• No results found

Active knee extension test.

Comparison of active knee extension test and straight leg raise angle in visual display terminal operators with or without low back pain

Comparison of active knee extension test and straight leg raise angle in visual display terminal operators with or without low back pain

... greater knee extension and less pelvic motion than ...of active knee extension angle with the low back ...that active knee extension test should provide both ...

6

Universal goniometer and electro-goniometer intra-examiner reliability in measuring the knee range of motion during active knee extension test in patients with chronic low back pain with short hamstring muscle

Universal goniometer and electro-goniometer intra-examiner reliability in measuring the knee range of motion during active knee extension test in patients with chronic low back pain with short hamstring muscle

... measuring knee extension during AKE test in a single ...uring knee angle may be useful in choosing a proper method in clinical practice and/or research ...

5

The Effect of Stretching and Propiroceptive Neuromuscular Facilitation in Spastic Diplegic Cerebral Palsy: A Comparative study

The Effect of Stretching and Propiroceptive Neuromuscular Facilitation in Spastic Diplegic Cerebral Palsy: A Comparative study

... 3) Shamik Bhattacharjee, Masih Muhammad Khan, PritamDeka, AbhijitDutta (2016) a study conducted the efficacy of modified proprioceptive neuromuscular facilitation stretching with cryotherapy overall passive stretching ...

59

The Effect of Active Knee Extension in Sitting on Lumbopelvic Curvature in Individuals with Clinically Tight Hamstring Muscles: A Cross Sectional Reliability Study

The Effect of Active Knee Extension in Sitting on Lumbopelvic Curvature in Individuals with Clinically Tight Hamstring Muscles: A Cross Sectional Reliability Study

... The Active Knee Extension test is considered as the gold standard assessment of the hamstring tightness ...the knee flexion/extension angle can be altered by minimum lumbopelvic ...

9

Measurement Reliability for Evaluating Lumbopelvic Curvature during Active Knee Extension in Sitting Using a Flexible Ruler in Individuals with Clinically Tight Hamstring Muscles: A Secondary Analysis

Measurement Reliability for Evaluating Lumbopelvic Curvature during Active Knee Extension in Sitting Using a Flexible Ruler in Individuals with Clinically Tight Hamstring Muscles: A Secondary Analysis

... The minimum number of repetitions was investigated with data collected by one examiner at the first session using the Max-Method and the Mid-Method. De- tailed procedures of analysis were described previously [5]. ...

7

The loss of extension test (LOE test): a new clinical sign for the anterior cruciate ligament insufficient knee

The loss of extension test (LOE test): a new clinical sign for the anterior cruciate ligament insufficient knee

... Lachman test’’ and the ‘‘no-touch Lachman test,’’ respectively, in which the examiner observes the anterior subluxation of the tibia on the femur during an active contraction of the quadriceps at ...

7

Immediate effect of supervised self myofascial release over the plantarfascia on lumbar and hamstring flexibility

Immediate effect of supervised self myofascial release over the plantarfascia on lumbar and hamstring flexibility

... Modified Active knee extension to measure Hamstring length using 29 subjects, while AKE test was performed in 5 different positions (Chris and Skarabot, ...

5

Measurement properties of the upright motor control test for adults with stroke: a systematic review

Measurement properties of the upright motor control test for adults with stroke: a systematic review

... the Knee Extension subtest may change over time, possible floor and ceiling effects can be observed ...an active treatment compared to those exposed to ...the test of interest (i.e. UMCT) ...

11

The effect of continuous passive motion and sling exercise training on clinical and functional outcomes following total knee arthroplasty: a randomized active-controlled clinical study

The effect of continuous passive motion and sling exercise training on clinical and functional outcomes following total knee arthroplasty: a randomized active-controlled clinical study

... randomized active-controlled clinical study was conducted to compare the effectiveness of two in-hospital range of motion (ROM) exercise programs following total knee arthroplasty ...new active ...

10

Inter-rater agreement, sensitivity, and specificity of the prone hip extension test and active straight leg raise test

Inter-rater agreement, sensitivity, and specificity of the prone hip extension test and active straight leg raise test

... PHE test or ASLR test in clinical prac- tice prior to their involvement in the current ...a test involving the ...PHE test and ASLR test ...first test was classified as ...

8

A Proprioceptive Discussion on Mechanism Used for Knee Joint from 2000-2012: A Literature Review

A Proprioceptive Discussion on Mechanism Used for Knee Joint from 2000-2012: A Literature Review

... oss of limb has been a problem as long important part of an above knee prosthesis is the mechanism employed for satisfactory flexion and extension functions of the knee joint. as man has been in ...

7

Thesis

Thesis

... of knee flexion, as some individuals with knee OA may be unable to achieve 90° of knee ...bilateral knee OA, participants were asked which knee was more symptomatic, and the knee ...

43

The effects of localized fatigue in the knee extensors on crank power and muscle activation

The effects of localized fatigue in the knee extensors on crank power and muscle activation

... left knee extensors resulted in a reduction in left crank power over the downstroke, the system could potentially try to limit the overall reduction in performance by increasing upstroke power in the non-fatigued ...

106

Browne_unc_0153M_16141.pdf

Browne_unc_0153M_16141.pdf

... external knee adduction moment in patients suffering from knee osteoarthritis have implemented simple shoe wedges under the lateral portion of the heel (Chapman et ...

34

Age-related change in sit-to-stand power in Japanese women aged 50 years or older

Age-related change in sit-to-stand power in Japanese women aged 50 years or older

... STS test, can be a con- venient measure for assessing the age-related decline in knee extension torque, but it declines more rapidly than leg lean tissue ...of knee extensor ...of knee ...

5

A Digital Photographic Technique for Knee Range of Motion Measurement: Performance in a Total Knee Arthroplasty Clinical Population

A Digital Photographic Technique for Knee Range of Motion Measurement: Performance in a Total Knee Arthroplasty Clinical Population

... Background: Knee range of motion is an essential outcome measure following total knee arthroplasty and it is im- portant to measure this outcome with a simple and accurate ...involving knee range of ...

6

New generation of wearable goniometers for motion capture systems

New generation of wearable goniometers for motion capture systems

... Given this finding, the following approach was con- ceived in order to improve the overall accuracy in terms of biomechanical reconstruction with wearable goniome- ters. As a practical example we will now consider the ...

17

A literature review of clinical tests for lumbar instability in low back pain: validity and applicability in clinical practice

A literature review of clinical tests for lumbar instability in low back pain: validity and applicability in clinical practice

... Instability Test (PIT), Passive Lumbar Extension Test (PLE), Aberrant Movements Pattern (AMP), Posterior Shear Test (PST), Active Straight Leg Raise Test (ASLR) and Prone and ...

12

Effects of resistance training on measures of muscular strength in people with Parkinson’s Disease: a systematic review and meta-analysis

Effects of resistance training on measures of muscular strength in people with Parkinson’s Disease: a systematic review and meta-analysis

... PD is a chronic and progressive disorder that is thought to be caused by death of dopami- nergic neurons in the substantia nigra of the basal ganglia [7]. There is emerging evidence that other non-dopaminergic structures ...

23

How to Minimize Rotational Conflict between Femoral & Tibial Component in Total Knee Arthroplasty: The Use of Femoro Tibial Axial Synchronizer (Linker)

How to Minimize Rotational Conflict between Femoral & Tibial Component in Total Knee Arthroplasty: The Use of Femoro Tibial Axial Synchronizer (Linker)

... and knee extension was ...and knee center, and is aimed at achieving femoro-tibial synchronization by us- ing the inter-connected instrument of distal femoral resector and proximal tibial resector ...

6

Show all 10000 documents...

Related subjects