BC. 02.03 D2/E

ISO 9001 Certified

E

delta

due

®

series

Control and acquisition modules

with fieldbus

for DIN rail

mounting

Not just I/O modules

Process and Temperature

controllers

Analogue and digital

I/O modules

Transmitters with alarm

thresholds

PROFIBUS DP / DeviceNet /

CANOpen / Modbus TCP/

Modbus RTU fieldbus

Interfaces

• A complete range of compact and flexible modules • PC configurable

• Wide choice of Operator Panels • Built-in RS 485 Modbus

(2)

ASCON’S CONTROL AND ACQUISITION

Modular Multiloop

R

3 YEARS WARRANTY

Dimensions:

w 22.5 x h 99 x d 115 mm

delta

due

®

series

ASCON’s process control experience and the increasing need for integration of the control systems have brought to the development of the new deltadue®series, consisting

in control and acquisition modules.

The deltadue®modules

can either be rear panel or on-machine mounted. This way, control panels can be more compact and distribution on the plant or on the machine can be optimized. The modules are independent. Each module can work as a single unit or within a set of modules as a part of a stand-alone control system, or integrated in PLC or PC systems. Integration into PROFIBUS DP or DeviceNet or CANOpen or Modbus TCP or Modbus RTU is assured by the Gateway modules.

User friendly software assists rapid PC configuration of deltadue®.

A complete range

of modules...

• PID single loop and dual loop controllers with universal input and with time proportioning, valve drive and analogue outputs • Modular Multi loop controllers

up to 31 or more zones • Analogue and digital data

acquisition for: - PC based systems field

interface (front-end) - Expansion of PLCs or other

data processing units.

...compact and flexible...

• Universal input: T/C, RTD

(Pt100), mA, mV, Hz, IR sensors and a special Custom linearisation • Auxiliary power supply

for 2-wire transmitters • Relay, SSR and SSR drive. • Special functions, Start-up,

Timer, etc. • Hot-swapping

(3)

ON MODULES FOR DIN RAIL MOUNTING

• Universal single loop

controllers

• Independent dual loop

controllers

• 1-channel or 2-channel

universal analogue

input modules

• 6 DI plus 2 DO modules

D1, D2, D3

Controllers

D7, D8, D9

Acquisition and

Transmitter modules

DX Manager-Gateway

RS 485

485/232

...open to the external

world...

All modules have RS485 and Modbus protocol for direct connection to most common Operator Panels and SCADAs. Integration into PROFIBUS DP or DeviceNet or CANOpen or Modbus TCP or Modbus RTU by means of the Gateway modules DX and DY.

...with the

“Manager-Gateway”...

The optional DX module includes two important functions

- management of the connected deltadue®

modules for offline configuration, data back up and hot swapping

- serial interface and adaptor for integration on fieldbus.

...with a wide range

of HMIs

The deltadue®series includes

self-configuring HMIs, from simple compact

alphanumeric Operator Panels to Touch Screen Graphic panels. Connected deltadue®

modules are automatically recognized and their configuration uploaded.

SCADA software

for machines

and/or small plants

- Windows environment - Self-configuration for

up to 32 deltadue®and

gammadue®instruments;

simple and flexible - Overview, trend and alarm

pre-formatted pages - Plant synoptics

- Data archiving and report generation.

(4)

PV1 OP1 OP2 PV2 IL1 12 12 12 12

Main universal Inputs

Digital input Setpoint OP3 OP4 Digital outputs Digital outputs

can also be used as digital inputs

Available functions

Not

D1 Line - Temperature controller

D2 Line - Dual loop control/acquisition module

PV AUX IL OP1 OP2 OP3 OP4 12 12 Digital input Fuzzy tuning

with automatic selection

One shot Auto tuning One shot Natural frequency

Fuzzy tuning

with automatic selection

One shot Auto tuning One shot Natural frequency

Fuzzy tuning

with automatic selection

One shot Auto tuning One shot Natural frequency

Main universal Input

Setpoint Special functions Digital input functions

RS485 Modbus Slave

for configuration and supervision purposes

Serial communications

RS485 Modbus Slave

for configuration and supervision purposes

Serial communications

PID CONTROL MODULES

Current transformer

D3 Line - Heat/Cool controller with analogue output

PV OP1 OP2 OP3 OP4 OP5 12 12

Main universal Input

RS485 Modbus Slave

for configuration and supervision purposes

Serial communications

2 + 2

2 + 2

Digital input functions

Every output (OP1...OP4) can be freely combined with the Pv1 or PV2 inputs

IL Digital input Outputs Outputs Auxiliary inputs Digital inputs Analogue output Fuzzy tuning Setpoint Special functions Digital input connected functions Digital outputs Thermocouple RTD Pt100 Delta temperature (2xRTD) mA and mV “Custom” Current transformer Isolated contact NPN open collector TTL open collector Frequency SPST relay SSR PNP open collector SSR drive mA One shot Auto tuning One shot Natural frequency Local Memorised Start-up Timer Auto/Man Memorised setpoint activation PV Hold Alarm acknowledgement Not Toggle Flip-Flop

(5)

5

ACQUISITION MODULES

D7 Line - Analogue acquisition, alarm thresholds and transmitter module

PV IL OP1 OP2 OP5 12 12 Digital input

Main universal Input Outputs (option)

Digital input functions

RS485 Modbus Slave

for configuration and supervision purposes

Serial communications

DO1

DO2

Digital inputs Output

D8 Line -Digital I/O acquisition module with 6 Inputs and 2 Outputs

RS485 Modbus Slave

for configuration and supervision purposes Serial communications DI1 DI2 DI3 DI4 DI5 DI6 Available functions

Not Toggle Flip-Flop Available functions PWM Hold Not PV1 OP1 OP2 PV2 IL1 12 12 12 12

Main universal Inputs

Digital input

OP3

OP4 Digital outputs

Digital outputs

can also be used as digital inputs

Available functions

Not

D9 Line - 2-channel analogue acquisition module

RS485 Modbus Slave

for configuration and supervision purposes

Serial communications

Digital input functions

Every output (OP1...OP4) can be freely combined with the Pv1 or PV2 inputs

(6)

ARCHITECTURES AN

Plastic and Rubber: Injection, Extrusion,

Hot-Runners

Packaging: Thermowelding, Thermoforming

Food: Dairy products, Food Packaging,

Bottling, dried and fresh Pasta, oven Products, cereal Silos, preserving-ripening stores

Vehicles: engine testing Counters,

painting Plants, plate welding Plants

Ceramic and Brick Works: continuous

Furnaces, intermittent Furnaces, Driers

Industries and Applications

Modular multiloop

PID controller with local

Operator Panel interfaced

with remote SCADA.

Distributed I/O modules

for acquisition,

data logging

and centralised

supervision of analogue

and digital signals with

the possibility of alarms

and local commands.

Modular multiloop

PID controller with

local Operator Panel.

Distributed control

and acquisition system with

DX module (manager and bus

interface) for hot swapping

and connection to local

Operator Panel and remote

SCADA.

HMI/SCADA Modbus PLC Modbus Modbus DX DX

(7)

AND APPLICATIONS

Metal Works: blast Furnaces,

thermal treatment Furnaces

Glass: blast Furnaces; Furnaces for the

treatment of flat, hollow, curved glass

Chemistry and Pharmaceutics:

Fine chemistry, Pharmaceutics, Cosmetics, Paints and Enamels

Power: Boilers, Burners

Industrial Air Conditioning and

Refrigeration: climatic Chambers, Chillers Shipyards: hull Automation

Water Treatment: waste Waters,

Primary Waters, Semi-Conductors.

Integration of PLC

systems with external

distributed PID controls

and I/O modules.

Distributed I/O modules

for PC based sytems.

Control and acquisition

modules with DX fieldbus

interface module.

PLC PLC PROFIBUS / DeviceNet Modbus Modbus DX

(8)

Distributor: The specifications in this document may therefore be changed without notice -Modbus ®is a trademark of AEG Schneider Automation

DX - Manager-Gateway Line

The DX module has 3 serial ports and includes two important functions: - Manager

- Gateway.

The “Manager” memorises the configuration and parameters of each module and monitors that the latter functions correctly. Any time a module is substituted, this is recognised by the DX-Manager, which

automatically reconfigures and parametrises

the substituted module. The Gateway includes: one fieldbus slave port for the conversion Modbus/PROFIBUS DP, Modbus/DeviceNet and Modbus RTU/Modbus RTU; two RS485 Modbus Master ports for the connection to the deltadue®modules

and to other Ascon’s,

or other manufacturer’s, devices; one RS485/RS232 Modbus Slave port for the connection to Operator Panels, Supervision PCs and for the configuration of the deltadue®modules via PC.

PROFIBUS / DeviceNet / Modbus RTU

DX Manager Gateway

Modbus for configuration and/or supervision

Modbus

Bus for other devices

ASCON spa

Via Falzarego, 9/11 20021 Baranzate (Milano) Italy Tel. +39 02 333 371 Fax +39 02 350 4243 http://www.ascon.it sales@ascon.it

ASCON FRANCE

2 bis, Rue Paul Henri Spaak ST.THIBAULT DES VIGNES F-77462 LAGNY SUR MARNE - Cedex Tél. +33 (0) 1 64 30 62 62 Fax +33 (0) 1 64 30 84 98 www.ascon.fr ascon.france@ascon.fr AGENCE EST Tél. +33 (3) 89 76 99 89 Fax +33 (3) 89 76 87 03

ASCON

CORPORATION

1884 East Fabyan Parkway Batavia, Illinois 60510 Tel. +1 630 482 2950 Fax +1 630 482 2956 www.asconcorp.com info@asconcorp.com WORLDWIDE NETWORK OF DIRECT SALES CENTRES, DISTRIBUTORS AND VARs

Europe

Belgium, Croatia, Czech Rep., Denmark, Esthonia, Finland, France, Germany, Great Britain, Greece, Holland, Ireland, Norway, Poland, Portugal, Romania, Russia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey, Ukraine

Americas

Argentina, Brazil, Canada, Chile, Colombia, Ecuador, Paraguay, Peru, Urugay, Venezuela

Rest of the world

Algeria, Australia, China, Egypt, Hong Kong, India, Indonesia, Iran, Israel, Malaysia, Marocco, New Zeland, Pakistan, Saudi Arabia, Singapore, Taiwan, Thailand, Tunisia, South Africa & South East Africa, UAE

PLC

References

Related documents

235. WATER CODE ANN.. ing why addressing chemicals and pesticide regulation through information disclosure is a fool's errand, helps underscore two fundamental points:

In a given image sequence showing the eye region motion with small head movements, tracking consists of estimating the eyelid and iris positions in 3D for each frame.. Therefore,

The TecFour has four analogue or digital inputs and the additional ultrasonic sensor input, the TecTrio has three analogue or digital inputs and four outputs suitable for control

Models for cost- benefit calculations and risk assessments documented the strong influence of negative attitudes towards immigration, as well as effects of the perceived loss

For the remaining four cases, overlap area is determined by combining the areas of appropriate segments and polygons in each ellipse, based on the position of transverse

In my experiences working with death row inmates and their families, the added retributive power of a death sentence over and above LWOP usually impacts his family, and other

Tip in the bean sprouts and, leaving the heat on high all the time, slide the wok scoop or metal spatula to the bottom of the wok and then turn and vigorously toss the bean

Not much information is available as to bronze or brass in fuzes being replaced by other metals ; it will be seen, however, that the 1908 pattern time and percussion fuze is now