• No results found

distribution system unified conditioner

OPTIMIZATION OF ELECTRICAL POWER QUALITY USING UNIFIED POWER QUALITY CONDITIONER: A REVIEW

OPTIMIZATION OF ELECTRICAL POWER QUALITY USING UNIFIED POWER QUALITY CONDITIONER: A REVIEW

... : Unified Power Quality Conditioner (UPQC) is combination of shunt and series active power filter which are used in distribution system to control the voltage related problem such as voltage ...

5

Single Stage Three-Phase PV System Applied to Microgrid for Power Quality Improvement

Single Stage Three-Phase PV System Applied to Microgrid for Power Quality Improvement

... dual unified power quality conditioner/uninterruptible power supply in three-phase four-wire systems, IET Power ...versatile unified power quality conditioner applied to three-phase four-wire ...

7

Implementation and Modeling of Adaptive Filters in UPQC

Implementation and Modeling of Adaptive Filters in UPQC

... POWER-QUALITY CONDITIONER (UPQC) systems were widely studied by many researchers as an eventual method to improve the PQ in electrical distribution systems ...power system engineers at transmission ...

9

A Dual Compensation Control in Unified Power Quality Conditioner (UPQC) for Power Quality Improvement in Distribution System with Non Linearity

A Dual Compensation Control in Unified Power Quality Conditioner (UPQC) for Power Quality Improvement in Distribution System with Non Linearity

... the system has been studies in three types of nonlinear loadings; three phase unbalanced RL and RC load connected via three single phase rectifier and balanced three phase resistive load connected through three ...

6

UPQC with Islanding and Grid Connection for Microgrid Applications

UPQC with Islanding and Grid Connection for Microgrid Applications

... grid system is mentioned in ...in distribution generation based grid connected microgrid system, to investigate that the mitigation techniques are suitable for voltage sag/ swell and interruptions in ...

8

AN ANN BASED APPROACH FOR OPTIMAL PLACEMENT OF DSTATCOM FOR VOLTAGE SAG MITIGATION

AN ANN BASED APPROACH FOR OPTIMAL PLACEMENT OF DSTATCOM FOR VOLTAGE SAG MITIGATION

... like Distribution Static Compensator (DSTATCOM), Dynamic Voltage Restorer (DVR), Unified Power Quality Conditioner (UPQC), Battery Energy Storage System (BESS), and many more such ...

9

UPQC Based Power Quality Improvement in Distribution System Connected with PV Arrays

UPQC Based Power Quality Improvement in Distribution System Connected with PV Arrays

... In recent years, Unified Power Quality Conditioner which offers customers high quality of power has become an increased concern of engineers. UPQC is a combination of a shunt (APF) and a series compensator ...

7

Investigation on Performance Efficacies of Custom Power Devices for Power Quality Improvement

Investigation on Performance Efficacies of Custom Power Devices for Power Quality Improvement

... power distribution systems, power quality problems with different levels of severity may cause and this causes a huge financial drawback to the application use ...the system as an advanced power ...

8

Enhancing Power Quality of Distributed Power Network with Unified Power Quality Conditioner & FLC

Enhancing Power Quality of Distributed Power Network with Unified Power Quality Conditioner & FLC

... AC-transmission system (FACTS) family, called unified power quality conditioner (UPQC) is presented in this ...the unified power flow controller (UPFC). The unified power quality ...

8

Comparision Of PI Controller & Fuzzy Logic Controller Using Unified Power Quality Conditioner

Comparision Of PI Controller & Fuzzy Logic Controller Using Unified Power Quality Conditioner

... In addition to this, it provides harmonic isolation between a sub-transmission system and a distribution system. The shunt active power filter connected in parallel with load. It acts as a controlled ...

9

Improvement of power quality using unified power quality conditioner

Improvement of power quality using unified power quality conditioner

... electrical system for example Power Factor Improvement Capacitors, Indescent Lamps and ...power distribution system, which is the second type of electrical loads, the load is considered to be ...

40

Dual Control Strategy Based Three-Phase Four-Wire Distribution Systems in Unified Power Quality Conditioner for Power Factor Improvement

Dual Control Strategy Based Three-Phase Four-Wire Distribution Systems in Unified Power Quality Conditioner for Power Factor Improvement

... and/or configurations of single-phase-to-three-phase (1Ph-to-3Ph) converters have been addressed in the literature [6], [7], [9]-[11]. These include 1ph-to-3Ph four-wire converters, which are able of supplying ...

7

A SIMPLIFIED CONTROL TECHNIQUE FOR A DUAL UNIFIED POWER QUALITY CONDITIONER

A SIMPLIFIED CONTROL TECHNIQUE FOR A DUAL UNIFIED POWER QUALITY CONDITIONER

... the distribution system network has increased during the past years due to the steady increase of nonlinear loads connected to the electrical ...a unified power quality conditioner (UPQC), it ...

8

Integration of Artificial Intelligence Control to the Unified Power Quality Conditioner

Integration of Artificial Intelligence Control to the Unified Power Quality Conditioner

... sub-transmission system and a distribution system; it has the capability of voltage flicker/ imbalance compensation as well as voltage regulation and harmonic compensation at the utility-consumer ...

13

Power quality enhancement by Unified power Quality Conditioner Using ANN with Hysteresis Control

Power quality enhancement by Unified power Quality Conditioner Using ANN with Hysteresis Control

... combined system of shunt and active series filters like unified power quality conditioner (UPQC) This device combines a shunt active filter together with a series active filter in a back- to-back ...

7

A NOVEL CONTROL METHOD FOR UNIFIED POWER QUALITY CONDITIONER USING NINE - SWITCH POWER CONDITIONER

A NOVEL CONTROL METHOD FOR UNIFIED POWER QUALITY CONDITIONER USING NINE - SWITCH POWER CONDITIONER

... Abstract: The load-reactive power compensation in most of the UPQC based power quality compensation application is done by shunt APF, whereas, the series APF is generally utilized to compensate voltage related problems. ...

5

A Novel Topology for Dual Unified Power Quality Conditioner

A Novel Topology for Dual Unified Power Quality Conditioner

... applications(Distribution system network) is the non- interference of the leakage impedance voltage of the series active filter (SAF) connection transformer in the load voltage compensation since the load ...

16

Unified Power Quality Conditioner (UPQC) using MATLAB

Unified Power Quality Conditioner (UPQC) using MATLAB

... power system engineer is Reactive Power Compensation in transmission as well as distribution ...a distribution network there is distribution transformer , motor loads ,etc which demands ...

7

Unified Power Quality Conditioner for voltage and current compensation

Unified Power Quality Conditioner for voltage and current compensation

... system. It consists of combined series and shunt converters for simultaneous compensation of voltage and current imperfections in a point of common connection (PCC) in the distribution side [2]. The series ...

6

Design and Simulation of Dual Unified Power Quality Conditioner with Fuzzy Logic Controller for Power Quality Improvement

Design and Simulation of Dual Unified Power Quality Conditioner with Fuzzy Logic Controller for Power Quality Improvement

... and distribution side ...different distribution voltage levels regardless of voltage fluctuations, keeping up close unity power factor power drawn from the supply, obstructing of voltage and current ...

14

Show all 10000 documents...

Related subjects