• No results found

Fabry Perot

High-Gain Low Side Lobe Level Fabry Perot Cavity Antenna with Feed Patch Array

High-Gain Low Side Lobe Level Fabry Perot Cavity Antenna with Feed Patch Array

... Abstract—In this paper, a high gain, low side lobe level Fabry Perot Cavity antenna with feed patch array is proposed. The antenna structure consists of a microstrip antenna array, which is parasitically ...

16

Mode resolved Fabry Perot experiment in low loss Bragg reflection waveguides

Mode resolved Fabry Perot experiment in low loss Bragg reflection waveguides

... The linear optical waveguide characteristics such as refractive index and its dispersion, trans- mission losses or the reflectivity at the end facets are relevant to practical purposes and impor- tant feedback for ...

14

A Dual-Polarized Fabry-Perot Cavity Antenna at Ka Band with Broadband and High Gain

A Dual-Polarized Fabry-Perot Cavity Antenna at Ka Band with Broadband and High Gain

... Abstract—A broadband Fabry-Perot cavity antenna (FPCA) operates at Ka band with high gain and dual-polarization is reported. The proposed antenna employed a double-sided complementary-circular partially ...

8

The synoptic variability of thermospheric and mesospheric winds observed using a Fabry-Perot interferometer

The synoptic variability of thermospheric and mesospheric winds observed using a Fabry-Perot interferometer

... T he light rays impinging on the Fabry-Perot etalon come at angles within the 1° field of view. This allows the small angle approxim ation to be used in calculating the positions of the fringes. A direct ...

283

A Fabry–Perot interferometer-based camera for two-dimensional mapping of SO 2distributions

A Fabry–Perot interferometer-based camera for two-dimensional mapping of SO 2distributions

... A FabryPerot interferometer (FPI) is used to compare the scattered sunlight radiance at wave- lengths corresponding to absorption bands with the radiance at wavelengths in between the bands, thereby ...

11

Dynamics of Neutral Wind in the polar region observed with two Fabry Perot Interferometers

Dynamics of Neutral Wind in the polar region observed with two Fabry Perot Interferometers

... Optical observations using interferometers provide infor- mation useful for estimating the wind velocity and temper- atures in neutral dynamics. In particular, the neutral wind in the vertical direction that heating ...

12

Thermospheric wind variations observed by a Fabry–Perot interferometer at Tromsø, Norway, at substorm onsets

Thermospheric wind variations observed by a Fabry–Perot interferometer at Tromsø, Norway, at substorm onsets

... A FabryPerot interferometer (FPI), which measures the Doppler shift of emission lines from aurora and air- glow, is a unique optical instrument. FPIs can measure the thermospheric wind from the ...

13

Optical gas sensors based on correlation spectroscopy using a Fabry Perot interferometer

Optical gas sensors based on correlation spectroscopy using a Fabry Perot interferometer

... As was stated in previous section the cross correlation spectroscopy as defined by Goody [60] is between the spectra of an unknown mixture , contained in the measurement cell, and the spectra of the target gas , which is ...

227

Cso/Ctb Performance Improvement by Using Fabry-Perot Etalon at the Receiving Site

Cso/Ctb Performance Improvement by Using Fabry-Perot Etalon at the Receiving Site

... concern. Fabry-Perot (FP) etalon, with an optical characteristic of narrow optical band-pass filter, can reshape the laser spectrum and reduce the spectral width ...

7

Wideband Fabry-Perot Resonator Antenna with Single-Layer Partially Reflective Surface

Wideband Fabry-Perot Resonator Antenna with Single-Layer Partially Reflective Surface

... Fabry-Perot resonator antennas (FPRA) have attracted a lot of interest in the communication field due to their merits of high gain, high radiation efficiency, and especially simple feeding networks. In the ...

5

Cavity QED in microsphere and Fabry Perot cavities

Cavity QED in microsphere and Fabry Perot cavities

... and Fabry-Perot res- onators each have their advantages and ...the Fabry-Perot cavities considered here re- quire specialized coating runs with expensive equipment and considerable expertise, ...

221

Comparative Study of Fabry-Perot Resonator Antenna with PMC and PEC Ground Plane

Comparative Study of Fabry-Perot Resonator Antenna with PMC and PEC Ground Plane

... Fabry-Perot Resonator (FPR) antenna generally consists of a primary radiator backed with a metal ground plane and a partially reflective covered plate [1]. It essentially provides the benefit of high ...

19

Measurement of thermospheric temperatures using OMTI Fabry–Perot interferometers with 70 mm etalon

Measurement of thermospheric temperatures using OMTI Fabry–Perot interferometers with 70 mm etalon

... FabryPerot interferometer (FPI) is an instrument that can measure the temperature and wind velocity of the ther- mosphere through observations of airglow emission at a wavelength of 630.0 nm. The ...

13

The transmission curve of a fabry perot system based on plane and spherical mirror separation

The transmission curve of a fabry perot system based on plane and spherical mirror separation

... with Fabry Perot system is it needs a high resolution device for the detection of light intensity that depends on the transmission" curve of the ...a Fabry Perot based on plane and ...

38

A Millimeter-Wave Wideband High-Gain Antenna Based on the Fabry-Perot Resonator Antenna Concept

A Millimeter-Wave Wideband High-Gain Antenna Based on the Fabry-Perot Resonator Antenna Concept

... the Fabry-Perot cavity formed by the superstrate and the ...a Fabry-Perot cavity can vary when the size of the superstrate ...a Fabry-Perot cavity and hence the reflection phase ...

9

Theory, fabrication and applications of a novel archetype Semi-Ring Fabry-Perot (SRFP) resonator, and new tiltmeters

Theory, fabrication and applications of a novel archetype Semi-Ring Fabry-Perot (SRFP) resonator, and new tiltmeters

... generated by the speaker would get back to him. This is a resonant phenomenon. Another example is if someone who is confined in a medium separated by two walls throws a ball to one of the walls. In a specific case, where ...

11

A comparison of thermospheric winds and temperatures from Fabry Perot Interferometer and EISCAT Radar measurements with models

A comparison of thermospheric winds and temperatures from Fabry Perot Interferometer and EISCAT Radar measurements with models

... During the nights of 8-9 and 9-10 February 1997, Fabry-Perot interferometers were operated from the EISCAT radar site at Ramfjord (69.59 o N, 19.23 o E) and Skibotn (69.35 o N, 20.36 o E). From Ramfjord, ...

6

Low-Cost Fiber-Tip Fabry-Perot Interferometer and its Application for Transverse Load Sensing

Low-Cost Fiber-Tip Fabry-Perot Interferometer and its Application for Transverse Load Sensing

... 20. Jauregui-Vazquez, D., J. M. Estudillo-Ayala, A. Castillo-Guzman, R. Rojas-Laguna, R. Swlvas- Aguilar, E. Vargas-Rodrigues, J. M. Sierra-Hernandez, V. Guzman-Ramos, and A. Flores-Balderas, “Highly sensitive curvature ...

6

Design of a Frequency Reconfigurable Fabry-Perot Cavity Antenna with Single Layer Partially Reflecting Surface

Design of a Frequency Reconfigurable Fabry-Perot Cavity Antenna with Single Layer Partially Reflecting Surface

... broadband Fabry-Perot cavity antenna designed using an improved resonance prediction method,” ...“Wideband Fabry-Perot resonator antenna with two complementary FSS layers,” IEEE ...

7

Electrostatic MEMs Fabry-Perot Modulators in the Visible Spectrum and Electrothermal Wrinkling of Bilayer Thin Films

Electrostatic MEMs Fabry-Perot Modulators in the Visible Spectrum and Electrothermal Wrinkling of Bilayer Thin Films

... Now the microscope is moved away bringing in the suspended cage and aligning it with the optical fiber connected to the spectrometer. Using a screw knot, the final position of the suspended cage on the rail can be fixed ...

197

Show all 170 documents...

Related subjects