• No results found

NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution

N/A
N/A
Protected

Academic year: 2021

Share "NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution"

Copied!
32
0
0

Loading.... (view fulltext now)

Full text

(1)

Super Solution

(2)

Super Solution

Low voltage

circuit breakers

Susol L

V

cir

cuit br

eakers

(3)

Overview

Electrical characteristics

Trip units

Accessories

Technical information

Characteristics curves

Overall dimensions

4

10

11

12

19

20

22

Contents

Contents

Design for technical strong point: The Susol MCCB

SuSol Series MCCB is available forworld best breaking capacity up to

150kA, and MS is seal structure for hidden electricity Arc.

SuSol product represents simultaneously simple and complicated

design for using cut diamond motive to emphasis on the hardness of

industrial product.

And we applied the identity of product image by designing same concept

MCCB and MS which is installed to cubicle.

SuSol Series acquire the competitive power through getting the picking

up GD product and wining IF Design Award.

(4)

Super

Performance

Super

Breaking capacity

Super

Optimum coordination

Super

Extensive applications

(5)

TE series

New member of Susol MCCBs

New borning of 160AF

The fifth frame TE100, TE160

Small, but Big benifit

More compact and less cost

TE100

In : 16~100A (fixed )

Icu : 37kA(S), 50kA(N), Ics=Icu

3 and 4 pole

76(W) x 130(H) x 82mm(D)

TE160

In : 100~160A (fixed or thermally adjustable)

Icu : 37kA(S), 50kA(N), Ics=Icu

3 and 4 pole

(6)

TE100/160

In 16~160A

Icu : 37kA(S), 50kA(N)

Ics=Icu

76(W) x 130(H) x 82mm(D)

Susol TD, TS, TE circuit breakers are rated from 16 to

800 amperes and are available in four frame sizes.

MCCB

TS800N TS800H TS800L 150kA TS630N TS630H TS630L TS400N TS400H TS400L TS250N TS250H TS250L TS160N TD160N TS160H TD160H TS160L TD160L 100kA 85kA 65kA 50kA 37kA 100A 160A 250A 400A 630A 800A

Breaking capacity Icu at 380 / 415V (kA)

Rated current, In (A)

50kA

37kA

85kA

100kA

65kA

150kA

TS100N TD100N TE160STE100S TE160N TE100N TS100H TD100H TS100L TD100L

(7)

In 700, 800A

Icu: 65kA(N), 100kA(H), 150kA(L)

Ics=Icu

210(W) x 320(H) x 135mm(D)

TS800

TS400/630

TS100/160/250

In 300~630A

Icu: 65kA(N), 85kA(H), 150kA(L)

Ics=Icu

140(W) x 260(H) x 110mm(D)

In 40~250A

Icu: 50kA(N), 85kA(H), 150kA(L)

Ics=Icu

105(W) x 160(H) x 86mm(D)

Super Performance

28 models in 5 frames

TD100/160

In 16~160A

Icu : 50kA(N), 85kA(H), 150kA(L)

Ics=Icu

(8)

MCCB

Flexibility through modularity

Susol series offer various and compatible accessories which are providing

simple installation and easy upgrading of the circuit breaker. Harmonization

of the accessories allows stock reduction and greater service flexibility.

(9)

� � � � �

� � � � � � � �

Circuit breaker

Insulation barrier

Terminal cover(short, long)

Connection terminals

Direct rotary handle

Extended rotary handle

Electrical auxiliaries

Mechanicla interlock device

(10)

Electrical characteristics

10

TE100

TE160

Frame size [AF] Rated current In [A] No. of poles

Rated operational AC [V] voltage, Ue DC [V] Rated impulse withstand voltage, Ui [V] Rated ultimate short-circuit breaking capacity, Icu

AC 50/60Hz 220/240V [kA] 380/415V [kA] 440/460V [kA] 480/500V [kA] 600/690V [kA] DC 250V [kA] DC(2poles in series) 500V [kA] Rated service breaking capacity, Ics [%Icu] Rated ultimate short-circuit making capacity, Icm

AC 50/60Hz 220/240V [kA] 380/415V [kA] 440/460V [kA] 480/500V [kA] 600/690V [kA] Category of utilization Isolation behavior Trip unit(release) Thermal magnetic

●fixed-thermal, fixed-magnetic FTU

●adjustable-thermal, fixed-magnetic FMU

●adjustable-thermal, adjustable-magnetic ATU

●magnetic only MTU Electronic

●LSI ETS

●LSI ETM Option Earth-fault protection, lg

Zone selective interlocking, 'ZSI Ammeter

Communication

Earth-leakage protection module Connection Fixed front-connection

rear-connection Plug-in front-connection rear-connection

Mechanical Life [operations] Electrical life @ 415V AC [operations] Basic dimensions, WxHxD 3-pole [mm] (front connection) 4-pole [mm] Weight 3-pole [kg] (front connection) 4-pole [kg] Reference standard 100 160 16~100 100,125,160 3,4 3,4 690 690 500 500 8 8 S N S N 50 85 50 85 37 50 37 50 25 37 25 37 18 25 18 25 6 8 6 8 37 50 37 50 37 50 37 50 100% 100% 100% 100% 105 187 105 187 77.7 105 77.7 105 52.5 77.7 52.5 77.7 36 52.5 36 52.5 9.2 13.6 9.2 13.6 A A ● ● ● ● ● ● - -- -- -- -- -- -- -- -- -● ● ● ● - -- -25000 25000 10000 10000 76x130x82 76x130x82 101x130x82 101x130x82 1.05 1.05 1.35 1.35 IEC60947-2 IEC60947-2

(11)

Trip units

Thermal magnetic trip units

Overview

Characteristics

FTU

�Fixed thermal

16A ... 160A rated currents

�Fixed magnetic

400A ... 1600A tripping currents

Fixed thermal, fixed magnetic trip units

Im=1600A

160A

TE160 FTU

Ir Im

FMU

�Adjustable thermal 16A ... 160A rated currents Adjustable : 0.8~1×In

�Fixed magnetic

400A ... 1600A tripping currents

Adjustable thermal, fixed magnetic trip units

160A

Im=1600A

TE160 FMU

Setting details

TE160 In Thermal setting Ir[A] Magnetic setting Im[A] Neutral protection

[A] 4P4T 4P3T 16 16 400 =Ir =Im 20 20 400 =Ir =Im 25 25 400 ±20% =Ir =Im 32 32 400 =Ir =Im 40 40 400 =Ir =Im

FTU 50 Ir = In 50 500 =Ir =Im

63 63 630 =Ir =Im

80 80 800

10xIn ±20% =Ir =Im 100 100 1000 =Ir =Im 125 125 1250 =Ir =Im 160 160 1600 =Ir =Im 16 12.8 16 400 =Ir =Im 20 16 20 400 =Ir =Im 25 20 25 400 ±20% =Ir =Im 32 25.6 32 400 =Ir =Im 40 32 40 400 =Ir =Im FMU 50 Ir = 0.8-1In 40 50 500 =Ir =Im 63 50.4 63 630 =Ir =Im 80 64 80 800

10xIn ±20% =Ir =Im 100 80 100 1000 =Ir =Im 125 100 125 1250 =Ir =Im 160 128 160 1600 =Ir =Im no protection no protection

(12)

Accessories

12

Auxiliary switch (AX)

Auxiliary switch is for applications requiring remote “ON”and “OFF”indication. Each switch contains two contacts having a common connection.

One is open and the other closed when the circuit breaker is open, and viceversa.

Alarm switch (AL)

Alarm switches offer provisions for immediate audio or visual indication of a tripped breaker due to overload, short circuit, shunt trip, or undervoltage release conditions.

They are particularly useful in automated plants where operators must be signaled about changes in the electrical distribution system. This switch features a closed contact when the circuit breaker is tripped automatically. In other words, this switch does not function when the breaker is operated manually.

Its contact is open when the circuit breaker is reset.

Combination switch (AX+AL)

It consists of one auxiliary switch (AX) and one alarm switch (AL) in a body to connect into the same position of

the breaker.

Contact

Rating

Auxiliary and Alarm switch

MCCB

AX

AL

ON OFF TRIP

Conventional thermal current, Ith Rated operational current, Ie

AC 50/60Hz DC 5A Voltage, Ue 125V 250V 500V 30V 125V 250V Current, Ie

Resistive load Inductive load

5 3 3 2 - -4 3 0.4 0.4 0.2 0.2

(13)

Accessories

Shunt trip, SHT

The shunt trip opens the mechanism in response to an externally applied voltage signal. The releases include coil clearing contacts that automatically clear the signal circuit when the mechanism has tripped.

The shunt release can be installed in the right accessory compartment of the MCCBs.

- Range of operational voltage AC : 0.7~1.1Vn, DC : 0.8~1.1Vn - Frequency(Only AC) : 45Hz ~ 65 Hz

Rating

Voltage

Max.opening time

Tightening torque of terminal screw AC/DC 12V AC/DC 24V AC/DC 48V AC/DC 60V AC/DC 100~130V AC/DC 200~250V AC 380~450V AC 440~500V AC (VA) 0.35 0.64 1.09 1.2 0.73 1.21 1.67 1.68 Power consumption DC (W) 0.36 0.65 1.1 1.22 0.75 1.35 -50ms (max.) 8.2 kgf∙cm mA 30 27 23 20 5.8 5.4 3.8 3.5 Control voltage, Ue

(14)

Accessories

14

The undervoltage release automatically opens a circuit breaker when voltage drops to a value ranging between 20% to 70% of the line voltage. The operation is instantaneous, and after tripping, the circuit breaker cannot be re-closed again until the voltage returns to 85% of line voltage.

Continuously energized, the undervoltage release must be operating before the circuit breaker can be closed. The undervoltage release can be easily installed in the right accessory compartment of the MCCBs.

- Range of tripping voltage: 0.2 ~ 0.7Vn

- MCCB making is possible voltage: 0.85Vn (Exceed) - Frequency (Only AC): 45Hz ~ 65Hz

Rating

Maximum possibilities

Undervoltage release, UVT

Voltage

Max.opening time

Tightening torque of terminal screw Operating voltage range AC/DC 24V AC/DC 48V AC/DC 100~110V AC/DC 200~220V AC 380~440V AC 440~480V Trip Reset/Closing AC (VA) 0.64 1.09 0.73 1.21 1.67 1.68 Power consumption DC (W) 0.65 1.1 0.75 1.35 -50ms (max.) 8.2 kgf∙cm 20~70% Vn ≥0.85Vn mA 27 23 5.8 5.4 3.8 3.5 Control voltage, Ue Left-hand seat AX 1 AL 1 AX 1 Right-hand seat AL 1 SHT/UVT 1 TE160 3/4P Position Type

(15)

Accessories

Rotary handles

The rotary handle operating mechanism is available in either the direct version or in the extended version on the compartment door.

It is always fitted with a compartment door lock and on a request it can be supplied with a key lock in the open position.

Direct rotary handles

MCCB Rotary handle TE160 DH1E

Extended rotary handles

MCCB Rotary handle TE160 EH1E

Degree of protections

Type Degree of protection IP DH1E The acess probe of 1.0mm diameter IP40

shall not penetrate

EH1E Totally protected against ingress of IP55 dust and water jets from any direction

(16)

Accessories

16

Terminals

Front connection

Extended terminal

- As an optional part of circuit breaker - Can increase the pitch of the terminals

Flat terminals

MCCB Pole Type Feature

TE100 3P ET13E

TE160 4P ET14E

Rear connection

Rear connection terminals are used to adapt Susol TE circuit breakers to switchboards or other application that require rear connection.

These can be connected directly to circuit breakers without any modification.

MCCB Pole Type Feature

TE100 3P RTF13

(17)

Accessories

Insulation

Insulation by barrier

These allow the insulation characteristics between the phases at the connections to be increased.

They are mounted from the front, even with the circuit-breaker already installed, inserting them into the corresponding slots.

They are incompatible with both the insulating terminal covers.

It is possible to mount the phase separating partitions between two circuit-breakers side by side.

Insulation by terminal cover

Insulation terminal cover

The terminal covers are applied to the circuit-breaker to prevent accidental contact with live parts and thereby guarantee protection against direct contacts.

Two types by length are available:

Short type covers, ITS

�IP40 degree of protection

�For fixed circuit-breakers with rear terminals and for moving parts of plug-in Long type covers, ITL

�IP40 degree of protection

�For fixed circuit-breakers with front, front extended, front for cables terminals.

Type Applied MCCB Set quantity 3P 4P B13C TE100, TE160

2pcs 4pcs

Type Terminal cover

Frame type pole Long type Short type TE100, TE160

3P ITL13E ITS13E 4P ITL14E ITS14E Short type covers

(18)

Accessories

18

Mechanical interlocking device

The mechanical interlock (MIT) can be applied on the front of two breakers mounted side by side, in either the 3-pole or 4-pole version and prevents simultaneous closing of the two breakers.

Fixing is carried out directly on the cover of the breakers.

The front interlocking plate allows installation of a padlock in order to fix the position. (possibility of locking in the O-O position as well)

This mechanical interlocking device is very useful and simple for consisting of manual source-changeover system.

Interlock

Note) Terminal covers do not use with the interlock.

Mechanical Interlock (Padlocks are not supplied)

Left MCCB: ON/OFF is possible Right MCCB: Off lock

Operation

Left MCCB: Off lock

Right MCCB: ON/OFF is possible

Interlock handle

Interlock bar

Both MCCBs are of locked

MCCB

Frame type pole Interlock TE100, TE160

3P MIT13E 4P MIT14E

(19)

Technical information

Power dissipation / Resistance

Susol TE series MCCB with thermal-magnetic trip units

AF TE100 TE160

Rationg (A) 16 20 25 32 40 50 63 80 100 125 160 R (MΪ ) 8.5 8.5 6.4 2.6 2.5 1.8 1.4 1.2 0.8 0.6 0.5 Fixed MCCB Watt single pole 2.2 3.4 4.0 2.7 4.0 4.5 5.6 7.7 8.0 9.4 12.8 Watt three pole 6.5 10.2 12.0 8.0 12.0 13.5 16.7 23.0 24.0 28.1 38.4

(20)

Characteristics curves

20

Thermal-Magnetic trip units

TE100

FTU

FMU

16~100A

(21)

Characteristics curves

Circuit breakers with thermal-magnetic trip units

TE160

FTU

FMU

100~160A

(22)

Overall dimensions

22

TE100/TE160

110 25 M4 OR ∅5 110 47 83 47 83 25 78 103 CL CL CL CL CL CL CL CL

Panel drilling

Front panel cutting

[mm] 21.5 70 82 89.5 L L W T 130 110 81 45 25 25 50 25 101 50 76 CL CL

Wire size Min 2.5mm

2 Max. 70mm2 L(mm) 17.5 W(mm) ≤13.5 T(mm) ≤6 Torque ≤8Nm

(23)

Overall dimensions

Direct rotary handle

DH1E for TE100/TE160

114.9 11 0 101.5 77.5 68.2 t 1.2~3.2 121 92.1

OFF

4-∅5

(24)

Overall dimensions

24

Extended rotary handle

EH1E for TE100/TE160

min 165 t 1.2~3.2 max 589(shaft 459mm) 47 47

OFF

2-∅6 ∅53

(25)

Overall dimensions

Mechanical interlocking device

MIT13E, MIT14E

82 47 83 70 E C D E C ∅4~∅6 30mm

(26)

Overall dimensions

26

Terminal cover

ITS13E, ITS14E

ITL13E, ITL14E

69.5 150 24.5 76 101 76 69.5 64.5 230 101

(27)

Overall dimensions

Rear connection

RTF13, RTF14

135 18 8 70 130 8N�m (82kgf�cm) 8N�m (82kgf�cm) 150 13.8 25 8 42.5 92.5 25 25 ∅7

(28)

Overall dimensions

28

Extended terminal

ET13E, ET14E

190 170 25 76 130 81 5 21.5 70 82 45 50 16 50 5Max 16Ma x 8N�m (82kgf�cm) 8N�m (82kgf�cm)

(29)
(30)

Memo

(31)
(32)

HEAD OFFICE

LS Tower 1026-6, Hogye-dong, Dongan-gu,

Anyang-si, Gyeonggi-do 431-848, Korea

Tel. (82-2)2034-4887, 4873, 4918, 4148

Fax. (82-2)2034-4648 http://www.lsis.biz

Cheong-Ju Plant

Cheong-Ju Plant #1, Song Jung Dong, Hung Duk Ku,

Cheong Ju, 361-720, Korea

Tel. (82-43)261-6001 Fax. (82-43)261-6410

Specifications in this catalog are subject to change without notice due to continuous products development and improvement.

20090901 / STAFF

ⓒ2009.9 LS Industrial Systems Co.,Ltd. All rights reserved.

References

Related documents

Amended Rule 2019(b)(1) broadens its scope by requiring disclosure from any entity, group or committee that consists of or represents multiple creditors or equity security

One-to-One € 30 Two-to-One € 18 Specialised One-to-One € 35 Business English One-to-One € 35 Home Tuition One-to-One € 30 Home Tuition Two-to-One € 18 Daily surcharge

Prospective study of the clinical features and outcomes of emergency department patients with delayed diagnosis of pulmonary embolism. Hull RD, Raskob GE, Brant RF, Pineo GF,

Forward-looking information is based on the reasonable assumptions, estimates, analysis and opinions of management made in light of its experience and its perception of trends,

In this retrospective study of Medicaid beneficiaries, the cost and HRU burden of TRD was assessed and compared with two matched cohorts: one comprising patients with MDD who were

• 80 PPM / 160 IPM Duplex Scanner • 100 Sheet ADF Capacity • Scan to searchable PDF • Support multiple image output • Auto-scan when detect documents •

high visual comfort, the spacing (d) between two Quintessence downlights may be up to approxi- mately 1.5 times the height (h) of the luminaire above the working plane. Arrangement: d

The formulation presented so far defines the quantum reaction rate but cannot be applied to complex systems due to the di fficulty of obtaining the exact multidimensional