(1)

Ph.D. candidate: Giuseppe Abbiati

Advisor: Prof. Oreste S. Bursi

“Dynamic substructuring of complex hybrid systems

based on time-integration, model reduction and

model identification techniques”

Doctoral School in:

“Engineering of Civil and Mechanical Structural Systems”

26

th

cycle

(2)

N

U

M

E

R

IC

A

L

S

ID

E

Delay compensator Transfer system:

Actuators, controllers etc.. Filters

Sensors: Load cells etc..

Physical Substructure (PS)

Numerical Substructure (NS)

E

X

P

E

R

IM

E

N

T

A

L

S

ID

E

n

f

7/10/2014 Page 2

Hybrid system/Hardware-in-the-loop simulator

(3)

- The remaining structure is computed analytically

- Critical non-linear parts are tested in laboratory

Physical piers

-CRITICAL

PARTS-Numerical deck

and piers

Civil eng. application of hybrid simul.: a RC bridge

Hybrid

system

NS

(4)

7/10/2014 Page 4

Mech. eng. application of hybrid simul.: a piping system

Physical piping

branch

-CRITICAL

PARTS-Numerical piping

branch

Hybrid

system

NS

(5)

State of the art limitations in hybrid simulation

PARTITIONED TIME INTEGRATION APPROACH APPLIED

TO A REALISTIC CASE STUDY WITH COMPLEX

NSs

;

MODEL UPDATING OF THE

NS

BASED ON THE

RESPONSE OF A DIFFERENT

PS

SUBJECTED TO

DIFFERENT LOADING;

(6)

State of the art limit.: time integration

Experimental time [s]

Monolithic time

integration

= testing time scale

= integration time step,

= controller time step,

NS

response

PARTITIONED TIME INTEGRATION APPROACH APPLIED TO A

REALISTIC CASE STUDY WITH COMPLEX NSs

Experimental time [s]

Partitioned time

integration

(7)

On-line model updating, Bouc-Wen model, Unscented Kalman filter

State of the art limit.: model updating of NSs

MODEL UPDATING OF THE NS BASED ON THE RESPONSE OF A

DIFFERENT PS SUBJECTED TO DIFFERENT LOADING

NS

(8)

7/10/2014 Page 8

State of the art limit.: distributed parameters PSs

SIMULATION OF A HYBRID SYSTEM CHARACTERIZED BY A

DISTRIBUTED PARAMETER PSs WITH DISTRIBUTED LOADING

PS

(9)

HYBRID SIMULATION OF THE RIO

TORTO BRIDGE

HYBRID SIMULATION OF AN

INDUSTRIAL PIPING SYSTEM

(10)

7/10/2014 Page 10

Rio Torto Bridge: innovative contributions

Application of the partitioned time integration approach,

which allowed for the simulation of nonlinear

NSs

;

(11)

Application of model reduction techniques to handle the

PS

and to simulate a distributed seismic loading.

The piping system: innovative contributions

(12)

HYBRID SIMULATION OF THE RIO TORTO

BRIDGE

(13)

RC bridge with plain rebars, structural assessment, seismic

retrofitting, hybrid simulation

(14)

7/10/2014 Page 14

MAIN DIMENSIONS OF THE BRIDGE

Total span = 412 m

Single span = 33 m

Taller pier height = 41.50 m, Pier #7

(15)

2 x 12 Friction Pendulum Bearing (FPB)

TRANSVERSAL SEISMIC LOADING

(16)

PHYSICAL SUBSTRUCTURES

(2 Piers + FPB isolation devices)

NUMERICAL SUBSTRUCTURES

7/10/2014 Page 16

(17)

Gerber saddles (removed in the isolated case)

Bologna Firenze

About 900 Degrees-of-Freedom (DoFs)

Element types:

• nonlinearBeamColumn for piers • elasticBeamColumn for the deck

(18)

Bologna Firenze

Materials:

• Kent-Scott-Park model for concrete (Concrete01)

• Menegotto-Pinto model for rebars (Steel02)

• Nonlinear shear behaviour of transverse beam (hysteretic)

singleFPBearing

elements with a

Coulomb frictionModel.

Gerber saddles (removed in the isolated case)

7/10/2014 Page 18

(19)

Hysteretic loops of Pier #11 in the non-isolated case

HYSTERETIC RESPONSES OF OPENSEES PIERS

NONLINEAR NUMERICAL PIERS WERE NEEDED !!!

SLS

ULS

(20)

PHYSICAL SUBSTRUCTURES

(2 Piers + FPB isolation devices)

NUMERICAL SUBSTRUCTURES

SUBSTRUCTURING REQUIREMENTS

(21)

OPENSEES FIBER-BASED FE MODEL:

- CONVERGENCE IS NOT ENSURED;

- HIGH VARIANCE OF SINGLE STEP SOLVING TIME

(NON-DETERMINISTIC).

FROM THE HYBRID SIMULATION PERSPECTIVE:

- TEST CAN FAIL;

- ACTUATORS CAN STOP UNTIL THE NUMERICAL PART IS

SOLVED (MATERIAL RELAXATION IN THE PS)

SUBSTRUCTURING REQUIREMENTS

(22)

7/10/2014 Page 22

DYNAMIC SUBSTRUCTURING OF OPENSEES MODELS

Substructuring scheme and subparts

DECK: LINEAR

PIERS:

LINEAR/NONLINEAR

(23)

Pier #9

CONSTRAINT MODE

CONSTRAINT MODES: static deformation shapes owing to unit displacements applied to boundary DoFs, one by one, whilst the others retained

,

,

T T T

k

=

Τ

KT

m

=

T MT

f

=

T ML

R

R L

=

= ⋅

x

x

T x

x

DYNAMIC SUBSTRUCTURING OF OPENSEES PIERS

GUYAN static condensation:

XR

XL

(24)

7/10/2014 Page 24

( ) ( )

(

2

)

/ 1

(

(

)

) | |

g

n

r

c x

m x

f u

t

p t

r

ρ

k

α

x

β

sgn x r

γ

r

x

+ ⋅ + ⋅ = − ⋅

+



=

+ ⋅

⋅ +

ɺ

ɺɺ

ɺɺ

ɺ

ɺ

ɺ

( )

= transversal force history from OpenSEES;

( )

= input accelerogram;

, ,

,

= linear parameters;

,

α

,

,

γ

,

= nonlinear parameters.

(25)

(

)

( )

(

( )

)

2 , , 1

1

,

max

min

m

i red i OS i red OS OS OS

x

x

m

NRMSE

=

=

x

x

x

x

{

ˆ ˆ

, ,

ˆ

}

min

, ,

(

(

, ,

)

,

)

ˆ

ˆ

1,

0

red OS

NRMSE

n

ρ α β

ρ α β

ρ α β

γ

=

=

=

x

x

XOS = displacement responses of the OpenSEES pier Xred = displacement responses of the S-DOF reduced pier

(26)

7/10/2014 Page 26

F

o

rc

e

[

k

N

]

Displacement [mm]

Bilinear hysteretic model

(27)

Bilinear hysteretic model

(

)

( )

( ) (

)

( ) (

)

(

)

1

m x c x

kx

ku

p t

u

x N x M u

M x N u

α

α

δ

δ

⋅ + ⋅ +

+ −

=



=

− +

+



ɺɺ

ɺ

ɺ

ɺ

ɺ

ɺ

(28)

7/10/2014 Page 28

{

ˆ, ,

ˆ ˆ

}

min

, ,

(

(

, ,

)

,

)

red OS

k

k

NRMSE

k

α δ

α δ

=

r

α δ

r

(

)

( ) (

) ( ) (

)

, ,

, OS, OS,

1

1

red i OS i i

i

i OS j j j j j

j

r

k x

k u

u

N x

M u

M x

N u

x

t

α

α

δ

δ

=

= ⋅ ⋅

+ −

⋅ ⋅

=

− +

+

⋅∆

ɺ

ɺ

ɺ

0.0046,

k

2.0278 8,

e

5.0000

e

4

α

=

=

δ

=

XOS = displacement responses of the OpenSEES isolator Xred = displacement responses of the S-DOF reduced isolator

(29)

Validation of reduced NSs at ULS

VALIDATION OF SUBSTRUCTURED NUMERICAL PARTS

Iso. of Piers #9

Piers #9

D

is

p

la

ce

m

e

n

t

[m

]

Displacement [m]

F

o

rc

e

[

N

]

(30)

7/10/2014 Page 30

HYBRID MODEL OF THE NON-ISOLATED BRIDGE

88-DoFs << ~900-DoFs

(Hybrid model) (OpenSEES RM)

(31)

88-DoFs << ~900-DoFs

(Hybrid model) (OpenSEES RM)

UNIFORM TRANSVERSAL SEISMIC LOADING

(32)

Page 32 10-Jul-14

4 200

400

2

A

t

ss

t

λ

⋅∆

=

=

=

PARTITIONED TIME INTEGRATION

NS

PS

λ

= extended testing time scale = 200

4

A

t

ms

∆ =

2

t

ms

∆ =

200 4

800

A

t

ms

λ

⋅∆ =

⋅ =

Sim. time step:

Exp. time step:

(33)

NS

PS

RESPONSE OF THE NS

PARTITIONED TIME INTEGRATION

4 200

400

2

A

t

ss

t

λ

⋅∆

=

=

=

λ

= extended testing time scale = 200

4

A

t

ms

∆ =

2

t

ms

∆ =

200 4

800

A

t

ms

λ

⋅∆ =

⋅ =

Sim. time step:

Exp. time step:

(34)

(

)

(

)

( )

(

)

( )

1 1

1 1

1 1 1

1

1

1

m n n

n n n

n n n n

n m n m n f n f

n n n

t

t

α α α

γ

γ

α

α

α

α

+ + + + + + + + + +

+

=

=

+ ∆

− +

+

=

+



+

=

My

Ky

f

y

y

v

v

v

v

y

y

My

Ky

f

ɺ

ɺ

ɺ

ɺ

FIRST ORDER

SYSTEMS

USER CONTROLLED

ALGORITHMIC

DAMPING

SELF STARTING

ENERGY PRESERVING

7/10/2014 Page 34

(35)

0

0.05

0.1

-0.01

0

0.01

D

is

p

.

[m

]

0.01

λ

= 128,

t = 1/1024,

t

A

= 1/1024, ss = 128

2

0.01

u

=

Free decay response to:

PS

DoF #1

PS

DoF #2

Time [s]

--

exp.

--

num.

(36)

7/10/2014 Page 36

EXPERIMENTAL SET-UP AT THE ELSA LAB. OF THE JRC OF ISPRA (VA)

(37)

H V

F L

F

B

∆ =

EXPERIMENTAL SET-UP OF PIERS

(38)

7/10/2014 Page 38

1:2.5 SCALE MOCK-UP ISOLATORS

EXPERIMENTAL SET-UP OF ISOLATORS

(39)

EXPERIMENTAL EQUIPMENT

P

I

ER

#

9

P

I

ER

#

1

1

I

S

O

#

9

I

S

O

#

1

1

: Vertical actuator (12x) in force control mode;

(40)

PHYSICAL PIERS

NUMERICAL PIERS

NEED FOR AN UPDATING STRATEGY FOR NUMERICAL PIERS

7/10/2014 Page 40

(41)
(42)

Disp. [mm]

7/10/2014 Page 42

MODEL UPDATING OF OPENSEES FE MODEL OF PHYSICAL PIERS

{ }

ˆ

min

(

( )

,

exp

)

pc

pc OS pc

f

f

=

NRMSE

r

f

r

OpenSEES FEM of Pier #11

ULS RESPONSE

Test k09

Maximum compressive strength of

concrete01

f

pc

--

OpenSEES.

--

experimental

F

o

rc

e

[

N

(43)

MODEL UPDATING OF THE OPENSEES RM OF THE BRIDGE

Pier #9

Pier #11

Hollow piers

(44)

7/10/2014 Page 44

( ) ( )

(

2

)

/ 1

(

(

)

) | |

g

n

r

c x

m x

f u

t

p t

r

ρ

k

α

x

β

sgn x r

γ

r

x

+ ⋅ + ⋅ = − ⋅

+



=

+ ⋅

⋅ +

ɺ

ɺɺ

ɺɺ

ɺ

ɺ

ɺ

{

ˆ ˆ

, ,

ˆ

}

min

, ,

(

(

, ,

)

,

)

ˆ

ˆ

1,

0

red OS

NRMSE

n

ρ α β

ρ α β

ρ α β

γ

=

=

=

x

x

XOS = displacement responses of the UPDATED OpenSEES RM Xred = displacement responses of the reduced pier

(45)

1) Test k06: non-isolated bridge at SLS (10% PGA)

2) Test k07: non-isolated bridge at SLS

3) Test l01: isolated bridge at SLS

4) Test l02: isolated bridge at ULS

5) Test k09: non-isolated bridge at ULS

6) Test k11: non-isolated bridge at ULS (after shock)

(46)

7/10/2014 Page 46

NON-ISOLATED BRIDGE AT SLS

(47)

Pier #9, SLS Pier #9, ULS

Pier #11, SLS Pier #11, ULS

HYSTERETIC LOOPS OF PHYSICAL PIERS

(48)

7/10/2014 Page 48

DAMAGE PATTERN AFTER ULS TESTS

Column ends uplifting, expulsion of concrete covers

(49)

EVOLUTIONS OF MAIN BRIDGE EIGENFREQUENCIES

(50)

7/10/2014 Page 50

COMPARISON OF NUMERICAL RESPONSES TO PHYSICAL MEASUREMENTS

Hysteretic loops and dissipated

energies of Piers #9 and #11

Pier #9, ULS

Pier #11, ULS Pier #9, ULS

(51)
(52)

Table Characteristics of the piping system

Pipe Size Material Liquid/Internal

Pressure

8” and 6” Schedule 40

API 5L Gr. X52

fy= 418 Mpa; fu = 554 Mpa; Elongation = 35.77%

Water/ 3.2 MPa

A 3D model of the piping+support Dimensions and specifications of the piping

7/10/2014 Page 52

(53)

#1

#2

,

,

N P N P N P

x x y y z z

θ

θ θ

θ θ

θ

ANSYS REFERENCE MODEL (RM) OF THE PIPING

X

Positions of minimum bending moments were chosen as coupling nodes.

The seismic action was applied the x direction.

(54)

7/10/2014 Page 54

EXPERIMENTAL SET-UP OF THE PS

A pair of hydraulic actuators imposed displacements to coupling DoFs

(55)

Numerical-DoFs

Boundary-DoFs

Physical-DoFs

DOFS PARTITIONING

(

)

T T T T T T T T T T T B P P P N N g T N P B B u=     =   = = − + ⋅ ⋅    u r f u r

f M M I

u u f r f 0 ɺɺ Displacement vector

Restoring force vector

External load vector

(56)

A reduction basis

T

reflects a kinematic assumption:

N N B B P

= ⋅

u

u

u

T

u

u

T T T P P P P P P g

u

=

=

= −

M

T M T

K

T K T

f

T M I

ɶ

ɶ

ɶ

ɺɺ

Reduced matrices of the PS:

REDUCTION BASIS REQUIREMENTS

(57)

X: time history responses of the PS, i.e. B- and P-DoFs, arranged in row-wise.

U: orthonormal matrix of eigenvectors of XXT.

V: orthonormal matrix of eigenvectors of XTX.

Σ: diagonal matrix of the singular values of X, sorted in descending order. X1

X2

X3

X4

XM XM-1

1

...

T

M

=

=

X

X

U

Σ

V

X

The Principal Component Analysis (PCA) was applied to the dynamic

(58)

Σ

11 >

Σ

22 > … >

Σ

ii: singular values of

X

in descending order

= ∑

Σ

: total data energy

= ∑

Σ

: normalized cumulative data energy

rank two;

span principal component

subspace;

entail consistent kinematic

assumptions.

REDUCTION BASIS REQUIREMENTS

(59)

N N B B CB P q

=

u

u

u

T

u

u

u

S

I

Φ

D

0

Φ

CB S D

=

I

0

0

T

0

I

0

0

Φ

Φ

Constraint modes: static deformation shapes owing to unit displacements applied to B-DoFs, one by one, whilst the other retained

Fixed interface vibration modes: eigenmodes of the PS constrained at its B-DoFs

Additional modal coordinates

(60)

,

,

N

B P r B P

BB

q P r q

qq

 

 

=

=

 

 

  

 

0

0

0

0

u

r

0

K

0

u

K

u

r

0

0

K

u

ɶ

ɶ

u=1

u=1

STATIC AND DYNAMIC CONTRIBUTIONS ARE PLEASANTLY UN-COUPLED !!!

Constraint mode contribution Experimentally measured

Fixed interface vibration mode contribution Numerically modelled

7/10/2014 Page 60

(61)

Errors between time history responses of the

Reduced Model (NS + Reduced PS) and Reference Model

Error Coupling DoF #1 Coupling DoF #2 NRMSE 0.003 0.001

NEE 0.006 0.001

RM 2 2

CM 2

NEE = xxCM

x

( )

( )

RM CM 2

CM CM NRMSE max min N − = − x x x x

X: response signal

Sensitive to frequency mismatching

Sensitive to amplitude mismatching

(62)

[

R L

]

RNRB LNLB RP LP

=

=

Φ

Φ

Φ

Φ

Φ

Φ

Φ

Φ

Φ

1 SE RP RB

=

I

T

Φ Φ

where:

Φ

: mass normalized eigenvectors of the global system (column-wise)

Φ

R

: retained eigenmodes

Φ

L

: truncated eigenmodes

With relevant N-DoFs, B-DoFs and P-DoFs components (row-wise)

N N B SE B P

=

u

u

u

T

u

u

7/10/2014 Page 62
(63)

Errors between time history responses of the

Reduced Model (NS + Reduced PS) and Reference Model

Error Coupling DoF #1 Coupling DoF #2 NRMSE 0.015 0.0016

NEE 0.069 0.0003

RM 2 2

CM 2

NEE = xxCM

x

( )

( )

RM CM 2

CM CM NRMSE max min N − = − x x x x

X: response signal

N: length of response signal in sample

THE SEREP METHOD APPLIED TO REAL-TIME HYBRID SIMULATION

Sensitive to frequency mismatching

(64)

Test Case PGA (g)

Identification test of the PS, IDT Hammer Test

-Real time tests 1 RTDS 0.020 Real time tests 2 RTDS 0.020 Elastic test, ET PDDS 0.042 Operational limit state test, SLOT PDDS 0.079 Damage limit state test, SLDT PDDS 0.112 Safe life limit state test, SLVT PDDS 0.421 Collapse limit state test, SLCT PDDS 0.599

EXPERIMENTAL PROGRAM

7/10/2014 Page 64

• Identified damping = 0.5%;

• Time scale factor

λ =

50;

• Water pressure = 3.2MPa.

(65)
(66)

7/10/2014 Page 66 MOOG hydraulic actuator pair

(67)

0 2 4 6 8 10 -6 -4 -2 0 2 4 6x 10

-3 node 114 dir 1

time [s] d is p . [m ] exp num

Displacement responses at the Coupling DoF #1 and relevant errors w.r.t. numerical simulations.

Error Coupling DoF #1 Coupling DoF #2 NRMSE 0.038 0.066

NEE 0.112 0.396

EXPERIMENTAL VALIDATION OF THE CRAIG-BAMPTON-BASED APPROACH

APPLIED TO THE PSEUDODYNAMIC CASE

X d is p la ce me n t [m]

(68)

2 3 4 5 6 7 8 9 10 11 12 -8

-4 0 4 8x 10

-3 time [s] d is p . [m ] num exp

Displacement responses at the Coupling DoF #1 and relevant errors w.r.t. numerical simulations.

Real-time case ET, PGA = 0.020g

Error Coupling DoF #1 Coupling DoF #2 NRMSE 0.083 0.239

NENERR 0.289 0.379

7/10/2014 Page 68

EXPERIMENTAL VALIDATION OF THE SEREP-BASED APPROACH

APPLIED TO THE REAL-TIME CASE

ANSYS Reference Model

(69)

CONCLUSIONS

THE PARTITIONED TIME INTEGRATION APPROACH WAS APPLIED FOR

THE FIRST TIME TO A COMPLEX BRIDGE PROVIDED WITH

NONLINEAR

NSs

IN BOTH ISOLATED AND NON-ISOLATED

CONFIGURATIONS;

NSs

-NUMERICAL PIERS- WERE UPDATED OFFLINE ACCORDING TO

RESPONSES OF

PSs

-PHYSICAL PIERS- CHARACTERIZED BY

DIFFFERENT SHAPES AND LOADING;

HYBRID SIMULATION WAS APPLIED FOR THE FIRST TIME TO AN

INDUSTRIAL PIPING SYSTEM CHARACTERIZED BY A DISTRIBUTED

PARAMETER

PS

.

BOTH THE CRAIG-BAMPTON AND THE SEREP METHODS WERE

SUCCESSFULLY APPLIED IN THE CASE OF SEISMIC LOADING.

(70)

7/10/2014 Page 70

On the NS side:

-

Development of state space modeling

environments.

-

Possible application of on-line model

updating techniques.

FUTURE PERSPECTIVES

(

(

)

) | |

n
(71)

On the PS side:

-

Experimental validation of alternative reduction bases in the linear

range (balanced truncation, proper orthogonal decomposition, etc.);

-

Extension of the proposed approach to nonlinear PSs.

(72)

7/10/2014 Page 72

Publications on international journals

(accepted, submitted and in preparation):

1. Ceravolo R., Abbiati G., 2012. Time Domain Identification Of Structures: A Comparative Analysis Of Output-Only Methods - International Journal of Engineering Mechanics, 139(4):537-544.

2. Bursi O.S., Abbiati G., Reza Md.S., 2013. A Novel Hybrid Testing Approach for Piping Systems of Industrial Plants. Special Issue of Smart Structures and Systems on ''Recent Advances in Real-time Hybrid Simulation'' (RTHS) - In print.

3. Reza Md.S., Abbiati G., Bursi O.S., Paolacci F., 2013. Seismic performance evaluation of a full-scale industrial piping system at serviceability and ultimate limit states. Journal of Loss Prevention - Under review.

4. Abbiati G., Ceravolo R., Surace C., 2013. Unbiased time-dependent estimators for on-line monitoring of full-scale structures under ambient excitation. Mechanical Systems and Signal Processing - Under review.

(73)

Additional SCOPUS indexed publications:

1. Reza M.S, Abbiati G., Bonelli A., Bursi O.S., 2013. ''Pseudo-dynamic testing of a piping system based on model reduction techniques''. SERIES Concluding Workshop joint with NEES-US Earthquake Engineering Research Infrastructures. JRC Ispra, May 28-30.

2. Abbiati G., Bursi O.S., Cazzador E., Mei Z., Paolacci F., Pegon P., 2013. ''Pseudo-dynamic testing with non-linear substructuring of a reinforced concrete bridge''. SERIES Concluding Workshop joint with NEES-US Earthquake Engineering Research Infrastructures JRC Ispra, May 28-30.

3. Paolacci F., Di Sarno L., Pegon P., Molina F. J., Poljansek M., Bursi O.S., Abbiati G., Ceravolo R., Erdik M., Deisi R., Mohamad A, 2013. ''Assessment of the seismic behaviour of a retrofitted old R.C. highway bridge through PsD testing''. SERIES Concluding Workshop joint with NEES-US Earthquake Engineering Research Infrastructures JRC Ispra, May 28-30.

(74)

7/10/2014 Page 74

Thank you for your attention.

Figure

Table Characteristics of the piping system

References

Related documents

TWO DIMENSIONAL SWITCHED BEAM ANTENNA BASED ON CASCADED BUTLER MATRIX BEAMFORMING NETWORKS. To minimise the surface current, ensure low cost and ease fabrication, a single layer

Generalized linear model confirmed that clinical pregnancy and delivery rates in OHSS patients were significantly higher in frozen embryo trans- fer, 63.1% and 45.6%, compared

For the first and second studies, the objectives were to (i) characterize the Fiskeby III X Mandarin (Ottawa) recombinant inbred line (RIL) population for its tolerance to

The primary endpoint was the correlation between immediate response of forced expiratory volume in 1 s (FEV 1 ) post-inhalation of salbutamol (400 μ g) at study entry and the

Passed time until complete analysis result was obtained with regard to 4 separate isolation and identification methods which are discussed under this study is as

second GnRH treatments of Ovsynch based for 7 d progesterone device insertion are essential for optimal synchronization of a preovulatory follicular wave and

Approximately 20% of cases are a result of meconium inspissations secondary to cystic fibro- sis and 30% result from intestinal atresia or obstruc- Figure 5 : A: Ultrasound followed

Conclusions: Diabetes-related factors such as duration of diabetes, FBG, HbA1c and compliance to self management of diabetes were significantly correlated with periodontal health