• No results found

CHAPTER CONTENT PAGE. Hybrid: The perfect solution for all systems. Explanation of the - Heat Exchanger 4. Finishes 12

N/A
N/A
Protected

Academic year: 2021

Share "CHAPTER CONTENT PAGE. Hybrid: The perfect solution for all systems. Explanation of the - Heat Exchanger 4. Finishes 12"

Copied!
16
0
0

Loading.... (view fulltext now)

Full text

(1)
(2)

Index

CHAPTER CONTENT PAGE

Introduction

Hybrid:

The perfect solution for all systems

3

Explanation of the

- Heat Exchanger

4

Advantages

5

Summer mode

6

Winter mode

7

Range of products

Adaptative

Hybrid 50 and 100

8 - 9

Fan/ Timer

10

Measures and Fixing/Pressure loss

11

Finishes and references

Finishes

12

References

13

Electric Series

SMART bathroom series

14

Environments

One finish for each environment

15

The perfect solution

for all heat pump

systems

or low-temperature boilers.

Get the best of the traditional boilers and improve the efficiency and versatility of the heaters.

Inertial Heating at Low-Temperature, immediate response

MAXIMUM COMFORT

(3)

Hybrid

DK Hybrid Adaptative 100 Blanco Siclicio (Ref. 05A100H)

1st

It works with water systems at low temperature and includes a heating element independently managed.

2nd

Designed for heating and cooling purposes.

A challenge for high-efficient energy heating systems

The most eco-friendly heating systems -those of high energy efficiency or those using new energy sources- work with low or very low water flow temperature. Water temperature reaches 85ºC in traditional heating systems whereas low temperature systems reach 35-60ºC

This is the case with the new condensing boilers –high output and low CO2 and NOx emissions-, heat pumps, geothermics

or solar heating panels. All these systems, on working at low temperature, guarantee energy savings and reduce thermal losses. Output improves.

Why

Hybrid

is a hybrid system?

100% ecologic

Up to 75% savings

100% versatile

Instant reaction

3rd

It may work both as a static and as a dynamic device

(4)

FOREV

ER

LIFE -GUARANTEE ONDUAL-KHER R

Silicium

Patented System

► system optimizes its performance thanks to its Double Core. This double code is made of silicon oxide and aluminium oxide, two complementary compounds that provide an extra value to our heating system. Silicon is an excellent heat accumulator while aluminium is an outstanding heat conductor. Thereby, we guarantee the best heat transfer from convection current to the storage component; heat radiation and accumulation improve.

Heat transfer to the room is made by radiation and convection (natural or forced, depending on the version) by passing the air through the aluminium fins.

The new double-circuit exchanger provides exceptional performance. Thermal inertia improves if compared to a traditional exchanger.

(5)

Hybrid

Low energy

consumption

Dual-Kherr hybrids use 5-15% less energy than an installation with traditional radiators. They heat quickly to the desired temperature. The forced ventilation system included may increase savings up to 30%

Low water content (0.8 and 1.6 litres) helps high reaction speed. The quicker water heating is the quicker heat transfer is.

Faster warming

Heat transfer with

water at 32ºC

Movable slats:

True heat and cold wherever you want

Movable slats

True heat and cold wherever you want.

Immediate heat

Perfect power adjustment

Combinable or alternative

option to radiant floor

No leakage risk and immediate response to your needs

Large heat interchange

surface: up to 3.56m2 on a

single device.

(6)

One unique system for all your needs

The perfect combination for reversible heat pumps.

Pleasant temperature in summer months. An alternative to conventional air

conditioning systems.

Summer mode

1. Free-cooling mode:

cross-flow fans are activated; the air circulates and the room cools down. Wind-chill temperature is up to -5ºC, with any type of boiler and without the use of cold water supply.

2. Cooling mode:

this makes possible to get the best of the reversible heat pumps as efficient cooling systems and as an alternative to air conditioning.

(7)

Hybrid

Summer mode

Best comfort during winter months. The quickest and most flexible heating system,

the best energy saving.

Winter mode

Hybrid may work in:

1. Static mode

, heat exchanger as heat source by natural convection.

2. Dynamic mode

, with a cross-flow fan electronically controlling forced flow-heat.

3. Adaptative mode

, forced-flow heat together with a low-consumption heating element –only 200 or 400W-, independently and manually controlled. Energy consumption, maximum wind-chill factor.

► One single button to program the fan: PLUS, COMFORT and ECO.

(8)

9 The perfect solution for all systems: heat pumps, low-temperature boilers and conventional boilers.

9 Two sizes suit all customer needs.

9 Winter and summer mode

9 3 operating systems: Static, Dynamic and Adaptative

9 Less energy consumption

9 Faster warming.

9 Heat transfer with water at 32ºC.

9 Add towel bars to turn it into a towel warmer.

DK Hybrid Adaptative

Power upto

3590W

3 operating modes: Static Dynamic Adaptative Inlet 75ºC in adaptative mode Silicium accumulator DUAL KHERR

Inlet temperature ºC 35 45 55 65 75 Sound

level*

Water flow l/m 3 4 5 6 3 4 5 6 3 4 5 6 3 4 5 6 3 4 5 6

Natural convection

100% silent 93 101 109 117 213 222 230 239 296 321 352 379 368 407 469 526 412 469 517 588

Very quiet mode (V1) 238 257 276 294 465 497 527 559 597 654 701 756 667 726 791 856 776 828 890 947 23 dB

Quiet mode (V2) 342 361 379 401 594 627 661 694 765 811 869 921 926 989 1046 1103 1076 1139 1201 1259 24 dB

Average value V2 542 561 579 601 794 827 861 894 965 1011 1069 1121 1126 1189 1246 1303 1376 1339 1401 1459 24 dB

Booster mode (V3) 451 476 501 528 788 823 866 902 984 1054 1112 1176 1142 1226 1312 1398 1322 1416 1509 1603 46 dB

Extra mode 651 676 701 728 988 1023 1066 1102 1184 1254 1312 1376 1342 1426 1512 1598 1522 1616 1709 1803 46 dB

Power W. Adaptative DK Hybrid 50x50

B

C

Inlet temperature ºC 35 45 55 65 75 Sound

level*

Water flow l/m 3 4 5 6 3 4 5 6 3 4 5 6 3 4 5 6 3 4 5 6

Natural convection

100% silent 190 206 222 246 351 379 424 462 501 542 607 651 612 698 753 866 720 801 906 1018

Very quiet mode (V1) 389 435 483 522 760 846 938 1007 1155 1265 1386 1496 1276 1412 1562 1671 1390 1562 1732 1860 21 dB

Quiet mode (V2) 548 602 675 723 1082 1179 1261 1335 1470 1562 1674 1802 1788 1901 2012 2099 2142 2232 2310 2406 24 dB

Average value V2 948 1002 1075 1123 1482 1579 1661 1735 1870 1962 2074 2202 2188 2301 2412 2499 2542 2732 2710 2806 24 dB

Booster mode (V3) 802 866 935 1016 1502 1589 1712 1860 2146 2231 2421 2573 2464 2613 2808 2967 2755 2904 3088 3190 44 dB

Extra mode 1202 1266 1335 1416 1902 1989 2112 2260 2546 2631 2821 2973 2864 3013 3208 3367 3155 3304 3488 3590 44 dB

Power W. Adaptative DK Hybrid 100x50

B

(9)

Hybrid

Simple and efficient. Multi-power adaptative devices.

What device do I need?

Check the Green Guide:

1. Depending on the climate zone, select the power you need, charter

A

2. To get the output of your device, select the water inlet temperature of your boiler or heat pump,

(

B)

3. Power selected in charter

A

should be inferior or equal to the average value in

C

Depending on the power, choose DK Hybrid 100 or DK Hybrid 50. So easy! Two unique devices to meet your needs.

m2 9 12 15 18 21 24 27 30 Climate Mild 400 600 800 1000 1200 1400 1600 1800 Warm 500 700 1000 1300 1600 1900 2000 2100 Cold 600 900 1200 1500 1800 2000 2200 2400 Very Cold 700 1000 1300 1600 1900 2100 2300 2600 Extremely Cold 800 1100 1400 1700 2000 2300 2600 2900

Estimate power

(according to local climate and m2 (W) and height 2,70 m).

Inlet temperature ºC 35 45 55 65 75 Sound

level*

Water flow l/m 3 4 5 6 3 4 5 6 3 4 5 6 3 4 5 6 3 4 5 6

Natural convection

100% silent 93 101 109 117 213 222 230 239 296 321 352 379 368 407 469 526 412 469 517 588

Very quiet mode (V1) 238 257 276 294 465 497 527 559 597 654 701 756 667 726 791 856 776 828 890 947 23 dB

Quiet mode (V2) 342 361 379 401 594 627 661 694 765 811 869 921 926 989 1046 1103 1076 1139 1201 1259 24 dB

Average value V2 542 561 579 601 794 827 861 894 965 1011 1069 1121 1126 1189 1246 1303 1376 1339 1401 1459 24 dB

Booster mode (V3) 451 476 501 528 788 823 866 902 984 1054 1112 1176 1142 1226 1312 1398 1322 1416 1509 1603 46 dB

Extra mode 651 676 701 728 988 1023 1066 1102 1184 1254 1312 1376 1342 1426 1512 1598 1522 1616 1709 1803 46 dB

Cool mode Sound

level* Inlet temperature 16ºC 19ºC 7ºC 12ºC

Natural Convection

100% silent 82 174 0 dB

Very Quiet mode (V1) 266 507 23 dB

Quiet mode (V2) 310 648 24 dB

Booster mode (V3) 452 776 46 dB

Inlet temperature ºC 35 45 55 65 75 Sound

level*

Water flow l/m 3 4 5 6 3 4 5 6 3 4 5 6 3 4 5 6 3 4 5 6

Natural convection

100% silent 190 206 222 246 351 379 424 462 501 542 607 651 612 698 753 866 720 801 906 1018

Very quiet mode (V1) 389 435 483 522 760 846 938 1007 1155 1265 1386 1496 1276 1412 1562 1671 1390 1562 1732 1860 21 dB

Quiet mode (V2) 548 602 675 723 1082 1179 1261 1335 1470 1562 1674 1802 1788 1901 2012 2099 2142 2232 2310 2406 24 dB

Average value V2 948 1002 1075 1123 1482 1579 1661 1735 1870 1962 2074 2202 2188 2301 2412 2499 2542 2732 2710 2806 24 dB

Booster mode (V3) 802 866 935 1016 1502 1589 1712 1860 2146 2231 2421 2573 2464 2613 2808 2967 2755 2904 3088 3190 44 dB

Cool mode Sound

level* Inlet temperature 16ºC 19ºC 7ºC 12ºC

Natural Convection

100% silent 169 396 0 dB

Very Quiet mode (V1) 503 967 21 dB

Quiet mode (V2) 609 1195 24 dB

Booster mode (V3) 860 1566 44 dB

A

* Sound level obtained at 1,5 m away from the floor and at 3 m away from the device.

(10)

Fan

5 Options

Natural convection. 100% silent Air speed 1 3km/h. Very Quiet Air speed 2 5km/h. Quiet

Air speed 3 8km/h. Booster mode Booster mode with additional power Temperature room range and operating flexibility of DUAL-KHERR HYBRID

(Tested at ∆ 40ºC)

Timer

► Timer function: program the fan with one button. 7 available options: 1h, 4h, 5h, 8h, 9h, 12h or 13h. The fan works as per the time and programme selected (plus, comfort or eco).

• Best comfort with the replay timer (see picture). Choose the interval time you prefer, press the button for a few seconds, the fan will automatically work and stop in equal intervals as defined.

00:00 07:00 19:00 Time Consumption Temperature 21°C 18°C ON OFF OFF 12:00 16:00 20:00 24:00 4:00 8:00 12:00 Time Consumption Temperature 21°C 19°C

ON OFF ON OFF ON OFF

► ... 12 h Replay, the fan works, whenever it is necessary and at the speed selected, from 7a.m. to 7p.m., and is off from

7p.m. to 7a.m. Ideal for offices, schools,…(see graphs).

► ... 4 h Replay, programme the fan at 12 a.m. and ensure maximum comfort at lunch time (12a.m.-4p.m.), at night (8p.m.

at noon) and at wake-up time (4am-8am). This distribution corresponds to most householders in weekly working hours. (See graphs).

e.g.

Customize it yourself!

Natural Convection

Temperatur e (ºC) Time (s)

(11)

Hybrid

5 Options

Natural convection. 100% silent Air speed 1 3km/h. Very Quiet Air speed 2 5km/h. Quiet

Air speed 3 8km/h. Booster mode Booster mode with additional power

45 mm

410 mm

55 mm

117 mm

outlet

intlet

Measures and Fixing

Hybrid 50x50 Hybrid 100x50 A (mm) 500 1000 B (mm) 540 540 C (mm) 440 870 9 Hidden connections

A

B

0,05 0,1 0,15 0,2 0,25 0,3 0,35 0,4 0,45 mca

Heat exchanger pressure loss

DK Hybrid 100

► Optional thermostatic valve Regulates the hot water inlet, and the room temperature.

*

The drain is only necessary with reversible heat pumps

Technical details:

Model Length x Height x DepthMeasures mm. (dry weight)Kg Water volume Extra mode Fan Heat exchanger connections

DK Hybrid 50 500x500x118 20 0,8 L 200 W 40 W 1/2”

Dk Hybrid 100 1000x500x118 30 1,6 L 400 W 40 W 1/2”

Heat exchanger

Wall supports (mm)

(12)

White Slate (code 01)

Finishes

Black Slate (code 02)

Imperial Limestone (code 03)

White Limestone (code 04)

White Cashmere- Mimetic (code 05)

Travertine (code 06)

Oak (code 07)

Wengue (code 08)

Mencía 001 (Code 12)

Future (Code 13) Niñez (Code 14)

(13)

Hybrid

Finish Adaptative DK Hybrid 50 Adaptative DK Hybrid 100

Reference Reference

White Cashmere-Mimetic

05A050H

05A100H

White Slate

01A050H

01A100H

White Limestone

04A050H

04A100H

Black Slate

02A050H

02A100H

Imperial Limestone

03A050H

03A100H

Travertine

06A050H

06A100H

Oak

07A050H

07A100H

Wengue

08A050H

08A100H

Valderoma Artistic Collection

Reference Reference

Mencía

12A050H

12A100H

Niñez

14A050H

14A100H

Future

13A100H

Niza

15A100H

References

Mimetic

9 White Cashmere finish –mimetic- has been developed in silky texture and minimalist design to help match into any background.

9 Thus, the device is designed for being painted in the colour and texture you wish. Apply first a primer coat to ensure the paint adheres correctly to a surface WITHOUT ABSORPTION OF WATER and resists temperatures up to 70ºC. Check with a paint shop.

(14)

Adaptative DK Hybrid 100 Black Slate (ref. 02A100H)

Adaptative DK Hybrid 100 White Cashmere- Mimetic (ref. 05A100H) Adaptative DK Hybrid 100 Mencía (ref. 12A100H)

(15)

Electric bathroom series

9

Electronic thermostat

9

Programmable. On/off time control

9

Easy to use. Complete control with only 2

buttons.

9

Back frame made of high quality steel

9

Anti-frost function

Power

Smart Format LxHxDMeasures and weight Weight

800 W Square 50X50X7 cm 10,35 kg

800 W Vertical 50X100X10,5 cm 20,20 kg

Stainless Steel Bar.Ref. BT050X5 Towel Warmer Imperial Limestone 800 W. Ref. CI08SLS

Low energy consumption,

the perfect complement

for DK Hybrid

Depth

Weight 5 cm 8 cm

SST Towel Bars 51 cm BT050X5 BT050X8 0,50 kg SST Towel Bars 102 cm BT100X5 BT100X8 0,85 kg

(16)

Carretera As-266 / Oviedo - Porceyo, Km. 7 Pruvia

33192 Llanera (Asturias) Spain

Tel . +34 985 66 80 80

Fax: +34 985 26 47 51

www.climastar.es

[email protected]

References

Related documents

In order to probe whether the influence of the Affect Module on altruistically motivated prosocial behaviour was further modulated by the preceding training, that is, whether Affect

The public policy objectives of the NHA MBS and CMB programs are to “contribute to the effi cient functioning, competitiveness, and stability of the housing fi nance system by

Some resources available in Colorado today support the professional development of educators to address mental health needs of children, provide positive behavioral supports,

Methotrexate loaded PEGylated carbon nanotubes were prepared by functionalization of MWCNTs effectively with drug loading capacity of about 2.26 mgs of MTX per mg

Failure of the oral examination will result in failure of the rotation and the student will need to retake the OB/Gyn clinical rotation and retake the NBOME-COMAT following

Open Deck Chart room Radio room Office r Chief Engineer Captain Hotel manager´s office Balconies Balconies Sta ff Cabin Sta ff Cabin Coffee Station Promenade deck Promenade

The repeated use of price and wage controls is likely to destabi- lize inflation in the medium run. The similar cyclical pattern of inflation observed in the aftermath of the