• No results found

cephalic vein

Vasoconstrictive responses of the cephalic vein during first-time cardiac implantable electronic device placement

Vasoconstrictive responses of the cephalic vein during first-time cardiac implantable electronic device placement

... axillary vein (AV)/subclavian vein (SV) puncture for lead ...Conclusions: Cephalic vein vasoconstriction is a rare phenomenon associated with accessing the venous system during first-time CIED ...

7

The clinical anatomy of the cephalic vein in the deltopectoral triangle

The clinical anatomy of the cephalic vein in the deltopectoral triangle

... The cephalic vein, defined as the vein originat- ing in the radial end of the dorsal venous arch, winds around the radial border of the forearm and passes proximally along the arm to the shoulder ...

6

A rare case of intravascular epithelioid hemangioendothelioma of the cephalic vein treated with surgery and postoperative radiation therapy: a case report and review of the literature

A rare case of intravascular epithelioid hemangioendothelioma of the cephalic vein treated with surgery and postoperative radiation therapy: a case report and review of the literature

... the cephalic vein, and a subsequent magnetic reson- ance image (MRI) of the arm confirmed a 2×1cm mass with a hypointense T1 signal and a weakly hyperintense T2 signal along the vein, suggesting a ...

10

Closed cannulation of subclavian vein vs open cut-down of cephalic vein for totally implantable venous access port (TIVAP) implantation: protocol for a systematic review and proportional meta-analysis of perioperative and postoperative complications

Closed cannulation of subclavian vein vs open cut-down of cephalic vein for totally implantable venous access port (TIVAP) implantation: protocol for a systematic review and proportional meta-analysis of perioperative and postoperative complications

... the cephalic vein through an open cut-down technique (OCD) (Figure 1) predominantly performed by surgeons with a median pri- mary success rate of 80% (range 71% to 94%) in various prospective and ...

6

Clinical implications of cephalic vein morphometry in routine cardiac implantable electronic device insertion

Clinical implications of cephalic vein morphometry in routine cardiac implantable electronic device insertion

... the cephalic vein (CV) (short arrow) and their drainage site into the external jugular vein; ...axillary vein (AV) with normal, contrast filled lumen is also visible (long arrow); ...6. ...

7

Selected clinical challenges of a supraclavicular cephalic vein in cardiac implantable electronic device implantation

Selected clinical challenges of a supraclavicular cephalic vein in cardiac implantable electronic device implantation

... axillary vein an subclavian vein; no contrast enhancement of the cephalic vein (CV); ...jugulocephalic vein years earlier; C, ...jugular vein cut-down — due to CV ...

6

Variations of the cephalic vein anterior to the clavicle in humans

Variations of the cephalic vein anterior to the clavicle in humans

... jugular vein beyond the edge of the clavicle ...axillary vein and the other joined the external jugular vein beyond the clavicle ...the cephalic vein extended beyond the ...

6

Axillary vein spasm during cardiac implantable electronic device implantation

Axillary vein spasm during cardiac implantable electronic device implantation

... axillary vein (AV) puncture attempts were an indication for venography, which visualised the lack AV contrast enhance- ment with preserved contrast flow via the cephalic vein (white arrow); ...via ...

7

Totally implantable venous access devices: retrospective analysis of different insertion techniques and predictors of complications in 796 devices implanted in a single institution

Totally implantable venous access devices: retrospective analysis of different insertion techniques and predictors of complications in 796 devices implanted in a single institution

... In our series, the overall complication rate is consist- ent with data reported by several studies [4,16-18], that range between 2 to 14.4%. Furthermore, similarly to recent series, we observed a decreasing trend for ...

9

UNDERSTANDING OF URDHWA SHAKHAGAT “AVEDHYA” SIRA .......

UNDERSTANDING OF URDHWA SHAKHAGAT “AVEDHYA” SIRA .......

... axillary vein (larger veins) and terminal part of cephalic vein (terminal part of some specific veins having many tributaries) has to be considerd as Avedhya Sira namely Bahavi, Lohitaksha and ...

7

An Unusual Branching Pattern of the Median Cubital Vein and its Relations with Lateral Cutaneous Nerve of Forearm in the Upper Extremity: Anatomicoclinical Notes

An Unusual Branching Pattern of the Median Cubital Vein and its Relations with Lateral Cutaneous Nerve of Forearm in the Upper Extremity: Anatomicoclinical Notes

... cubital vein (MCV), a 10 cms long venous channel commenced from the cephalic vein 13 cms distal to the lateral epicondyle and passed superomedially superficial to medial branch of lateral cutaneous ...

5

A rare variant of the ulnar artery with important clinical implications: a case report

A rare variant of the ulnar artery with important clinical implications: a case report

... RA radial artery; SuBUA superficial brachioulnar artery; BA brachial artery; CIA common interosseous artery; CV cephalic vein; InCV Intermediate cephalic vein; RAvc radial artery venae c[r] ...

5

Comparison between ultrasound-guided TIVAD via the right innominate vein and the right internal jugular vein approach

Comparison between ultrasound-guided TIVAD via the right innominate vein and the right internal jugular vein approach

... Cephalic vein cut-down technique has been used for more than 30 years ...of cephalic vein approach using surgical techniques for TIVAD is lower, and it is considered su- perior to the SCV ...

7

UPPER ARM BASILIC VEIN TRANSPOSITION FOR HEMODIALYSIS: WHAT IS THE OPTIMAL TECHNIQUE?

UPPER ARM BASILIC VEIN TRANSPOSITION FOR HEMODIALYSIS: WHAT IS THE OPTIMAL TECHNIQUE?

... suitable cephalic vein to construct a radio-cephalic or brachio- cephalic fistula, the basilic vein was unsuitable for use because it measured less than ...basilic vein was ...

7

Original Article Radiological score for hemorrhage in the patients with portal hypertension

Original Article Radiological score for hemorrhage in the patients with portal hypertension

... portal vein thrombosis, or portal hypertension with other causes, such as autoimmune hepatitis, pancreatitis, or hemato- logical diseases were ...portal vein, supe- rior mesenteric vein, inferior ...

7

Case Report Why are there so few cases of anterior tibial vein thrombosis? A case report after total joint arthroplasty and literature review

Case Report Why are there so few cases of anterior tibial vein thrombosis? A case report after total joint arthroplasty and literature review

... tibial vein thrombosis after joint sur- gery, it is imperative to elucidate the hemody- namic mechanisms underlying anterior tibial vein thrombosis to provide new ideas for clini- cal prophylaxis of ...

5

First Anthomyzidae (Diptera) from China: a new genus, six new species and new records

First Anthomyzidae (Diptera) from China: a new genus, six new species and new records

... 2006). They share the robust (and very broad) hypandrium and transandrium, densely spinose basal membrane, asymmetrical basal fork of phallapodeme and very robust fi lum of distiphallus terminating in 3 projections. ...

42

Breech birth at home: outcomes of 60 breech and 109 cephalic planned home and birth center births

Breech birth at home: outcomes of 60 breech and 109 cephalic planned home and birth center births

... Research on outcomes of planned breech home or birth center birth is sparse; the two main datasets that include a subset of home breech births are the MANA Statistics Project and the National Vital Statistics Sys- tem ...

12

In the Eye of the Beholder: Owner Preferences for Variations in Cats’ Appearances with Specific Focus on Skull Morphology

In the Eye of the Beholder: Owner Preferences for Variations in Cats’ Appearances with Specific Focus on Skull Morphology

... Cephalic rating provided for 15 cat images by veterinarian members of the International Society for Feline Medicine list serve ( n = 45–50).. Cephalic rating provided for 15 cat images b[r] ...

16

Outcome of 80 Cases of External Cephalic Version

Outcome of 80 Cases of External Cephalic Version

... Outcome of 80 Cases of External Cephalic Version utcome of 80 Cases of External Cephalic ® Version T G K Teoh, MRCOG, Department of Obstetrics and Gynaecology, University Hospital, 59100 Kuala Lumpur[.] ...

6

Show all 2413 documents...

Related subjects