• No results found

Bioelectrical Impedance Analysis (BIA)

Limits of body composition assessment by bioelectrical impedance analysis (BIA)

Limits of body composition assessment by bioelectrical impedance analysis (BIA)

... by bioelectrical impedance analysis allows measurement of, among others, fat mass, fat-free mass, body cell mass, total body water and phase ...

10

Comparison of bioelectrical impedance analysis and magnetic resonance imaging for the quantification of fat mass

Comparison of bioelectrical impedance analysis and magnetic resonance imaging for the quantification of fat mass

... Bioelectrical impedance analysis (BIA) is a cost effective, quick and safe method of assessing body composition. It has high repeatability [11] and unlike BMI and waist hip ratio, can provide ...

5

A practical guide to bioelectrical impedance analysis using the example of chronic obstructive pulmonary disease

A practical guide to bioelectrical impedance analysis using the example of chronic obstructive pulmonary disease

... Summary Bioelectrical impedance analysis (BIA), particularly in combination with bioelectrical impedance vector analy- sis (BIVA), provides a viable opportunity for evaluating body ...

8

Bioelectrical impedance analysis measures of body composition and condition, and its sensitivity to the freezing process

Bioelectrical impedance analysis measures of body composition and condition, and its sensitivity to the freezing process

... Keywords: Impedance, frozen fish quality, Tuna, BIA sensitivity to freezing Introduction Seafood products are an important international ...products. Bioelectrical impedance analysis (BIA) has ...

29

Bioelectrical impedance analysis in clinical practice: implications for hepatitis C therapy BIA and hepatitis C

Bioelectrical impedance analysis in clinical practice: implications for hepatitis C therapy BIA and hepatitis C

... that bioelectrical impedance analysis does have the sensitivity required to distinguish significant differences in patients with chronic HCV infection with respect to body weight, BF, BCM, and TBW, ...

8

Validity and Reliability of Bioelectrical Impedance Analysis and Skinfold Thickness in Predicting Body Fat in Military Personnel

Validity and Reliability of Bioelectrical Impedance Analysis and Skinfold Thickness in Predicting Body Fat in Military Personnel

... frequency bioelectrical impedance analysis (SF-BIA), and multifrequency bioelectrical impedance analysis measurements in 65 male and female ...

11

The novel application of artificial neural network on bioelectrical impedance analysis to assess the body composition in elderly

The novel application of artificial neural network on bioelectrical impedance analysis to assess the body composition in elderly

... Conclusion: When compared the performance of developed prediction equations for estimating reference FFM DXA , the linear model has lower r 2 with a larger SD in predictive results than that of BP-ANN model, which ...

8

Validation of Hand-Held Bioelectrical Impedance Analysis for the Assessment of Body Fat in Young and Old Adults

Validation of Hand-Held Bioelectrical Impedance Analysis for the Assessment of Body Fat in Young and Old Adults

... Visit 1: On the day of your first visit, you will report to the Physical Activity & Health Research Laboratory. A pregnancy test will be conducted for all female participants prior to any assessments. If you are ...

160

Non invasive diagnosis of risk in dengue patients using bioelectrical impedance analysis and artificial neural network

Non invasive diagnosis of risk in dengue patients using bioelectrical impedance analysis and artificial neural network

... the patient cannot be arbitrarily or based on uncertain identification due to the huge number of the dengue patients in the country [20]. Recently, several studies were conducted to achieve accurate diagnosis without ...

6

Monitoring of muscle mass in critically ill patients: comparison of ultrasound and two bioelectrical impedance analysis devices

Monitoring of muscle mass in critically ill patients: comparison of ultrasound and two bioelectrical impedance analysis devices

... Although monitoring of muscle mass is important, identification of an optimal method of estimating muscle mass remains difficult. There are many methods that can estimate muscle mass. In recent years, the use of ...

8

Perioperative fluid dynamics evaluated by bioelectrical impedance analysis predict infectious surgical complications after esophagectomy

Perioperative fluid dynamics evaluated by bioelectrical impedance analysis predict infectious surgical complications after esophagectomy

... postoperative infectious complications which adversely affect postoperative management including fluid dynamics. The aim of the study is to evaluate the utility of perioperative bioelectrical impedance ...

12

Bioelectrical Impedance Analysis (BIA) of the association of the Japanese Kampo concept “Suidoku” (fluid disturbance) and the body composition of women

Bioelectrical Impedance Analysis (BIA) of the association of the Japanese Kampo concept “Suidoku” (fluid disturbance) and the body composition of women

... published. Bioelectrical impedance analysis (BIA) uses resistance values obtained from weak electrical currents to estimate body composition, including intracellular and extracellular water and ...

9

Association of plasma adiponectin levels with cellular hydration state measured using bioelectrical impedance analysis in patients with COPD

Association of plasma adiponectin levels with cellular hydration state measured using bioelectrical impedance analysis in patients with COPD

... adiponectin, bioelectrical impedance analysis (BIA), cellular hydration, COPD, extra pulmonary phenotype Introduction Chronic obstructive pulmonary disease (COPD) is characterized by airflow ...

7

Evaluation of total body water in canine breeds by single frequency bioelectrical impedance analysis method: specific equations are needed for accuracy

Evaluation of total body water in canine breeds by single frequency bioelectrical impedance analysis method: specific equations are needed for accuracy

... Bioelectrical impedance analysis (BIA) is often pre- sented as an alternative to dilution techniques and to dual X-ray absorptiometry for the evaluation of TBW and body ...

5

Simple estimation of excess fluid volume in hemodialysis patients based on multifrequency bioelectrical impedance analysis data

Simple estimation of excess fluid volume in hemodialysis patients based on multifrequency bioelectrical impedance analysis data

... Conflict of interest The authors declare that they have no conflict of interest related to this study. References 1. Kyle UG, Bosaeus I, De Lorenzo AD, Deurenberg P, Elia M, Gómez JM, Heitmann BL, Kent-Smith L, Melchior ...
Inter-sport variability of muscle volume distribution identified by segmental bioelectrical impedance analysis in four ball sports

Inter-sport variability of muscle volume distribution identified by segmental bioelectrical impedance analysis in four ball sports

... Abstract: The aim of this study was to evaluate and quantify differences in muscle distribu- tion in athletes of various ball sports using segmental bioelectrical impedance analysis (SBIA). ...

12

Original Article. Assessment of hydration status and body composition of athlete and non-athlete subjects using Bioelectrical Impedance Analysis

Original Article. Assessment of hydration status and body composition of athlete and non-athlete subjects using Bioelectrical Impedance Analysis

... by bioelectrical impedance analysis and air-displacement plethysmography in both hydration ...to bioelectrical impedance ...mass analysis using bioelectrical ...

6

The variations of body mass index and body fat in adult Thai people across the age spectrum measured by bioelectrical impedance analysis

The variations of body mass index and body fat in adult Thai people across the age spectrum measured by bioelectrical impedance analysis

... The standard ways of measuring FM and FFM need special investigation. Five commonly used methods for body fat detection as standard references are: body density via underwater weighing, DXA, three- and four- compartment ...

10

Bioelectrical impedance analysis device: measurement of bioelectrical tissue conductivity in dengue patients

Bioelectrical impedance analysis device: measurement of bioelectrical tissue conductivity in dengue patients

... that bioelectrical tissue conductivity (BETC), as reflected by reactance is the key determinant indicator for monitoring the hemoglobin status in the DHF ...

18

Evaluation of body composition in COPD patients using multifrequency bioelectrical impedance analysis

Evaluation of body composition in COPD patients using multifrequency bioelectrical impedance analysis

... In particular, no data on low- to high-frequency impedance ratio are available. The general aim of this study was to evaluate whether MF-BIA is a useful tool for the assessment of nutritional status in COPD ...

8

Show all 10000 documents...

Related subjects