• No results found

distal tibial fractures

Minimally invasive percutaneous plate osteosynthesis versus intramedullary nail fixation for distal tibial fractures: a systematic review and meta-analysis

Minimally invasive percutaneous plate osteosynthesis versus intramedullary nail fixation for distal tibial fractures: a systematic review and meta-analysis

... Recent meta-analyses studies [8] on this topic have drawn the conclusion that the MIPPO fixation tech- nique is associated with a longer time to reunion and increased rate of wound complications. Although our study ...

9

A case study of distal tibial fractures managed with locking compression plate using MIPO technique

A case study of distal tibial fractures managed with locking compression plate using MIPO technique

... This is to certify that this dissertation titled “A CASE STUDY OF DISTAL TIBIAL FRACTURES MANAGED WITH LOCKING COMPRESSION PLATE USING MIPO TECHNIQUE” is a bonafide work done by Dr.P.VANAJ KUMAR., ...

144

Functional analysis of Distal tibial fractures treated by Hybrid external fixator

Functional analysis of Distal tibial fractures treated by Hybrid external fixator

... This is to certify that this dissertation entitled ' Functional Analysis of Distal Tibial Fractures treated by Hybrid External Fixator' is a record of bonafide research work done by Dr. JEYA ...

156

Functional Outcome of various modalities of management of Distal Tibial Fractures

Functional Outcome of various modalities of management of Distal Tibial Fractures

... OF DISTAL TIBIAL FRACTURES” is a bonafide work done by me at Kilpauk Medical College 2004-2007 under the guidance and supervision of my unit’s chief ...

92

Functional outcome of medial distal tibial locking compression plate fixation in distal tibial fractures: A prospective study

Functional outcome of medial distal tibial locking compression plate fixation in distal tibial fractures: A prospective study

... Distal tibial fractures result from a range of low to high energy axial- loading and are commonly associated with comminution of both the metaphysis and the distal ...extremity ...

97

Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study

Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study

... of distal tibial fracture, especially compared with conventional external ...closed distal tibial fractures and shown good rates of union and ankle-joint motion [8–11] due to the use of ...

6

Comparison of intramedullary nailing and plate fixation in distal tibial fractures with metaphyseal damage: a meta-analysis of randomized controlled trials

Comparison of intramedullary nailing and plate fixation in distal tibial fractures with metaphyseal damage: a meta-analysis of randomized controlled trials

... ankle. Fractures of the distal tibial metaphysis, diaphysis, and adjacent diaphysis are commonly seen in road traffic accidents or sports ...metadiaphyseal fractures are distinct in terms of ...

11

Results of Dynamic Interlock Nailing in Distal Tibial Fractures

Results of Dynamic Interlock Nailing in Distal Tibial Fractures

... at distal tibia prevents intimate contact between the nail and endosteum, insertion of two distal locking screws becomes therefore more ...double distal screw fixation so as to obtain better control ...

10

Treatment of distal tibial fractures with the Ilizarov external fixator   a prospective observational study in 39 consecutive patients

Treatment of distal tibial fractures with the Ilizarov external fixator a prospective observational study in 39 consecutive patients

... comminuted fractures, a foot fixation with trans-calcaneal and trans-metatarsal wire fix- ation without hinges (foot extension), was added to the ...articular fractures, 152 min (range 50–224), compared ...

12

Management of extra-articular distal tibial fractures with combined external fixation and limited internal fixation: A prospective study

Management of extra-articular distal tibial fractures with combined external fixation and limited internal fixation: A prospective study

... C tibial pilon fractures with Hoffmann II external ...reconstructed distal tibial fragment and attached to a half-ring and then connected to two tibial diaphyseal half-pins by two side ...

62

Effectiveness of Biological Fixation of Distal Tibial Fractures with Locking Compression Plates in Adults

Effectiveness of Biological Fixation of Distal Tibial Fractures with Locking Compression Plates in Adults

... Maintaining the length and rotation of the tibia is the main concern in the treatment of high velocity vertical fractures of the tibial plafond and lower tibia. There has been a lot of work throughout the ...

129

Residual angulation of distal tibial diaphyseal fractures in children younger than ten years

Residual angulation of distal tibial diaphyseal fractures in children younger than ten years

... sustained distal tibial fractures between 2001 and 2008 and were treated at one of two tertiary referral centers were ...total tibial length (from the center of the tibial spine to the ...

7

Comparative analytical study outcome of multidirectional locked nailing and plating for distal tibial frctures

Comparative analytical study outcome of multidirectional locked nailing and plating for distal tibial frctures

... fibular fractures were fixed with plate ...open distal tibial fractures with external fixators as a definitive procedure has its own complication like ankle stiffness, pin tract ...

143

Evaluation of Anterolateral Plating of Distal Third Tibial Fractures: A Prospective Study

Evaluation of Anterolateral Plating of Distal Third Tibial Fractures: A Prospective Study

... of distal tibial fractures operated by anterolateral plating were reviewed at 1 year ...the fractures united at an average duration of ...

7

Retrograde Tibial Nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures

Retrograde Tibial Nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures

... (Medial Distal Tibial Plate, Synthes®, West Chester, PA, USA) in an extra-articular distal tibial fracture model (AO/OTA 43 A3) ...Medial Distal Tibial Plate (MDTP) were ...

8

Original Article Treatment of segmental tibial shaft fractures: combination of external fixator with titanium elastic nails versus locking intramedullary nail

Original Article Treatment of segmental tibial shaft fractures: combination of external fixator with titanium elastic nails versus locking intramedullary nail

... of tibial shaft fractures, it is associated with severe complications with clinically rele- vant ...the distal or proximal tibia, which is near the joint surface, IM nailing may not be a suitable ...

10

Comparative evaluation of minimally invasive ‘tibial tuberoplasty’ surgical technique versus conventional open surgery for Schatzker II–III tibial plateau fractures: design of a multicentre, randomised, controlled and blinded trial (TUBERIMPACT study)

Comparative evaluation of minimally invasive ‘tibial tuberoplasty’ surgical technique versus conventional open surgery for Schatzker II–III tibial plateau fractures: design of a multicentre, randomised, controlled and blinded trial (TUBERIMPACT study)

... Introduction Fractures of the tibial plateau are in constant ...for tibial plateau fractures has several pitfalls: bone and skin devascularisation, increased risks of infection and functional ...

9

A Compartive analysis of functional outcome of tibial plateau fractures treated with proximal tibial locking plate with raft screw technique and conventional buttress plating

A Compartive analysis of functional outcome of tibial plateau fractures treated with proximal tibial locking plate with raft screw technique and conventional buttress plating

... OF TIBIAL PLATEAU FRACTURES TREATED WITH PROXIMAL TIBIAL LOCKING PLATE WITH RAFT SCREW TECHNIQUE AND CONVENTIONAL BUTTRESS PLATING ” submitted by me for the degree of ...

134

Inflation osteoplasty: in vitro evaluation of a new technique for reducing depressed intra-articular fractures of the tibial plateau and distal radius

Inflation osteoplasty: in vitro evaluation of a new technique for reducing depressed intra-articular fractures of the tibial plateau and distal radius

... intra-articular fractures of the tibial plateau and distal ...depression fractures now treated nonoperatively could thus undergo a simple, minimally invasive procedure that would restore ...

7

Original Article The clinical diagnosis and risk factors of posterior malleolar fracture in tibial spiral fractures

Original Article The clinical diagnosis and risk factors of posterior malleolar fracture in tibial spiral fractures

... ankle fractures through conventional radiogra- phy and CT to determine the size of the poste- rior fragment, showing that the plain radiograph has very poor inter- and intrareliability ...

8

Show all 5269 documents...

Related subjects