flexible structure
Thermal insulated flexible pipe is much easy for installation.
Proper
connecting condition
Not inserted
sufficiently
No adhesive
was applied
Adhesive No. 73S Blue Adhesive No. 75S Blue NFeasible to check connecting condition visually.
Easy installation for pump up section
Cross linked PE foam
Same size to
DV socket
Heat insulated flexible pipe
Protective Tape
Socket for Pipe Connection
Socket for AC Drain
Equipment side elbow
Pipe Socket
*Please use 65A for vinyl SU pipe to fix fitting, and 32A to fix flexible pipe.
Strap support structure
Feasible to conduct proper plumbing by fixing
both fitting and hose.
Thermal Insulation is not required.
No insulation work is required for entire pipeline by use
of AC Drain Flexible Unit and AC Drain Pipe & Fittings.
Heat
insulation
Prevent
water
condensation
Please referto page 7 for specification.
Easy to check connecting condition
Refer Page 5, 6, 7for product line and specification.
Sealing Material
Thermal Insulated Flexible Hose Socket
AC Drain Pipe
Fix Fitting
Fix Flexible Pipe
Transparent AC Drain Fittings
Transparent AC Drain Fittings
AC Drain Pipe
AC Drain Pipe
For pump up section
Superior in thermal insulation
High thermal insulation property allows not
to use insulation material even in full of water section.
*In case of identical use condition to AC Drain
Feasible to connect to AC Drain
It has an identical sealing material. Connection
to AC Drain Pipe is feasible.
No insulation work is needed Extended View VP25 Flexible Hose Hose Band
AC Drain
25
Feasible to check visually about the
adhesive condition between pipe and
fittings with the use of blue adhesive.
Use Eslon Adhesive No. 73S Blue or No. 75S Blue Nfor the use of transparent AC drain fitting.
Transparent
AC Drain Fittings
New
Line Up!!
New
Line Up!!
AC Drain
Flexible Unit
ABS Foamed Layer
Easy to conduct visual check to avoid insufficientadhesive or insufficient insertion.
Transparent Material
(
ABS
)
Main Body
Structure
Structure
Feature
Example of plumbing
Characteristics
Easy installation by flexible structure
Thermal insulated flexible pipe is much easy for installation.
Proper
connecting condition
Not inserted
sufficiently
No adhesive
was applied
Adhesive No. 73S Blue Adhesive No. 75S Blue NFeasible to check connecting condition visually.
Easy installation for pump up section
Cross linked PE foam
Same size to
DV socket
Heat insulated flexible pipe
Protective Tape
Socket for Pipe Connection
Socket for AC Drain
Equipment side elbow
Pipe Socket
*Please use 65A for vinyl SU pipe to fix fitting, and 32A to fix flexible pipe.
Strap support structure
Feasible to conduct proper plumbing by fixing
both fitting and hose.
Thermal Insulation is not required.
No insulation work is required for entire pipeline by use
of AC Drain Flexible Unit and AC Drain Pipe & Fittings.
Heat
insulation
Prevent
water
condensation
Please referto page 7 for specification.
Easy to check connecting condition
Refer Page 5, 6, 7for product line and specification.
Sealing Material
Thermal Insulated Flexible Hose Socket
AC Drain Pipe
Fix Fitting
Fix Flexible Pipe
Transparent AC Drain Fittings
Transparent AC Drain Fittings
AC Drain Pipe
AC Drain Pipe
For pump up section
Superior in thermal insulation
High thermal insulation property allows not
to use insulation material even in full of water section.
*In case of identical use condition to AC Drain
Feasible to connect to AC Drain
It has an identical sealing material. Connection
to AC Drain Pipe is feasible.
No insulation work is needed Extended View VP25 Flexible Hose Hose Band
AC Drain
25
Feasible to check visually about the
adhesive condition between pipe and
fittings with the use of blue adhesive.
Use Eslon Adhesive No. 73S Blue or No. 75S Blue Nfor the use of transparent AC drain fitting.
5
6
6
Lineup of Eslon AC Drain Pipe and Fittings
Z L Z L 45° 20 25 30 40 50 14 16 18 22 26 33 35 41 48 62 80 160 100 60 30 AC4L20N AC4L25N AC4L30N AC4L40N AC4L50N AC4L20S AC4L25S AC4L30S AC4L40S AC4L50S Effective Length Z Nominal
Diameter LengthL per packageQuantity Part #Ivory TransparentPart # Unit:mm
45°Elbow
Z2 Z1 L2 L1 L 3 Z 3 91°1 0’ 23 26 23 31 23 26 38 23 26 31 46 23 26 31 38 23 26 23 31 23 26 38 23 26 31 47 24 27 32 39 23 26 26 31 31 31 38 38 37 37 46 46 46 46 46 40 100 40 60 24 60 30 20 40 40 20 20 20 20 20 20 25 25×20 30 30×20 30×25 40 40×20 40×25 40×30 50 50×20 50×25 50×30 50×40 ACT20N ACT25N ACT251N ACT30N ACT302N ACT301N ACT40N ACT403N ACT402N ACT401N ACT50N ACT504N ACT503N ACT502N ACT501N ACT20S ACT25S ACT251S ACT30S ACT302S ACT301S ACT40S ACT403S ACT402S ACT401S ACT50S ACT504S ACT503S ACT502S ACT501S Z1 Z2 Z3 L1 42 45 42 54 46 49 64 49 52 57 82 59 62 67 74 L2 42 45 42 54 46 49 64 49 52 57 83 60 63 68 75 L3 42 45 45 54 50 50 64 57 56 60 82 65 64 69 72 NominalDiameter Effective Length Length per packageQuantity Part #Ivory TransparentPart # Unit:mm
90°Tee
L 2 L 1 L3 Z 2 Z 1 Z3 45° 16 24 24 12 62 76 96 84 66 82 102 92 30 25 14 15 30 40 50 50×40 ACY30N ACY40N ACY50N ACY501N ACY30S ACY40S ACY50S ACY501S Z1 Z2 Z3 L1 39 50 60 48 L2 85 102 132 120 L3 89 108 138 118 NominalDiameter Effective Length
Length Quantity
per package Part #Ivory TransparentPart # Unit:mm L
T
t
øD
Part # DiameterNominal Quantity
per package 32.0 38.0 48.0 60.0 76.0 4,000 20 25 30 40 50 ACD20P ACD25P ACD30P ACD40P ACD50P 6.5 6.5 8.5 9.0 9.5 1.7 2.0 2.0 2.2 2.5 19.0 25.0 31.0 42.0 57.0 0.41 0.50 0.72 1.00 1.41 16 12 9 6 4 Unit:mm Outer Diameter øD Length L Thickness T Approximate Inner Diameter (Reference) Thickness of rigid PVC layer t Reference Weight (kg/m) 91°10’ L Z L Z Effective
Length Z LengthL per packageQuantity Part #Ivory TransparentPart # 20 25 30 40 50 23 26 31 37 46 42 45 54 63 82 80 160 100 50 20 ACL20N ACL25N ACL30N ACL40N ACL50N ACL20S ACL25S ACL30S ACL40S ACL50S Nominal Diameter Unit:mm Nominal
Diameter Inner Diameter Length ofSocket Pipe Thicknesst1(Minimum) Pipe Thickness t2(Minimum) ød1 ød2 ød 20 25 30 40 50 32.25 38.25 48.30 60.35 76.40 31.85 37.85 47.80 59.75 75.70 19.0 25.0 31.0 42.0 57.0 23 23 27 30 40 8.5 8.5 8.7 9.1 9.4 2.7 2.7 2.7 3.1 3.1 Unit:mm t 2 t 2 t 1 ø d 2 ø d ød 1 t 1 ø d 2 ø d ød1 t 2 t 2 t 1 ø d 2 ø d ød 1 t 1 ø d 2 ø d ød 1
<ABS Injection Molded Foam Products>
Injection Molded Foam Products Injection Molded Product
Pipe
Fittings Socket Dimension (Common)
90°Elbow
45°Y
<Rigid PVC Injection Molded Product>
L Z 20 25 25×20 30 30×25 40 40×30 50 50×40 11 11 13 11 12 11 13 11 13 49 49 51 57 54 63 62 83 75 120 240 80 160 180 80 100 40 60 ACS20N ACS25N ACS251N ACS30N ACS301N ACS40N ACS401N ACS50N ACS501N ACS20S ACS25S ACS251S ACS30S ACS301S ACS40S ACS401S ACS50S ACS501S Nominal
Diameter EffectiveLength Z LengthL per packageQuantity Part #Ivory TransparentPart # Unit:mm
Socket
Z øD L 34 39 17 21 24 TS20 TS25 DV30 DV40 DV50 26.0 32.0 38.0 48.0 60.0Remarks: 1. Refer to Page 8 how to apply
2. Connect same nominal diameter of AC Drain for female socket. Use TS fitting for spigot side in nominal diameter 20, 25 and DV fitting in nominal diameter of 30, 40 and 50
(TS fitting is not applicable for those diameters). 20 25 30 40 50 41 46 24 29 32 60 65 47.5 55 64.5 100 80 80 50 30 ACDA20 ACDA25 ACDA30 ACDA40 ACDA50 ACA20S ACA25S ACA30S ACA40S ACA50S øD Inlet Spigot side Fitting Nominal
Diameter EffectiveLength Z LengthL per packageQuantity Part #Ivory TransparentPart # Unit:mm
Nominal Diameter 20, 25
Nominal Diameter 30, 40, 50
Adapter (Transition Fitting to PVC Pipe)
Z øD L 72 76 MD Fitting40 MD Fitting50 48 60
Remarks: 1. Connect identical nominal diameter AC Drain Pipe for socket side. Connect MD Fitting for spigot side
(Do not apply TS Fitting or DV Fitting for spigot side) 2. Do not cut and use spigot
3. Conduct thermal insulation for spigot side Length L 40 50 80 84 105 119 Quantity per Package Ivory
Part # TransparentPart # 12 25 ACMD40 ACMD50 ACMD40S ACMD50S øD Spigot Spigot side Fitting Effective Length Z Nominal Diameter Unit:mm
5
6
6
Lineup of Eslon AC Drain Pipe and Fittings
Z L Z L 45° 20 25 30 40 50 14 16 18 22 26 33 35 41 48 62 80 160 100 60 30 AC4L20N AC4L25N AC4L30N AC4L40N AC4L50N AC4L20S AC4L25S AC4L30S AC4L40S AC4L50S Effective Length Z Nominal
Diameter LengthL per packageQuantity Part #Ivory TransparentPart # Unit:mm
45°Elbow
Z2 Z1 L2 L1 L 3 Z 3 91°1 0’ 23 26 23 31 23 26 38 23 26 31 46 23 26 31 38 23 26 23 31 23 26 38 23 26 31 47 24 27 32 39 23 26 26 31 31 31 38 38 37 37 46 46 46 46 46 40 100 40 60 24 60 30 20 40 40 20 20 20 20 20 20 25 25×20 30 30×20 30×25 40 40×20 40×25 40×30 50 50×20 50×25 50×30 50×40 ACT20N ACT25N ACT251N ACT30N ACT302N ACT301N ACT40N ACT403N ACT402N ACT401N ACT50N ACT504N ACT503N ACT502N ACT501N ACT20S ACT25S ACT251S ACT30S ACT302S ACT301S ACT40S ACT403S ACT402S ACT401S ACT50S ACT504S ACT503S ACT502S ACT501S Z1 Z2 Z3 L1 42 45 42 54 46 49 64 49 52 57 82 59 62 67 74 L2 42 45 42 54 46 49 64 49 52 57 83 60 63 68 75 L3 42 45 45 54 50 50 64 57 56 60 82 65 64 69 72 NominalDiameter Effective Length Length per packageQuantity Part #Ivory TransparentPart # Unit:mm
90°Tee
L 2 L 1 L3 Z 2 Z 1 Z3 45° 16 24 24 12 62 76 96 84 66 82 102 92 30 25 14 15 30 40 50 50×40 ACY30N ACY40N ACY50N ACY501N ACY30S ACY40S ACY50S ACY501S Z1 Z2 Z3 L1 39 50 60 48 L2 85 102 132 120 L3 89 108 138 118 NominalDiameter Effective Length
Length Quantity
per package Part #Ivory TransparentPart # Unit:mm L
T
t
øD
Part # DiameterNominal Quantity
per package 32.0 38.0 48.0 60.0 76.0 4,000 20 25 30 40 50 ACD20P ACD25P ACD30P ACD40P ACD50P 6.5 6.5 8.5 9.0 9.5 1.7 2.0 2.0 2.2 2.5 19.0 25.0 31.0 42.0 57.0 0.41 0.50 0.72 1.00 1.41 16 12 9 6 4 Unit:mm Outer Diameter øD Length L Thickness T Approximate Inner Diameter (Reference) Thickness of rigid PVC layer t Reference Weight (kg/m) 91°10’ L Z L Z Effective
Length Z LengthL per packageQuantity Part #Ivory TransparentPart # 20 25 30 40 50 23 26 31 37 46 42 45 54 63 82 80 160 100 50 20 ACL20N ACL25N ACL30N ACL40N ACL50N ACL20S ACL25S ACL30S ACL40S ACL50S Nominal Diameter Unit:mm Nominal
Diameter Inner Diameter Length ofSocket Pipe Thicknesst1(Minimum) Pipe Thickness t2(Minimum) ød1 ød2 ød 20 25 30 40 50 32.25 38.25 48.30 60.35 76.40 31.85 37.85 47.80 59.75 75.70 19.0 25.0 31.0 42.0 57.0 23 23 27 30 40 8.5 8.5 8.7 9.1 9.4 2.7 2.7 2.7 3.1 3.1 Unit:mm t 2 t 2 t 1 ø d 2 ø d ød 1 t 1 ø d 2 ø d ød1 t 2 t 2 t 1 ø d 2 ø d ød 1 t 1 ø d 2 ø d ød 1
<ABS Injection Molded Foam Products>
Injection Molded Foam Products Injection Molded Product
Pipe
Fittings Socket Dimension (Common)
90°Elbow
45°Y
<Rigid PVC Injection Molded Product>
L Z 20 25 25×20 30 30×25 40 40×30 50 50×40 11 11 13 11 12 11 13 11 13 49 49 51 57 54 63 62 83 75 120 240 80 160 180 80 100 40 60 ACS20N ACS25N ACS251N ACS30N ACS301N ACS40N ACS401N ACS50N ACS501N ACS20S ACS25S ACS251S ACS30S ACS301S ACS40S ACS401S ACS50S ACS501S Nominal
Diameter Length ZEffective LengthL per packageQuantity Part #Ivory TransparentPart # Unit:mm
Socket
Z øD L 34 39 17 21 24 TS20 TS25 DV30 DV40 DV50 26.0 32.0 38.0 48.0 60.0Remarks: 1. Refer to Page 8 how to apply
2. Connect same nominal diameter of AC Drain for female socket. Use TS fitting for spigot side in nominal diameter 20, 25 and DV fitting in nominal diameter of 30, 40 and 50
(TS fitting is not applicable for those diameters). 20 25 30 40 50 41 46 24 29 32 60 65 47.5 55 64.5 100 80 80 50 30 ACDA20 ACDA25 ACDA30 ACDA40 ACDA50 ACA20S ACA25S ACA30S ACA40S ACA50S øD Inlet Spigot side Fitting Nominal
Diameter Length ZEffective LengthL per packageQuantity Part #Ivory TransparentPart # Unit:mm
Nominal Diameter 20, 25
Nominal Diameter 30, 40, 50
Adapter (Transition Fitting to PVC Pipe)
Z øD L 72 76 MD Fitting40 MD Fitting50 48 60
Remarks: 1. Connect identical nominal diameter AC Drain Pipe for socket side. Connect MD Fitting for spigot side
(Do not apply TS Fitting or DV Fitting for spigot side) 2. Do not cut and use spigot
3. Conduct thermal insulation for spigot side Length L 40 50 80 84 105 119 Quantity per Package Ivory
Part # TransparentPart # 12 25 ACMD40 ACMD50 ACMD40S ACMD50S øD Spigot Spigot side Fitting Effective Length Z Nominal Diameter Unit:mm
7
8
8
Installation procedure of Eslon AC Drain Pipe and Fittings
Connection to different pipe
Mark cutting line for whole
circumference and cut at right
angle against axis by saw.
Apply Eslon adhesive (No. 73S Blue, No. 75S
Blue N, No. 73S, No. 75S) evenly to inner
surface of fitting, at the edge face of pipe
and outer surface of pipe.
Conduct light-chamfering for both
inner and outer surface on the
edge of pipe.
Do not use PVC cutter, etc. that may cause crack or chap.
5
Apply adhesive
2
Chamfer
1
Cut
Remove sand, soil or dust, etc.
and water content attached to the
inner surface of socket or inserting
section of pipe by cloth.
Mark inserting length to the pipe
stated below.
<Ivory>
Insert pipe quickly till marked
section is covered.
<Transparent>
Insert pipe quickly till the end.
6
Insert
7
Hold (wipe off adhesive / ventilation)
Hold pipe and fittings more than 30
seconds.
Wipe off adhesive that comes out of
the section by cloth.
Please provide sufficient ventilation
after insertion.
In case of rough surface, it would remove adhesive on the socket and cause loose.
Please apply adhesive not only to inner surface of fitting, outer surface of pipe but also to the edge face of pipe.
Please use adhesive No. 73S Blue or No. 75S Blue N for transparent AC Drain fitting.
Reference) Inserting Length Unit: mm
Nominal Diameter Inserting Length 20 19 25 19 30 23 40 26 50 36
The outer diameter of AC Drain Pipe against nominal diameter is identical to 1 size larger outer diameter of PVC pipe. Thus, supporting claps, etc. for PVC pipe can be used. Arrange the pitch of support to AC Drain Pipe identical to standard VP pipe whose diameter is identical.
Apply adhesive
for edge face of pipe
3
Wipe off
4
Mark inserting length
* Clean with slight amount of industrial alcohol in case oil is attached to the connecting section.
Marking for inserting section Apply adhesive for outer surface of pipe
Please make sure to use AC Drain Transition Fitting to connect to the difference pipe. (1) Connecting AC Drain Pipe to PVC
pipe in nominal diameter of 20 and 25 (use TS Fitting)
Connect with the combination of adapter fitting and TS fitting.
Caution
Thermal insulation is required for VP Pipe and TS Fitting.
*Can be used to connect to drain hose as well.
(2) Connecting AC Drain Pipe to PVC pipe in nominal diameter of 30, 40 and 50 (use DV Fitting) Connect with the combination of adapter fitting and DV fitting.
Caution
Thermal insulation is required for VP Pipe and DV Fitting.
Caution
The dimension of inserting section is for DV fitting. TS fitting cannot be used.
(3) In case connecting MD Fitting and AC Drain Pipe
Use MD Fitting Adapter. Caution
Do not cut spigot.
Caution
Do not connect to TS or DV Fitting for spigot side.
Caution
Need thermal insulation treatment on inserting area of MD Fitting Adapter and MD Fitting
VP Pipe ø25 AC Drain Pipe VP Pipe ø50
ø25 AC Drain Pipe ø50 TS Fitting ø25
TS Socket in same nominal diameter
DV Fitting ø50 Adapter
ø25 Adapterø50
DV Socket in same nominal diameter ConnectingMD Fitting AC DrainPipe ø40 Adapter ø40 MD Fitting
ø40 VP Pipe ø25 AC Drain Pipe VP Pipe ø50
ø25 AC Drain Pipe ø50 TS Fitting ø25
TS Socket in same nominal diameter
DV Fitting ø50 Adapter
ø25 Adapterø50
DV Socket in same nominal diameter ConnectingMD Fitting AC DrainPipe ø40 Adapter ø40 MD Fitting
ø40 VP Pipe ø25 AC Drain Pipe VP Pipe ø50
ø25 AC Drain Pipe ø50 TS Fitting ø25
TS Socket in same nominal diameter
DV Fitting ø50 Adapter
ø25 Adapterø50
DV Socket in same nominal diameter ConnectingMD Fitting Pipe ø40AC Drain Adapter ø40 MD Fitting
ø40
Installation Process
Lineup of Eslon AC Drain Pipe and Fittings
L 2 L 3 D2 O Ring D3 D1 L 1 D1 Clamp Torque(N•m) 20 25 30 40 50 JNCO25N JNCO30N JNCO40N JNCO50N JNCO65N 2 2 4 5 5 41 45 55 68 84 D2 27 32 41 51 69 D3 32 38 48 60 76 L1 19 19 23 26 36 L2 L3 42.5 41.2 44.5 47.5 57.5 17.5 19.5 24 29 36 200 200 240 132 68 Remarks: 1. Do not use where contacting water continuously.
It may cause water condensation.
2. 1 Size larger nominal diameter is stated to AC Drain. AC Drain
Nominal Diameter
Quantity per package Part #Ivory
Unit:mm
Related Products
L1 L 2 d 1 d 2 d 1 d 2 L1 1,000 Protective Tape EquipmentSide Elbow Plumbing Side Socket
Material 25 Equipment Side Pipe Side d1 32.25 38.25 d2 31.85 37.85 25 18 Z1 Z2 35 36 L1 60 31 L2 73 -- 5 ACFU25
Remarks: Equipment side meets to VP25 and Pipe side meets AC Drain 25 Nominal Diameter Quantity per package Ivory Transparent Unit:mm
AC Drain Flexible Unit
Screw type cleaning hole
Eslon Adhesive
Remarks: Use either No. 73S Blue or No. 75S Blue N for transparent AC Drain Fitting.
Use it as standard adhesive for AC Drain
Volume: 500g (w/ Brush) 1 kg (w/ Brush) No. 73S Blue <Colored Adhesive> Volume: 500g (w/ Brush) 1 kg (w/ Brush) No. 75S Blue N
<Colored low viscosity type> Volume:
500g (w/ Brush) 1 kg (w/ Brush) No.73S Volume: 500g (w/ Brush) 1 kg (w/ Brush) No.75S
<Rigid PVC Injection Molded Product>
<Equipment Side Elbow: Foamed ABS Injection Molded Product, Plumbing Side Socket: Rigid PVC Injection Molded Product>
<In case the size is 40> <In case the size is 50>
7
8
8
Installation procedure of Eslon AC Drain Pipe and Fittings
Connection to different pipe
Mark cutting line for whole
circumference and cut at right
angle against axis by saw.
Apply Eslon adhesive (No. 73S Blue, No. 75S
Blue N, No. 73S, No. 75S) evenly to inner
surface of fitting, at the edge face of pipe
and outer surface of pipe.
Conduct light-chamfering for both
inner and outer surface on the
edge of pipe.
Do not use PVC cutter, etc. that may cause crack or chap.
5
Apply adhesive
2
Chamfer
1
Cut
Remove sand, soil or dust, etc.
and water content attached to the
inner surface of socket or inserting
section of pipe by cloth.
Mark inserting length to the pipe
stated below.
<Ivory>
Insert pipe quickly till marked
section is covered.
<Transparent>
Insert pipe quickly till the end.
6
Insert
7
Hold (wipe off adhesive / ventilation)
Hold pipe and fittings more than 30
seconds.
Wipe off adhesive that comes out of
the section by cloth.
Please provide sufficient ventilation
after insertion.
In case of rough surface, it would remove adhesive on the socket and cause loose.
Please apply adhesive not only to inner surface of fitting, outer surface of pipe but also to the edge face of pipe.
Please use adhesive No. 73S Blue or No. 75S Blue N for transparent AC Drain fitting.
Reference) Inserting Length Unit: mm
Nominal Diameter Inserting Length 20 19 25 19 30 23 40 26 50 36
The outer diameter of AC Drain Pipe against nominal diameter is identical to 1 size larger outer diameter of PVC pipe. Thus, supporting claps, etc. for PVC pipe can be used. Arrange the pitch of support to AC Drain Pipe identical to standard VP pipe whose diameter is identical.
Apply adhesive
for edge face of pipe
3
Wipe off
4
Mark inserting length
* Clean with slight amount of industrial alcohol in case oil is attached to the connecting section.
Marking for inserting section Apply adhesive for outer surface of pipe
Please make sure to use AC Drain Transition Fitting to connect to the difference pipe. (1) Connecting AC Drain Pipe to PVC
pipe in nominal diameter of 20 and 25 (use TS Fitting)
Connect with the combination of adapter fitting and TS fitting.
Caution
Thermal insulation is required for VP Pipe and TS Fitting.
*Can be used to connect to drain hose as well.
(2) Connecting AC Drain Pipe to PVC pipe in nominal diameter of 30, 40 and 50 (use DV Fitting) Connect with the combination of adapter fitting and DV fitting.
Caution
Thermal insulation is required for VP Pipe and DV Fitting.
Caution
The dimension of inserting section is for DV fitting. TS fitting cannot be used.
(3) In case connecting MD Fitting and AC Drain Pipe
Use MD Fitting Adapter. Caution
Do not cut spigot.
Caution
Do not connect to TS or DV Fitting for spigot side.
Caution
Need thermal insulation treatment on inserting area of MD Fitting Adapter and MD Fitting
VP Pipe ø25 AC Drain Pipe VP Pipe ø50
ø25 AC Drain Pipe ø50 TS Fitting ø25
TS Socket in same nominal diameter
DV Fitting ø50 Adapter
ø25 Adapterø50
DV Socket in same nominal diameter ConnectingMD Fitting AC DrainPipe ø40 Adapter ø40 MD Fitting
ø40 VP Pipe ø25 AC Drain Pipe VP Pipe ø50
ø25 AC Drain Pipe ø50 TS Fitting ø25
TS Socket in same nominal diameter
DV Fitting ø50 Adapter
ø25 Adapterø50
DV Socket in same nominal diameter ConnectingMD Fitting AC DrainPipe ø40 Adapter ø40 MD Fitting
ø40 VP Pipe ø25 AC Drain Pipe VP Pipe ø50
ø25 AC Drain Pipe ø50 TS Fitting ø25
TS Socket in same nominal diameter
DV Fitting ø50 Adapter
ø25 Adapterø50
DV Socket in same nominal diameter ConnectingMD Fitting AC DrainPipe ø40 Adapter ø40 MD Fitting
ø40
Installation Process
Lineup of Eslon AC Drain Pipe and Fittings
L 2 L 3 D2 O Ring D3 D1 L 1 D1 Clamp Torque(N•m) 20 25 30 40 50 JNCO25N JNCO30N JNCO40N JNCO50N JNCO65N 2 2 4 5 5 41 45 55 68 84 D2 27 32 41 51 69 D3 32 38 48 60 76 L1 19 19 23 26 36 L2 L3 42.5 41.2 44.5 47.5 57.5 17.5 19.5 24 29 36 200 200 240 132 68 Remarks: 1. Do not use where contacting water continuously.
It may cause water condensation.
2. 1 Size larger nominal diameter is stated to AC Drain. AC Drain
Nominal Diameter
Quantity per package Part #Ivory
Unit:mm
Related Products
L1 L 2 d 1 d 2 d 1 d 2 L1 1,000 Protective Tape EquipmentSide Elbow Plumbing Side Socket
Material 25 Equipment Side Pipe Side d1 32.25 38.25 d2 31.85 37.85 25 18 Z1 Z2 35 36 L1 60 31 L2 73 -- 5 ACFU25
Remarks: Equipment side meets to VP25 and Pipe side meets AC Drain 25 Nominal Diameter Quantity per package Ivory Transparent Unit:mm
AC Drain Flexible Unit
Screw type cleaning hole
Eslon Adhesive
Remarks: Use either No. 73S Blue or No. 75S Blue N for transparent AC Drain Fitting.
Use it as standard adhesive for AC Drain
Volume: 500g (w/ Brush) 1 kg (w/ Brush) No. 73S Blue <Colored Adhesive> Volume: 500g (w/ Brush) 1 kg (w/ Brush) No. 75S Blue N
<Colored low viscosity type> Volume:
500g (w/ Brush) 1 kg (w/ Brush) No.73S Volume: 500g (w/ Brush) 1 kg (w/ Brush) No.75S
<Rigid PVC Injection Molded Product>
<Equipment Side Elbow: Foamed ABS Injection Molded Product, Plumbing Side Socket: Rigid PVC Injection Molded Product>
<In case the size is 40> <In case the size is 50>
9
10
10
Installation Procedure of AC Drain Flexible Unit
3
Connection of Elbow on device side
4
Fix support of elbow on device side
5
Connect socket to pipe side
6
Fix support for heat insulating flexible pipe
2
Chamfer
1
Air conditioner and horizontal drain plumbing
Flexible Hose Elbow Plumbing side socket
Horizontal Drain Plumbing. (AC Drain Pipe, Fitting) Secure
the hanging position of support
Air Conditioner
Apply
adhesive to
edge face of pipe
Indicating mark for insertionApply adhesive to outer surface of pipe Socket on pipe side AC Drain Pipe
Flexible Hose
Socket on pipe side Air Conditioner
Heat insulating flexible pipe Protective Tape
Fix and support heat insulating flexible pipe + wrap by protective tape included in the package
Flexible Hose Support and Fix
Dent
Supporting clasp: 65A for Vinyl SU pipe Elbow on device side
Air Conditioner
Flexible Hose Elbow Flexible Hose
Elbow Air Conditioner
Arrange the distance of plumbing below 700mm between
flexible hose attached to air conditioner and horizontal drain
plumbing. Also, please arrange the maximum height of AC
Drain Flexible Unit less than the maximum height specified
by air conditioner manufacturer.
In case of bringing up AC Drain Flexible Unit from air conditioner, the height should be arranged less than the maximum height air conditioner manufacturer specifies. Also, the length of horizontal plumbing should not have excess tension (less than 700mm).
Fix support firmly to dent of elbow on device side
(Supporting clasp: 65A for Vinyl SU pipe)
Connect supporting clasp to the dent of elbow on device side, and fix flexible hose not to deflect it.
Apply Eslon adhesive evenly to socket on pipe side and Drain
horizontal plumbing (AC Drain Pipe 25A), and insert till the
end.
Do not drag or bend from elbow too much. Also, do not twist heat insulating flexible pipe.
*Apply adhesive to edge face of AC Drain Pipe in case of connecting AC Drain Pipe to socket on pipe side.
Wrap protective tape at the top of bring up section, and
firmly fix the support.
(Applicable supporting claps : 32A for SGP Pipe)
Wrap by protective tape included in the package before fixing heat insulating flexible pipe by claps.
Please do not cause back draft from brought up section. Please do not drag or bend heat insulating flexible pipe too much.
Please do not bend heat insulating flexible pipe less than minimum bending radius of 111mm.
Check connecting position of elbow on air conditioner side to
decide the position of support.
Check the position of support
Elbow on device side requires support. Please make sure to arrange support to it.
Apply Eslon adhesive (No. 73S Blue, No. 75S Blue N, No.
73S, No. 75S) evenly to elbow on device side and VP 25
connected to the edge of flexible hose.
Then, insert till the end.
Please pay attention not to apply adhesive to thermal insulating flexible pipe. Please check VP25A short pipe is feasible to connect in case of using flexible hose included as attachment to an air conditioner. Also, please note insulation treatment is needed for that short pipe section.
*Please follow standard procedure for DV fitting in case connecting by adhesive.
Twist of heat insulating flexible pipe Flexible Hose Socket on pipe side AC Drain Pipe Air Conditioner Extended View Below 700mm Length of horizontal plumbing Flexible Hose Elbow Socket AC Drain Pipe, Fitting Air Conditioner Height VP25 Flexible Hose Hose Band
Installation Process
Performance of Eslon AC Drain Pipe, Fitting and AC Drain Flexible Unit
Capability to prevent moisture condensation
Condition:Nominal diameter 25, Flow amount 3 liter/hour, Pipe Slope 1/50
Caution
Performance of AC Drain Pipe and Fittings in horizontal plumbing, and AC Drain Flexible Unit on brought up section. Please conduct thermal insulation separately in case AC
Drain Pipe and Fittings are applied for full water area including brought up section.
It may not needed depends on the condition. Please check the condition to determine.
10 15 20 25 30 Relative Humidity (%) Outer Temperature ( ˚C ) Area water condensation occurs Area water condensation occurs 60 65 70 75 80 85 90 95
100 Water Temperature 15˚C Water Temperature 10˚C
10 15 20 25 30 Relative Humidity (%) Outer Temperature ( ˚C ) 60 65 70 75 80 85 90 95 100
Area not to cause water condensation
Area not to cause water condensation 10 15 20 25 30 Relative Humidity (%) Outer Temperature ( ˚C ) Area water condensation occurs Area water condensation occurs 60 65 70 75 80 85 90 95
100 Water Temperature 15˚C Water Temperature 10˚C
10 15 20 25 30 Relative Humidity (%) Outer Temperature ( ˚C ) 60 65 70 75 80 85 90 95 100
Area not to cause water condensation
Area not to cause water condensation
<Design>
[Note]
VP Pipe ... Standard PVC Pipe which is durable for water hammer pressure of 1.0MPa DV Fitting ... PVC fitting for non pressure application including drainpipe
TS Fitting ... PVC fitting for pressure application
MD Fitting .... Cast finishing fitting for non pressure application SU Pipe ... Thin walled PVC Pipe
9
10
10
Installation Procedure of AC Drain Flexible Unit
3
Connection of Elbow on device side
4
Fix support of elbow on device side
5
Connect socket to pipe side
6
Fix support for heat insulating flexible pipe
2
Chamfer
1
Air conditioner and horizontal drain plumbing
Flexible Hose Elbow Plumbing side socket
Horizontal Drain Plumbing. (AC Drain Pipe, Fitting) Secure
the hanging position of support
Air Conditioner
Apply
adhesive to
edge face of pipe
Indicating mark for insertionApply adhesive to outer surface of pipe Socket on pipe side AC Drain Pipe
Flexible Hose
Socket on pipe side Air Conditioner
Heat insulating flexible pipe Protective Tape
Fix and support heat insulating flexible pipe + wrap by protective tape included in the package
Flexible Hose Support and Fix
Dent
Supporting clasp: 65A for Vinyl SU pipe Elbow on device side
Air Conditioner
Flexible Hose Elbow Flexible Hose
Elbow Air Conditioner
Arrange the distance of plumbing below 700mm between
flexible hose attached to air conditioner and horizontal drain
plumbing. Also, please arrange the maximum height of AC
Drain Flexible Unit less than the maximum height specified
by air conditioner manufacturer.
In case of bringing up AC Drain Flexible Unit from air conditioner, the height should be arranged less than the maximum height air conditioner manufacturer specifies. Also, the length of horizontal plumbing should not have excess tension (less than 700mm).
Fix support firmly to dent of elbow on device side
(Supporting clasp: 65A for Vinyl SU pipe)
Connect supporting clasp to the dent of elbow on device side, and fix flexible hose not to deflect it.
Apply Eslon adhesive evenly to socket on pipe side and Drain
horizontal plumbing (AC Drain Pipe 25A), and insert till the
end.
Do not drag or bend from elbow too much. Also, do not twist heat insulating flexible pipe.
*Apply adhesive to edge face of AC Drain Pipe in case of connecting AC Drain Pipe to socket on pipe side.
Wrap protective tape at the top of bring up section, and
firmly fix the support.
(Applicable supporting claps : 32A for SGP Pipe)
Wrap by protective tape included in the package before fixing heat insulating flexible pipe by claps.
Please do not cause back draft from brought up section. Please do not drag or bend heat insulating flexible pipe too much.
Please do not bend heat insulating flexible pipe less than minimum bending radius of 111mm.
Check connecting position of elbow on air conditioner side to
decide the position of support.
Check the position of support
Elbow on device side requires support. Please make sure to arrange support to it.
Apply Eslon adhesive (No. 73S Blue, No. 75S Blue N, No.
73S, No. 75S) evenly to elbow on device side and VP 25
connected to the edge of flexible hose.
Then, insert till the end.
Please pay attention not to apply adhesive to thermal insulating flexible pipe. Please check VP25A short pipe is feasible to connect in case of using flexible hose included as attachment to an air conditioner. Also, please note insulation treatment is needed for that short pipe section.
*Please follow standard procedure for DV fitting in case connecting by adhesive.
Twist of heat insulating flexible pipe Flexible Hose Socket on pipe side AC Drain Pipe Air Conditioner Extended View Below 700mm Length of horizontal plumbing Flexible Hose Elbow Socket AC Drain Pipe, Fitting Air Conditioner Height VP25 Flexible Hose Hose Band
Installation Process
Performance of Eslon AC Drain Pipe, Fitting and AC Drain Flexible Unit
Capability to prevent moisture condensation
Condition:Nominal diameter 25, Flow amount 3 liter/hour, Pipe Slope 1/50
Caution
Performance of AC Drain Pipe and Fittings in horizontal plumbing, and AC Drain Flexible Unit on brought up section. Please conduct thermal insulation separately in case AC
Drain Pipe and Fittings are applied for full water area including brought up section.
It may not needed depends on the condition. Please check the condition to determine.
10 15 20 25 30 Relative Humidity (%) Outer Temperature ( ˚C ) Area water condensation occurs Area water condensation occurs 60 65 70 75 80 85 90 95
100 Water Temperature 15˚C Water Temperature 10˚C
10 15 20 25 30 Relative Humidity (%) Outer Temperature ( ˚C ) 60 65 70 75 80 85 90 95 100
Area not to cause water condensation
Area not to cause water condensation 10 15 20 25 30 Relative Humidity (%) Outer Temperature ( ˚C ) Area water condensation occurs Area water condensation occurs 60 65 70 75 80 85 90 95
100 Water Temperature 15˚C Water Temperature 10˚C
10 15 20 25 30 Relative Humidity (%) Outer Temperature ( ˚C ) 60 65 70 75 80 85 90 95 100
Area not to cause water condensation
Area not to cause water condensation
<Design>
[Note]
VP Pipe ... Standard PVC Pipe which is durable for water hammer pressure of 1.0MPa DV Fitting ... PVC fitting for non pressure application including drainpipe
TS Fitting ... PVC fitting for pressure application
MD Fitting .... Cast finishing fitting for non pressure application SU Pipe ... Thin walled PVC Pipe
11
1.Cautions at the stage of planning
This is piping material for drainage of air conditioner. Do not use for pressure application except air conditioner pump up application (below 1mm).
Please arrange thermal insulation for the section where water is full such as at the top of pump up section. Water condensation may occurr in that area. It may not happen depends on the condition, but please check it.
The applicable area is for indoor only. Do not apply for exterior. Treatment with Fi-Block is required for area where fire proof is required.
Steel bar hook (all screw bolt hook) is standard procedure for horizontal plumbing.
Straight plumbing should be less than 30 meter. Arrange elbow every 30 meters (more than 2 elbows: Pitch of elbow more than 0.5 meter).
2.Caution at storage
Arrange the pitch of support to AC Drain Pipe identical to same size of PVC pipe (VP).
Store pipe and fittings inside of a room. Cover by sheet with avoiding to retain heat in case it needs to store outside. Do not use fire in storage room. Fire spark or heat may cause damage to pipe and fittings.
Do not store solvent or paint in storage room. Attack by organic solvent, etc. may cause damage.
3. Caution for transportation
Whole coverage by corrugate board is required, since AC Drain pipe has foamed layer and soft. Need to be handled more carefully than PVC pipe. Never drag or throw.
4.Caution for installation of AC Drain Pipe and Fittings
Use Eslon Adhesive No. 73S Blue, No. 75S Blue N, No. 73S, No. 75S.
Use Eslon Adhesive No. 73S Blue or No. 75S Blue N for transparent AC Drain Fitting.
Please follow instruction to install Eslon AC Drain Pipe and Fittings on page 8.
Please follow the requirements stated below for connection between AC Drain and PVC pipe.The gap at the joint may cause accumulation of water or moisture condensation.
** Make sure to use AC Drain plumbing system with combination of AC Drain Pipe and AC Drain Fittings.
** Make sure to use adapter fitting (refer to page 6) to connect AC Drain Pipe and PVC pipe.
Use 1 size larger fitting of PVC pipe for screw type cleaning hole (joint section needs another thermal insulation).
5. Caution for installation of AC Drain Flexible Unit
Do not drag or bend from the point of fitting.
Do not step on fitting, hose or area where is close to joint. Do not use hose once it has been stepped on even there is no damage visually.
Please minimize the twist for plumbing.
Do not flush chemical liquid (surface activating agent, organic solvent, acid, alkali, etc) or solid content except drain.
Please pay attention not to cause buckling in case supporting material is used.
Do not use hose which had buckling or stepped on even there is no visual damage.
Please replace to new hose in case of re-arranging plumbing such as renewal of air conditioner. It is not feasible for reuse once installed.
Arrange minimum bending radius within 3 times of outer diameter for Drain Pipe.
6. Other cautions
Cut and remove the section in case there is crack, dint or deflection.
In case pipe and fittings are attacked by creosote, asphalt, antiseptic, waterproof agent or ketone, it may swell and break. Please avoid contact of those materials to pipe and fittings. Do not run liquid that containts solvent, ethanol, chlorine, glycoether or ricinus. It may break pipe and result in leakage of liquid. Please pay attention especially when cleaning inside of air conditioner by chemical solution.
Do not step on or hang on pipe.
Avoid fire cause near this product that comes from spark by electric welding, torch lamp or gas barner, etc.
Follow the instruction from gas equipment manufacturer and association concerning the distance to gas equipment such as gas water heater. The condition may differ by the type of equipment. Thus, please consult the distance with gas business operator or manufacturer.
Do not allocate pipes near direct heat such as stove burner. Do not flush chemical content such as solvent, ethanol or chlorine based material. It may break pipe and results in leakage. Please pay attention especially when cleaning the equipment by chemical solution.
In case the volume of adhesive exceeds allowable level, regulation of intoxiation prevention may apply. Detail needs to be checked with local labor standards inspection office.
Please pay attention to fire during installation, since organic solvent such as adhesive is used.
Please conduct sufficient ventilation when adhesive is used. Remove adhesive immediately in case it contacts to skin. Please see doctor if feel sick or unusual.
Some sealing material contains plasticizer (phthalate, DOP, etc.) or organic solvent (xylene, toluene) that may have negative effect on PVC pipe or fitting. Please do not use sealing material that contains those component.
Cable that contains plasticizer may have negative effect on pipe or fitting. Please avoid direct contact of those cables to pipe and fittings.
Please consut us in case there is some skeptical use but not specified in this.
Precautions to use
*Please note we cannot take responsibility for damage or accident in case of use without following the instruction stated here.
Please follow the instruction and conduct safe and secured installation for Eslon AC Drain Pipe and Fittings.
SEKISUI CHEMICAL CO.,LTD. All rights reserved.
Urban Infrastructure &
Environmental Products Company
Oct. 2013 First Edition
2014 .2. 0TH TX
Colors of the actual products may vary from the colors shown in this printed material.
Information in this document is subject to change without notice.
Eslon AC Drain Pipe and Fittings Catalog