• No results found

Full-field strain measurement

Calibration and evaluation of optical systems for full-field strain measurement

Calibration and evaluation of optical systems for full-field strain measurement

... and strain analysis remains the status ...evaluating full-field strain ...for full-field strain evaluation or for evaluating such an instrument against its design ...

30

Full-field Strain Analysis of a Ski Boot

Full-field Strain Analysis of a Ski Boot

... the measurement of the deformation of the boot during the contact of the ski with the ground of the ...local strain in selected areas of the boot was determined for both quasi-static and dynamic test ...

6

Combined full field stress and strain measurement methods for granular materials

Combined full field stress and strain measurement methods for granular materials

... The size of the physical models as used in geomechanics tends to be quite large in order to preserve a reasonable grain size to structure size ratio. This size typically is larger than the size of available retardation ...

8

Full-field analysis of epicardial strain in an in vitro porcine heart platform.

Full-field analysis of epicardial strain in an in vitro porcine heart platform.

... 2D-STE). Full-field optical techniques applied in in vitro models of the heart can be used to capture the local behaviour of epicardial strain providing a reference measurement for the validation of ...

8

Measurement of full-field deformation induced by a dc electrical field in organic insulator films

Measurement of full-field deformation induced by a dc electrical field in organic insulator films

... mechanical strain levels is necessary for a better comprehension of the insulating material behaviour under electrical ...the full-field surface deformation of polymer films under electrical stress ...

9

Full-Field Displacement Measurement Technique by Using Repeated Patterns and JPEG Compressed Images

Full-Field Displacement Measurement Technique by Using Repeated Patterns and JPEG Compressed Images

... point measurement method, image-based measurement using a digital camera attracts a lot of attention because its simple setup, low cost, high accuracy and full-field measurement [2, ...

5

Strain Localisation and Damage Measurement by Full 3D Digital Image Correlation: Application to 15-5PH Stainless Steel

Strain Localisation and Damage Measurement by Full 3D Digital Image Correlation: Application to 15-5PH Stainless Steel

... the strain field on each face and follow the strain evolution at each ...thickness field, which enables one, in fine, to track the volume variations and deduce the dam- ...the field ...

14

Cascaded fiber optic Fabry Perot interferometers with Vernier effect for highly sensitive measurement of axial strain and magnetic field

Cascaded fiber optic Fabry Perot interferometers with Vernier effect for highly sensitive measurement of axial strain and magnetic field

... mode field mismatch between them. In order to take full advantage of the Vernier effect, a periodic spectrum with dip or peak having the same amplitude is ...

9

Calibration and validation of full-field techniques

Calibration and validation of full-field techniques

... the strain values on the surface of the (planar) reference ...the measurement but also the identification of corresponding locations x, y which is a pre-requisite for a point-by-point ...a ...

6

Brief communication: Full-field deformation measurement for uniaxial compression of sea ice using the digital image correlation method

Brief communication: Full-field deformation measurement for uniaxial compression of sea ice using the digital image correlation method

... the strain fields for the dif- in the early stages before ...larger strain val- ues than other ...the strain field of the x direction, and the relatively large values were apparently ...

8

Full 3D displacement field measurement by Optical Scanning Tomography and PIV Tomography

Full 3D displacement field measurement by Optical Scanning Tomography and PIV Tomography

... 4 Digital Volume CorreIation Digital volume correlation is the 3D extension of the correlation of 2D images which is usually used for the measurement of displacements in a plane. This technique makes it possible ...

8

Full-Field 3D Shape Measurement of Specular Object Having Discontinuous Surfaces

Full-Field 3D Shape Measurement of Specular Object Having Discontinuous Surfaces

... novel full-field 3D shape measurement method of specular object having discontinuous surfaces by building the direct relationship between the absolute phase and depth ...obtains ...

12

Force Measurement using Strain Gauge

Force Measurement using Strain Gauge

... 5. CONCLUSIONS The problem we undertook in this project, was to make an easy to use, effective and easily replicable project for students and people without any electronics background. To accomplish this feat, we ...

8

2. Stress and Strain Analysis and Measurement

2. Stress and Strain Analysis and Measurement

... stress level of the lower yield point. This characteristic of mild steel to “flow”, “neck” or “draw” without rupture when the yield point has been exceeded has led to the concepts of plastic, limit or ultimate design. ...

41

Optical Strain Measurement of Plastic Strain Localization in Nuclear Waste Copper Canisters

Optical Strain Measurement of Plastic Strain Localization in Nuclear Waste Copper Canisters

... Lid (FSW) 61 29 62 31 53 Tensile testing was performed by MTS 810 material test system at a constant rate of 0.02 mm/s using flat tensile samples. Welds were located at the centre of the gauge length of the specimens. ...

9

The measurement and interpretation of small strain stiffness of soils

The measurement and interpretation of small strain stiffness of soils

... The analysis of a deformation behaviour of a triaxial sample under undrained triaxial compression showed that for a single element of soil the value of Gmax determines the magnitude of t[r] ...

278

Displacement of Bridge Monitoring Techniques with Strain Measurement

Displacement of Bridge Monitoring Techniques with Strain Measurement

... electronic strain gauge are applied and the measurement results has larger white noise, several times averaging are needed to eliminate white ...electronic strain gauge to calculate ...

7

Flight Test Data System for Strain Measurement

Flight Test Data System for Strain Measurement

... the full-bridge ...and full-bridge ...and full- bridge configurations performed better is that the noise injected into the excitation node of the Wheatstone bridge is subtracted between the ...

240

Strain Measurement on a Compact Nuclear Reactor Pressurizer

Strain Measurement on a Compact Nuclear Reactor Pressurizer

... the strain gage located in the internal walls of the equipment (SG-01), distant from any discontinuity (that measures the general membrane stress) cannot accuse a stress larger than 0,9 Sy = 0,9 x 318 = 286 ...

13

Digital eye strain: prevalence, measurement and amelioration

Digital eye strain: prevalence, measurement and amelioration

... eye strain (DES), also known as computer vision syndrome, encompasses a range of ocular and visual symptoms, and estimates suggest its prevalence may be 50% or more among computer ...

10

Show all 10000 documents...

Related subjects