• No results found

glucose detection

Sensitive Nonenzymatic Electrochemical Glucose Detection Based on Hollow Porous NiO

Sensitive Nonenzymatic Electrochemical Glucose Detection Based on Hollow Porous NiO

... based glucose detection electrodes in Table ...towards glucose in terms of high sensitivity and low LOD, indicating potential applications in elec- trochemical glucose ...

10

Challenges & Countermeasures in Optical Noninvasive Blood Glucose Detection

Challenges & Countermeasures in Optical Noninvasive Blood Glucose Detection

... F. Raman spectroscopy: When a laser light is focused over a liquid sample, it triggers the vibration and rotation phenomenon in that sample [2, 3, 17-19]. The scattered light that it emits is proportionate to the ...

6

Integration of Enzyme Immobilised Single-walled Carbon Nanotube Arrays into Microchannels for Glucose Detection

Integration of Enzyme Immobilised Single-walled Carbon Nanotube Arrays into Microchannels for Glucose Detection

... for glucose detection have been constructed and developed by integration of covalently immobilised single-walled carbon nanotube arrays functionalised with glucose oxidase into a poly ...

14

Nanostructured biosensor using bioluminescence quenching technique for glucose detection

Nanostructured biosensor using bioluminescence quenching technique for glucose detection

... the glucose detection by using the bioluminescent sen- sor, it should be noted that the concentration of fructose in human blood (both healthy and diabetes subjects) is very low, almost one thousand-fold ...

9

Nanostructured biosensor for tear glucose detection based on bioluminescence resonance energy transfer (BRET) mechanism.

Nanostructured biosensor for tear glucose detection based on bioluminescence resonance energy transfer (BRET) mechanism.

... the glucose level steady however for the patients, either their pancreas does not produce enough insulin or the body cannot use them effectively ...control glucose concentration level is important for ...

80

Glucose oxidase complexed gold-graphene nanocomposite on a dielectric surface for glucose detection: a strategy for gestational diabetes mellitus

<p>Glucose oxidase complexed gold-graphene nanocomposite on a dielectric surface for glucose detection: a strategy for gestational diabetes mellitus</p>

... Nanomaterial application in the fi eld of biosensor has mainly used in two ways. One is for surface modi fi cation and other one is the conjugation with the desired molecule to elevate the limit of detection. 19,20 ...

10

Ultrasensitive and selective non-enzymatic glucose detection based on pt electrode modified by carbon nanotubes@ graphene oxide/ nickel hydroxide-Nafion hybrid composite in alkaline media

Ultrasensitive and selective non-enzymatic glucose detection based on pt electrode modified by carbon nanotubes@ graphene oxide/ nickel hydroxide-Nafion hybrid composite in alkaline media

... shown in Fig 4a, the accumulation time of 30 s was selected as an optimum time for subsequent experiments. The influence of the amount of nafion on the analytical characteristics of the modified electrode is a vital ...

10

Blood Glucose Detection Using GSR Sensor

Blood Glucose Detection Using GSR Sensor

... Over the year 2014, about 2.6 millions of people diagnosed with diabetes in Malaysia. Many of these people are forced to draw blood every day in order to determine their blood glucose level. This information is ...

24

Transdermal Microneedle Array-based Sensor for Real Time Continuous Glucose Monitoring

Transdermal Microneedle Array-based Sensor for Real Time Continuous Glucose Monitoring

... for glucose in the presence of oxygen. Thus, glucose was effectively oxidized at the composite ...towards glucose was higher with MPA/GOx than that was observed in MPA/CS/GOx and MPA/PAA/GOx (data ...

12

Different Sensors Used for Biochemical Detection

Different Sensors Used for Biochemical Detection

... for glucose detection as well as for cancer ...the detection sensitivity or increase the ion ...the glucose solution with different concentrations as well as the MMPs extracted from humans ...

9

Photonic Crystal Based Ring Resonator Sensor for Detection of Glucose Concentration for Biomedical Applications

Photonic Crystal Based Ring Resonator Sensor for Detection of Glucose Concentration for Biomedical Applications

... Photonic sensing technology enables the new measurement possibility through accurate urine analysis for glucose concentration. Photonic crystal bandgap structures can be utilized for glucose ...

5

Rational Design of Ni(OH)2 Hollow Porous Architecture for High Sensitivity Enzyme Free Glucose Sensor

Rational Design of Ni(OH)2 Hollow Porous Architecture for High Sensitivity Enzyme Free Glucose Sensor

... Glucose detection is very important in clinical biochemis- try, food processing, and environmental ...for glucose is an urgent demand for these applications ...low detection limit ...

9

Cuprous Oxide Thin Film Non-Enzymatic Glucose Sensor Using Differential Pulse Voltammetry (DPV) and Other Voltammetry Methods and Comparing to Different Thin Film Electrodes on the Detection of Glucose in an Alkaline Solution

Cuprous Oxide Thin Film Non-Enzymatic Glucose Sensor Using Differential Pulse Voltammetry (DPV) and Other Voltammetry Methods and Comparing to Different Thin Film Electrodes on the Detection of Glucose in an Alkaline Solution

... Quantitative detection of glucose in both phosphate-buffered saline (PBS) and undiluted human serum were carried ...the glucose detection, demonstrating the excellent selectivity of this ...

13

Facile Synthesis of Cobalt Phosphate Hydrate Nanosheets with Enhanced Nonenzymatic Glucose Sensing

Facile Synthesis of Cobalt Phosphate Hydrate Nanosheets with Enhanced Nonenzymatic Glucose Sensing

... electrochemical glucose sensors ...nonenzymatic glucose detection in basic ...low detection limit, wide linear range, good stability and high ...

8

Online Full Text

Online Full Text

... detecting glucose value. The system was integrated with glucose detection system and transmission ...rapid detection, and the detection range from 100 mg/dL to 400 mg/dL with ...

5

Ultra Sensitivity Glucose Sensor Based on Field Emitters

Ultra Sensitivity Glucose Sensor Based on Field Emitters

... new glucose sensor based on the field emitter of ...of glucose concentrations from 1 nM to 50 lM is easily detected, which exhibits ultra-sensitivity for glucose ...of glucose concentration is ...

5

Beta-cell function is associated with metabolic syndrome in Mexican subjects

Beta-cell function is associated with metabolic syndrome in Mexican subjects

... the detection of subjects at metabolic balance from the control group who presented glucose, TAG, HDL-C, and TC values within the appropriate range, but higher β -cell function, increased IR and decreased ...

9

Lipid profile abnormalities seen in T2DM patients in primary healthcare in Turkey: a cross-sectional study

Lipid profile abnormalities seen in T2DM patients in primary healthcare in Turkey: a cross-sectional study

... from January 2014 to June 2014 in the outpatient de- partments of Family Medicine clinic of the Bezmialem Vakif University Hospital in the largest city of Turkey, namely Istanbul, in the north-west region of the country ...

6

Impact of screening and early detection of impaired fasting glucose tolerance and type 2 diabetes in Canada: a Markov model simulation

Impact of screening and early detection of impaired fasting glucose tolerance and type 2 diabetes in Canada: a Markov model simulation

... normal glucose state may stay in this state or progress to either impaired fasting glucose screen-detected or screen-undetected during the year ...fasting glucose conditions, they will move to the ...

7

Highly Sensitive and Indirect Electrochemical Sensing of Ascorbic Acid Based on the Catalytic Oxidation of Glucose on the Ni Nanoparticles-ionic Liquid Composite

Highly Sensitive and Indirect Electrochemical Sensing of Ascorbic Acid Based on the Catalytic Oxidation of Glucose on the Ni Nanoparticles-ionic Liquid Composite

... of glucose, the anodic peak current increased sharply and the oxidation potential moved to the positive direction(Figure 2c), which indicated Ni NP -IL/CPE can electrocatalyze the oxidation of ...

11

Show all 10000 documents...